801T: Universal Input Intelligent Temperature Transmitter
Product short description:
- 0 to 20mA DC, 0 to 10V DC output
- Mechanical relay (25V @ 5A) alarm
- 10-36V DC power
- Software configured
- Performs linearization, square root extraction, and optional limit alarm functions
These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.
- Description
- Features & Benefits
- Tech Papers
- Specs & Data Sheets
- Software
- Accessories
- Additional information
801T Universal Input Intelligent Temperature Transmitter Description
These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.
Each unit offers a selection of input and output ranges, as well as several signal conditioning options. This flexibility enables a single IntelliPack to handle a broad range of applications. As your needs change, you can easily reconfigure the unit for different ranges or functions.
Setup is very easy. IntelliPack modules are quickly configured with the user-friendly Windows software program. Field adjustments are simple with the module’s front-panel push-buttons and status LEDs. Once configured, IntelliPacks operate independent of any host computer.
Performance
General Input
Analog to Digital (A/D) Converter: 16-bit Σ-Δ A/D converter
Resolution: ±0.005% of span or 0.1°C
Ambient Temperature Effect: Better than ±0.005% of input span per °C or ±1μV, whichever is greater.
Noise Rejection:
Normal Mode: Better than 40dB @ 60Hz
Common Mode: Better than 130dB @ 60Hz
Input Response Time (for input step change): Less than 200mS typical to 98% of final output value
Input Over-voltage Protection: Bipolar Transient Voltage Suppressors (TVS)
Thermocouple Input
Thermocouple Input Ranges
Thermocouple type user configured. Signal linearization, cold-junction compensation, and open circuit or lead break detection are included.
TC       °C Range (°F Range)           Accuracy
J    -210 to 760°C (-346 to 1400°F)       ±0.5°C
K    -200 to 1372°C (-328 to 2502°F)       ±0.5°C
T    -260 to 400°C (-436 to 752°F)         ±0.5°C
R     -50 to 1768°C (-58 to 3214°F)        ±1.0°C
S     -50 to 1768°C (-58 to 3214°F)        ±1.0°C
E    -200 to 1000°C (-328 to 1832°F)       ±0.5°C
B    260 to 1820°C (500 to 3308°F)        ±1.0°C
N   -230 to 1300°C (-382 to 2372°F)       ±1.0°C
Thermocouple Break Detection: TC sensor failure can be configured for either upscale or downscale
RTD Input
RTD Input Ranges:100 ohm Platinum, 120 ohm Nickel, or 10 ohm Copper; user-configured
RTD        °C Range (°F Range)            Accuracy
Pt1      -200 to 850°C (-328 to 1562°F)       ±0.25°C
Pt2      -200 to 850°C (-328 to 1562°F)       ±0.25°C
Ni         -80 to 320°C (-112 to 608°F)         ±0.25°C
Cu       -200 to 260°C (-328 to 500°F)         ±1.00°C
Alpha: Pt1 (a = 1.3850), Pt2 (a = 1.3911), Ni (a = 1.6720), Cu (a = 1.4272)
2, 3, or 4-wire configurations supported. Module provides sensor excitation, linearization, lead-wire compensation, and sensor break detection.
RTD Excitation Current: 1mA DC typical, all types
RTD Lead-Wire Compensation: 25 ohms per lead
RTD Break Detection: RTD sensor failure can be configured for either upscale or downscale.
milliVolt Input
DC milliVolt/Voltage Input Ranges:Â
±1.0V      ±125mV     ±31.25mV
±500mV   ±62.5mV    ±15.625mV    ±250mV
milliVolt Accuracy: better than ±0.05% of input span
Resistance Input
Resistance Input Range: 0 to 500 ohms
Resistance Accuracy: ±0.05 ohms
Output (DC V/mA)
D/A Converter: 16-bit Σ-Δ
Current Output:
0-1mA, 0-20mA, 4-20mA
Compliance: 10V minimum (500 ohm load)
Accuracy: 0.025% of span
Voltage Output:
Ranges: 0-5V, 0-10V
Compliance: 10mA maximum with short circuit protection. 1 ohm output impedance
Accuracy: 0.025% of span
Accuracy (overall input to output): 0.075% of span
Output (Relay)
Relay: One SPDT electro-mechanical relay
Relay Ratings (CSA ratings):
25V DC @ 5A
120/240V AC @ 5A
Relay Time Delay: Adjustable alarm delay of up to 25 seconds
Contact Material: Silver-cadmium oxide (AgCdO)
Expected Mechanical Life: 20 million operations
Environmental
Ambient Temperature:
Operating: -25 to 70°C (-13 to 158°F)
Storage: -40 to 85°C (-40 to 185°F)
Relative Humidity: 5 to 95%
Power Requirements: 10 to 36V DC. 75mA @ 24V. 120mA @ 15V
Isolation (optical):
4-way (input/output/relay/power)
1500V AC for 60 seconds or 250V AC continuous
Radiated Field Immunity (RFI): EN61000-4-3, EN50082-1
Electromagnetic Field Immunity (EMI):
Less than ±0.25% of output span effect under the influence of electromagnetic fields from switching solenoids, commutator motors, and drill motors.
Electrical Fast Transient (EFT): EN61000-4-4, EN50082-1
Surge Withstanding Capability (SWC): EN61000-4-5, EN50082-1
Electrostatic Discharge (ESD): EN61000-4-2, EN50082-1
Radiated Emissions: EN50081-1 for Class B equipment
Approvals:
UL, cUL listed (USA, Canada)
UL3121 – general product safety
Configuration
Software Configuration: Units are fully programmable via the Windows 7 or newer IntelliPack Configuration Program. Configuration downloads from PC through EIA232 serial port using Acromag 800C-SIP kit.
Field Configuration: Output, zero/full-scale, relay setpoint and deadband are configurable via push-buttons and a standard calibrator.
LED Indicators: LEDs indicate power, status, calibration, and alarm.
Physical
Enclosure: Case: Self-extinguishing NYLON type 6.6 polyamide thermoplastic UL94 V-2, color beige; general purpose NEMA Type 1 enclosure.
Connectors (Removable terminal blocks): Wire Range: AWG #14-22 (AWG #12 stranded only)
Printed Circuit Boards: Military grade FR-4 epoxy glass circuit board
Dimensions
1.05W x 4.68H x 4.35D inches
26.7W x 118.9H x 110.5D millimeters
Shipping Weight: 1 pound (0.45 Kg) packed
- High-resolution Sigma-Delta A/D converter delivers high accuracy with low noise.
- Advanced micro-controller provides intelligent signal processing power for linearization, averaging, and square root computations.
- Windows 7 or newer software configuration speeds setup and replacement.
- Multi-purpose inputs and outputs reduce spare stock requirements.
- Relay output option provides local limit alarm capability.
Specifications
Manuals
Brochures
Drawings & Diagrams
-
20RM-16-DIN: 19” rack-mount kit with DIN rail
- 19" rack-mount kit with DIN rail
$185Select options -
4001-095: USB-to-Serial Adapter
- USB-to-serial adapter
- Easy to use to setup and re-configure modules
$40Select options -
800C-SIP: IntelliPack Configuration Software
- Configuration Software
- USB-to-RS232 Adapter
- RS232-to-RJ11 Adapter
- Interface Cable
$300Select options -
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
$95 – $245Select options -
Terminal Block Replacements
- Simplifies wiring connections on Acromag I/O Modules
- Barrier strip or spring clamp terminal block kits
- Provide safe and secure wiring connections
$30 – $40Select options
Additional information
Weight | 11 oz |
---|---|
Dimensions | 5 × 1.25 × 4.5 in |
Part Number | 801T-0500: Transmitter, 801T-0500-C: factory configuration, 801T-1500: limit alarm with relay, 801T-1500-C: limit alarm with relay and factory configuration |
Configuration | Windows Software Configuration |
Product Series | IntelliPack 800 Series |
Power | DC Power, External Power |
-
Description
801T Universal Input Intelligent Temperature Transmitter Description
These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.
Each unit offers a selection of input and output ranges, as well as several signal conditioning options. This flexibility enables a single IntelliPack to handle a broad range of applications. As your needs change, you can easily reconfigure the unit for different ranges or functions.
Setup is very easy. IntelliPack modules are quickly configured with the user-friendly Windows software program. Field adjustments are simple with the module’s front-panel push-buttons and status LEDs. Once configured, IntelliPacks operate independent of any host computer.
Performance
General Input
Analog to Digital (A/D) Converter: 16-bit Σ-Δ A/D converter
Resolution: ±0.005% of span or 0.1°C
Ambient Temperature Effect: Better than ±0.005% of input span per °C or ±1μV, whichever is greater.
Noise Rejection:
Normal Mode: Better than 40dB @ 60Hz
Common Mode: Better than 130dB @ 60Hz
Input Response Time (for input step change): Less than 200mS typical to 98% of final output value
Input Over-voltage Protection: Bipolar Transient Voltage Suppressors (TVS)Thermocouple Input
Thermocouple Input Ranges
Thermocouple type user configured. Signal linearization, cold-junction compensation, and open circuit or lead break detection are included.
TC       °C Range (°F Range)           Accuracy
J    -210 to 760°C (-346 to 1400°F)       ±0.5°C
K    -200 to 1372°C (-328 to 2502°F)       ±0.5°C
T    -260 to 400°C (-436 to 752°F)         ±0.5°C
R     -50 to 1768°C (-58 to 3214°F)        ±1.0°C
S     -50 to 1768°C (-58 to 3214°F)        ±1.0°C
E    -200 to 1000°C (-328 to 1832°F)       ±0.5°C
B    260 to 1820°C (500 to 3308°F)        ±1.0°C
N   -230 to 1300°C (-382 to 2372°F)       ±1.0°CThermocouple Break Detection: TC sensor failure can be configured for either upscale or downscale
RTD Input
RTD Input Ranges:100 ohm Platinum, 120 ohm Nickel, or 10 ohm Copper; user-configured
RTD        °C Range (°F Range)            Accuracy
Pt1      -200 to 850°C (-328 to 1562°F)       ±0.25°C
Pt2      -200 to 850°C (-328 to 1562°F)       ±0.25°C
Ni         -80 to 320°C (-112 to 608°F)         ±0.25°C
Cu       -200 to 260°C (-328 to 500°F)         ±1.00°C
Alpha: Pt1 (a = 1.3850), Pt2 (a = 1.3911), Ni (a = 1.6720), Cu (a = 1.4272)
2, 3, or 4-wire configurations supported. Module provides sensor excitation, linearization, lead-wire compensation, and sensor break detection.
RTD Excitation Current: 1mA DC typical, all types
RTD Lead-Wire Compensation: 25 ohms per lead
RTD Break Detection: RTD sensor failure can be configured for either upscale or downscale.milliVolt Input
DC milliVolt/Voltage Input Ranges:Â
±1.0V      ±125mV     ±31.25mV
±500mV   ±62.5mV    ±15.625mV    ±250mVmilliVolt Accuracy: better than ±0.05% of input span
Resistance Input
Resistance Input Range: 0 to 500 ohms
Resistance Accuracy: ±0.05 ohmsOutput (DC V/mA)
D/A Converter: 16-bit Σ-Δ
Current Output:
0-1mA, 0-20mA, 4-20mA
Compliance: 10V minimum (500 ohm load)
Accuracy: 0.025% of span
Voltage Output:
Ranges: 0-5V, 0-10V
Compliance: 10mA maximum with short circuit protection. 1 ohm output impedance
Accuracy: 0.025% of span
Accuracy (overall input to output): 0.075% of spanOutput (Relay)
Relay: One SPDT electro-mechanical relay
Relay Ratings (CSA ratings):
25V DC @ 5A
120/240V AC @ 5A
Relay Time Delay: Adjustable alarm delay of up to 25 seconds
Contact Material: Silver-cadmium oxide (AgCdO)
Expected Mechanical Life: 20 million operationsEnvironmental
Ambient Temperature:
Operating: -25 to 70°C (-13 to 158°F)
Storage: -40 to 85°C (-40 to 185°F)
Relative Humidity: 5 to 95%
Power Requirements: 10 to 36V DC. 75mA @ 24V. 120mA @ 15V
Isolation (optical):
4-way (input/output/relay/power)
1500V AC for 60 seconds or 250V AC continuous
Radiated Field Immunity (RFI): EN61000-4-3, EN50082-1
Electromagnetic Field Immunity (EMI):
Less than ±0.25% of output span effect under the influence of electromagnetic fields from switching solenoids, commutator motors, and drill motors.
Electrical Fast Transient (EFT): EN61000-4-4, EN50082-1
Surge Withstanding Capability (SWC): EN61000-4-5, EN50082-1
Electrostatic Discharge (ESD): EN61000-4-2, EN50082-1
Radiated Emissions: EN50081-1 for Class B equipment
Approvals:
UL, cUL listed (USA, Canada)
UL3121 – general product safetyConfiguration
Software Configuration: Units are fully programmable via the Windows 7 or newer IntelliPack Configuration Program. Configuration downloads from PC through EIA232 serial port using Acromag 800C-SIP kit.
Field Configuration: Output, zero/full-scale, relay setpoint and deadband are configurable via push-buttons and a standard calibrator.
LED Indicators: LEDs indicate power, status, calibration, and alarm.Physical
Enclosure: Case: Self-extinguishing NYLON type 6.6 polyamide thermoplastic UL94 V-2, color beige; general purpose NEMA Type 1 enclosure.
Connectors (Removable terminal blocks): Wire Range: AWG #14-22 (AWG #12 stranded only)
Printed Circuit Boards: Military grade FR-4 epoxy glass circuit board
Dimensions
1.05W x 4.68H x 4.35D inches
26.7W x 118.9H x 110.5D millimeters
Shipping Weight: 1 pound (0.45 Kg) packed -
Features & Benefits
- High-resolution Sigma-Delta A/D converter delivers high accuracy with low noise.
- Advanced micro-controller provides intelligent signal processing power for linearization, averaging, and square root computations.
- Windows 7 or newer software configuration speeds setup and replacement.
- Multi-purpose inputs and outputs reduce spare stock requirements.
- Relay output option provides local limit alarm capability.
-
Tech Papers
How to use Thermocouple Transmitters to Monitor Temperatures in Paint Systems Application NoteThis document illustrates using Acromag’s TT330 Series to monitor high temperatures in an automotive paint curing oven and transmit to the existing PLC 4-20mA input card/software setup. Defining the Problem The area around an auto manufacturer’s paint curing ovens is at elevated temperatures affecting the performance of locally installed instrumentation. Placing Signal Conditioners rated for...How to Use Temperature Transmitters to Optimize Solar Panel Performance Application NoteMonitoring Weather Conditions Helps Optimize Performance of Utility-Scale Solar Panel Arrays Swinerton Renewable Energy has selected weather stations from Columbia Weather Systems to provide meteorological data to their proprietary SCADA system at solar project sites. The construction company offers turn-key solar power solutions for utility-scale and distributed generation projects. Joe Brotherton, manager of the technical...Temperature Measurement Using Thermocouples White Paper (Log in to view the file)The Basics of Temperature Measurement Using Thermocouples Choosing a temperature sensor for an application is not as simple as picking a thermocouple type with a compatible temperature range. You must give consideration to the sensor material type, the application temperature range, the relative sensitivity of the sensor, the limitations of its insulation material, and its...Temperature Measurement Using RTDs White Paper (Log in to view the file)The Basics of Temperature Measurement Using RTDs Temperature reigns as the most often measured process parameter in industry. Most industrial applications require that a temperature be measured remotely, and that this signal be transmitted some distance. An industrial transmitter is commonly used to amplify, isolate, and convert the low-level sensor signal to a high level... -
Specs & Data Sheets
Specifications
Manuals
Brochures
Drawings & Diagrams
-
Software
IntelliPack Configuration Software 5030-881 (Log in to download the file) -
Accessories
-
20RM-16-DIN: 19” rack-mount kit with DIN rail
- 19" rack-mount kit with DIN rail
$185Select options -
4001-095: USB-to-Serial Adapter
- USB-to-serial adapter
- Easy to use to setup and re-configure modules
$40Select options -
800C-SIP: IntelliPack Configuration Software
- Configuration Software
- USB-to-RS232 Adapter
- RS232-to-RJ11 Adapter
- Interface Cable
$300Select options -
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
$95 – $245Select options -
Terminal Block Replacements
- Simplifies wiring connections on Acromag I/O Modules
- Barrier strip or spring clamp terminal block kits
- Provide safe and secure wiring connections
$30 – $40Select options
-
-
Additional information
Additional information
Weight 11 oz Dimensions 5 × 1.25 × 4.5 in Part Number 801T-0500: Transmitter, 801T-0500-C: factory configuration, 801T-1500: limit alarm with relay, 801T-1500-C: limit alarm with relay and factory configuration
Configuration Windows Software Configuration
Product Series IntelliPack 800 Series
Power DC Power, External Power
Related Items
-
800C-SIP: IntelliPack Configuration Software
- Configuration Software
- USB-to-RS232 Adapter
- RS232-to-RJ11 Adapter
- Interface Cable
$300Select options
Please login to submit this form.