Showing all 11 results
-
VPM3000 Series: Universal Transmitter / Alarm with Display
- Big, bright display
- 4-20mA, ±10V, thermocouple, or RTD input
- 4-20mA, Modbus serial, or alarm relay output options
-
901MB, 902MB, 903MB: Multi-Channel Modbus-RTU Discrete I/O Modules
- Active-Low Inputs, Sinking Outputs (Low-Side Switching)
- 12 input and/or 12 output channels
- 0 to 35V DC I/O range
- 10 to 36V DC, 24V AC power
- Modbus-RTU high-speed RS-485
-
904MB, 905MB, 906MB: Multi-Channel Discrete I/O Modules
- Active-High Inputs, Sourcing Outputs (High-Side Switching)
- 12 input and/or 12 output channels
- 0 to 35V DC I/O range
- 10 to 36V DC, 24V AC power
- Modbus-RTU high-speed RS-485
-
913MB, 914MB: DC Current/Voltage Modbus-RTU Input Module with Limit Alarms
- 4 input channels
- 0 to 20mA DC (0 to 20A AC with AC sensor) or ±10V DC input range
- 4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
- 10 to 36V DC, 24V AC power
- Modbus RTU high-speed RS-485
-
917MB, 918MB: DC Current/Voltage Modbus-RTU Output Modules with Discrete Outputs
- 4 analog output channels
- 0 to 20mA or 0 to 10V DC output range
- 4 discrete output channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
- 10 to 36V DC, 24V AC power
- Modbus RTU high-speed RS-485
-
924MB: Thermocouple/milliVolt Modbus-RTU Input Module with Limit Alarms
- 4 input channels, thermocouple (types J, K, T, R, S, E, B, N) or millivolt (±100mV DC) input
- 4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
- 10 to 36V DC, 24V AC power
- Modbus-RTU high-speed RS-485
-
932MB, 934MB: RTD/Resistance Modbus-RTU Input Modules with Limit Alarms or Discrete Outputs
- 2 or 4 input channels, RTD (100 ohm Pt, 120 ohm Ni, 10 ohm Cu) or resistance (0 to 500 ohms) input
- Solid-state relays discrete output, Form A, SPST-NO
- 10 to 36V DC, 24V AC power
- Modbus-RTU high-speed RS-485
-
942MB: Frequency/Pulse Counter Modbus-RTU Input Modules with Periodic or Pulse Waveform Input
- 2 input channels, 0 to 50KHz in 3 selectable ranges: Amplitudes up to 140V AC peak, Amplitudes up to 200V peak, Pulse counter range of 0 to 65535
- Solid-state discrete output relays (1A DC loads), 0 to 48V DC
- 10 to 36V DC, 24V AC power
- Modbus-RTU high-speed RS-485
-
AMTN, AMTX: ActiveX / .NET Controls for Modbus I/O
- Modbus/TCP or Modbus/RTU
- These ActiveX / .NET software controls provide a fast, easy way to communicate with any Modbus slave devices connected to your PC.
- Get your Visual Basic, Visual C, .NET, Excel, or other compatible applications talking Modbus protocol within minutes.
-
APM765 Series: Universal Input with Alarm Panel Meter
- Universal input
- Isolated 4-20mA and Modbus output options
- Push-button or PC programmable,
- 85-265V AC or 90-265V DC power, optional 12-24V AC or 12-36V DC power
-
4683 Series: RS485-to-RS485 Network Repeater
- Designed for use with Johnson Controls N2 or BACnet MS/TP bus
- 115V AC ±10%, 50/60 Hz, 0.05A or 230V AC ±10%, 50/60 Hz, 0.03A or 24V AC ±10%, 50/60 Hz, 0.18A typical power
- Operating temperature: -25 to 70° C (-13 to 158° F)