Click to zoom

Please sign in or register to see model options and to add products to your cart.

Product short description:
  • One 4 to 20mA DC input
  • Two 4 to 20mA DC outputs
  • 12-50V DC power from output loop
  • Signal splitter provides two identical outputs from one input signal

These units receive 4-20mA process current inputs and provide isolated 4-20mA output signals. Each channel operates independently and is isolated from the others to prevent interaction between channels.

653T: Loop-Powered Single Input, Dual Output Signal Splitter Description

These units receive 4-20mA process current inputs and provide isolated 4-20mA output signals. Each channel operates independently and is isolated from the others to prevent interaction between channels.

For easy troubleshooting, each unit has LEDs and diagnostic test points. Power LEDs help identify output open loop conditions. The precision 10-ohm sense resistor enables monitoring of the output signal without disturbing field wiring.For easy troubleshooting, each unit has LEDs and diagnostic test points.

Power LEDs help identify output open loop conditions. The precision 10-ohm sense resistor enables monitoring of the output signal without disturbing field wiring.

Learn more about the 600T Series and view all models >

653T: Loop-Powered Single Input, Dual Output Signal Splitter Features & Benefits

  • Two channels in a single unit save space and reduce costs
  • Signal splitter model (653T) provides two identical outputs from one input signal
  • Galvanic isolation eliminates ground loops, reduces noise, and blocks transient signals
  • Independent channels prevent signal interaction and offer spares for later use
  • Power LEDs provide a visual indication of operational process loops
  • Excellent accuracy and stability ensure reliable operation in noisy environments
  • -25 to 70°C (-13 to 158F) operation

Learn more about the 600T Series and view all models >

How to Re-transmit and Isolate 4-20mA Signals from Remotely-Mounted 3-Wire Gas Detection Sensors - 8400957
Defining the Problem: Signals from 3-wire remote sensors that monitor combustible and toxic gases are typically transmitted directly to the remote gas monitor or controller. However, in some cases, it’s desirable to send the signal to more than one destination. This can either be accomplished by re-transmitting the existing signal to additional locations; or by...
How to Use Acromag 600T Series Isolated Transmitters - 8401028
Application 1 Re-transmitting a signal from a two-wire loop to a second location. Solution Use either a model 651T-0600 (single channel) or 652T-0600 (dual channel) transmitter. Application 2 Splitting a signal from a two-wire loop: two outputs for different locations. Solution Use either a 653T-0600 (single input, dual output) or 652T-0600 (dual input, dual output)...

Manuals

651T, 652T, 653T User Manual (Log in to download the file)

  • Compare

    PS5R: Slim Line Power Supplies

    • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
    • Universal Input (85-264V AC / 100-370V DC)
    • Lightweight and compact size
     
    Select options This product has multiple variants. The options may be chosen on the product page

Additional information

Weight 8 oz
Dimensions 1.1 × 5 × 4.5 in
Part Number

653T-0600: one input, two output splitter

Product Series

600 Series

  • Description

    653T: Loop-Powered Single Input, Dual Output Signal Splitter Description

    These units receive 4-20mA process current inputs and provide isolated 4-20mA output signals. Each channel operates independently and is isolated from the others to prevent interaction between channels.

    For easy troubleshooting, each unit has LEDs and diagnostic test points. Power LEDs help identify output open loop conditions. The precision 10-ohm sense resistor enables monitoring of the output signal without disturbing field wiring.For easy troubleshooting, each unit has LEDs and diagnostic test points.

    Power LEDs help identify output open loop conditions. The precision 10-ohm sense resistor enables monitoring of the output signal without disturbing field wiring.

    Learn more about the 600T Series and view all models >

    653T: Loop-Powered Single Input, Dual Output Signal Splitter Features & Benefits

    • Two channels in a single unit save space and reduce costs
    • Signal splitter model (653T) provides two identical outputs from one input signal
    • Galvanic isolation eliminates ground loops, reduces noise, and blocks transient signals
    • Independent channels prevent signal interaction and offer spares for later use
    • Power LEDs provide a visual indication of operational process loops
    • Excellent accuracy and stability ensure reliable operation in noisy environments
    • -25 to 70°C (-13 to 158F) operation

    Learn more about the 600T Series and view all models >

  • Tech Papers

    How to Re-transmit and Isolate 4-20mA Signals from Remotely-Mounted 3-Wire Gas Detection Sensors - 8400957
    Defining the Problem: Signals from 3-wire remote sensors that monitor combustible and toxic gases are typically transmitted directly to the remote gas monitor or controller. However, in some cases, it’s desirable to send the signal to more than one destination. This can either be accomplished by re-transmitting the existing signal to additional locations; or by...
    How to Use Acromag 600T Series Isolated Transmitters - 8401028
    Application 1 Re-transmitting a signal from a two-wire loop to a second location. Solution Use either a model 651T-0600 (single channel) or 652T-0600 (dual channel) transmitter. Application 2 Splitting a signal from a two-wire loop: two outputs for different locations. Solution Use either a 653T-0600 (single input, dual output) or 652T-0600 (dual input, dual output)...
  • Specs & Data Sheets

    Manuals

    651T, 652T, 653T User Manual (Log in to download the file)

  • Accessories

    • Compare

      PS5R: Slim Line Power Supplies

      • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
      • Universal Input (85-264V AC / 100-370V DC)
      • Lightweight and compact size
       
      Select options This product has multiple variants. The options may be chosen on the product page
  • Additional information

    Additional information

    Weight 8 oz
    Dimensions 1.1 × 5 × 4.5 in
    Part Number

    653T-0600: one input, two output splitter

    Product Series

    600 Series