Signal Converters and Process Transmitters
Process signal transmitters and signal converters isolate, filter, amplify, and convert sensor signals to 4-20mA current or 0-10V signals for interfacing with controllers and other instrumentation. Select from 2-wire loop-powered 4-20mA transmitters, or 4-wire AC/DC-powered transmitters. Acromag offers 3- and 4-wire models with 4-20mA transmitters or voltage transmitters. DIN-rail and field-mount versions are available. Process transmitter configuration is easy with Windows® software, Agility® mobile app pushbuttons, switches, or pots for span/zero settings, depending on the series.Showing 17–32 of 61 results
-
611T, 612T: Single or Dual Channel, DC Voltage/Current Input, DC-Powered Transmitters
- ±100V DC, 0 to 100mA DC, 0 to 20A AC (with optional sensor) input
- 0 to 20mA, 0 to 10V DC output
- 10-36V DC power
- Universal DC I/O transmitters with auto-configuration and self-ranging capabilities
-
651T, 652T: Multi-Channel, Two-Wire Isolators
- DC current input
- Single/dual-channel DC-powered isolators
-
654T: Dual DC Voltage Input, Loop-powered Transmitter
- 2 channels, ±625mV, 0-10V DC (selectable ranges) input
- 4 to 20mA DC output
- 12-50V DC power from output loop
- Dual-channel transmitter with push-button calibration
-
655T, 656T: Single or Dual Channel, Thermocouple/milliVolt Input, Loop-powered Transmitter
- TC (types J, K T, R, S, E, B, N), ±1V DC, selectable range/type input
- 4 to 20mA DC output
- 12-50V DC from output loop power
- DIP-switch configuration, signal linearizer, push-button calibration
-
657T, 658T: Single or Dual Channel, RTD Input, Loop-powered Transmitter
- 100 ohm Pt, 120 ohm Ni, 10 ohm Cu (selectable type) input
- 4 to 20mA DC output
- 12-50V DC from output loop power
- DIP-switch configuration, push-button calibration
-
800C-SIP: IntelliPack Configuration Software
- Configuration Software
- USB-to-RS232 Adapter
- RS232-to-RJ11 Adapter
- Interface Cable
-
801T: Universal Input Intelligent Temperature Transmitter
- Thermocouple, RTD, milliVolt, and Resistance Input
- 0 to 20mA DC, 0 to 10V DC output
- Limit Alarm
- 10-36V DC power
- Software configured
- Performs linearization, square root extraction, and optional limit alarm functions
-
811A, 812A: Intelligent Alarm; DC Voltage/Current Input
- ±100V or 0 to 22mA DC input ranges or 2 input channels, ±100V or 0 to 22mA DC input ranges (AC current with optional sensor)
- Single or dual mechanical relays
- 10-36V DC power
- Software configured; multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection); on/off controller capability
-
811T: DC Voltage/Current Input Intelligent Transmitter
- ±100V or 0 to 22mA DC input ranges (AC current with optional sensor)
- 0 to 20mA DC, 0 to 10V DC output
- Mechanical relay alarm (25V @ 5A)
- 10-36V DC power
- Software configured, performs linearization, square root extraction, and optional limit alarm functions
-
841T: DC Frequency/Pulse Input Intelligent Transmitter
- 0 to 50KHz, 0 to 65535 pulses input
- 0 to 20mA DC, 0 to 10V DC output
- Mechanical alarm relay (25V @ 5A)
- 10-36V DC power
- Software configured; pulse counter; signal averaging; optional limit alarm functions
-
ACC1014: Flat Pack Mounting Kit
- Surface mount for 250T, 260A and 270i series
- Snaptrack mount 250T, 260A and 270i series
-
APM765 Series: Universal Input with Alarm Panel Meter
- Universal input
- Isolated 4-20mA and Modbus output options
- Push-button or PC programmable,
- 85-265V AC or 90-265V DC power, optional 12-24V AC or 12-36V DC power
-
DIN Rail: Type T
- DIN Rail Strip, Type T
-
DT230-Config/Cal: Calibration Service
- Factory custom configuration/calibration service.
- Specify input type, input/output, zero, full-scale values, filtering, and sensor fault settings* on order.
-
DT330-Config/Cal: Calibration Service
- Factory custom configuration/calibration service.
- Specify input type, input/output, zero, full-scale values, filtering, and sensor fault settings* on order.
Signal Conditioners, Transmitters and Converters Continued

Acromag high-performance signal conditioner products include process transmitters, 4-20mA signal isolators, limit alarms, signal splitters, and math computation modules. These products isolate, amplify, filter, condition, and convert measured signals from sensors and other instruments. The enhanced signal is ready for interfacing to your PLC, DCS, display, recorder, or other process control instrumentation.
Temperature transmitters convert thermocouple, RTD, and low-level temperature sensor signals to 4-20mA, 0-10V, or other DC voltage/current outputs. Acromag offers temperature transmitters in head-mount and DIN-rail form factors. Some temperature transmitters have software-configured universal input to convert a broad range of temperature sensor and other signals with a single unit.
See all signal conditioners and transmitters to choose the best solution for your application.
Signal Conditioning Functions:
- Signal converter, linearizer, averager
- Integrator, totalizer
- Pulse counter, frequency measurement
- Arithmetic calculation, Boolean logic
- Limit alarm relay trip, window range, deviation, rate-of-change, peak/valley detection
Learn More About Transmitters