XTA-120V-6: Solid-State Relay Input Modules
Please sign in or register to see model options and to add products to your cart.
Product short description:
- 6 optocoupler channels
- 120V AC/DC input with optical isolation
- Universal 5/12/24V logic output
The XTA-120V-6 optocoupler module provides six individually isolated 120V AC/DC digital (discrete) inputs to sense on/off levels and drive open-drain outputs. It is intended for use with BusWorks XT Series discrete I/O and other digital input modules to monitor contact closures or mains power supply high/low voltage levels.
XTA-120V-6: Solid-State Relay Input Modules Description
The XTA-120V-6 optocoupler module provides six individually isolated 120V AC/DC digital (discrete) inputs to sense on/off levels and drive open-drain outputs. It is intended for use with BusWorks XT Series discrete I/O and other digital input modules to monitor contact closures or mains power supply high/low voltage levels.
Each channel senses the presence or absence of high-level voltage to determine the status of proximity switches, limit switches, toggle switches, push buttons, contacts, and other devices. Opto-isolators control an open-drain output to safely interface the status of the monitored signal.
These modules are very easy to use. Removable front-facing terminal blocks on the module’s top and bottom greatly simplify field wiring.
Rugged construction and high density design combine for a very effective I/O solution. These units are ideal for remote monitoring, distributed control, or SCADA applications.
Input Ranges: 0-130Vrms or ±130V DC.
Output Ranges: Open-drain: 1KΩ pull-up to +5.3V DC, 0-32V DC maximum, 150mA sink.
Power Requirement: 12 to 32V DC (0.4W).
XTA-120V-6: Solid-State Relay Input Modules Performance Specifications
Input
Input Type: Six individually isolated voltage inputs interface voltage levels. Built-in hysteresis provides a sensing threshold for monitoring mains power.
Input Signal Voltage Range: 0-130Vrms or ±130V DC.
Input Signal Threshold
Low-to-High threshold: 90V AC or DC, typical.
High-to-Low threshold: 60V AC (55V DC), typical.
Input Hysteresis: 30V DC, typical.
Input Impedance: 46K ohms, typical.
Input Over-Voltage Protection: Metal Oxide Varistors (MOV) at every channel input. Rated Continuous Voltage: 130Vrms, 130V DC. Rated Maximum Clamping Voltage: 340V DC. Input channels also include capacitive filtering, and series resistance.
Output
Output Type: Six open-drain, mosfet switches with a common source connection at output return. Low-side (sinking) switching between load and return for DC voltage and current-sinking applications only. Output channels are pulled up to +5.3V with 1KΩ resistors.
Output “OFF” Voltage Range: 0-32V DC maximum.
Output “OFF” Leakage Current: 1µA typical, 50µA maximum (mosfet only, 25°C, 32V DC).
Output Pull-Ups: 1KΩ pull-ups to 5.3V DC.
Output Activation
Input                 Output
HIGH > 90V AC/DCÂ Â Â 5.3V (OFF)
LOW < 60V AC/DCÂ Â Â Â Â Â 0V (ON)
Output “ON” Current Range: 0 to 150mA DC, continuous, each channel.
Output Rds On Resistance: 2.5 ohms, maximum (150mA, 85°C).
Output Response Time: 45ms, typical (measured from input transition to output).
Output Pull-ups: Individual output channels include 1KΩ pull-ups to the internal +5.3V DC rail. If a stronger pull-up (lower resistance) is required, a resistor will have to be wired externally in parallel with the output channel.
Note: Do not exceed 150mA of drain current per output channel.
Environmental
Operating Temperature: -40 to 70°C (-40 to 158°F).
Storage Temperature: -40 to 85°C (-40 to 185°F).
Relative Humidity: 5 to 95% non-condensing.
Power Requirement: 12–32V DC SELV (Safety Extra Low Voltage). Current draw varies with power voltage as follows (current indicated is with all outputs ON).
Power Supply         Current Draw
12V DCÂ Â Â Â Â Â Â Â Â Â Â 23mA typical, 25mA maximum
15V DCÂ Â Â Â Â Â Â Â Â Â Â 19mA typical, 21mA maximum
24V DCÂ Â Â Â Â Â Â Â Â Â 13mA typical, 15mA maximum
32V DCÂ Â Â Â Â Â Â Â Â Â 11mA typical, 12mA maximum
Power Supply Effect: Less than ±0.001% of output span effect per volt DC of supply change.
Isolation
Inputs isolated from each other (channel-to-channel) and from output/power.
Peak: 1500V AC, ANSI/ISA-82.01-1988.
Continuous: 250V AC, 354V DC.
Shock and Vibration Immunity
Vibration: 4g, per IEC 60068-2-64.
Shock: 25g, per IEC 60068-2-27.
Electromagnetic Compatibility (EMC) Compliance
Radiated Emissions: BS EN 61000-6-4, CISPR 16.
RFI: BS EN 61000-6-2, IEC 61000-4-3.
Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6.
ESD: BS EN 61000-6-2, IEC 61000-4-2.
EFT: BS EN 61000-6-2, IEC 61000-4-4.
Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5.
Approvals
CE compliant. UL/cUL listings. ATEX Certified.
Designed for Class I; Division 2; Groups ABCD; Zone 2.
Physical
General: General purpose plastic enclosure for mounting on 35mm “T-type” DIN rail.
Case Material: Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General purpose NEMA Type 1 enclosure.
Circuit Board: Military grade fire-retardant epoxy glass per IPC-4101/98 with humi-seal conformal coating.
I/O Connectors: Removable plug-in type terminal blocks rated for 12A/250V; AWG #26-12, stranded/solid copper wire.
Dimensions
Width = 22.5mm (0.9 inches).
Length = 114.5mm (4.51 inches).
Depth = 99.0mm (3.90 inches).
Shipping Weight: 0.5 pounds (0.22 Kg) packed.
- Input ranges: 0-130V RMS, 130V DC
- Output ranges: Open-Drain with 1K Ohm pull-up to 5.3V DC; 0-32V DC Maximum, 150mA sink
- Power Requirement: 12 to 32V DC (0.4W)
- Six high-level voltage input channels
- Six logic-level output channels (open-drain, low-side switches)
- Built-in hysteresis optimized for mains power at 120Vrms
- Outputs include 1KΩ pull-ups to 5.3V DC
- High-density 22.5mm wide package with pluggable, front-facing terminals
- 1500V AC isolation (between each input and power/output) and surge/transient protection
- Supports bussed/rail and redundant power
- -40°C to 70°C wide temperature operation
- Withstands 25g shock and 4g vibration
- CE and UL/cUL Class 1 Div 2 Zone 2 approvals
- ATEX Certified
Specs & Catalogs
Manuals
XTA-120V-6 User Manual (Log in to download the file)
Additional information
Weight | 8 oz |
---|---|
Dimensions | 4.5 × 1.5 × 5 in |
Part Number | XTA-120V-6: 6-channel 120V AC/DC discrete input with 5V DC logic outputs |
Product Series | XTA Series |
-
Description
XTA-120V-6: Solid-State Relay Input Modules Description
The XTA-120V-6 optocoupler module provides six individually isolated 120V AC/DC digital (discrete) inputs to sense on/off levels and drive open-drain outputs. It is intended for use with BusWorks XT Series discrete I/O and other digital input modules to monitor contact closures or mains power supply high/low voltage levels.
Each channel senses the presence or absence of high-level voltage to determine the status of proximity switches, limit switches, toggle switches, push buttons, contacts, and other devices. Opto-isolators control an open-drain output to safely interface the status of the monitored signal.
These modules are very easy to use. Removable front-facing terminal blocks on the module’s top and bottom greatly simplify field wiring.
Rugged construction and high density design combine for a very effective I/O solution. These units are ideal for remote monitoring, distributed control, or SCADA applications.
Input Ranges: 0-130Vrms or ±130V DC.
Output Ranges: Open-drain: 1KΩ pull-up to +5.3V DC, 0-32V DC maximum, 150mA sink.
Power Requirement: 12 to 32V DC (0.4W).
XTA-120V-6: Solid-State Relay Input Modules Performance Specifications
Input
Input Type: Six individually isolated voltage inputs interface voltage levels. Built-in hysteresis provides a sensing threshold for monitoring mains power.
Input Signal Voltage Range: 0-130Vrms or ±130V DC.
Input Signal Threshold
Low-to-High threshold: 90V AC or DC, typical.
High-to-Low threshold: 60V AC (55V DC), typical.Input Hysteresis: 30V DC, typical.
Input Impedance: 46K ohms, typical.
Input Over-Voltage Protection: Metal Oxide Varistors (MOV) at every channel input. Rated Continuous Voltage: 130Vrms, 130V DC. Rated Maximum Clamping Voltage: 340V DC. Input channels also include capacitive filtering, and series resistance.
Output
Output Type: Six open-drain, mosfet switches with a common source connection at output return. Low-side (sinking) switching between load and return for DC voltage and current-sinking applications only. Output channels are pulled up to +5.3V with 1KΩ resistors.
Output “OFF” Voltage Range: 0-32V DC maximum.
Output “OFF” Leakage Current: 1µA typical, 50µA maximum (mosfet only, 25°C, 32V DC).
Output Pull-Ups: 1KΩ pull-ups to 5.3V DC.
Output Activation
Input                 Output
HIGH > 90V AC/DCÂ Â Â 5.3V (OFF)
LOW < 60V AC/DC      0V (ON)Output “ON” Current Range: 0 to 150mA DC, continuous, each channel.
Output Rds On Resistance: 2.5 ohms, maximum (150mA, 85°C).
Output Response Time: 45ms, typical (measured from input transition to output).
Output Pull-ups: Individual output channels include 1KΩ pull-ups to the internal +5.3V DC rail. If a stronger pull-up (lower resistance) is required, a resistor will have to be wired externally in parallel with the output channel.
Note: Do not exceed 150mA of drain current per output channel.
Environmental
Operating Temperature: -40 to 70°C (-40 to 158°F).
Storage Temperature: -40 to 85°C (-40 to 185°F).
Relative Humidity: 5 to 95% non-condensing.
Power Requirement: 12–32V DC SELV (Safety Extra Low Voltage). Current draw varies with power voltage as follows (current indicated is with all outputs ON).Power Supply         Current Draw
12V DCÂ Â Â Â Â Â Â Â Â Â Â 23mA typical, 25mA maximum
15V DCÂ Â Â Â Â Â Â Â Â Â Â 19mA typical, 21mA maximum
24V DCÂ Â Â Â Â Â Â Â Â Â 13mA typical, 15mA maximum
32V DC          11mA typical, 12mA maximumPower Supply Effect: Less than ±0.001% of output span effect per volt DC of supply change.
Isolation
Inputs isolated from each other (channel-to-channel) and from output/power.
Peak: 1500V AC, ANSI/ISA-82.01-1988.
Continuous: 250V AC, 354V DC.Shock and Vibration Immunity
Vibration: 4g, per IEC 60068-2-64.
Shock: 25g, per IEC 60068-2-27.Electromagnetic Compatibility (EMC) Compliance
Radiated Emissions: BS EN 61000-6-4, CISPR 16.
RFI: BS EN 61000-6-2, IEC 61000-4-3.
Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6.
ESD: BS EN 61000-6-2, IEC 61000-4-2.
EFT: BS EN 61000-6-2, IEC 61000-4-4.
Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5.Approvals
CE compliant. UL/cUL listings. ATEX Certified.
Designed for Class I; Division 2; Groups ABCD; Zone 2.Physical
General: General purpose plastic enclosure for mounting on 35mm “T-type” DIN rail.
Case Material: Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General purpose NEMA Type 1 enclosure.
Circuit Board: Military grade fire-retardant epoxy glass per IPC-4101/98 with humi-seal conformal coating.
I/O Connectors: Removable plug-in type terminal blocks rated for 12A/250V; AWG #26-12, stranded/solid copper wire.
Dimensions
Width = 22.5mm (0.9 inches).
Length = 114.5mm (4.51 inches).
Depth = 99.0mm (3.90 inches).Shipping Weight: 0.5 pounds (0.22 Kg) packed.
-
Features & Benefits
- Input ranges: 0-130V RMS, 130V DC
- Output ranges: Open-Drain with 1K Ohm pull-up to 5.3V DC; 0-32V DC Maximum, 150mA sink
- Power Requirement: 12 to 32V DC (0.4W)
- Six high-level voltage input channels
- Six logic-level output channels (open-drain, low-side switches)
- Built-in hysteresis optimized for mains power at 120Vrms
- Outputs include 1KΩ pull-ups to 5.3V DC
- High-density 22.5mm wide package with pluggable, front-facing terminals
- 1500V AC isolation (between each input and power/output) and surge/transient protection
- Supports bussed/rail and redundant power
- -40°C to 70°C wide temperature operation
- Withstands 25g shock and 4g vibration
- CE and UL/cUL Class 1 Div 2 Zone 2 approvals
- ATEX Certified
-
Specs & Data Sheets
Specs & Catalogs
Manuals
XTA-120V-6 User Manual (Log in to download the file)
-
Additional information
Additional information
Weight 8 oz Dimensions 4.5 × 1.5 × 5 in Part Number XTA-120V-6: 6-channel 120V AC/DC discrete input with 5V DC logic outputs
Product Series XTA Series