ST133: Isolated Transmitter; Thermocouple/mV Input
Please sign in or register to see model options and to add products to your cart.
Product short description:
- TC type J, K, T, R, S, E, B, and N or ±100mV input
- 1500V isolation
- 4 to 20mA DC output
- USB-configured
The ST133 is a low-cost two-wire transmitter that isolates and converts a millivolt or thermocouple sensor input to a proportional 4-20mA control signal. Power is received from the output loop current. The transmitter performs signal linearization, cold-junction compensation, and lead-break detection functions.
- Description
- Features & Benefits
- Tech Papers
- Specs & Data Sheets
- Software
- Accessories
- Additional information
ST133: Isolated Transmitter; Thermocouple/mV Input Head-Mount Transmitter Description
The ST133 is a low-cost two-wire transmitter that isolates and converts a millivolt or thermocouple sensor input to a proportional 4-20mA control signal. Power is received from the output loop current. The transmitter performs signal linearization, cold-junction compensation, and lead-break detection functions.
High-voltage isolation separates the input from the output circuit. Isolation protects from surges, reduces noise, and eliminates ground loop errors. Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software.
Advanced signal processing capabilities, variable range input, and convenient USB programming make this instrument a very versatile temperature measurement device. These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.
Performance Specifications
USB Interface
USB Connector: USB Mini-B type socket, 5-pin.
USB Data Rate: 12Mbps. USB v1.1 and 2.0 compatible.
USB Transient Protection: Transient voltage suppression on power and data lines.
USB Cable Length: 5.0 meters maximum.
Driver: Not required. Uses built-in Human Interface Device (HID) USB drivers of the Windows operating system.
Input
Default Configuration/Calibration
Input: TC J, -210 to 760°C, upscale fault, high filter.
Output: 4 to 20mA.
Input Ranges and Accuracy
Input Range Accuracy
TC J -210 to 760°C (-346 to 1400°F) ±0.5°C
TC K -200 to 1372°C (-328 to 2502°F) ±0.5°C
TC T -260 to 400°C (-436 to 752°F) ±0.5°C
TC R -50 to 1768°C (-58 to 3214°F) ±1.0°C
TC S -50 to 1768°C (-58 to 3214°F) ±1.0°C
TC E -200 to 1000°C (-328 to 1832°F) ±0.5°C
TC B 260 to 1820°C (500 to 3308°F) ±1.0°C
TC N -230 to 1300°C (-382 to 2372°F) ±1.0°C
mV -100 to 100mV ±0.1mV
Error includes the effects of repeatability, terminal point conformity, and linearization at 25°C operating ambient temperature.
Thermocouple Reference (Cold Junction Compensation)
±0.1°C typical, ±0.3°C maximum at 25°C.
Ambient Temperature Effect: Better than ±75ppm/°C (±0.0075%/°C).
Zero Scaling Adjust: 0 to 95% of range, typical.
Full Scale Adjust: 5 to 100% of full scale range, typical.
Lead Break (Sensor Burnout) Detection: Configurable for either upscale (24mA) or downscale (3.3mA) operation.
Thermocouple Input Bias Current: ±250nA typical (TC break).
Input Over-Voltage Protection: Bipolar Transient Voltage Suppressers (TVS), 5.6V clamp level typical.
Resolution: Millivolt input: 0.0025% (1 part in 40,000). Thermocouple input: 0.1°C.
Input Filter: Normal mode filtering, plus selectable digital filtering settings (none, low, medium, high) optimized and fixed per input range within the A/D converter.
Noise Rejection (Normal Mode): 75dB @ 60Hz, typical with 100 ohm input unbalance.
Output
Output Range: 4 to 20mA DC.
Output Compliance
Rload = (Vsupply – 12V) / 0.024A.
Rload = 0 to 500 ohms @ 24V DC.
Output Response Time (for step input change)
Time to reach 98% of final output value (typical)
No filtering 90 to 125ms
Low filter 240 to 420ms
Medium filter 550 to 1020ms
High filter 900 to 1500ms
Environmental
Operating temperature: -40 to 80°C (-40° to 176°F).
Storage temperature: -40 to 85°C (-40 to 185°F).
Relative humidity: 5 to 95% non-condensing.
Power Requirement: 12-32V DC SELV (Safety Extra Low Voltage), 24mA max.
Isolation: 1500V AC peak. 250V AC (354V DC) continuous isolation between input and output circuits.
Shock and Vibration Immunity
Vibration: 5g, per IEC 60068-2-64.
Shock: 50g, per IEC 60068-2-27.
Electromagnetic Compatibility (EMC) Compliance
Radiated Emissions: BS EN 61000-6-4, CISPR 16.
RFI: BS EN 61000-6-2, IEC 61000-4-3.
Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6.
ESD: BS EN 61000-6-2, IEC 61000-4-2.
EFT: BS EN 61000-6-2, IEC 61000-4-4.
Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5.
Approvals
CE compliant. UL/cUL listings. ATEX Certified.
Designed for Class I; Division 2; Groups ABCD; Zone 2.
Physical
General
General purpose enclosure with potted circuit designed for mounting in DIN Form B connection heads.
Case Material: Self-extinguishing polycarbonate ABS plastic, UL94 V-0 rated base material. USB dust cap material is Santoprene, 251-70W232.
I/O Connectors: Barrier strip type, captive screw terminals. Wire range: AWG #14-28 solid or stranded.
Shipping Weight: 0.5 pounds (0.22 Kg) packed.
- Easy setup and digital calibration via USB with Windows configuration software
- Flexible thermocouple or millivolt input ranges (TC Type J, K, T, R, S, E, B, N or ±100mV)
- 1500V input isolation
- 24-bit A/D micro-controller
- High accuracy, linearity, stability, and reliability
- Low temperature drift (<75ppm/°C)
- Fast response time (as low as 90ms)
- User selectable filtering (none, low, med., high)
- Supports reverse-acting (inverse) output
- Selectable upscale or downscale operation for sensor errors and lead-break detection
- Non-polarized output/power connection
- Mounts in DIN Form B sensor heads
- Shock (50g) and vibration (5g) resistant
- Optional DIN rail adapter
- Wide ambient operation (-40 to 80°C)
- Hardened for harsh environments
- CE compliant. UL/cUL Class 1 Div 2 Zone 2 approvals. Ex II 3 G Ex nA IIC T4 Gc -40°C < Ta < +80°C certified.
-
ST130 Mounting Accessories
- Simplifies mounting of ST130 Series transmitters
- Ideal for mounting in the field or in a control room
-
ST13C-SIP
- Configuration software
- USB isolator
- Two USB cables
- One kit recommended per customer
-
An Isolator: USB Isolator
- USB-powered, USB 2.0 and 1.1 compatible
- 1500V AC / 2100V DC isolation
- No drivers required
Additional information
Weight | 8 oz |
---|---|
Dimensions | 4 × 4 × 2 in |
Part Number | ST133-1610: CE compliant, click to see all approvals/certifications below |
Configuration | Factory Calibration, USB Configuration, Windows Software Configuration |
Product Series | ST130 Series |
Power Type | Loop Power |
-
Description
ST133: Isolated Transmitter; Thermocouple/mV Input Head-Mount Transmitter Description
The ST133 is a low-cost two-wire transmitter that isolates and converts a millivolt or thermocouple sensor input to a proportional 4-20mA control signal. Power is received from the output loop current. The transmitter performs signal linearization, cold-junction compensation, and lead-break detection functions.
High-voltage isolation separates the input from the output circuit. Isolation protects from surges, reduces noise, and eliminates ground loop errors. Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software.
Advanced signal processing capabilities, variable range input, and convenient USB programming make this instrument a very versatile temperature measurement device. These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.
Performance Specifications
USB Interface
USB Connector: USB Mini-B type socket, 5-pin.
USB Data Rate: 12Mbps. USB v1.1 and 2.0 compatible.
USB Transient Protection: Transient voltage suppression on power and data lines.
USB Cable Length: 5.0 meters maximum.
Driver: Not required. Uses built-in Human Interface Device (HID) USB drivers of the Windows operating system.
Input
Default Configuration/Calibration
Input: TC J, -210 to 760°C, upscale fault, high filter.Output: 4 to 20mA.
Input Ranges and Accuracy
Input Range Accuracy
TC J -210 to 760°C (-346 to 1400°F) ±0.5°C
TC K -200 to 1372°C (-328 to 2502°F) ±0.5°C
TC T -260 to 400°C (-436 to 752°F) ±0.5°C
TC R -50 to 1768°C (-58 to 3214°F) ±1.0°C
TC S -50 to 1768°C (-58 to 3214°F) ±1.0°C
TC E -200 to 1000°C (-328 to 1832°F) ±0.5°C
TC B 260 to 1820°C (500 to 3308°F) ±1.0°C
TC N -230 to 1300°C (-382 to 2372°F) ±1.0°C
mV -100 to 100mV ±0.1mVError includes the effects of repeatability, terminal point conformity, and linearization at 25°C operating ambient temperature.
Thermocouple Reference (Cold Junction Compensation)
±0.1°C typical, ±0.3°C maximum at 25°C.Ambient Temperature Effect: Better than ±75ppm/°C (±0.0075%/°C).
Zero Scaling Adjust: 0 to 95% of range, typical.
Full Scale Adjust: 5 to 100% of full scale range, typical.
Lead Break (Sensor Burnout) Detection: Configurable for either upscale (24mA) or downscale (3.3mA) operation.
Thermocouple Input Bias Current: ±250nA typical (TC break).
Input Over-Voltage Protection: Bipolar Transient Voltage Suppressers (TVS), 5.6V clamp level typical.
Resolution: Millivolt input: 0.0025% (1 part in 40,000). Thermocouple input: 0.1°C.
Input Filter: Normal mode filtering, plus selectable digital filtering settings (none, low, medium, high) optimized and fixed per input range within the A/D converter.
Noise Rejection (Normal Mode): 75dB @ 60Hz, typical with 100 ohm input unbalance.
Output
Output Range: 4 to 20mA DC.
Output Compliance
Rload = (Vsupply – 12V) / 0.024A.
Rload = 0 to 500 ohms @ 24V DC.Output Response Time (for step input change)
Time to reach 98% of final output value (typical)
No filtering 90 to 125ms
Low filter 240 to 420ms
Medium filter 550 to 1020ms
High filter 900 to 1500msEnvironmental
Operating temperature: -40 to 80°C (-40° to 176°F).
Storage temperature: -40 to 85°C (-40 to 185°F).
Relative humidity: 5 to 95% non-condensing.
Power Requirement: 12-32V DC SELV (Safety Extra Low Voltage), 24mA max.
Isolation: 1500V AC peak. 250V AC (354V DC) continuous isolation between input and output circuits.
Shock and Vibration Immunity
Vibration: 5g, per IEC 60068-2-64.
Shock: 50g, per IEC 60068-2-27.Electromagnetic Compatibility (EMC) Compliance
Radiated Emissions: BS EN 61000-6-4, CISPR 16.RFI: BS EN 61000-6-2, IEC 61000-4-3.
Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6.
ESD: BS EN 61000-6-2, IEC 61000-4-2.
EFT: BS EN 61000-6-2, IEC 61000-4-4.
Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5.
Approvals
CE compliant. UL/cUL listings. ATEX Certified.
Designed for Class I; Division 2; Groups ABCD; Zone 2.Physical
General
General purpose enclosure with potted circuit designed for mounting in DIN Form B connection heads.Case Material: Self-extinguishing polycarbonate ABS plastic, UL94 V-0 rated base material. USB dust cap material is Santoprene, 251-70W232.
I/O Connectors: Barrier strip type, captive screw terminals. Wire range: AWG #14-28 solid or stranded.
Shipping Weight: 0.5 pounds (0.22 Kg) packed.
-
Features & Benefits
- Easy setup and digital calibration via USB with Windows configuration software
- Flexible thermocouple or millivolt input ranges (TC Type J, K, T, R, S, E, B, N or ±100mV)
- 1500V input isolation
- 24-bit A/D micro-controller
- High accuracy, linearity, stability, and reliability
- Low temperature drift (<75ppm/°C)
- Fast response time (as low as 90ms)
- User selectable filtering (none, low, med., high)
- Supports reverse-acting (inverse) output
- Selectable upscale or downscale operation for sensor errors and lead-break detection
- Non-polarized output/power connection
- Mounts in DIN Form B sensor heads
- Shock (50g) and vibration (5g) resistant
- Optional DIN rail adapter
- Wide ambient operation (-40 to 80°C)
- Hardened for harsh environments
- CE compliant. UL/cUL Class 1 Div 2 Zone 2 approvals. Ex II 3 G Ex nA IIC T4 Gc -40°C < Ta < +80°C certified.
-
Tech Papers
Why Do I Need Electrical Isolation? - 8500988 (Log in to view the file)Why do we need signal isolation? Acromag is in the business of signal conditioning. We manufacture circuits that amplify, isolate, filter, and convert one signal form to another. Most of these circuits also provide electrical isolation. However, added isolation has a cost. Thus, sometimes customers either question their need for isolation or fail to recognize...How to use Thermocouple Transmitters to Monitor Temperatures in Paint Systems - 8400818This document illustrates using Acromag’s TT330 Series to monitor high temperatures in an automotive paint curing oven and transmit to the existing PLC 4-20mA input card/software setup. Defining the Problem The area around an auto manufacturer’s paint curing ovens is at elevated temperatures affecting the performance of locally installed instrumentation. Placing signal conditioners rated for...How to Minimize Thermocouple to Transmitter Measurement Errors - 8500926 (Log in to view the file)Preventing Temperature Measurement Error in Thermocouple to Transmitter Connections The nature of thermocouple (TC) circuits is that they’re prone to produce error when mating them to a measurement device; unless you have some insight into how these TCs and their components work. This paper reviews thermocouple behavior and outlines common problems encountered when connecting them...How to use Thermocouples for Temperature Measurement - 8500911 (Log in to view the file)Criteria for Temperature Selection of T/C and RTD Sensor Types This is part two of a comprehensive three-part series that provides information for choosing an industrial temperature sensor from Thermocouple (T/C) and Resistance Temperature Detector (RTD) sensor types. The Basics of Temperature Measurement Using Thermocouples You are probably somewhat familiar with the thermocouple, or... -
Specs & Data Sheets
-
Software
ST132 and ST133 Configuration Software (Log in to download the file) -
Accessories
-
ST130 Mounting Accessories
- Simplifies mounting of ST130 Series transmitters
- Ideal for mounting in the field or in a control room
-
ST13C-SIP
- Configuration software
- USB isolator
- Two USB cables
- One kit recommended per customer
-
An Isolator: USB Isolator
- USB-powered, USB 2.0 and 1.1 compatible
- 1500V AC / 2100V DC isolation
- No drivers required
-
-
Additional information
Additional information
Weight 8 oz Dimensions 4 × 4 × 2 in Part Number ST133-1610: CE compliant, click to see all approvals/certifications below
Configuration Factory Calibration, USB Configuration, Windows Software Configuration
Product Series ST130 Series
Power Type Loop Power
Please login to submit this form.