Acromag remote I/O modules feature signal conditioners and network I/O  for a broad range of monitoring and control operations where controllers communicate with instrumentation on the plant floor or in the field. Signal Conditioners include signal transmitters, signal isolators, 4-20mA signal splitters, limit alarms and computation modules. These signal conditioners input voltage, current, thermocouple, RTD, frequency, thermistor, load cell, potentiometer, and discrete sensors. These signal conditioners output DC voltage and current, relay, frequency, pulse width modulation and display/readout. Ethernet remote I/O modules communicate via Ethernet/IP, Modbus TCP/IP, Modbus UDP/IP, and Profinet.

Showing all 11 results

  • Compare

    VPM3000 Series: Universal Transmitter / Alarm with Display

    • Big, bright display
    • 4-20mA, ±10V, thermocouple, or RTD input
    • 4-20mA, Modbus serial, or alarm relay output options
    Acromag VPM3000 Vertuâ„¢ digital panel meters are among the most versatile on the market and able to operate as a transmitter and/or alarm to satisfy a wide variety of process and temperature applications. Learn more about the VPM3000 by watching this short video.
    Select options
  • Compare

    901MB, 902MB, 903MB: Multi-Channel Modbus-RTU Discrete I/O Modules

    • Active-Low Inputs, Sinking Outputs (Low-Side Switching)
    • 12 input and/or 12 output channels
    • 0 to 35V DC I/O range
    • 10 to 36V DC, 24V AC power
    • Modbus-RTU high-speed RS-485
    These modules provide twelve discrete input and/or output channels. Isolation separates the I/O, power, and network circuits. Network communication adheres to the industry-standard RS-485 Modbus-RTU protocol.    
    Select options
  • Compare

    904MB, 905MB, 906MB: Multi-Channel Discrete I/O Modules

    • Active-High Inputs, Sourcing Outputs (High-Side Switching)
    • 12 input and/or 12 output channels
    • 0 to 35V DC I/O range
    • 10 to 36V DC, 24V AC power
    • Modbus-RTU high-speed RS-485
    These modules provide twelve discrete input and/or output channels. Isolation separates the I/O, power, and network circuits. Network communication adheres to the industry-standard RS-485 Modbus RTU protocol.
    Select options
  • Compare

    913MB, 914MB: DC Current/Voltage Modbus-RTU Input Module with Limit Alarms

    • 4 input channels
    • 0 to 20mA DC (0 to 20A AC with AC sensor) or ±10V DC input range
    • 4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
    • 10 to 36V DC, 24V AC power
    • Modbus RTU high-speed RS-485
    This signal conditioner is a four-channel analog input module with four discrete outputs. It provides isolation between input, output, power, and network circuits.
    Select options
  • Compare

    917MB, 918MB: DC Current/Voltage Modbus-RTU Output Modules with Discrete Outputs

    • 4 analog output channels
    • 0 to 20mA or 0 to 10V DC output range
    • 4 discrete output channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
    • 10 to 36V DC, 24V AC power
    • Modbus RTU high-speed RS-485
    These modules drive four analog output channels and also feature four discrete outputs for on/off control. Isolation separates the output, power, and network circuits. Network communication adheres to the industry-standard RS-485 Modbus RTU protocol.
    Select options
  • Compare

    924MB: Thermocouple/milliVolt Modbus-RTU Input Module with Limit Alarms

    • 4 input channels, thermocouple (types J, K, T, R, S, E, B, N) or millivolt (±100mV DC) input
    • 4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC)
    • 10 to 36V DC, 24V AC power
    • Modbus-RTU high-speed RS-485
    This signal conditioner is a four-channel analog input module with four discrete outputs. It filters and linearizes thermocouple inputs while providing isolation between input, output, power, and network circuits. Cold junction compensation and upscale/downscale sensor break detection are standard.  
    Select options
  • Compare

    932MB, 934MB: RTD/Resistance Modbus-RTU Input Modules with Limit Alarms or Discrete Outputs

    • 2 or 4 input channels, RTD (100 ohm Pt, 120 ohm Ni, 10 ohm Cu) or resistance (0 to 500 ohms) input
    • Solid-state relays discrete output, Form A, SPST-NO
    • 10 to 36V DC, 24V AC power
    • Modbus-RTU high-speed RS-485
    This signal conditioner is a dual or quad-channel analog input module with one discrete/relay output per input channel and a Modbus interface. It filters and linearizes RTD or resistance inputs while providing isolation between input, output, power, and network circuits.
    Select options
  • Compare

    942MB: Frequency/Pulse Counter Modbus-RTU Input Modules with Periodic or Pulse Waveform Input

    • 2 input channels, 0 to 50KHz in 3 selectable ranges: Amplitudes up to 140V AC peak, Amplitudes up to 200V peak, Pulse counter range of 0 to 65535
    • Solid-state discrete output relays (1A DC loads), 0 to 48V DC
    • 10 to 36V DC, 24V AC power
    • Modbus-RTU high-speed RS-485
    This signal conditioner is a two-channel analog input module with discrete outputs and Modbus communication. It conditions periodic or pulse waveform inputs and provides solid-state relays for limit alarms or ON/OFF control.
    Select options
  • Compare

    AMTN, AMTX: ActiveX / .NET Controls for Modbus I/O

    • Modbus/TCP or Modbus/RTU
    • These ActiveX / .NET software controls provide a fast, easy way to communicate with any Modbus slave devices connected to your PC.
    • Get your Visual Basic, Visual C, .NET, Excel, or other compatible applications talking Modbus protocol within minutes.
    Select options
  • Compare

    APM765 Series: Universal Input with Alarm Panel Meter

    • Universal input
    • Isolated 4-20mA and Modbus output options
    • Push-button or PC programmable,
    • 85-265V AC or 90-265V DC power, optional 12-24V AC or 12-36V DC power
    The APM765 displays data collected from process current, DC voltage and temperature inputs. Several output options convert the display into a transmitter with proportional 4-20mA output or a serial communication interface.
    Select options
  • Compare

    4683 Series: RS485-to-RS485 Network Repeater

    • Designed for use with Johnson Controls N2 or BACnet MS/TP bus
    • 115V AC ±10%, 50/60 Hz, 0.05A or 230V AC ±10%, 50/60 Hz, 0.03A or 24V AC ±10%, 50/60 Hz, 0.18A typical power
    • Operating temperature: -25 to 70° C (-13 to 158° F)
    4683-TTM-1F: 115V AC Power 4683-TTM-2F: 230V AC Power 4683-TTM-3F: 24V AC Power
    Select options

Signal Conditioning Selection Guide Videos

Welcome to our Signal Conditioning Selection Guide Videos. As a business with many helpful products to offer, we know it can be difficult to find which one you need. This quick selection guide should help point you in the right direction. Choose which video corresponds to your power needs, and the guide will show you which Acromag modules will work with your input.

Learn more in this whitepaper: What is Ethernet/IP?

Output Loop Powered Transmitters Video

DC Powered Transmitters Options Video

AC Powered Transmitters

Alarms