Acromag signal conditioners and network I/O is ideal for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout.

Showing all 15 results

  • Compare

    TT233: Thermocouple / milliVolt Input Two-Wire Transmitter

    • Universal TC type J, K, T, R, S, E, B, N or ±100mV input
    • 4-20mA ouput (sink/source)
    • 12-32 V DC loop/local power
    The TT233 model is a space-saving two-wire transmitter that isolates and converts a millivolt or thermocouple sensor input to a proportional 4-20mA control signal. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short AcroMaggie video highlighting the TT230 Series.
    $195
    Select options
  • Compare

    TT236: Current / milliVolt Input Two-Wire Transmitter

    • Multi-range ±20mA or ±500mV input
    • 4-20mA ouput (sink/source)
    • 12-32 V DC loop/local power
    The TT236 model is a space-saving two-wire transmitter that isolates and converts a DC current or low voltage input to a proportional 4-20mA control signal. A single unit supports both voltage and current input for extra flexibility. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short AcroMaggie video highlighting the TT230 Series.
    $195
    Select options
  • Compare

    TT239: Frequency / Pulse / PWM Input, 12-32V DC Loop Power, 2-Wire Transmitter

    • Multi-range 0Hz to 100KHz frequency input
    • Multi-range 0Hz to 3KHz PWM input
    • 4-20mA output (sink/source)
    • 12-32V DC power
    The TT239 model is a space-saving two-wire transmitter that isolates and converts a frequency, pulse, or pulse-width modulation (PWM) input to a proportional 4-20mA signal. You can select to measure either the input frequency or the duty cycle. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short AcroMaggie video highlighting the TT230 Series.
    $195
    Select options
  • Compare

    TT231: RTD / Resistance Input Two-Wire Transmitter

    • 100 ohm Pt RTD or 0-900 ohm input
    • 4-20mA output (sink/source)
    • 12-32V DC loop/local power
    • USB configuration
    The TT231 model is a space-saving two-wire transmitter that converts a 100 ohm Platinum RTD sensor input to a proportional 4-20mA signal. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short AcroMaggie video highlighting the TT230 Series.
    $195
    Select options
  • Compare

    671T, 672T, 674T: Multi-Channel, Two-Wire Isolators

    • DC current input
    • Single, dual, or quad I/O loop-powered isolators
    These units receive 4-20mA process current inputs and provide isolated 4-20mA output signals. Power is derived from the input signal current. Each channel operates independently and is isolated from the others to prevent interaction between channels.
    $185$360
    Read more
  • Compare

    SP233: Two-Wire Thermocouple / milliVolt Input Signal Splitter

    • Universal thermocouple or ±100mV input
    • 4-20mA outputs (sink/source)
    • 7-32V DC Loop/local power
    The SP233 model is a high-performance signal splitter that converts one millivolt or thermocouple sensor input into two proportional isolated 4-20mA control signals. Power is received from one or both output loop currents. Click here to watch a short video highlighting the features of the Acromag SP Series.
    $285
    Select options
  • Compare

    SP236: Two-Wire Current / milliVolt Input Signal Splitter

    • DC current and low voltage input
    • 4-20mA outputs (sink/source)
    • 7-32V DC loop power
    The SP236 model is a high-performance signal splitter that converts one DC current or millivolt input into two isolated proportional 4-20mA control signals. Power is received from one or both output loop currents. Click here to watch a short video highlighting the features of the Acromag SP Series.
    $250
    Select options
  • Compare

    SP237: Two-Wire Process Voltage Input Signal Splitter

    • Multi-range ±1V, ±5V, or ±10V input
    • 4-20mA outputs (sink/source)
    • 7-32V DC loop power
    The SP237 model is a high-performance signal splitter that converts one process-level DC voltage input into two proportional isolated 4-20mA control signals. Power is received from one or both output loop currents. Click here to watch a short video highlighting the features of the Acromag SP Series.
    $260
    Select options
  • Compare

    SP238: Two-Wire High Voltage Input Signal Splitter

    • Multi-range ±15V, ±75V, or ±150V input
    • 4-20mA outputs (sink/source)
    • 7-32V DC loop/local power
    The SP238 model is a high-performance signal splitter that converts one high-level DC voltage input into two proportional isolated 4-20mA control signals. power is received from one or both output loop currents. Click here to watch a short video highlighting the features of the Acromag SP Series.
    $275
    Select options
  • Compare

    ST132: Thermocouple/milliVolt Input Head-mount Transmitter

    • Universal thermocouple (8 types) or ±100mV input
    • 4-20mA output
    • Loop-powered, 7-32V DC
    The ST132 is a low-cost two-wire transmitter that converts a millivolt or thermocouple sensor input to a proportional 4-20mA control signal. Power is received from the output loop current. The transmitter performs signal linearization, cold-junction compensation, and lead-break detection functions.
    $140
    Select options
  • Compare

    TT234: Potentiometer / Thermistor Input, Two-Wire Transmitter

    • Potentometer / slidewire, thermister input
    • 4 to 20mA output (sink / source)
    • 12-32V DC loop / local power
    • USB configuration
    The TT234 model is a space-saving two-wire transmitter that isolates and converts a resistive sensor input to a proportional 4-20mA signal. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short AcroMaggie video highlighting the TT230 Series.
    $195
    Select options
  • Compare

    TT235: Isolated RTD Input, Loop Power, 2-Wire Transmitter

    • Selectable RTD or linear resistance input type or 0-500 ohm input
    • 4-20mA output (sink/source)
    • 12-32V DC loop/local power
    • USB configuration
    The TT235 model is a space-saving two-wire transmitter that isolates and converts an RTD sensor input to a proportional 4-20mA signal. Power is received from the output loop current or a DC supply when using a three-wire connection. Click here to watch a short AcroMaggie video highlighting the TT230 Series.
    $195
    Select options
  • Compare

    TT237: Voltage Input, Loop-Power, 2-Wire Transmitter

    • Multi-range ±1V, ±5V or ±10V input
    • 4-20mA output (sink/source)
    • 12-32 V loop power
    The TT237 model is a space-saving two-wire transmitter that isolates and converts a process level DC voltage input to a proportional 4-20mA control signal. A single unit supports multiple voltage input ranges for extra flexibility. Power is received from the output loop current or a local DC supply when using a three-wire connection. Click here to watch a short AcroMaggie video highlighting the TT230 Series.
    $195
    Select options
  • Compare

    TT238: High Voltage Input, Loop-Powered, 2-Wire Transmitter

    • Multi-range ±15V, ±75V or ±150V DC input
    • 4-20mA ouput (sink/source)
    • 12-32 V DC loop power
    The TT238 model is a space-saving two-wire transmitter that isolates and converts a high level DC voltage input to a proportional 4-20mA control signal. A single unit supports multiple voltage input ranges for extra flexibility. Power is received from the output loop current or a local DC supply when using a three-wire connection. Click here to watch a short AcroMaggie video highlighting the TT230 Series.
    $195
    Select options
  • Compare

    250T-RB, 350T-RB, 450T-RB Loop, DC, or AC-Power Transmitter

    • Platinum RTD or Copper RTD (resistance temperature sensor) Input
    • DC Voltage/Current Output
    $460$535
    Read more

Signal Conditioning Selection Guide Videos

Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.

Output Loop Powered Transmitters Video

DC Powered Transmitters Options Video

AC Powered Transmitters

Alarms