Product short description:
  • ±100V or 0 to 22mA DC input ranges (AC current with optional sensor)
  • 0 to 20mA DC, 0 to 10V DC output
  • Mechanical relay alarm (25V @ 5A)
  • 10-36V DC power
  • Software configured, performs linearization, square root extraction, and optional limit alarm functions

These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.

811T: DC Voltage/Current Input Intelligent Transmitter Description

These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.

Each unit offers a selection of input and output ranges, as well as several signal conditioning options. This flexibility enables a single IntelliPack to handle a broad range of applications. As your needs change, you can easily reconfigure the unit for different ranges or functions.

Setup is very easy. IntelliPack modules are quickly configured with the user-friendly Windows software program. Field adjustments are simple with the module’s front-panel push-buttons and status LEDs. Once configured, IntelliPacks operate independent of any host computer.

Performance

General Input

Analog to Digital Converter (ADC): 16-bit Σ-Δ A/D converter.

Ambient Temperature Effect: Better than ±0.005% of input span per °C or ±1μV, whichever is greater.

Noise Rejection:
Normal Mode: Better than 40dB @ 60Hz.
Common Mode: Better than 100dB @ 60Hz.

Input Response Time (for input step change): Less than 100mS typical to 98% of final output value.

Input Over-voltage Protection: Bipolar Transient Voltage Suppressors (TVS).

DC Current Input

DC Current Input Ranges (100% rangeable):
Input Ranges          Resolution

0 to 22mA DC                  757nA
0 to 5mA DC                    189nA

DC Current Input Impedance: 24.9 ohms.

Excitation Supply (for 2-wire instruments): +15V DC, 24mA maximum.

DC Current Input Accuracy: better than ±0.05% of input span.

DC Voltage Input

DC Voltage Input Ranges (100% rangeable):
Input Ranges          Resolution

±100V DC                       3.77mV
±50V DC                         1.88mV
±25V DC                           942μV
±12V DC                            471μV
±6V DC                             236μV
±3V DC                              118μV

Input impedance: Greater than 500K ohms.

DC Voltage Input Accuracy: better than ±0.05% of input span.

AC Current Input

AC Current Input Range (optional): An optional external AC current sensor is required to monitor AC current signals (Model 5020-350).

AC Current Range          Primary Turns
0 to 20A AC                                       1
0 to 10A AC                                       2
0 to 5A AC                                         4
0 to 2A AC                                       10
0 to 1A AC                                       20

AC Current Input Accuracy: better than ±0.05% of input span.

Output (DC V/mA)

D/A Converter: 16-bit Σ-Δ.

Current Output:
0-1mA, 0-20mA, 4-20mA.
Compliance: 10V minimum (500 ohm load).
Accuracy: 0.025% of span.

Voltage Output:
Ranges: 0-5V, 0-10V.
Compliance: 10mA maximum with short circuit protection. 1 ohm output impedance.
Accuracy: 0.025% of span.

Accuracy (overall input to output): 0.075% of span.

Output (Relay)

Relay: One SPDT electro-mechanical relay.

Relay Ratings (CSA ratings):
25V DC @ 5A.
120/240V AC @ 5A.

Relay Time Delay: Adjustable alarm delay of up to 25 seconds.

Contact Material: Silver-cadmium oxide (AgCdO).

Expected Mechanical Life: 20 million operations.

Environmental

Ambient Temperature:
Operating: -25 to 70°C (-13 to 158°F).
Storage: -40 to 85°C (-40 to 185°F).

Relative Humidity: 5 to 95%.

Power Requirements: 10 to 36V DC. 110mA @ 24V. 170mA @ 15V.

Isolation (optical):
4-way (input/output/relay/power).
1500V AC for 60 seconds or 250V AC continuous.

Radiated Field Immunity (RFI): EN61000-4-3, EN50082-1.

Electromagnetic Field Immunity (EMI):
Less than ±0.25% of output span effect under the influence of electromagnetic fields from switching solenoids, commutator motors, and drill motors.

Electrical Fast Transient (EFT): EN61000-4-4, EN50082-1.

Surge Withstanding Capability (SWC): EN61000-4-5, EN50082-1.

Electrostatic Discharge (ESD): EN61000-4-2, EN50082-1.

Radiated Emissions: EN50081-1 for Class B equipment.

Approvals: UL listed (USA, Canada).

Configuration

Software Configuration: Units are fully programmable via the Windows 7 or newer IntelliPack Configuration Program. Configuration downloads from PC through EIA232 serial port using Acromag 800C-SIP kit.

Field Configuration: Output, zero/full-scale, relay setpoint and deadband are configurable via push-buttons and a standard calibrator.

LED Indicators: LEDs indicate power, status, calibration, and alarm.

Physical

Enclosure: Case: Self-extinguishing NYLON type 6.6 polyamide thermoplastic UL94 V-2, color beige; general purpose NEMA Type 1 enclosure.

Connectors (Removable terminal blocks): Wire Range: AWG #14-22 (AWG #12 stranded only).

Printed Circuit Boards: Military grade FR-4 epoxy glass circuit board.

Dimensions
1.05W x 4.68H x 4.35D inches.
26.7W x 118.9H x 110.5D millimeters.

Shipping Weight: 1 pound (0.45 Kg) packed.

  • High-resolution Sigma-Delta A/D converter delivers high accuracy with low noise
  • Advanced micro-controller provides intelligent signal processing power for linearization,averaging, and square root computations
  • Windows 7 or newer software configuration speeds setup and replacement
  • Multi-purpose inputs and outputs reduce spare stock requirements
  • Relay output option provides local limit alarm capability
How to Create a 4-20mA Output Proportional to Flow Rate - 8400304
Problem: A flow sensor has a non-linear reversed output. Solution: Create a 4-20mA output proportional to flow rate using the following Acromag transmitter and software products: Model: 811T-0500 DC to DC Isolated Transmitter Model: 800C-SIP Software Interface Package Optional: PS5R-D24 Power Supply The 811T offers a 25 break-point table for sensor linearization. Input percentage is...

Manuals

811T User Manual (Log in to download the file)

IntelliPack Transmitter Configuration Software User Manual Model 5030-881 (Log in to download the file)

800C-SIP: IntelliPack Configuration Software Information Page (Log in to download the file)
IntelliPack Configuration Software 5030-881 (Log in to download the file)
  • Compare

    800C-SIP: IntelliPack Configuration Software

    • Configuration Software
    • USB-to-RS232 Adapter
    • RS232-to-RJ11 Adapter
    • Interface Cable
    Acromag’s configuration software is the key to the IntelliPack’s easy-to-use operation. The software employs the friendly Windows® interface with pull-down selection menus and fill-in-the-blank fields to speed you through a few brief configuration screens. No programming is required.
    Select options
  • Compare

    PS5R: Slim Line Power Supplies

    • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
    • Universal Input (85-264V AC / 100-370V DC)
    • Lightweight and compact size
     
    Select options

Additional information

Weight 8 oz
Dimensions 5 × 1.25 × 4.5 in
Part Number

811T-0500: Transmitter, 811T-0500-C: Transmitter with factory configuration, 811T-1500: Transmitter, limit alarm with relay, 811T-1500-C: Transmitter, limit alarm with relay, with factory configuration.

Configuration

Windows Software Configuration

Product Series

IntelliPack 800 Series

Power

DC Power, External Power

  • Description

    811T: DC Voltage/Current Input Intelligent Transmitter Description

    These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.

    Each unit offers a selection of input and output ranges, as well as several signal conditioning options. This flexibility enables a single IntelliPack to handle a broad range of applications. As your needs change, you can easily reconfigure the unit for different ranges or functions.

    Setup is very easy. IntelliPack modules are quickly configured with the user-friendly Windows software program. Field adjustments are simple with the module’s front-panel push-buttons and status LEDs. Once configured, IntelliPacks operate independent of any host computer.

    Performance

    General Input

    Analog to Digital Converter (ADC): 16-bit Σ-Δ A/D converter.

    Ambient Temperature Effect: Better than ±0.005% of input span per °C or ±1μV, whichever is greater.

    Noise Rejection:
    Normal Mode: Better than 40dB @ 60Hz.
    Common Mode: Better than 100dB @ 60Hz.

    Input Response Time (for input step change): Less than 100mS typical to 98% of final output value.

    Input Over-voltage Protection: Bipolar Transient Voltage Suppressors (TVS).

    DC Current Input

    DC Current Input Ranges (100% rangeable):
    Input Ranges          Resolution

    0 to 22mA DC                  757nA
    0 to 5mA DC                    189nA

    DC Current Input Impedance: 24.9 ohms.

    Excitation Supply (for 2-wire instruments): +15V DC, 24mA maximum.

    DC Current Input Accuracy: better than ±0.05% of input span.

    DC Voltage Input

    DC Voltage Input Ranges (100% rangeable):
    Input Ranges          Resolution

    ±100V DC                       3.77mV
    ±50V DC                         1.88mV
    ±25V DC                           942μV
    ±12V DC                            471μV
    ±6V DC                             236μV
    ±3V DC                              118μV

    Input impedance: Greater than 500K ohms.

    DC Voltage Input Accuracy: better than ±0.05% of input span.

    AC Current Input

    AC Current Input Range (optional): An optional external AC current sensor is required to monitor AC current signals (Model 5020-350).

    AC Current Range          Primary Turns
    0 to 20A AC                                       1
    0 to 10A AC                                       2
    0 to 5A AC                                         4
    0 to 2A AC                                       10
    0 to 1A AC                                       20

    AC Current Input Accuracy: better than ±0.05% of input span.

    Output (DC V/mA)

    D/A Converter: 16-bit Σ-Δ.

    Current Output:
    0-1mA, 0-20mA, 4-20mA.
    Compliance: 10V minimum (500 ohm load).
    Accuracy: 0.025% of span.

    Voltage Output:
    Ranges: 0-5V, 0-10V.
    Compliance: 10mA maximum with short circuit protection. 1 ohm output impedance.
    Accuracy: 0.025% of span.

    Accuracy (overall input to output): 0.075% of span.

    Output (Relay)

    Relay: One SPDT electro-mechanical relay.

    Relay Ratings (CSA ratings):
    25V DC @ 5A.
    120/240V AC @ 5A.

    Relay Time Delay: Adjustable alarm delay of up to 25 seconds.

    Contact Material: Silver-cadmium oxide (AgCdO).

    Expected Mechanical Life: 20 million operations.

    Environmental

    Ambient Temperature:
    Operating: -25 to 70°C (-13 to 158°F).
    Storage: -40 to 85°C (-40 to 185°F).

    Relative Humidity: 5 to 95%.

    Power Requirements: 10 to 36V DC. 110mA @ 24V. 170mA @ 15V.

    Isolation (optical):
    4-way (input/output/relay/power).
    1500V AC for 60 seconds or 250V AC continuous.

    Radiated Field Immunity (RFI): EN61000-4-3, EN50082-1.

    Electromagnetic Field Immunity (EMI):
    Less than ±0.25% of output span effect under the influence of electromagnetic fields from switching solenoids, commutator motors, and drill motors.

    Electrical Fast Transient (EFT): EN61000-4-4, EN50082-1.

    Surge Withstanding Capability (SWC): EN61000-4-5, EN50082-1.

    Electrostatic Discharge (ESD): EN61000-4-2, EN50082-1.

    Radiated Emissions: EN50081-1 for Class B equipment.

    Approvals: UL listed (USA, Canada).

    Configuration

    Software Configuration: Units are fully programmable via the Windows 7 or newer IntelliPack Configuration Program. Configuration downloads from PC through EIA232 serial port using Acromag 800C-SIP kit.

    Field Configuration: Output, zero/full-scale, relay setpoint and deadband are configurable via push-buttons and a standard calibrator.

    LED Indicators: LEDs indicate power, status, calibration, and alarm.

    Physical

    Enclosure: Case: Self-extinguishing NYLON type 6.6 polyamide thermoplastic UL94 V-2, color beige; general purpose NEMA Type 1 enclosure.

    Connectors (Removable terminal blocks): Wire Range: AWG #14-22 (AWG #12 stranded only).

    Printed Circuit Boards: Military grade FR-4 epoxy glass circuit board.

    Dimensions
    1.05W x 4.68H x 4.35D inches.
    26.7W x 118.9H x 110.5D millimeters.

    Shipping Weight: 1 pound (0.45 Kg) packed.

  • Features & Benefits

    • High-resolution Sigma-Delta A/D converter delivers high accuracy with low noise
    • Advanced micro-controller provides intelligent signal processing power for linearization,averaging, and square root computations
    • Windows 7 or newer software configuration speeds setup and replacement
    • Multi-purpose inputs and outputs reduce spare stock requirements
    • Relay output option provides local limit alarm capability
  • Tech Papers

    How to Create a 4-20mA Output Proportional to Flow Rate - 8400304
    Problem: A flow sensor has a non-linear reversed output. Solution: Create a 4-20mA output proportional to flow rate using the following Acromag transmitter and software products: Model: 811T-0500 DC to DC Isolated Transmitter Model: 800C-SIP Software Interface Package Optional: PS5R-D24 Power Supply The 811T offers a 25 break-point table for sensor linearization. Input percentage is...
  • Specs & Data Sheets

    Manuals

    811T User Manual (Log in to download the file)

    IntelliPack Transmitter Configuration Software User Manual Model 5030-881 (Log in to download the file)

  • Software

    800C-SIP: IntelliPack Configuration Software Information Page (Log in to download the file)
    IntelliPack Configuration Software 5030-881 (Log in to download the file)
  • Accessories

    • Compare

      800C-SIP: IntelliPack Configuration Software

      • Configuration Software
      • USB-to-RS232 Adapter
      • RS232-to-RJ11 Adapter
      • Interface Cable
      Acromag’s configuration software is the key to the IntelliPack’s easy-to-use operation. The software employs the friendly Windows® interface with pull-down selection menus and fill-in-the-blank fields to speed you through a few brief configuration screens. No programming is required.
      Select options
    • Compare

      PS5R: Slim Line Power Supplies

      • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
      • Universal Input (85-264V AC / 100-370V DC)
      • Lightweight and compact size
       
      Select options
  • Additional information

    Additional information

    Weight 8 oz
    Dimensions 5 × 1.25 × 4.5 in
    Part Number

    811T-0500: Transmitter, 811T-0500-C: Transmitter with factory configuration, 811T-1500: Transmitter, limit alarm with relay, 811T-1500-C: Transmitter, limit alarm with relay, with factory configuration.

    Configuration

    Windows Software Configuration

    Product Series

    IntelliPack 800 Series

    Power

    DC Power, External Power