XT1110: 16-Channel Discrete Ethernet I/O Modules with Sinking Outputs
Please sign in or register to see model options and to add products to your cart.
Product short description:
- 16 discrete tandem input/output channels
- Modbus TCP/IP, Ethernet/IP, Profinet, or i2o® communication
The XT1110 interfaces discrete I/O signals between measurement and control devices over Ethernet. Channels are individually configurable for input or low-side switched output operation.
XT1110: 16-Channel Discrete Ethernet I/O Modules with Sinking Outputs Description
The XT1110 interfaces discrete I/O signals between measurement and control devices over Ethernet. Channels are individually configurable for input or low-side switched output operation.
Rugged construction, high density design, and easy USB-to-PC/Windows setup combine for a very effective I/O solution.
These units are ideal for remote monitoring, distributed control, or SCADA applications.
Input/Output Ranges
Input: 0-32V DC, TTL thresholds
Output: 0-32V DC, open-drain, up to 250mA
Ethernet Communication
Modbus TCP/IP, i2o® peer-to-peer available for Modbus TCP/IP only
Ethernet/IP
Profinet
10/100Base-T(X)
PriorityChannel™ device determinism
Power Requirement: 12 to 32V DC (2.5W)
IMPORTANT:Â To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends use of the USB-ISOLATOR when configuring an XT1000 I/O module.
Learn more about the Ethernet XT Series and view all models >
XT1110: 16-Channel Discrete Ethernet I/O Modules with Sinking Outputs Features & Benefits
- 16 solid-state discrete I/O channels (any mix of inputs or outputs)
- Built-in 10K ohm pull-up resistors for 2/3-wire sensors (contacts, proximity, TTL)
- Configurable normal/reverse input logic
- Outputs include built-in read-back capability
- Easy setup with Windows software via USB
- Watchdog timer control of failsafe outputs
- Continuously changing “heart-beat” register validates module operation
- High-Density 22.5mm wide package with pluggable, front-facing terminals
- Dual Ethernet 10/100 ports (auto-negotiation) reduce switch port requirements
- 1500V AC isolation (between I/O, power, and network ports) and surge/transient protection
- Supports bussed/rail and redundant power
- -40°C to +70°C wide temperature operation
- Withstands 25g shock and 4g vibration
- CE and UL/cUL Class 1 Div 2 Zone 2 approvals. ATEX Certified.
Learn more about the Ethernet XT Series and view all models >
Specs & Catalogs
Manuals
Brochure
Drawings & Diagrams
-
XT-SIP: Software Interface Package
- Software Interface Package for BusWorks XT Series Ethernet I/O modules.
- Easy setup and digital calibration via USB with Windows configuration software
- Download software only from the Software Tab below
-
XTA-120V-6: Solid-State Relay Input Modules
- 6 optocoupler channels
- 120V AC/DC input with optical isolation
- Universal 5/12/24V logic output
-
XTA-MRNO-6: Mechanical Relay Output Modules
- 6 digital I/O channels
- Â Universal 5/12/24V logic inputs
- Â Form A, 250V AC / 30V DC @ 5A relay outputs
Additional information
Weight | 8 oz |
---|---|
Dimensions | 4.5 × 1.5 × 5 in |
Part Number | XT1111-000: Modbus/TCP and i2o protocol, XT1112-000: Ethernet/IP protocol, XT1113-000: Profinet protocol |
Product Series | BusWorks XT Series |
Communication | Ethernet/IP, i2o Peer-to-Peer, Modbus TCP/IP, Profinet |
Configuration | USB Configuration, Windows Software Configuration |
-
Description
XT1110: 16-Channel Discrete Ethernet I/O Modules with Sinking Outputs Description
The XT1110 interfaces discrete I/O signals between measurement and control devices over Ethernet. Channels are individually configurable for input or low-side switched output operation.
Rugged construction, high density design, and easy USB-to-PC/Windows setup combine for a very effective I/O solution.
These units are ideal for remote monitoring, distributed control, or SCADA applications.
Input/Output Ranges
Input: 0-32V DC, TTL thresholds
Output: 0-32V DC, open-drain, up to 250mAEthernet Communication
Modbus TCP/IP, i2o® peer-to-peer available for Modbus TCP/IP only
Ethernet/IP
Profinet
10/100Base-T(X)
PriorityChannel™ device determinismPower Requirement: 12 to 32V DC (2.5W)
IMPORTANT:Â To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends use of the USB-ISOLATOR when configuring an XT1000 I/O module.
Learn more about the Ethernet XT Series and view all models >
XT1110: 16-Channel Discrete Ethernet I/O Modules with Sinking Outputs Features & Benefits
- 16 solid-state discrete I/O channels (any mix of inputs or outputs)
- Built-in 10K ohm pull-up resistors for 2/3-wire sensors (contacts, proximity, TTL)
- Configurable normal/reverse input logic
- Outputs include built-in read-back capability
- Easy setup with Windows software via USB
- Watchdog timer control of failsafe outputs
- Continuously changing “heart-beat” register validates module operation
- High-Density 22.5mm wide package with pluggable, front-facing terminals
- Dual Ethernet 10/100 ports (auto-negotiation) reduce switch port requirements
- 1500V AC isolation (between I/O, power, and network ports) and surge/transient protection
- Supports bussed/rail and redundant power
- -40°C to +70°C wide temperature operation
- Withstands 25g shock and 4g vibration
- CE and UL/cUL Class 1 Div 2 Zone 2 approvals. ATEX Certified.
Learn more about the Ethernet XT Series and view all models >
-
Tech Papers
How to Communicate with Acromag Ethernet/IP Modules from CompactLogix Controllers - 8500762Communicating with Acromag Series 9xxEN-60xx, XTxxx2-xxx, and NTE2xxx-xxxx Ethernet/IP™ Modules from CompactLogix™ PLC Device This document illustrates a procedure for configuring message commands intended for Acromag Busworks® Series Ethernet/IP modules using Ladder Logic programming software in addition to a CompactLogix Programmable Controller. It is assumed that the user has a working knowledge of; Ladder Logic...How to Communicate with Modbus/TCP Modules from Ignition Software - 8501121Setting Up and Communicating with Acromag Series 9xxEN-40xx and XTxxx1-xxx Modbus/TCP Modules and EtherStax™ Modbus/TCP from Ignition Software This document illustrates a procedure for configuring OPC tags intended for Acromag BusWorks® Series Modbus/TCP modules using Windows software from Inductive Automation. It is assumed that the user has a working knowledge of OPC, Modbus TCP, and...How Does Ethernet I/O Simplify Communication Between One PLC and Multiple Remote Locations? - 8400822This document illustrates using Acromag’s BusWorks® XT Ethernet I/O modules to split one signal from a central control room PLC; and control multiple remote locations using Ethernet protocol. Defining the Problem: A customer has multiple remote locations linked over an Ethernet network, each requiring discrete outputs. They all need to be sent the same communication...How to Connect to Acromag Ethernet I/O Devices - 8500815Getting Connected to Acromag Ethernet I/O Devices These instructions summarize the basic steps you will have to take in order to initially connect an Acromag Ethernet I/O product to your Personal Computer (PC) or laptop. To connect an Ethernet device to your PC, consult with your network administrator. Either temporarily change the TCP/IP configuration of... -
Specs & Data Sheets
Specs & Catalogs
Manuals
Brochure
Drawings & Diagrams
-
Software
XT-SIP: Software Interface Information Page (Log in to download the file)Ethernet XT Series Configuration Software (Log in to download the file)ESW-MBLIB: Ethernet Modbus C Library Software Information Page (Log in to download the file)AMTx: Modbus TCP/IP Software Information Page (Log in to download the file)Profinet GSDML Files for XTxxx3-000 Modules (Log in to download the file)Ethernet IP EDS For XTxxx2-000 Modules (Log in to download the file) -
Accessories
-
XT-SIP: Software Interface Package
- Software Interface Package for BusWorks XT Series Ethernet I/O modules.
- Easy setup and digital calibration via USB with Windows configuration software
- Download software only from the Software Tab below
-
XTA-120V-6: Solid-State Relay Input Modules
- 6 optocoupler channels
- 120V AC/DC input with optical isolation
- Universal 5/12/24V logic output
-
XTA-MRNO-6: Mechanical Relay Output Modules
- 6 digital I/O channels
- Â Universal 5/12/24V logic inputs
- Â Form A, 250V AC / 30V DC @ 5A relay outputs
-
-
Additional information
Additional information
Weight 8 oz Dimensions 4.5 × 1.5 × 5 in Part Number XT1111-000: Modbus/TCP and i2o protocol, XT1112-000: Ethernet/IP protocol, XT1113-000: Profinet protocol
Product Series BusWorks XT Series
Communication Ethernet/IP, i2o Peer-to-Peer, Modbus TCP/IP, Profinet
Configuration USB Configuration, Windows Software Configuration
Please login to submit this form.