APM765 Series: Universal Input with Alarm Panel Meter
Product short description:
- Universal input
- Isolated 4-20mA and Modbus output options
- Push-button or PC programmable,
- 85-265V AC or 90-265V DC power, optional 12-24V AC or 12-36V DC power
The APM765 displays data collected from process current, DC voltage and temperature inputs. Several output options convert the display into a transmitter with proportional 4-20mA output or a serial communication interface.
- Description
- Features & Benefits
- Tech Papers
- Specs & Data Sheets
- Software
- Accessories
- Additional information
The APM765 Panel Meter displays data collected from process current, DC voltage and temperature inputs. Several output options convert the display into a transmitter with proportional 4-20mA output or a serial communication interface. A relay output option adds limit alarm and pump control capabilities.
Process inputs can be scaled with or without applying an input for virtually any engineering units. Temperature inputs can be programmed to display in degrees Fahrenheit or Celsius.
Inputs
4-20mA DC, ±20mA DC, ±10V DC
Type J, K, T, E thermocouples
100 ohm platinum RTDs
Outputs (optional)
4-20mA (sink/source)
Dual SPDT (Form C) 3A relays
RS-232, RS-422/485 serial communication
Power Requirements
Standard unit: 85-265V AC or 90-265V DC
Optional: 12-24V AC or 12-36V DC
Operating Temperature: 0 to 65°C
Approvals: CE marked, UL, cUL listed
DC Process and Temperature Inputs
The APM765 Panel Meter is factory calibrated to accept 4-20 mA, ±10 VDC, Type J, K, T, E thermocouples and 100 ohm platinum RTDs. Process inputs can be scaled with or without applying an input for virtually any engineering units. Temperature inputs can be programmed to display in degrees Fahrenheit or Celsius and a type K thermocouple can display up to 2300°F.
Current/Voltage Input
Setting up the panel meter to accept a current or voltage input is very easy. All setup steps are performed by push-buttons or through software so there are no switches or jumpers to adjust.
Thermocouple/RTD Input
Setting up the APM765 Panel Meter to accept thermocouple or RTD input is simply a matter of setting a switch at the rear of the case and selecting the input type from the menu.
Meters accept J, K, T, or E type thermocouples as well as two, three, or four-wire 100 ohm platinum RTDs.
Serial or Modbus Output
The APM765 Panel Meter can be used as a data acquisition device, with the added benefit of a digital display, by connecting an optional RS-232 or RS-422/485 serial communication adapter.
Acromag offers MeterView software for simple data acquisition and to program the meter.
Serial Communications
Meter Address: Modbus protocol: 1 – 247 (default 247)
Baud Rate: 300 – 19,200 bps (default 2400)
Transmit Time Delay: Programmable between 0 and 199mS or Transmitter always on for RS422 communication (default 10mS)
Data: 8 bit (1 start bit, 1 stop bit)
Parity: None, even, or odd (default even)
Byte-to-Byte Timeout: 0.01 – 2.54 seconds (default 0.01 seconds)
Turn Around Delay: Less than 2mS (fixed)
MeterView Software
MeterView software enables PC programming of the APM765 and sets up data logger operation.
Remote Programming
MeterView software allows all setup parameters to be programmed from a PC and saved to a file for reporting or programming other meters.
Data Acquisition
MeterView software provides a convenient way to collect the data generated from the serial output of up to 100 panel meters. The user can select the logging time interval and the engineering units that will be displayed on the computer screen. Data is written to a file that could then be imported into a spreadsheet or other application.
Performance Specifications
Specifications apply to operation at 25°C.
General
Display: 0.56”(14.2 mm) red leds. Four digits (-1999 to 9999)
Display Intensity: Eight user-selectable intensity levels
Front Panel: Nema 4x, ip65. Panel gasket provided
Programming Methods: Four front panel push buttons, pc and meterview software, or cloning with copy feature.
Noise Filter: Programmable between 2 – 199 (0 will disable filter)
Display Update Rate: 1.8-2.5/sec for tc input or 3.7-5/sec for process/rtd
Overrange and Underrange: Display flashes 9999 (over) or -1999 (under)
Max/Min Display: Stored until reset by user or meter is turned off
Non-volatile Memory: All programmed settings are stored in nonvolatile memory for a minimum of ten years if power is lost.
Power:
AC: 85-265 VAC, 50/60 Hz, 20 VA
DC: 90-265 VDC, 20 W
Option: 12-36 VDC or 12-24 VAC
Required Fuse: Ul recognized, 5a max, slow blow (up to six meters may share one fuse)
Normal Mode Rejection: 64 db at 50/60 hz
Isolation
Input or output to power line: 4kv
Input or output to p1 or p2: 500v
Input to output: 500v
p1 to p2: 500v
Environmental
Operating range: 0 to 65°c (32 to 149°f)
Storage range: -40 to 85°c (-40 to 185°f)
Relative humidity: 0 to 90% non-condensing
Connections
Power & signal: removable screw terminal blocks accept 12 to 26 awg.
Serial: rj11 header, standard on all meters.
Enclosure: 1/8 din, high impact plastic, 94v-0, color; gray
Weight: 8 oz (227 g) (no options)
Process Inputs
Inputs: Field Selectable: ±20 Ma Dc and ±10 VDC
Accuracy: ±0.05% Of Calibrated Span ±1 Count, Square Root: 10-100% F.S.
Low-Flow Cutoff: 0 To 9999 (0 Disables Cutoff Function)
Decimal Point: Up to Three Decimal Places: d.ddd, dd.dd, ddd.d,or dddd
Calibration: Internal or External Signal or with PC
Calibration Range: User Programmable Over Entire Range of Meter
Input Impedance
Voltage Range: Greater Than 1m Ohms
Current Range: 50-100 Ohms
Input Overload: Protected by Automatically Resettable Fuse
Temperature Drift: ±50 Ppm/°C
Transmitter Supply
Isolated, one or two transmitter supplies (optional)
p1 (-1 option): 24 vdc ±10% @ 200ma max
p1/p2 (-2 option)
p1: 24 vdc ±10% @ 200ma
p2: 24 vdc ±10% @ 40ma
Temperature Inputs
Inputs:Â Factory calibrated, field selectable: type J, K, T, or E thermocouples and 100 ohm. platinum RTD (0.00385 or 0.00392 curve).
Resolution: 1°; type T, 1° or 0.1°
Accuracy:
Type    Temperature Range           Accuracy
J       -58 to 1382°F (-50 to 750°C)      ±2°F (±1°C)
K      -58 to 2300°F (-50 to 1260°C)     ±2°F (±1°C)
T     -292 to 700°F (-180 to 371°C)      ±2°F (±1°C)
E      -58 to 1578°F (-50 to 870°C)      ±2°F (±1°C)
RTD   -328 to 1382°F (-200 to 750°C)     ±1°F (±1°C)
Cold Junction Reference:Â Automatic
Temperature Drift: ±2°C maximum, 0 to 65°C ambient temperature
Offset Adjustment: Programmable to ±19.9°. This allows the user to apply an offset value to the temperature being displayed.
Input Impedance: Greater than 100k ohms
Sensor Break:
All relays and alarm status LEDs go to alarm state.
Analog output may go to pre-programmed state.
Display will flash.
Relays
Rating: 2 SPDT (form C); rated 3 amps @ 30 VDC or 3 amps @ 250 VAC resistive load; 1/14 HP @ 125/250 VAC for inductive loads.
Deadband: 0-100% of full scale, user selectable
High or Low Alarm: User may program any alarm for high or low
Relay Operation:
1. Automatic (non-latching)
2. Latching
3. Pump alternation control
Relay Reset:
User selectable via front panel buttons or PC
1. Automatic reset only (non-latching)
2. Automatic + manual reset any time (non-latching)
3. Manual reset only, at any time (latching)
4. Manual reset only after alarm condition has cleared (latching)
Automatic reset: Resets when input passes reset point
Manual reset: Front panel ACK button
Time Delay: 0 to 199 seconds, on and off delays; programmable
Fail-Safe Operation:
Programmable, independent for each relay.
Relay coils are energized in normal condition.
In case of alarm or power failure, relays will go to de-energized state.
Auto Initialization: When power is applied to the meter, relays will reflect the state of the input to the meter.
Isolated 4-20mA Output
Output Range:
1.00 to 23.00mA typical
Scalable for 0.00 to 23.99mA
Factory calibrated for 4-20 mA
Accuracy: ±0.1% F.S. ±0.004 mA
Temperature Drift: 50 PPM/°C from 0 to 65°C ambient.
Note: Analog output drift is separate from input drift.
Output Loop Resistance:
Power Supply    Minimum   Maximum
24 VDC             10 ohms     700 ohms
35 VDC (external)  100 ohms    1200 ohms
Output Maximum Load: Rload (max) = (Vsupply – 10V) / 0.020A
External Power Range: 10-35 VDC
- Universal input (TC, RTD, mA, V DC)
- Sunlight-readable display (adjustable intensity)
- Push-button or PC programmable
- Dual relay option for limit alarms or pump control (with alternation)
- Isolated 4-20mA output options (sink/source)
- Single/dual 24V DC isolated power options
- Modbus RTU communication option
- Data acquisition and logging capabilities with MeterView software
- Universal power supply 90-265 VAC/VDC
- Shallow depth package (3.6″ behind panel)
- 0 to 65°C
Specifications
-
4001-095: USB-to-Serial Adapter
- USB-to-serial adapter
- Easy to use to setup and re-configure modules
$40Select options -
Digital Display Panel Meter Accessories
- Plastic enclosure
- Pipe-mount kit
- Cables
- Adapters
$25 – $200Select options
Additional information
Weight | 10 oz |
---|---|
Dimensions | 3 × 5 × 4.5 in |
Part Number | APM765-6R0-00: 85-265V AC or 90-265V DC Power, APM765-6R0-10: 85-265V AC or 90-265V DC Power with 24V DC Supply, APM765-6R2-00: 85-265V AC or 90-265V DC Power with Two Relays, APM765-6R2-10: 85-265V AC or 90-265V DC Power with 24V DC Supply and Two Relays, APM765-6R3-00: 85-265V AC or 90-265V DC Power with 4-20mA Output, APM765-6R3-10: 85-265V AC or 90-265V DC Power with 24V DC Supply and 4-20mA Output, APM765-6R3-20: 85-265V AC or 90-265V DC Power with Dual 24V DC Supplies and 4-20mA Output, APM765-7R0-00: 12-36V DC or 12-24V AC Power, APM765-7R2-00: 12-36V DC or 12-24V AC Power with Two Relays, APM765-7R3-00: 12-36V DC or 12-24V AC Power with 4-20mA Output, APM765-6R5-10: 85-265V AC or 90-265V DC Power with 24V DC Supply, APM765-7R5-00: 12-36V DC or 12-24V AC Power with 4-20mA Output |
Communication | Modbus-RTU |
Product Series | APM765 Series |
-
Description
The APM765 Panel Meter displays data collected from process current, DC voltage and temperature inputs. Several output options convert the display into a transmitter with proportional 4-20mA output or a serial communication interface. A relay output option adds limit alarm and pump control capabilities.
Process inputs can be scaled with or without applying an input for virtually any engineering units. Temperature inputs can be programmed to display in degrees Fahrenheit or Celsius.
Inputs
4-20mA DC, ±20mA DC, ±10V DC
Type J, K, T, E thermocouples
100 ohm platinum RTDsOutputs (optional)
4-20mA (sink/source)
Dual SPDT (Form C) 3A relays
RS-232, RS-422/485 serial communicationPower Requirements
Standard unit: 85-265V AC or 90-265V DC
Optional: 12-24V AC or 12-36V DCOperating Temperature: 0 to 65°C
Approvals: CE marked, UL, cUL listed
DC Process and Temperature Inputs
The APM765 Panel Meter is factory calibrated to accept 4-20 mA, ±10 VDC, Type J, K, T, E thermocouples and 100 ohm platinum RTDs. Process inputs can be scaled with or without applying an input for virtually any engineering units. Temperature inputs can be programmed to display in degrees Fahrenheit or Celsius and a type K thermocouple can display up to 2300°F.
Current/Voltage Input
Setting up the panel meter to accept a current or voltage input is very easy. All setup steps are performed by push-buttons or through software so there are no switches or jumpers to adjust.Thermocouple/RTD Input
Setting up the APM765 Panel Meter to accept thermocouple or RTD input is simply a matter of setting a switch at the rear of the case and selecting the input type from the menu.
Meters accept J, K, T, or E type thermocouples as well as two, three, or four-wire 100 ohm platinum RTDs.Serial or Modbus Output
The APM765 Panel Meter can be used as a data acquisition device, with the added benefit of a digital display, by connecting an optional RS-232 or RS-422/485 serial communication adapter.
Acromag offers MeterView software for simple data acquisition and to program the meter.Serial Communications
Meter Address: Modbus protocol: 1 – 247 (default 247)
Baud Rate: 300 – 19,200 bps (default 2400)
Transmit Time Delay: Programmable between 0 and 199mS or Transmitter always on for RS422 communication (default 10mS)
Data: 8 bit (1 start bit, 1 stop bit)
Parity: None, even, or odd (default even)
Byte-to-Byte Timeout: 0.01 – 2.54 seconds (default 0.01 seconds)
Turn Around Delay: Less than 2mS (fixed)MeterView Software
MeterView software enables PC programming of the APM765 and sets up data logger operation.
Remote Programming
MeterView software allows all setup parameters to be programmed from a PC and saved to a file for reporting or programming other meters.Data Acquisition
MeterView software provides a convenient way to collect the data generated from the serial output of up to 100 panel meters. The user can select the logging time interval and the engineering units that will be displayed on the computer screen. Data is written to a file that could then be imported into a spreadsheet or other application.Performance Specifications
Specifications apply to operation at 25°C.
General
Display: 0.56”(14.2 mm) red leds. Four digits (-1999 to 9999)
Display Intensity: Eight user-selectable intensity levels
Front Panel: Nema 4x, ip65. Panel gasket provided
Programming Methods: Four front panel push buttons, pc and meterview software, or cloning with copy feature.
Noise Filter: Programmable between 2 – 199 (0 will disable filter)
Display Update Rate: 1.8-2.5/sec for tc input or 3.7-5/sec for process/rtd
Overrange and Underrange: Display flashes 9999 (over) or -1999 (under)
Max/Min Display: Stored until reset by user or meter is turned off
Non-volatile Memory: All programmed settings are stored in nonvolatile memory for a minimum of ten years if power is lost.
Power:
AC: 85-265 VAC, 50/60 Hz, 20 VA
DC: 90-265 VDC, 20 W
Option: 12-36 VDC or 12-24 VACRequired Fuse: Ul recognized, 5a max, slow blow (up to six meters may share one fuse)
Normal Mode Rejection: 64 db at 50/60 hz
Isolation
Input or output to power line: 4kv
Input or output to p1 or p2: 500v
Input to output: 500v
p1 to p2: 500vEnvironmental
Operating range: 0 to 65°c (32 to 149°f)
Storage range: -40 to 85°c (-40 to 185°f)
Relative humidity: 0 to 90% non-condensingConnections
Power & signal: removable screw terminal blocks accept 12 to 26 awg.
Serial: rj11 header, standard on all meters.Enclosure: 1/8 din, high impact plastic, 94v-0, color; gray
Weight: 8 oz (227 g) (no options)
Process Inputs
Inputs: Field Selectable: ±20 Ma Dc and ±10 VDC
Accuracy: ±0.05% Of Calibrated Span ±1 Count, Square Root: 10-100% F.S.
Low-Flow Cutoff: 0 To 9999 (0 Disables Cutoff Function)
Decimal Point: Up to Three Decimal Places: d.ddd, dd.dd, ddd.d,or dddd
Calibration: Internal or External Signal or with PC
Calibration Range: User Programmable Over Entire Range of Meter
Input Impedance
Voltage Range: Greater Than 1m Ohms
Current Range: 50-100 OhmsInput Overload: Protected by Automatically Resettable Fuse
Temperature Drift: ±50 Ppm/°C
Transmitter Supply
Isolated, one or two transmitter supplies (optional)
p1 (-1 option): 24 vdc ±10% @ 200ma max
p1/p2 (-2 option)
p1: 24 vdc ±10% @ 200ma
p2: 24 vdc ±10% @ 40maTemperature Inputs
Inputs:Â Factory calibrated, field selectable: type J, K, T, or E thermocouples and 100 ohm. platinum RTD (0.00385 or 0.00392 curve).
Resolution: 1°; type T, 1° or 0.1°
Accuracy:
Type    Temperature Range           Accuracy
J       -58 to 1382°F (-50 to 750°C)      ±2°F (±1°C)
K      -58 to 2300°F (-50 to 1260°C)     ±2°F (±1°C)
T     -292 to 700°F (-180 to 371°C)      ±2°F (±1°C)
E      -58 to 1578°F (-50 to 870°C)      ±2°F (±1°C)
RTD   -328 to 1382°F (-200 to 750°C)     ±1°F (±1°C)Cold Junction Reference: Automatic
Temperature Drift: ±2°C maximum, 0 to 65°C ambient temperature
Offset Adjustment: Programmable to ±19.9°. This allows the user to apply an offset value to the temperature being displayed.
Input Impedance: Greater than 100k ohms
Sensor Break:
All relays and alarm status LEDs go to alarm state.
Analog output may go to pre-programmed state.
Display will flash.Relays
Rating: 2 SPDT (form C); rated 3 amps @ 30 VDC or 3 amps @ 250 VAC resistive load; 1/14 HP @ 125/250 VAC for inductive loads.
Deadband: 0-100% of full scale, user selectable
High or Low Alarm: User may program any alarm for high or low
Relay Operation:
1. Automatic (non-latching)
2. Latching
3. Pump alternation controlRelay Reset:
User selectable via front panel buttons or PC
1. Automatic reset only (non-latching)
2. Automatic + manual reset any time (non-latching)
3. Manual reset only, at any time (latching)
4. Manual reset only after alarm condition has cleared (latching)Automatic reset: Resets when input passes reset point
Manual reset: Front panel ACK button
Time Delay: 0 to 199 seconds, on and off delays; programmable
Fail-Safe Operation:
Programmable, independent for each relay.
Relay coils are energized in normal condition.
In case of alarm or power failure, relays will go to de-energized state.Auto Initialization: When power is applied to the meter, relays will reflect the state of the input to the meter.
Isolated 4-20mA Output
Output Range:
1.00 to 23.00mA typical
Scalable for 0.00 to 23.99mA
Factory calibrated for 4-20 mAAccuracy: ±0.1% F.S. ±0.004 mA
Temperature Drift: 50 PPM/°C from 0 to 65°C ambient.
Note: Analog output drift is separate from input drift.Output Loop Resistance:
Power Supply    Minimum   Maximum
24 VDC             10 ohms     700 ohms
35 VDC (external)  100 ohms    1200 ohmsOutput Maximum Load: Rload (max) = (Vsupply – 10V) / 0.020A
External Power Range: 10-35 VDC
-
Features & Benefits
- Universal input (TC, RTD, mA, V DC)
- Sunlight-readable display (adjustable intensity)
- Push-button or PC programmable
- Dual relay option for limit alarms or pump control (with alternation)
- Isolated 4-20mA output options (sink/source)
- Single/dual 24V DC isolated power options
- Modbus RTU communication option
- Data acquisition and logging capabilities with MeterView software
- Universal power supply 90-265 VAC/VDC
- Shallow depth package (3.6″ behind panel)
- 0 to 65°C
-
Tech Papers
How to Excite a 2-wire, 4-20mA Continuous Level Sensor, and Provide Two Relay Outputs for Pump Down and High Alarm Application NotePump Down with High Alarm This document illustrates how to use the APM765-6R2-10 for exciting a 2-wire, 4-20mA continuous level sensor, and provide two relay outputs. One relay for pump down and one relay for high alarm with automatic or manual reset. Learn more about the APM765 Panel Meters here.How to Excite a 2-wire, 4-20mA Continuous Level Sensor and Provide two Relay Outputs for Duplex Pump Control with Alternation Application NotePump Down with Duplex Pump Control This document illustrates how to use APM765-6R2 meters for exciting a 2-wire, 4-20mA continuous level sensor, and provide two relay outputs for duplex pump control with alternation. Learn more about the APM765 Panel Meters here.How to Excite a 2-wire, 4-20mA Continuous Level Sensor and Provide Two Relay Outputs for Pump Up with Overfill Alarm Application NotePump Up with Overfill Alarm This document illustrates how to use APM765-6R2-10 meters for exciting a 2-wire, 4-20mA continuous level sensor, and provide two relay outputs. One relay is for pump control (filling) and the other relay is for high alarm (overfill) with automatic or manual reset. Learn more about the APM765 Panel Meters here.... -
Specs & Data Sheets
Specifications
-
Software
APM Panel Meter Demo Software (Log in to download the file) -
Accessories
-
4001-095: USB-to-Serial Adapter
- USB-to-serial adapter
- Easy to use to setup and re-configure modules
$40Select options -
Digital Display Panel Meter Accessories
- Plastic enclosure
- Pipe-mount kit
- Cables
- Adapters
$25 – $200Select options
-
-
Additional information
Additional information
Weight 10 oz Dimensions 3 × 5 × 4.5 in Part Number APM765-6R0-00: 85-265V AC or 90-265V DC Power, APM765-6R0-10: 85-265V AC or 90-265V DC Power with 24V DC Supply, APM765-6R2-00: 85-265V AC or 90-265V DC Power with Two Relays, APM765-6R2-10: 85-265V AC or 90-265V DC Power with 24V DC Supply and Two Relays, APM765-6R3-00: 85-265V AC or 90-265V DC Power with 4-20mA Output, APM765-6R3-10: 85-265V AC or 90-265V DC Power with 24V DC Supply and 4-20mA Output, APM765-6R3-20: 85-265V AC or 90-265V DC Power with Dual 24V DC Supplies and 4-20mA Output, APM765-7R0-00: 12-36V DC or 12-24V AC Power, APM765-7R2-00: 12-36V DC or 12-24V AC Power with Two Relays, APM765-7R3-00: 12-36V DC or 12-24V AC Power with 4-20mA Output, APM765-6R5-10: 85-265V AC or 90-265V DC Power with 24V DC Supply, APM765-7R5-00: 12-36V DC or 12-24V AC Power with 4-20mA Output
Communication Modbus-RTU
Product Series APM765 Series
Please login to submit this form.