Acromag signal conditioners and network I/O is ideal for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout.

Showing all 9 results

  • Compare

    611T, 612T: Single or Dual Channel, DC Voltage/Current Input, DC-Powered Transmitters

    • ±100V DC, 0 to 100mA DC, 0 to 20A AC (with optional sensor) input
    • 0 to 20mA, 0 to 10V DC output
    • 10-36V DC power
    • Universal DC I/O transmitters with auto-configuration and self-ranging capabilities
    These units receive DC current or voltage input signals, provide isolation, and output proportional DC current or voltage signals. With support for universal DC I/O ranges, 610T series transmitters provide a solution for a wide variety of isolation and signal conversion tasks. The single-channel 611T and dual-channel 612T are ideal for panel shops and end-users who require a high-density signal conditioner that can accommodate a broad range of instrumentation applications
    $275$475
    Read more
  • Compare

    631T, 632T: Single/Dual Channel Isolator

    • 4 to 20mA DC input
    • 4 to 20mA DC output
    • 12-36V DC SELV, 90-250V AC power
    • Single or dual I/O with a dual output model and full isolation
    These units receive 4-20mA process current inputs and provide isolated 4-20mA output signals. Each channel operates independently and is isolated from the others to prevent interaction between channels. Galvanic isolation eliminates ground loops, reduces noise, and blocks transient signals.
    $250$385
    Read more
  • Compare

    633T: AC/DC-Powered Signal Splitter

    • Single input, dual output (splitter)
    • 12-36V DC SELV, 90-250V AC
    • Provides two identical outputs from one input signal
    These units receive 4-20mA process current inputs and provide isolated 4-20mA output signals. Each channel operates independently and is isolated from the others to prevent interaction between channels. Galvanic isolation eliminates ground loops, reduces noise, and blocks transient signals.
    $310
    Read more
  • Compare

    651T, 652T: Multi-Channel, Two-Wire Isolators

    • DC current input
    • Single/dual-channel DC-powered isolators
    • Signal splitter
    These units receive 4-20mA process current inputs and provide isolated 4-20mA output signals. Each channel operates independently and is isolated from the others to prevent interaction between channels.
    $185$275
    Select options
  • Compare

    654T: Dual DC Voltage Input, Loop-powered Transmitter

    • 2 channels, ±625mV, 0-10V DC (selectable ranges) input
    • 4 to 20mA DC output
    • 12-50V DC power from output loop
    • Dual-channel transmitter with push-button calibration
    $365$420
    Select options
  • Compare

    655T, 656T: Single or Dual Channel, Thermocouple/milliVolt Input, Loop-powered Transmitter

    • TC (types J, K T, R, S, E, B, N), ±1V DC, selectable range/type input
    • 4 to 20mA DC output
    • 12-50V DC from output loop power
    • DIP-switch configuration, signal linearizer, push-button calibration
    $285$510
    Read more
  • Compare

    657T, 658T: Single or Dual Channel, RTD Input, Loop-powered Transmitter

    • 100 ohm Pt, 120 ohm Ni, 10 ohm Cu (selectable type) input
    • 4 to 20mA DC output
    • 12-50V DC from output loop power
    • DIP-switch configuration, push-button calibration
    These units accept universal RTD or resistance input signals and output proportional DC current signals. The output can also be linearized to the input sensor signal.
    $260$430
    Read more
  • Compare

    671T, 672T, 674T: Multi-Channel, Two-Wire Isolators

    • DC current input
    • Single, dual, or quad I/O loop-powered isolators
    These units receive 4-20mA process current inputs and provide isolated 4-20mA output signals. Power is derived from the input signal current. Each channel operates independently and is isolated from the others to prevent interaction between channels.
    $185$360
    Read more
  • Compare

    653T: Loop-Powered Single Input, Dual Output Signal Splitter

    • One 4 to 20mA DC input
    • Two 4 to 20mA DC outputs
    • 12-50V DC power from output loop
    • Signal splitter provides two identical outputs from one input signal
    These units receive 4-20mA process current inputs and provide isolated 4-20mA output signals. Each channel operates independently and is isolated from the others to prevent interaction between channels.
    $330
    Select options

Signal Conditioning Selection Guide Videos

Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.

Output Loop Powered Transmitters Video

DC Powered Transmitters Options Video

AC Powered Transmitters

Alarms