Click to zoom
$375$520
Clear
Product short description:
  • 0 to 20mA DC, 0 to 10V DC output
  • Mechanical relay (25V @ 5A) alarm
  • 10-36V DC power
  • Software configured
  • Performs linearization, square root extraction, and optional limit alarm functions

These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.

 

[DISPLAY_ULTIMATE_PLUS]

801T Universal Input Intelligent Temperature Transmitter Description

These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.

Each unit offers a selection of input and output ranges, as well as several signal conditioning options. This flexibility enables a single IntelliPack to handle a broad range of applications. As your needs change, you can easily reconfigure the unit for different ranges or functions.

Setup is very easy. IntelliPack modules are quickly configured with the user-friendly Windows software program. Field adjustments are simple with the module’s front-panel push-buttons and status LEDs. Once configured, IntelliPacks operate independent of any host computer.

Performance

General Input

Analog to Digital (A/D) Converter: 16-bit Σ-Δ A/D converter
Resolution: ±0.005% of span or 0.1°C
Ambient Temperature Effect: Better than ±0.005% of input span per °C or ±1μV, whichever is greater.
Noise Rejection:
Normal Mode: Better than 40dB @ 60Hz
Common Mode: Better than 130dB @ 60Hz
Input Response Time (for input step change): Less than 200mS typical to 98% of final output value
Input Over-voltage Protection: Bipolar Transient Voltage Suppressors (TVS)

Thermocouple Input

Thermocouple Input Ranges
Thermocouple type user configured. Signal linearization, cold-junction compensation, and open circuit or lead break detection are included.
TC             °C Range (°F Range)                     Accuracy
J        -210 to  760°C (-346 to 1400°F)              ±0.5°C
K       -200 to 1372°C (-328 to 2502°F)             ±0.5°C
T       -260 to  400°C (-436 to 752°F)                 ±0.5°C
R         -50 to 1768°C (-58 to 3214°F)                ±1.0°C
S         -50 to 1768°C (-58 to 3214°F)                ±1.0°C
E       -200 to 1000°C (-328 to 1832°F)             ±0.5°C
B        260 to 1820°C (500 to 3308°F)               ±1.0°C
N      -230 to 1300°C (-382 to 2372°F)             ±1.0°C

Thermocouple Break Detection: TC sensor failure can be configured for either upscale or downscale

RTD Input

RTD Input Ranges:100 ohm Platinum, 120 ohm Nickel, or 10 ohm Copper; user-configured

RTD                °C Range (°F Range)                       Accuracy
Pt1            -200 to 850°C (-328 to 1562°F)              ±0.25°C
Pt2            -200 to 850°C (-328 to 1562°F)              ±0.25°C
Ni                 -80 to 320°C (-112 to 608°F)                 ±0.25°C
Cu             -200 to 260°C (-328 to 500°F)                 ±1.00°C
Alpha: Pt1 (a = 1.3850), Pt2 (a = 1.3911), Ni (a = 1.6720), Cu (a = 1.4272)
2, 3, or 4-wire configurations supported. Module provides sensor excitation, linearization, lead-wire compensation, and sensor break detection.

RTD Excitation Current:
1mA DC typical, all types
RTD Lead-Wire Compensation: 25 ohms per lead
RTD Break Detection: RTD sensor failure can be configured for either upscale or downscale.

milliVolt Input

DC milliVolt/Voltage Input Ranges: 
±1.0V           ±125mV          ±31.25mV
±500mV     ±62.5mV        ±15.625mV       ±250mV

milliVolt Accuracy: better than ±0.05% of input span

Resistance Input

Resistance Input Range: 0 to 500 ohms
Resistance Accuracy: ±0.05 ohms

Output (DC V/mA)

D/A Converter: 16-bit Σ-Δ
Current Output:
0-1mA, 0-20mA, 4-20mA
Compliance: 10V minimum (500 ohm load)
Accuracy: 0.025% of span
Voltage Output:
Ranges: 0-5V, 0-10V
Compliance: 10mA maximum with short circuit protection. 1 ohm output impedance
Accuracy: 0.025% of span
Accuracy (overall input to output): 0.075% of span

Output (Relay)

Relay: One SPDT electro-mechanical relay
Relay Ratings (CSA ratings):
25V DC @ 5A
120/240V AC @ 5A
Relay Time Delay: Adjustable alarm delay of up to 25 seconds
Contact Material: Silver-cadmium oxide (AgCdO)
Expected Mechanical Life: 20 million operations

Environmental

Ambient Temperature:
Operating: -25 to 70°C (-13 to 158°F)
Storage: -40 to 85°C (-40 to 185°F)
Relative Humidity: 5 to 95%
Power Requirements: 10 to 36V DC. 75mA @ 24V. 120mA @ 15V
Isolation (optical):
4-way (input/output/relay/power)
1500V AC for 60 seconds or 250V AC continuous
Radiated Field Immunity (RFI): EN61000-4-3, EN50082-1
Electromagnetic Field Immunity (EMI):
Less than ±0.25% of output span effect under the influence of electromagnetic fields from switching solenoids, commutator motors, and drill motors.
Electrical Fast Transient (EFT): EN61000-4-4, EN50082-1
Surge Withstanding Capability (SWC): EN61000-4-5, EN50082-1
Electrostatic Discharge (ESD): EN61000-4-2, EN50082-1
Radiated Emissions: EN50081-1 for Class B equipment
Approvals:
UL, cUL listed (USA, Canada)
UL3121 – general product safety

Configuration

Software Configuration: Units are fully programmable via the Windows 7 or newer IntelliPack Configuration Program. Configuration downloads from PC through EIA232 serial port using Acromag 800C-SIP kit.
Field Configuration: Output, zero/full-scale, relay setpoint and deadband are configurable via push-buttons and a standard calibrator.
LED Indicators: LEDs indicate power, status, calibration, and alarm.

Physical

Enclosure: Case: Self-extinguishing NYLON type 6.6 polyamide thermoplastic UL94 V-2, color beige; general purpose NEMA Type 1 enclosure.
Connectors (Removable terminal blocks): Wire Range: AWG #14-22 (AWG #12 stranded only)
Printed Circuit Boards: Military grade FR-4 epoxy glass circuit board
Dimensions
1.05W x 4.68H x 4.35D inches
26.7W x 118.9H x 110.5D millimeters
Shipping Weight: 1 pound (0.45 Kg) packed

 

  • High-resolution Sigma-Delta A/D converter delivers high accuracy with low noise.
  • Advanced micro-controller provides intelligent signal processing power for linearization, averaging, and square root computations.
  • Windows 7 or newer software configuration speeds setup and replacement.
  • Multi-purpose inputs and outputs reduce spare stock requirements.
  • Relay output option provides local limit alarm capability.

 

How to use Thermocouple Transmitters to Monitor Temperatures in Paint Systems Application Note
This document illustrates using Acromag’s TT330 Series to monitor high temperatures in an automotive paint curing oven and transmit to the existing PLC 4-20mA input card/software setup. Defining the Problem The area around an auto manufacturer’s paint curing ovens is at elevated temperatures affecting the performance of locally installed instrumentation. Placing Signal Conditioners rated for...
How to Use Temperature Transmitters to Optimize Solar Panel Performance Application Note
Monitoring Weather Conditions Helps Optimize Performance of Utility-Scale Solar Panel Arrays Swinerton Renewable Energy has selected weather stations from Columbia Weather Systems to provide meteorological data to their proprietary SCADA system at solar project sites. The construction company offers turn-key solar power solutions for utility-scale and distributed generation projects. Joe Brotherton, manager of the technical...
Temperature Measurement Using Thermocouples White Paper (Log in to view the file)
The Basics of Temperature Measurement Using Thermocouples Choosing a temperature sensor for an application is not as simple as picking a thermocouple type with a compatible temperature range. You must give consideration to the sensor material type, the application temperature range, the relative sensitivity of the sensor, the limitations of its insulation material, and its...
Temperature Measurement Using RTDs White Paper (Log in to view the file)
The Basics of Temperature Measurement Using RTDs Temperature reigns as the most often measured process parameter in industry. Most industrial applications require that a temperature be measured remotely, and that this signal be transmitted some distance. An industrial transmitter is commonly used to amplify, isolate, and convert the low-level sensor signal to a high level...

Manuals

801T User Manual (Log in to download the file)

IntelliPack Transmitter Configuration Software User Manual Model 5030-881 (Log in to download the file)

How to Use SIIG USB-to-Serial Cable With Windows Tech Note (Log in to download the file)

IntelliPack Configuration Software 5030-881 (Log in to download the file)
  • Compare

    20RM-16-DIN: 19” rack-mount kit with DIN rail

    • 19" rack-mount kit with DIN rail
    $185
    Select options
  • Compare

    4001-095: USB-to-Serial Adapter

    • USB-to-serial adapter
    • Easy to use to setup and re-configure modules
    $40
    Select options
  • Compare

    5030 Cable Series

    • Various specialty cables
    $20$90
    Select options
  • Compare

    5030-881

    • IntelliPack 800 Series software on CD-ROM
    $60
    Select options
  • Compare

    800C-SIP: IntelliPack Configuration Software

    • Configuration Software
    • USB-to-RS232 Adapter
    • RS232-to-RJ11 Adapter
    • Interface Cable
         
    $300
    Select options
  • Compare

    PS5R: Slim Line Power Supplies

    • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
    • Universal Input (85-264V AC / 100-370V DC)
    • Lightweight and compact size
    $95$245
    Select options
  • Compare

    Terminal Block Replacements

    • Simplifies wiring connections on Acromag I/O Modules
    • Barrier strip or spring clamp terminal block kits
    • Provide safe and secure wiring connections
    $30$40
    Select options

Additional information

Weight 11 oz
Dimensions 5 × 1.25 × 4.5 in
Part Number

801T-0500: Transmitter, 801T-0500-C: factory configuration, 801T-1500: limit alarm with relay, 801T-1500-C: limit alarm with relay and factory configuration

Configuration

Windows Software Configuration

Product Series

IntelliPack 800 Series

Power

DC Power, External Power

  • Description

    801T Universal Input Intelligent Temperature Transmitter Description

    These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.

    Each unit offers a selection of input and output ranges, as well as several signal conditioning options. This flexibility enables a single IntelliPack to handle a broad range of applications. As your needs change, you can easily reconfigure the unit for different ranges or functions.

    Setup is very easy. IntelliPack modules are quickly configured with the user-friendly Windows software program. Field adjustments are simple with the module’s front-panel push-buttons and status LEDs. Once configured, IntelliPacks operate independent of any host computer.

    Performance

    General Input

    Analog to Digital (A/D) Converter: 16-bit Σ-Δ A/D converter
    Resolution: ±0.005% of span or 0.1°C
    Ambient Temperature Effect: Better than ±0.005% of input span per °C or ±1μV, whichever is greater.
    Noise Rejection:
    Normal Mode: Better than 40dB @ 60Hz
    Common Mode: Better than 130dB @ 60Hz
    Input Response Time (for input step change): Less than 200mS typical to 98% of final output value
    Input Over-voltage Protection: Bipolar Transient Voltage Suppressors (TVS)

    Thermocouple Input

    Thermocouple Input Ranges
    Thermocouple type user configured. Signal linearization, cold-junction compensation, and open circuit or lead break detection are included.
    TC             °C Range (°F Range)                     Accuracy
    J        -210 to  760°C (-346 to 1400°F)              ±0.5°C
    K       -200 to 1372°C (-328 to 2502°F)             ±0.5°C
    T       -260 to  400°C (-436 to 752°F)                 ±0.5°C
    R         -50 to 1768°C (-58 to 3214°F)                ±1.0°C
    S         -50 to 1768°C (-58 to 3214°F)                ±1.0°C
    E       -200 to 1000°C (-328 to 1832°F)             ±0.5°C
    B        260 to 1820°C (500 to 3308°F)               ±1.0°C
    N      -230 to 1300°C (-382 to 2372°F)             ±1.0°C

    Thermocouple Break Detection: TC sensor failure can be configured for either upscale or downscale

    RTD Input

    RTD Input Ranges:100 ohm Platinum, 120 ohm Nickel, or 10 ohm Copper; user-configured

    RTD                °C Range (°F Range)                       Accuracy
    Pt1            -200 to 850°C (-328 to 1562°F)              ±0.25°C
    Pt2            -200 to 850°C (-328 to 1562°F)              ±0.25°C
    Ni                 -80 to 320°C (-112 to 608°F)                 ±0.25°C
    Cu             -200 to 260°C (-328 to 500°F)                 ±1.00°C
    Alpha: Pt1 (a = 1.3850), Pt2 (a = 1.3911), Ni (a = 1.6720), Cu (a = 1.4272)
    2, 3, or 4-wire configurations supported. Module provides sensor excitation, linearization, lead-wire compensation, and sensor break detection.

    RTD Excitation Current:
    1mA DC typical, all types
    RTD Lead-Wire Compensation: 25 ohms per lead
    RTD Break Detection: RTD sensor failure can be configured for either upscale or downscale.

    milliVolt Input

    DC milliVolt/Voltage Input Ranges: 
    ±1.0V           ±125mV          ±31.25mV
    ±500mV     ±62.5mV        ±15.625mV       ±250mV

    milliVolt Accuracy: better than ±0.05% of input span

    Resistance Input

    Resistance Input Range: 0 to 500 ohms
    Resistance Accuracy: ±0.05 ohms

    Output (DC V/mA)

    D/A Converter: 16-bit Σ-Δ
    Current Output:
    0-1mA, 0-20mA, 4-20mA
    Compliance: 10V minimum (500 ohm load)
    Accuracy: 0.025% of span
    Voltage Output:
    Ranges: 0-5V, 0-10V
    Compliance: 10mA maximum with short circuit protection. 1 ohm output impedance
    Accuracy: 0.025% of span
    Accuracy (overall input to output): 0.075% of span

    Output (Relay)

    Relay: One SPDT electro-mechanical relay
    Relay Ratings (CSA ratings):
    25V DC @ 5A
    120/240V AC @ 5A
    Relay Time Delay: Adjustable alarm delay of up to 25 seconds
    Contact Material: Silver-cadmium oxide (AgCdO)
    Expected Mechanical Life: 20 million operations

    Environmental

    Ambient Temperature:
    Operating: -25 to 70°C (-13 to 158°F)
    Storage: -40 to 85°C (-40 to 185°F)
    Relative Humidity: 5 to 95%
    Power Requirements: 10 to 36V DC. 75mA @ 24V. 120mA @ 15V
    Isolation (optical):
    4-way (input/output/relay/power)
    1500V AC for 60 seconds or 250V AC continuous
    Radiated Field Immunity (RFI): EN61000-4-3, EN50082-1
    Electromagnetic Field Immunity (EMI):
    Less than ±0.25% of output span effect under the influence of electromagnetic fields from switching solenoids, commutator motors, and drill motors.
    Electrical Fast Transient (EFT): EN61000-4-4, EN50082-1
    Surge Withstanding Capability (SWC): EN61000-4-5, EN50082-1
    Electrostatic Discharge (ESD): EN61000-4-2, EN50082-1
    Radiated Emissions: EN50081-1 for Class B equipment
    Approvals:
    UL, cUL listed (USA, Canada)
    UL3121 – general product safety

    Configuration

    Software Configuration: Units are fully programmable via the Windows 7 or newer IntelliPack Configuration Program. Configuration downloads from PC through EIA232 serial port using Acromag 800C-SIP kit.
    Field Configuration: Output, zero/full-scale, relay setpoint and deadband are configurable via push-buttons and a standard calibrator.
    LED Indicators: LEDs indicate power, status, calibration, and alarm.

    Physical

    Enclosure: Case: Self-extinguishing NYLON type 6.6 polyamide thermoplastic UL94 V-2, color beige; general purpose NEMA Type 1 enclosure.
    Connectors (Removable terminal blocks): Wire Range: AWG #14-22 (AWG #12 stranded only)
    Printed Circuit Boards: Military grade FR-4 epoxy glass circuit board
    Dimensions
    1.05W x 4.68H x 4.35D inches
    26.7W x 118.9H x 110.5D millimeters
    Shipping Weight: 1 pound (0.45 Kg) packed

     

  • Features & Benefits

    • High-resolution Sigma-Delta A/D converter delivers high accuracy with low noise.
    • Advanced micro-controller provides intelligent signal processing power for linearization, averaging, and square root computations.
    • Windows 7 or newer software configuration speeds setup and replacement.
    • Multi-purpose inputs and outputs reduce spare stock requirements.
    • Relay output option provides local limit alarm capability.

     

  • Tech Papers

    How to use Thermocouple Transmitters to Monitor Temperatures in Paint Systems Application Note
    This document illustrates using Acromag’s TT330 Series to monitor high temperatures in an automotive paint curing oven and transmit to the existing PLC 4-20mA input card/software setup. Defining the Problem The area around an auto manufacturer’s paint curing ovens is at elevated temperatures affecting the performance of locally installed instrumentation. Placing Signal Conditioners rated for...
    How to Use Temperature Transmitters to Optimize Solar Panel Performance Application Note
    Monitoring Weather Conditions Helps Optimize Performance of Utility-Scale Solar Panel Arrays Swinerton Renewable Energy has selected weather stations from Columbia Weather Systems to provide meteorological data to their proprietary SCADA system at solar project sites. The construction company offers turn-key solar power solutions for utility-scale and distributed generation projects. Joe Brotherton, manager of the technical...
    Temperature Measurement Using Thermocouples White Paper (Log in to view the file)
    The Basics of Temperature Measurement Using Thermocouples Choosing a temperature sensor for an application is not as simple as picking a thermocouple type with a compatible temperature range. You must give consideration to the sensor material type, the application temperature range, the relative sensitivity of the sensor, the limitations of its insulation material, and its...
    Temperature Measurement Using RTDs White Paper (Log in to view the file)
    The Basics of Temperature Measurement Using RTDs Temperature reigns as the most often measured process parameter in industry. Most industrial applications require that a temperature be measured remotely, and that this signal be transmitted some distance. An industrial transmitter is commonly used to amplify, isolate, and convert the low-level sensor signal to a high level...
  • Specs & Data Sheets

    Manuals

    801T User Manual (Log in to download the file)

    IntelliPack Transmitter Configuration Software User Manual Model 5030-881 (Log in to download the file)

    How to Use SIIG USB-to-Serial Cable With Windows Tech Note (Log in to download the file)

  • Software

    IntelliPack Configuration Software 5030-881 (Log in to download the file)
  • Accessories

    • Compare

      20RM-16-DIN: 19” rack-mount kit with DIN rail

      • 19" rack-mount kit with DIN rail
      $185
      Select options
    • Compare

      4001-095: USB-to-Serial Adapter

      • USB-to-serial adapter
      • Easy to use to setup and re-configure modules
      $40
      Select options
    • Compare

      5030 Cable Series

      • Various specialty cables
      $20$90
      Select options
    • Compare

      5030-881

      • IntelliPack 800 Series software on CD-ROM
      $60
      Select options
    • Compare

      800C-SIP: IntelliPack Configuration Software

      • Configuration Software
      • USB-to-RS232 Adapter
      • RS232-to-RJ11 Adapter
      • Interface Cable
           
      $300
      Select options
    • Compare

      PS5R: Slim Line Power Supplies

      • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
      • Universal Input (85-264V AC / 100-370V DC)
      • Lightweight and compact size
      $95$245
      Select options
    • Compare

      Terminal Block Replacements

      • Simplifies wiring connections on Acromag I/O Modules
      • Barrier strip or spring clamp terminal block kits
      • Provide safe and secure wiring connections
      $30$40
      Select options
  • Additional information

    Additional information

    Weight 11 oz
    Dimensions 5 × 1.25 × 4.5 in
    Part Number

    801T-0500: Transmitter, 801T-0500-C: factory configuration, 801T-1500: limit alarm with relay, 801T-1500-C: limit alarm with relay and factory configuration

    Configuration

    Windows Software Configuration

    Product Series

    IntelliPack 800 Series

    Power

    DC Power, External Power