XT1210: 8-Channel Differential Analog Current Input Module
Please sign in or register to see model options and to add products to your cart.
Product short description:
- 0-11mA, 0-20mA, 4-20mA, ±20mA, or 0-20 amps AC Input
- 8 analog differential current input channels
- 12 to 32V DC Power (2.8W)
- Modbus TCP/IP, Ethernet/IP, Profinet
- i2o® peer-to-peer available for Modbus TCP/IP only
The XT1210 offers an isolated Ethernet network interface for up to eight differential current input channels. Isolated differential inputs deliver better measurements, superior noise rejection, and eliminate the need for current loop isolators.
- Description
- Features & Benefits
- Tech Papers
- Specs & Data Sheets
- Software
- Accessories
- Additional information
XT1210: 8-Channel Differential Analog Current Input Ethernet Module Description
The XT1210 offers an isolated Ethernet network interface for up to eight differential current input channels.
Isolated differential inputs deliver better measurements, superior noise rejection, and eliminate the need for current loop isolators.
Rugged construction, high density design, and easy USB-to-PC/Windows setup combine for a very effective and reliable module.
These units are ideal for remote monitoring, distributed control, or SCADA applications.
Input Ranges
0 to 11mA, 0 to 20mA, 4 to 20mA, ±20mA.
0 to 20 amps AC (with optional AC sensor).
Ethernet Communication
Modbus TCP/IP, i2o® peer-to-peer available for Modbus TCP/IP only.
Ethernet/IP.
Profinet.
10/100Base-T(X) PriorityChannel™ device determinism.
Power Requirement: 12 to 32V DC (2.8W).
Learn more about the Ethernet XT Series and view all models >
XT1210: 8-Channel Differential Analog Current Input Ethernet Module Performance Specifications
IMPORTANT: To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends use of the USB-ISOLATOR when configuring an XT1000 I/O module.
USB Interface
USB Connector
Type: USB Mini-B type socket, 5-pin.
Data Rate: 12Mbps. USB v1.1 and 2.0 compatible.
Cable Length: 5.0 meters maximum.
USB Transient Protection: Transient voltage suppression on power and data lines.
Driver: Not required. Uses Windows (HID) drivers.
Input
Accuracy: ±0.05% of span, typical for nominal input ranges.
Analog to Digital Converter (A/D): 16-bit Σ-Δ converter. 1.476uA/bit resolution.
Noise Rejection: Better than -110dB @ 60Hz.
Input Filter Bandwidth: -3dB at 25KHz, typical.
Input Conversion Rate: 10ms for all 8 input channels.
Input Impedance: 27.4 ohms
Ethernet Communication
Protocols
Modbus TCP/IP, i2o® peer-to-peer available for Modbus TCP/IP only.
Ethernet/IP or Profinet, depending on model number.
Ethernet Communication Controller: Innovasic RapID™ Platform with PriorityChannel™ for determinism at the device regardless of network load.
Modbus TCP/IP (slave): Port 502 reserved. Supports up to 10 sockets.
i2o Peer-to-Peer (master/slave): Can map each of 8 analog input channels separately to output channels. Timed (1-65535 sec) or percent-of-change updates. Supports GPRS/GSM systems.
Ethernet/IP (adapter): Supports 10 connections. EDS file on website.
Profinet (server): Supports 1 connection. GSDML file on website.
Connectors: Two shielded 8-pin RJ-45 sockets, 10BaseT/100BaseTX.
Wiring: Auto-crossover for MDI or MDI-X.
IP Address: User-configurable. 192.168.1.100 default IP address.
Data Rate: Auto-negotiated, 10Mbps or 100Mbps.
Compliance: IEEE 802.3, 802.3u, 802.3x.
Environmental
Operating temperature: -40 to 70°C (-40 to 158°F).
Storage temperature: -40 to 85°C (-40 to 185°F).
Relative humidity: 5 to 95% non-condensing.
MTBF
478,854 hrs. at 25°C.
359,078 hrs. at 40°C.
Power Requirement: 12 to 32V DC, 2.8W maximum (116mA maximum @ 24V).
Isolation
4-way isolation between I/O channels, network (each port), and power.
Peak: 1500V AC, ANSI/ISA-82.01-1988.
Continuous: 250V AC, 354V DC.
Shock and Vibration Immunity
Vibration: 4g, per IEC 60068-2-64.
Shock: 25g, per IEC 60068-2-27.
Electromagnetic Compatibility (EMC) Compliance
Radiated Emissions: BS EN 61000-6-4, CISPR 16.
RFI: BS EN 61000-6-2, IEC 61000-4-3.
Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6.
ESD: BS EN 61000-6-2, IEC 61000-4-2.
EFT: BS EN 61000-6-2, IEC 61000-4-4.
Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5.
Approvals: CE compliant. UL/cUL listed. Designed for Class I; Division 2; Groups ABCD; Zone 2. ATEX Certified.
Physical
General: General purpose plastic enclosure for mounting on 35mm “T-type” DIN rail.
Case Material: Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General purpose NEMA Type 1 enclosure.
Circuit Board: Military grade fire-retardant epoxy glass (IPC-4101/98).
I/O Connectors: Removable plug-in type terminal blocks rated for 12A/250V; AWG #26-12, stranded/solid copper wire.
Dimensions
Width = 22.5mm (0.9 inches).
Length = 114.5mm (4.51 inches).
Depth = 99.0mm (3.90 inches).
Shipping Weight: 0.5 pounds (0.22 Kg) packed.
Learn more about the Ethernet XT Series and view all models >
- i2o® peer-to-peer available for Modbus TCP/IP only
- i2o® peer-to-peer updates based on change-of-state and/or timed updates
- Easy setup with Windows software via USB
- Low input impedance (27 ohms) reduces loading on current loops
- User-configurable sample averaging (1-200) on a per-channel basis
- 10ms network updates for all 8 input channels
- High-resolution 16-bit Σ∆ A/D converter ensures precise, high accuracy measurements
- High-Density 22.5mm wide package with pluggable, front-facing terminals
- Dual Ethernet 10/100 ports (auto-negotiation) reduce switch port requirements
- 1500V AC isolation (between I/O, power, and network ports) and surge/transient protection
- Supports bussed/rail and redundant power
- -40°C to 70°C wide temperature operation
- Withstands 25g shock and 4g vibration
- CE compliant. UL/cUL Class 1 Div 2 Zone 2 approvals
- ATEX Certified
Specifications
Manuals
Brochure
Drawings & Diagrams
-
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
-
5035 Series: Ethernet Cables
- Ethernet straight cable, CAT5
- Ethernet crossover cable, CAT5E
- Low EMI Double-Shielded Ethernet Patch Cable
-
XT-SIP: Software Interface Package
- Software Interface Package for BusWorks XT Series Ethernet I/O modules.
- Easy setup and digital calibration via USB with Windows configuration software
- Download software only from the Software Tab below
Additional information
Weight | 8 oz |
---|---|
Dimensions | 4.5 × 1.5 × 5 in |
Part Number | XT1211-000: Modbus TCP/IP and i2o protocol, XT1212-000: Ethernet/IP protocol, XT1213-000: Profinet protocol |
Product Series | BusWorks XT Series |
Communication | Ethernet/IP, i2o Peer-to-Peer, Modbus TCP/IP, Profinet |
Configuration | USB Configuration, Windows Software Configuration |
-
Description
XT1210: 8-Channel Differential Analog Current Input Ethernet Module Description
The XT1210 offers an isolated Ethernet network interface for up to eight differential current input channels.
Isolated differential inputs deliver better measurements, superior noise rejection, and eliminate the need for current loop isolators.
Rugged construction, high density design, and easy USB-to-PC/Windows setup combine for a very effective and reliable module.
These units are ideal for remote monitoring, distributed control, or SCADA applications.
Input Ranges
0 to 11mA, 0 to 20mA, 4 to 20mA, ±20mA.
0 to 20 amps AC (with optional AC sensor).Ethernet Communication
Modbus TCP/IP, i2o® peer-to-peer available for Modbus TCP/IP only.
Ethernet/IP.
Profinet.
10/100Base-T(X) PriorityChannel™ device determinism.Power Requirement: 12 to 32V DC (2.8W).
Learn more about the Ethernet XT Series and view all models >
XT1210: 8-Channel Differential Analog Current Input Ethernet Module Performance Specifications
IMPORTANT: To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends use of the USB-ISOLATOR when configuring an XT1000 I/O module.
USB Interface
USB Connector
Type: USB Mini-B type socket, 5-pin.
Data Rate: 12Mbps. USB v1.1 and 2.0 compatible.
Cable Length: 5.0 meters maximum.
USB Transient Protection: Transient voltage suppression on power and data lines.
Driver: Not required. Uses Windows (HID) drivers.
Input
Accuracy: ±0.05% of span, typical for nominal input ranges.
Analog to Digital Converter (A/D): 16-bit Σ-Δ converter. 1.476uA/bit resolution.
Noise Rejection: Better than -110dB @ 60Hz.
Input Filter Bandwidth: -3dB at 25KHz, typical.
Input Conversion Rate: 10ms for all 8 input channels.
Input Impedance: 27.4 ohms
Ethernet Communication
Protocols
Modbus TCP/IP, i2o® peer-to-peer available for Modbus TCP/IP only.
Ethernet/IP or Profinet, depending on model number.Ethernet Communication Controller: Innovasic RapID™ Platform with PriorityChannel™ for determinism at the device regardless of network load.
Modbus TCP/IP (slave): Port 502 reserved. Supports up to 10 sockets.
i2o Peer-to-Peer (master/slave): Can map each of 8 analog input channels separately to output channels. Timed (1-65535 sec) or percent-of-change updates. Supports GPRS/GSM systems.
Ethernet/IP (adapter): Supports 10 connections. EDS file on website.
Profinet (server): Supports 1 connection. GSDML file on website.
Connectors: Two shielded 8-pin RJ-45 sockets, 10BaseT/100BaseTX.
Wiring: Auto-crossover for MDI or MDI-X.
IP Address: User-configurable. 192.168.1.100 default IP address.
Data Rate: Auto-negotiated, 10Mbps or 100Mbps.
Compliance: IEEE 802.3, 802.3u, 802.3x.
Environmental
Operating temperature: -40 to 70°C (-40 to 158°F).
Storage temperature: -40 to 85°C (-40 to 185°F).
Relative humidity: 5 to 95% non-condensing.
MTBF
478,854 hrs. at 25°C.
359,078 hrs. at 40°C.Power Requirement: 12 to 32V DC, 2.8W maximum (116mA maximum @ 24V).
Isolation
4-way isolation between I/O channels, network (each port), and power.
Peak: 1500V AC, ANSI/ISA-82.01-1988.
Continuous: 250V AC, 354V DC.Shock and Vibration Immunity
Vibration: 4g, per IEC 60068-2-64.
Shock: 25g, per IEC 60068-2-27.Electromagnetic Compatibility (EMC) Compliance
Radiated Emissions: BS EN 61000-6-4, CISPR 16.
RFI: BS EN 61000-6-2, IEC 61000-4-3.
Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6.
ESD: BS EN 61000-6-2, IEC 61000-4-2.
EFT: BS EN 61000-6-2, IEC 61000-4-4.
Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5.Approvals: CE compliant. UL/cUL listed. Designed for Class I; Division 2; Groups ABCD; Zone 2. ATEX Certified.
Physical
General: General purpose plastic enclosure for mounting on 35mm “T-type” DIN rail.
Case Material: Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General purpose NEMA Type 1 enclosure.
Circuit Board: Military grade fire-retardant epoxy glass (IPC-4101/98).
I/O Connectors: Removable plug-in type terminal blocks rated for 12A/250V; AWG #26-12, stranded/solid copper wire.
Dimensions
Width = 22.5mm (0.9 inches).
Length = 114.5mm (4.51 inches).
Depth = 99.0mm (3.90 inches).Shipping Weight: 0.5 pounds (0.22 Kg) packed.
Learn more about the Ethernet XT Series and view all models >
-
Features & Benefits
- i2o® peer-to-peer available for Modbus TCP/IP only
- i2o® peer-to-peer updates based on change-of-state and/or timed updates
- Easy setup with Windows software via USB
- Low input impedance (27 ohms) reduces loading on current loops
- User-configurable sample averaging (1-200) on a per-channel basis
- 10ms network updates for all 8 input channels
- High-resolution 16-bit Σ∆ A/D converter ensures precise, high accuracy measurements
- High-Density 22.5mm wide package with pluggable, front-facing terminals
- Dual Ethernet 10/100 ports (auto-negotiation) reduce switch port requirements
- 1500V AC isolation (between I/O, power, and network ports) and surge/transient protection
- Supports bussed/rail and redundant power
- -40°C to 70°C wide temperature operation
- Withstands 25g shock and 4g vibration
- CE compliant. UL/cUL Class 1 Div 2 Zone 2 approvals
- ATEX Certified
-
Tech Papers
How to Communicate with Acromag Ethernet/IP Modules from CompactLogix Controllers - 8500762Communicating with Acromag Series 9xxEN-60xx, XTxxx2-xxx, and NTE2xxx-xxxx Ethernet/IP™ Modules from CompactLogix™ PLC Device This document illustrates a procedure for configuring message commands intended for Acromag Busworks® Series Ethernet/IP modules using Ladder Logic programming software in addition to a CompactLogix Programmable Controller. It is assumed that the user has a working knowledge of; Ladder Logic...How to Monitor Pump Performance with a Panel PC, HMI & Ethernet I/O - 8400954How to Monitor Pump Performance with a Panel PC, HMI & Ethernet I/O Defining the Problem: Pumps are integral to a wide variety of both industries and processes. When you monitor pump performance, you can lower operating costs, improve process throughput, and reduce downtime and schedule maintenance. An automation system is needed with local displaying...How to Communicate with Modbus/TCP Modules from Ignition Software - 8501121Setting Up and Communicating with Acromag Series 9xxEN-40xx and XTxxx1-xxx Modbus/TCP Modules and EtherStax™ Modbus/TCP from Ignition Software This document illustrates a procedure for configuring OPC tags intended for Acromag BusWorks® Series Modbus/TCP modules using Windows software from Inductive Automation. It is assumed that the user has a working knowledge of OPC, Modbus TCP, and...How to Save Money Using i2o Over Cellular Networks - 8400921Minimizing Costs When Transmitting Data Over Cellular Networks How to Save Money Using i2o Over Cellular Networks: Acromag has a peer-to-peer technology called i2o. It allows two or more modules to talk to each other; without a network master or special software. Additionally, i2o operates over any standard Ethernet media; Cat 5 or 6 copper,...How to Network Remote Gas Detectors with Ethernet I/O - 8400852Network Remote Gas Detectors with Ethernet I/O Defining the Problem: In a wastewater treatment plant, remotely mounted gas detectors monitoring Methane CH4 (ceiling), Oxygen O2 (6 ft high) and Hydrogen Sulfide H2S (floor) have analog outputs. The gas levels need to be saved to chart recorders located in a control room a long distance away...How to Record Building Water Usage with Remote Ethernet I/O - 8400841Record Building Water Usage with Remote Ethernet I/O This document illustrates using Acromag’s XT1211 discrete I/O modules to communicate via Modbus TCP/IP and aid in monitoring the usage and quality of water used by a school. Defining the Problem: Regulatory Compliance – To meet environmental standards by monitoring the usage and quality of water used by a school....How to Connect to Acromag Ethernet I/O Devices - 8500815Getting Connected to Acromag Ethernet I/O Devices These instructions summarize the basic steps you will have to take in order to initially connect an Acromag Ethernet I/O product to your Personal Computer (PC) or laptop. To connect an Ethernet device to your PC, consult with your network administrator. Either temporarily change the TCP/IP configuration of...How to Communicate with Ethernet XT Profinet from Siemens S7-1200 PLC - 8501007Communicating with Acromag Model XTxxx3-000 Profinet I/O Modules from a Siemens S7-1200 PLC EthernetXT Profinet and Siemens S7-1200 When setting up a Profinet network, Profinet controllers are programmed with a special Profinet Configuration tool, like the Step7 from Siemens. This document illustrates an example procedure for configuring communications between Acromag BusWorks® Series Profinet modules and...How to Communicate to Ethernet Modules from Red Lion HMIs - 8500874How to Communicate to Acromag Ethernet Modules from Red Lion HMIs Red Lion HMIs This document illustrates a procedure for configuring message commands for Acromag Ethernet modules using the Red Lion Crimson 2.0 software. It is assumed that the user has a working knowledge of the Crimson 2.0 software, as well as a Red Lion... -
Specs & Data Sheets
Specifications
Manuals
Brochure
Drawings & Diagrams
-
Software
XT-SIP: Software Interface Information Page (Log in to download the file)Ethernet XT Series Configuration Software (Log in to download the file)ESW-MBLIB: Ethernet Modbus C Library Software Information Page (Log in to download the file)AMTx: Modbus TCP/IP Software Information Page (Log in to download the file)Profinet GSDML Files for XTxxx3-000 Modules (Log in to download the file)Ethernet IP EDS For XTxxx2-000 Modules (Log in to download the file) -
Accessories
-
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
-
5035 Series: Ethernet Cables
- Ethernet straight cable, CAT5
- Ethernet crossover cable, CAT5E
- Low EMI Double-Shielded Ethernet Patch Cable
-
XT-SIP: Software Interface Package
- Software Interface Package for BusWorks XT Series Ethernet I/O modules.
- Easy setup and digital calibration via USB with Windows configuration software
- Download software only from the Software Tab below
-
-
Additional information
Additional information
Weight 8 oz Dimensions 4.5 × 1.5 × 5 in Part Number XT1211-000: Modbus TCP/IP and i2o protocol, XT1212-000: Ethernet/IP protocol, XT1213-000: Profinet protocol
Product Series BusWorks XT Series
Communication Ethernet/IP, i2o Peer-to-Peer, Modbus TCP/IP, Profinet
Configuration USB Configuration, Windows Software Configuration
Please login to submit this form.