Product short description:
  • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
  • Universal Input (85-264V AC / 100-370V DC)
  • Lightweight and compact size

 

PS5R: Slim Line Power Supplies Description

PS5R Slim Line models feature universal voltage inputs. Use them in tight spaces or save valuable DIN rail space while still filling your requirements for power. PS5R-Vs have spring-up screw terminals, fused inputs and overload protection. They are DIN Rail or direct surface mountable (6 directions) and have universal (85 – 264V AC) voltage inputs.

Efficiency is the name of the game for PS5R-V. Improvements in operating efficiency and size lead to performance improvements. These improvements include expanded operating temperature range and a MTBF of up to 900,000 hours. Altogether, these improvements mean PS5R-V is an unmatched value.

The PS5R-V series boasts numerous worldwide approvals and certifications, including UL 508. All models under 100W are UL1310 Class 2 approved. Specialized approvals include Class I Division 2 for use in hazardous locations as well as SEMI F47 for use in sensitive equipment applications.

No derating means you save money, space and time. With nine models available, it’s easy to find the one that’s right for your application.

Features & Benefits

  • Compact size preserves panel space
  • Slim size (width):
    • 22.5mm (10W/15W/30W)
    • 36mm (60W/90W)
    • 46mm (120W)
    • 60mm (240W)
  • Universal Voltage Input: 85-264V AC/100-370V DC
  • Wide operating temperature range
  • Spring-up terminals accept ring & fork terminals
  • Approved for use in Class I Division 2 hazardous locations
  • Can be installed in 6 directions
  • 10W ~ 90W meet NEC Class 2 output ratings
  • Overcurrent protection with auto-reset
  • Meets SEMI F47 Sag Immunity (208V AC input)
  • RoHS compliant
  • Five-year factory warranty

 

How to Calculate a V-notch Weir Discharge Rate Q (GPH) - 8401009
Defining the Need: Calculate the discharge rate Q (g.p.h.) output of a V-notch weir. Provide a 4-20mA output for flowrate and frequency output for totalization and alarm output for high-level alarm. Solution: Model 892M-0500 DC output math module Model 895M-0800 freq. output math module Model 800C-SIP software interface package Optional: Model PS5R-VD24 power supply  ...
How to Use Acromag 600T Series Isolated Transmitters - 8401028
Application 1 Re-transmitting a signal from a two-wire loop to a second location. Solution Use either a model 651T-0600 (single channel) or 652T-0600 (dual channel) transmitter. Application 2 Splitting a signal from a two-wire loop: two outputs for different locations. Solution Use either a 653T-0600 (single input, dual output) or 652T-0600 (dual input, dual output)...
How to Scale and Sum up to Four 4-20mA Signals from Flow Sensors - 8401004
Defining the Need: Scaling and summing up to four 4-20mA signals from flow sensors. Solution: Model 894M-0500 quad-input math module Model 800C-SIP software interface package Optional: Model PS5R-VD24 power supply
How to Monitor RTDs for Temperature Differential - 8401008
Defining the Need: Monitor three RTD’s on a stack and transmit two differential 4-20mA signals representing -7 to 18°F. Each RTD transmitter is calibrated -20 to 120°F. Solution: Model 892M-0500 math module (qty. 3) Model 800C-SIP software interface pkg. (qty. 1) Model PS5R-VD24 power supply (qty. 1)   Download PDF for complete application note.
How to Transmit the Dosing Percentage of an Additive Based on Total Flow of Effluent - 8401006
Defining the Need: Transmitting the dosing percentage (ratio) of an additive based upon total flow of effluent. Solution: Model 892M-0500 dual-input math module Model 800C-SIP software interface package Optional: Model PS5R-VD24 power supply
How to Take the Square Root and Sum up to Four 4-20mA Signals from Flow Sensors - 8401005
Defining the Need: Taking the square root and summing up to four 4-20mA signals from flow sensors. Solution: Model 894M-0500 quad-input math module Model 800C-SIP software interface package Optional: Model PS5R-VD24 power supply
How to Create a 4-20mA Output Proportional to Flow Rate - 8400304
Problem: A flow sensor has a non-linear reversed output. Solution: Create a 4-20mA output proportional to flow rate using the following Acromag transmitter and software products: Model: 811T-0500 DC to DC Isolated Transmitter Model: 800C-SIP Software Interface Package Optional: PS5R-D24 Power Supply The 811T offers a 25 break-point table for sensor linearization. Input percentage is...
How to Convert a 4-20mA Level Signal to a 4-20mA Signal Proportional to Volume - 8401007
Defining the Problem: Convert a 4-20mA level signal (proportional to height) to a 4-20mA signal proportional to volume. Solution: Model 892M-0500 dual-input math module Model 800C-SIP software interface package Optional: Model PS5R-VD24 power supply     Download PDF for complete application note.

Additional information

Weight 16 oz
Dimensions 12 × 13 × 3 in
Part Number

PS5R-VB05: 10W universal power supply; 5V DC, PS5R-VB12: 15W universal power supply; 12V DC, PS5R-VB24: 15W universal power supply; 24V DC, PS5R-VC12: 30W universal power supply; 12V DC, PS5R-VC24: 30W universal power supply; 24V DC, PS5R-VD24: 60W universal power supply; 24V DC, PS5R-VE24: 90W universal power supply; 24V DC, PS5R-VF24: 120W universal power supply; 24V DC, PS5R-VG24: 240W universal power supply; 24V DC

  • Description

    PS5R: Slim Line Power Supplies Description

    PS5R Slim Line models feature universal voltage inputs. Use them in tight spaces or save valuable DIN rail space while still filling your requirements for power. PS5R-Vs have spring-up screw terminals, fused inputs and overload protection. They are DIN Rail or direct surface mountable (6 directions) and have universal (85 – 264V AC) voltage inputs.

    Efficiency is the name of the game for PS5R-V. Improvements in operating efficiency and size lead to performance improvements. These improvements include expanded operating temperature range and a MTBF of up to 900,000 hours. Altogether, these improvements mean PS5R-V is an unmatched value.

    The PS5R-V series boasts numerous worldwide approvals and certifications, including UL 508. All models under 100W are UL1310 Class 2 approved. Specialized approvals include Class I Division 2 for use in hazardous locations as well as SEMI F47 for use in sensitive equipment applications.

    No derating means you save money, space and time. With nine models available, it’s easy to find the one that’s right for your application.

    Features & Benefits

    • Compact size preserves panel space
    • Slim size (width):
      • 22.5mm (10W/15W/30W)
      • 36mm (60W/90W)
      • 46mm (120W)
      • 60mm (240W)
    • Universal Voltage Input: 85-264V AC/100-370V DC
    • Wide operating temperature range
    • Spring-up terminals accept ring & fork terminals
    • Approved for use in Class I Division 2 hazardous locations
    • Can be installed in 6 directions
    • 10W ~ 90W meet NEC Class 2 output ratings
    • Overcurrent protection with auto-reset
    • Meets SEMI F47 Sag Immunity (208V AC input)
    • RoHS compliant
    • Five-year factory warranty

     

  • Tech Papers

    How to Calculate a V-notch Weir Discharge Rate Q (GPH) - 8401009
    Defining the Need: Calculate the discharge rate Q (g.p.h.) output of a V-notch weir. Provide a 4-20mA output for flowrate and frequency output for totalization and alarm output for high-level alarm. Solution: Model 892M-0500 DC output math module Model 895M-0800 freq. output math module Model 800C-SIP software interface package Optional: Model PS5R-VD24 power supply  ...
    How to Use Acromag 600T Series Isolated Transmitters - 8401028
    Application 1 Re-transmitting a signal from a two-wire loop to a second location. Solution Use either a model 651T-0600 (single channel) or 652T-0600 (dual channel) transmitter. Application 2 Splitting a signal from a two-wire loop: two outputs for different locations. Solution Use either a 653T-0600 (single input, dual output) or 652T-0600 (dual input, dual output)...
    How to Scale and Sum up to Four 4-20mA Signals from Flow Sensors - 8401004
    Defining the Need: Scaling and summing up to four 4-20mA signals from flow sensors. Solution: Model 894M-0500 quad-input math module Model 800C-SIP software interface package Optional: Model PS5R-VD24 power supply
    How to Monitor RTDs for Temperature Differential - 8401008
    Defining the Need: Monitor three RTD’s on a stack and transmit two differential 4-20mA signals representing -7 to 18°F. Each RTD transmitter is calibrated -20 to 120°F. Solution: Model 892M-0500 math module (qty. 3) Model 800C-SIP software interface pkg. (qty. 1) Model PS5R-VD24 power supply (qty. 1)   Download PDF for complete application note.
    How to Transmit the Dosing Percentage of an Additive Based on Total Flow of Effluent - 8401006
    Defining the Need: Transmitting the dosing percentage (ratio) of an additive based upon total flow of effluent. Solution: Model 892M-0500 dual-input math module Model 800C-SIP software interface package Optional: Model PS5R-VD24 power supply
    How to Take the Square Root and Sum up to Four 4-20mA Signals from Flow Sensors - 8401005
    Defining the Need: Taking the square root and summing up to four 4-20mA signals from flow sensors. Solution: Model 894M-0500 quad-input math module Model 800C-SIP software interface package Optional: Model PS5R-VD24 power supply
    How to Create a 4-20mA Output Proportional to Flow Rate - 8400304
    Problem: A flow sensor has a non-linear reversed output. Solution: Create a 4-20mA output proportional to flow rate using the following Acromag transmitter and software products: Model: 811T-0500 DC to DC Isolated Transmitter Model: 800C-SIP Software Interface Package Optional: PS5R-D24 Power Supply The 811T offers a 25 break-point table for sensor linearization. Input percentage is...
    How to Convert a 4-20mA Level Signal to a 4-20mA Signal Proportional to Volume - 8401007
    Defining the Problem: Convert a 4-20mA level signal (proportional to height) to a 4-20mA signal proportional to volume. Solution: Model 892M-0500 dual-input math module Model 800C-SIP software interface package Optional: Model PS5R-VD24 power supply     Download PDF for complete application note.
  • Specs & Data Sheets

  • Additional information

    Additional information

    Weight 16 oz
    Dimensions 12 × 13 × 3 in
    Part Number

    PS5R-VB05: 10W universal power supply; 5V DC, PS5R-VB12: 15W universal power supply; 12V DC, PS5R-VB24: 15W universal power supply; 24V DC, PS5R-VC12: 30W universal power supply; 12V DC, PS5R-VC24: 30W universal power supply; 24V DC, PS5R-VD24: 60W universal power supply; 24V DC, PS5R-VE24: 90W universal power supply; 24V DC, PS5R-VF24: 120W universal power supply; 24V DC, PS5R-VG24: 240W universal power supply; 24V DC