Signal Converters and Process Transmitters

Process signal transmitters and signal converters isolate, filter, amplify, and convert sensor signals to 4-20mA current or 0-10V signals for interfacing with controllers and other instrumentation. Select from 2-wire loop-powered 4-20mA transmitters, or 4-wire AC/DC-powered transmitters. Acromag offers 3- and 4-wire models with 4-20mA transmitters or voltage transmitters. DIN-rail and field-mount versions are available. Process transmitter configuration is easy with Windows® software, Agility® mobile app pushbuttons, switches, or pots for span/zero settings, depending on the series.
  • Compare

    611T, 612T: Single or Dual Channel, DC Voltage/Current Input, DC-Powered Transmitters

    • ±100V DC, 0 to 100mA DC, 0 to 20A AC (with optional sensor) input
    • 0 to 20mA, 0 to 10V DC output
    • 10-36V DC power
    • Universal DC I/O transmitters with auto-configuration and self-ranging capabilities
    These units receive DC current or voltage input signals, provide isolation, and output proportional DC current or voltage signals. With support for universal DC I/O ranges, 610T series transmitters provide a solution for a wide variety of isolation and signal conversion tasks.
    Select options This product has multiple variants. The options may be chosen on the product page
  • Compare

    651T, 652T: Multi-Channel, Two-Wire Isolators

    • DC current input
    • Single/dual-channel DC-powered isolators
    These units receive 4-20mA process current inputs and provide isolated 4-20mA output signals. Each channel operates independently and is isolated from the others to prevent interaction between channels.
    Select options This product has multiple variants. The options may be chosen on the product page
  • Compare

    654T: Dual DC Voltage Input, Loop-powered Transmitter

    • 2 channels, ±625mV, 0-10V DC (selectable ranges) input
    • 4 to 20mA DC output
    • 12-50V DC power from output loop
    • Dual-channel transmitter with push-button calibration
    These units accept DC voltage input signals, provide isolation, and output proportional DC current signals.
    Select options This product has multiple variants. The options may be chosen on the product page
  • Compare

    655T, 656T: Single or Dual Channel, Thermocouple/milliVolt Input, Loop-powered Transmitter

    • TC (types J, K T, R, S, E, B, N), ±1V DC, selectable range/type input
    • 4 to 20mA DC output
    • 12-50V DC from output loop power
    • DIP-switch configuration, signal linearizer, push-button calibration
    These units accept universal thermocouple and millivolt input signals, provide isolation, and output proportional DC current signals. The output can also be linearized to the input sensor signal.  
    Select options This product has multiple variants. The options may be chosen on the product page
  • Compare

    657T, 658T: Single or Dual Channel, RTD Input, Loop-powered Transmitter

    • 100 ohm Pt, 120 ohm Ni, 10 ohm Cu (selectable type) input
    • 4 to 20mA DC output
    • 12-50V DC from output loop power
    • DIP-switch configuration, push-button calibration
    These units accept universal RTD or resistance input signals and output proportional DC current signals. The output can also be linearized to the input sensor signal.
    Select options This product has multiple variants. The options may be chosen on the product page
  • Compare

    800C-SIP: IntelliPack Configuration Software

    • Configuration Software
    • USB-to-RS232 Adapter
    • RS232-to-RJ11 Adapter
    • Interface Cable
    Acromag’s configuration software is the key to the IntelliPack’s easy-to-use operation. The software employs the friendly Windows® interface with pull-down selection menus and fill-in-the-blank fields to speed you through a few brief configuration screens. No programming is required.
    Select options This product has multiple variants. The options may be chosen on the product page
  • Compare

    801T: Universal Input Intelligent Temperature Transmitter

    • Thermocouple, RTD, milliVolt, and Resistance Input
    • 0 to 20mA DC, 0 to 10V DC output
    • Limit Alarm
    • 10-36V DC power
    • Software configured
    • Performs linearization, square root extraction, and optional limit alarm functions
    These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.
    Select options This product has multiple variants. The options may be chosen on the product page
  • Compare

    811A, 812A: Intelligent Alarm; DC Voltage/Current Input

    • ±100V or 0 to 22mA DC input ranges or 2 input channels, ±100V or 0 to 22mA DC input ranges (AC current with optional sensor)
    • Single or dual mechanical relays
    • 10-36V DC power
    • Software configured; multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection); on/off controller capability
    IntelliPack alarms compare inputs against user-defined limit set-points to control built-in relays.  
    Select options This product has multiple variants. The options may be chosen on the product page
  • Compare

    811T: DC Voltage/Current Input Intelligent Transmitter

    • ±100V or 0 to 22mA DC input ranges (AC current with optional sensor)
    • 0 to 20mA DC, 0 to 10V DC output
    • Mechanical relay alarm (25V @ 5A)
    • 10-36V DC power
    • Software configured, performs linearization, square root extraction, and optional limit alarm functions
    These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.
    Select options This product has multiple variants. The options may be chosen on the product page
  • Compare

    841T: DC Frequency/Pulse Input Intelligent Transmitter

    • 0 to 50KHz, 0 to 65535 pulses input
    • 0 to 20mA DC, 0 to 10V DC output
    • Mechanical alarm relay (25V @ 5A)
    • 10-36V DC power
    • Software configured; pulse counter; signal averaging; optional limit alarm functions
    These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.
    Select options This product has multiple variants. The options may be chosen on the product page
  • Compare

    ACC1014: Flat Pack Mounting Kit

    • Surface mount for 250T, 260A and 270i series
    • Snaptrack mount 250T, 260A and 270i series
    Select options This product has multiple variants. The options may be chosen on the product page
  • Compare

    Agility™ Config Tool (Tethered)

    • Tethered Agility™ Config Tool mobile application
    • For Acromag SP Series Signal Splitters and most TT Series Transmitters
    • Download available on Google Play for free.
    • Download Windows configuration software from the software tab below.
    Read more
  • Compare

    APM765 Series: Universal Input with Alarm Panel Meter

    • Universal input
    • Isolated 4-20mA and Modbus output options
    • Push-button or PC programmable,
    • 85-265V AC or 90-265V DC power, optional 12-24V AC or 12-36V DC power
    The APM765 displays data collected from process current, DC voltage and temperature inputs. Several output options convert the display into a transmitter with proportional 4-20mA output or a serial communication interface.
    Select options This product has multiple variants. The options may be chosen on the product page
  • Compare

    DIN Rail: Type T

    • DIN Rail Strip, Type T
    Select options This product has multiple variants. The options may be chosen on the product page
  • Compare

    DT230-Config/Cal: Calibration Service

    • Factory custom configuration/calibration service.
    • Specify input type, input/output, zero, full-scale values, filtering, and sensor fault settings* on order.
    * Sensor fault settings are available for models DT233, DT235, DT333 and DT335.
    Select options This product has multiple variants. The options may be chosen on the product page
  • Compare

    DT330-Config/Cal: Calibration Service

    • Factory custom configuration/calibration service.
    • Specify input type, input/output, zero, full-scale values, filtering, and sensor fault settings* on order.
    * Sensor fault settings are available for models: DT233, DT235, DT333 and DT335.
    Select options This product has multiple variants. The options may be chosen on the product page

Signal Conditioners, Transmitters and Converters Continued

Green Separator Line

Acromag high-performance signal conditioner products include process transmitters4-20mA signal isolatorslimit alarmssignal splitters, and math computation modules. These products isolate, amplify, filter, condition, and convert measured signals from sensors and other instruments. The enhanced signal is ready for interfacing to your PLC, DCS, display, recorder, or other process control instrumentation.

Temperature transmitters convert thermocouple, RTD, and low-level temperature sensor signals to 4-20mA, 0-10V, or other DC voltage/current outputs. Acromag offers temperature transmitters in head-mount and DIN-rail form factors. Some temperature transmitters have software-configured universal input to convert a broad range of temperature sensor and other signals with a single unit.

See all signal conditioners and transmitters to choose the best solution for your application.

Signal Conditioning Functions:

  • Signal converter, linearizer, averager
  • Integrator, totalizer
  • Pulse counter, frequency measurement
  • Arithmetic calculation, Boolean logic
  • Limit alarm relay trip, window range, deviation, rate-of-change, peak/valley detection

Learn More About Transmitters

As your I/O experts, Acromag is here to help! Below are our most popular whitepapers related to our Signal Conditioning products. Find more application notes, white papers and support here: https://www.acromag.com/support/