Click to zoom
$195
Clear
Product short description:
  • Multi-range 0Hz to 100KHz frequency input
  • Multi-range 0Hz to 3KHz PWM input
  • 4-20mA output (sink/source)
  • 12-32V DC power

The TT239 model is a space-saving two-wire transmitter that isolates and converts a frequency, pulse, or pulse-width modulation (PWM) input to a proportional 4-20mA signal. You can select to measure either the input frequency or the duty cycle. Power is received from the output loop current or a DC supply when using a three-wire connection.

Click here to watch a short AcroMaggie video highlighting the TT230 Series.

 

[DISPLAY_ULTIMATE_PLUS]

TT239: Frequency / Pulse / PWM Input, 12-32V DC Loop Power, 2-Wire Transmitter Description

The TT239 model is a space-saving two-wire transmitter that isolates and converts a frequency, pulse, or pulse-width modulation (PWM) input to a proportional 4-20mA signal. You can select to measure either the input frequency or the duty cycle. Power is received from the output loop current or a DC supply when using a three-wire connection.

High-voltage isolation separates the input from the output circuit. Isolation protects from surges, reduces noise, and eliminates ground loop errors.

Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software.

Advanced signal processing capabilities, variable range input, and convenient USB programming make this instrument a very versatile frequency measurement device. These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.

Performance Specifications

IMPORTANT: To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends the use of their USB-ISOLATOR when configuring a TT230 Series transmitter.

USB Interface

USB Connector: USB Mini-B type socket, 5-pin
USB Data Rate: 12Mbps. USB v1.1 and 2.0 compatible
USB Transient Protection: Transient voltage suppression on power and data lines
USB Cable Length: 5.0 meters maximum
Driver: Not required. Uses built-in Human Interface Device (HID) USB drivers of the Windows operating system

Input

Default Configuration/Calibration:
±5.0V Square Wave
Input Threshold = Bipolar 0.0V
Hysteresis ±25mV
Measurement = Frequency
Pull Up/Down = Disabled
Excitation = Enabled
0Hz Cutoff = 0.5Hz
Sample Average = 1
Output Range = 4-20mA
I/O Scaling = 0Hz to 10KHz, Normal Acting
Output Update = 100ms

Frequency Input: Configurable for any range from 0Hz to 100KHz. Accepts unipolar (non-zero crossing) or bipolar (zero crossing) input signals. 0.5Hz minimum span. 10μs minimum pulse width.

Input Ranges
Frequency Input          Output Update      Input Resolution     Typical Accuracy
0 to 100Hz                                 Any rate               1 part in 60000                  ±0.05Hz
0 to 1KHz                                   Any rate               1 part in 6000                     ±0.5Hz
0 to 5KHz                                   Any rate               1 part in 1200                     ±1Hz
0 to 10KHz                                   10ms                  1 part in 60000                   ±200Hz
0 to 10KHz                                 100ms                  1 part in 600000                ±20Hz
0 to 10KHz                               1000ms                  1 part in 6000000             ±2Hz
0 to 100KHz                                 10ms                  1 part in 60000                   ±400Hz
0 to 100KHz                               100ms                  1 part in 600000                ±40Hz
0 to 100KHz                             1000ms                 1 part in 6000000              ±4Hz

PWM Input                            Cycle                            Input                             Typical
Carrier Freq                         Range                        Resolution                   Accuracy
0 to 100Hz                                1 to 99%               1 part in 60000                  ±0.02%
0 to 1KHz                                10 to 90%              1 part in 6000                     ±0.2%
0 to 3KHz                               20 to 80%               1 part in 1200                     ±2.0%

Input Scaling Adjust:
Zero: Adjustable over 0 to 99% of full-scale input
Full scale: Adjustable over 0.5Hz to 100KHz
Cut-off frequency: Adjustable over 0.01Hz to 100KHz
Input Pull-up/Pull-down (internal, software-select):
Configurable 12.4KΩ pull-up to +4V and 1KΩ pulldown to –FRTN, or disabled. 15V DC maximum input
4V pull-up with ±28mV hysteresis or 3V when ±84mV
Unipolar Signal Configuration:
Amplitude: 0 to 3V DC min., 0 to 170V DC max
Thresholds: Configurable for 1.6V DC (±25mV hysteresis) or 5V DC (±83mV hysteresis), typical
Bipolar Signal Configuration:
Amplitude: ±50 to ±200mV min. (depending on range and hysteresis), 120Vrms max. (±170V DC)
Thresholds: 0mV nominal (±25 or ±83mV hysteresis)

Output

Output Range: 4 to 20mA DC, wired as sink or source
Under-range capability 3.6mA
Over-range capability 24mA
Output Compliance:
Rload = (Vsupply – 12V) / 0.020A
Rload = 0 to 600 ohms @ 24V DC
Output DAC Resolution: 16-bit D/A converter
Output Update: Software configurable from 10ms to 5000ms. Determines the rate at which the output signal is updated, unless optionally overridden.
Output Settling Time: 1ms, 0% to 98% for a step-change in input, typical
Output Accuracy: Better than ±0.05% of span, typical (±0.1% max) for for nominal input spans. Includes the effects of repeatability, terminal point conformity, and linearization, but does not include sensor error.
Ambient Temperature Effect: Better than ±0.0020% per °C of input span or ±20ppm/°C, typical. Includes the combined effects of zero and span drift over temperature

Environmental

Operating temperature: -40 to 80°C (-40° to 176°F)
Storage temperature: -40 to 85°C (-40 to 185°F)
Relative humidity: 5 to 95% non-condensing
Power requirement: 12-32V DC SELV (Safety Extra Low Voltage), 24mA maximum
Isolation: 1500V AC peak. 250V AC (354V DC) continuous isolation between input and output circuits
Shock and Vibration Immunity:
Vibration: 4g, per IEC 60068-2-64
Shock: 25g, per IEC 60068-2-27
Electromagnetic Compatibility (EMC) Compliance:
Radiated Emissions: BS EN 61000-6-4, CISPR 16
RFI: BS EN 61000-6-2, IEC 61000-4-3
Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6
ESD: BS EN 61000-6-2, IEC 61000-4-2
EFT: BS EN 61000-6-2, IEC 61000-4-4
Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5
Approvals:
CE compliant. Designed for UL/cUL Class I Division 2 Groups ABCD, ATEX / IECEx Zone 2. II 3 G Ex nA IIC T4 Gc -40°C < Ta < +80°C

Physical

General: General-purpose enclosure designed for mounting on 35mm “T-type” DIN rail
Case Material: Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General-purpose NEMA Type 1 enclosure
I/O Connectors: Removable plug-in terminal blocks rated for 12A/250V; AWG #26-12, stranded or solid copper wire
Dimensions: 12.5 x 114.5 x 99.0 mm (0.5 x 4.51 x 3.90 inches)
Shipping Weight: 0.22 kg (0.5 pounds) packed

 

  • Easy setup and digital calibration via USB with Windows configuration software
  • Measures frequency or duty cycle and interfaces many input types up to 100KHz
  • Accepts input amplitudes up to 120Vrms (±170V DC, unipolar or bipolar)
  • Adjustable 0Hz cut-off, sample averaging, debounce, and output update time
  • Software configurable pull-up/down resistors ( 4V DC input pull-up for sensors/tranducers)
  • 1500V isolation between input/output circuits
  • Space-saving 12.5mm (0.5 inch) unit with pluggable terminals for convenient wiring
  • Fast response time and high accuracy
  • Supports normal or reverse-acting output
  • Supports sink or source output wiring
  • NAMUR-compliant output loop current
  • Shock (25g) and vibration (4g) resistant
  • Wide ambient operation (-40 to 80°C)
  • CE compliant. UL/cUL Class I Div 2, ATEX / IECEx Zone 2 approvals

 

Specifications

Manuals

TT239 User Manual (Log in to download the file)

TT230 Series Windows Configuration Software (Log in to download the file)
Agility™ Config Tool (Wireless) (Log in to download the file)
  • Compare

    Agility™ Config Tool (Wireless)

    • Wireless Agility™ Config Tool mobile application
    • For Acromag microBlox I/O Modules and Limit Alarms
    • Download available on Google Play and iTunes for free
    • Download Windows configuration software from the software tab below
    Read more
  • Compare

    PS5R: Slim Line Power Supplies

    • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
    • Universal Input (85-264V AC / 100-370V DC)
    • Lightweight and compact size
    $95$245
    Select options
  • Compare

    TTC-SIP: Software

    • Software Interface Package for Acromag DT, ST, TT Series Transmitters and SP, uBSP Series Signal Splitters.
    • Includes configuration sofware CD-ROM (5040-xxx), isolator (USB-ISOLATOR) and two USB cable (4001-112, 4001-113) (Recommend one kit per customer.)
    • Easy setup and digital calibration via USB with Windows configuration software.
    • Download the configuration software only - from the Software Tab
    $170
    Select options
  • Compare

    USB Isolator

    • USB-powered, USB 2.0 and 1.1 compatible
    • 1500V AC / 2100V DC isolation
    • No drivers required
    This compact, industrial-grade isolator provides a high-voltage isolation barrier between a computer and a connected USB device.
    $110
    Select options

Additional information

Weight 8 oz
Dimensions 4.51 × 0.5 × 3.9 in
Part Number

TT239-0600: Two-wire, isolated freq

Configuration

Agility Mobile App, Factory Calibration, USB Configuration, Windows Software Configuration

Product Series

TT230 Series

Power

Loop Power

  • Description

    TT239: Frequency / Pulse / PWM Input, 12-32V DC Loop Power, 2-Wire Transmitter Description

    The TT239 model is a space-saving two-wire transmitter that isolates and converts a frequency, pulse, or pulse-width modulation (PWM) input to a proportional 4-20mA signal. You can select to measure either the input frequency or the duty cycle. Power is received from the output loop current or a DC supply when using a three-wire connection.

    High-voltage isolation separates the input from the output circuit. Isolation protects from surges, reduces noise, and eliminates ground loop errors.

    Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software.

    Advanced signal processing capabilities, variable range input, and convenient USB programming make this instrument a very versatile frequency measurement device. These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.

    Performance Specifications

    IMPORTANT: To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends the use of their USB-ISOLATOR when configuring a TT230 Series transmitter.

    USB Interface

    USB Connector: USB Mini-B type socket, 5-pin
    USB Data Rate: 12Mbps. USB v1.1 and 2.0 compatible
    USB Transient Protection: Transient voltage suppression on power and data lines
    USB Cable Length: 5.0 meters maximum
    Driver: Not required. Uses built-in Human Interface Device (HID) USB drivers of the Windows operating system

    Input

    Default Configuration/Calibration:
    ±5.0V Square Wave
    Input Threshold = Bipolar 0.0V
    Hysteresis ±25mV
    Measurement = Frequency
    Pull Up/Down = Disabled
    Excitation = Enabled
    0Hz Cutoff = 0.5Hz
    Sample Average = 1
    Output Range = 4-20mA
    I/O Scaling = 0Hz to 10KHz, Normal Acting
    Output Update = 100ms

    Frequency Input: Configurable for any range from 0Hz to 100KHz. Accepts unipolar (non-zero crossing) or bipolar (zero crossing) input signals. 0.5Hz minimum span. 10μs minimum pulse width.

    Input Ranges
    Frequency Input          Output Update      Input Resolution     Typical Accuracy
    0 to 100Hz                                 Any rate               1 part in 60000                  ±0.05Hz
    0 to 1KHz                                   Any rate               1 part in 6000                     ±0.5Hz
    0 to 5KHz                                   Any rate               1 part in 1200                     ±1Hz
    0 to 10KHz                                   10ms                  1 part in 60000                   ±200Hz
    0 to 10KHz                                 100ms                  1 part in 600000                ±20Hz
    0 to 10KHz                               1000ms                  1 part in 6000000             ±2Hz
    0 to 100KHz                                 10ms                  1 part in 60000                   ±400Hz
    0 to 100KHz                               100ms                  1 part in 600000                ±40Hz
    0 to 100KHz                             1000ms                 1 part in 6000000              ±4Hz

    PWM Input                            Cycle                            Input                             Typical
    Carrier Freq                         Range                        Resolution                   Accuracy
    0 to 100Hz                                1 to 99%               1 part in 60000                  ±0.02%
    0 to 1KHz                                10 to 90%              1 part in 6000                     ±0.2%
    0 to 3KHz                               20 to 80%               1 part in 1200                     ±2.0%

    Input Scaling Adjust:
    Zero: Adjustable over 0 to 99% of full-scale input
    Full scale: Adjustable over 0.5Hz to 100KHz
    Cut-off frequency: Adjustable over 0.01Hz to 100KHz
    Input Pull-up/Pull-down (internal, software-select):
    Configurable 12.4KΩ pull-up to +4V and 1KΩ pulldown to –FRTN, or disabled. 15V DC maximum input
    4V pull-up with ±28mV hysteresis or 3V when ±84mV
    Unipolar Signal Configuration:
    Amplitude: 0 to 3V DC min., 0 to 170V DC max
    Thresholds: Configurable for 1.6V DC (±25mV hysteresis) or 5V DC (±83mV hysteresis), typical
    Bipolar Signal Configuration:
    Amplitude: ±50 to ±200mV min. (depending on range and hysteresis), 120Vrms max. (±170V DC)
    Thresholds: 0mV nominal (±25 or ±83mV hysteresis)

    Output

    Output Range: 4 to 20mA DC, wired as sink or source
    Under-range capability 3.6mA
    Over-range capability 24mA
    Output Compliance:
    Rload = (Vsupply – 12V) / 0.020A
    Rload = 0 to 600 ohms @ 24V DC
    Output DAC Resolution: 16-bit D/A converter
    Output Update: Software configurable from 10ms to 5000ms. Determines the rate at which the output signal is updated, unless optionally overridden.
    Output Settling Time: 1ms, 0% to 98% for a step-change in input, typical
    Output Accuracy: Better than ±0.05% of span, typical (±0.1% max) for for nominal input spans. Includes the effects of repeatability, terminal point conformity, and linearization, but does not include sensor error.
    Ambient Temperature Effect: Better than ±0.0020% per °C of input span or ±20ppm/°C, typical. Includes the combined effects of zero and span drift over temperature

    Environmental

    Operating temperature: -40 to 80°C (-40° to 176°F)
    Storage temperature: -40 to 85°C (-40 to 185°F)
    Relative humidity: 5 to 95% non-condensing
    Power requirement: 12-32V DC SELV (Safety Extra Low Voltage), 24mA maximum
    Isolation: 1500V AC peak. 250V AC (354V DC) continuous isolation between input and output circuits
    Shock and Vibration Immunity:
    Vibration: 4g, per IEC 60068-2-64
    Shock: 25g, per IEC 60068-2-27
    Electromagnetic Compatibility (EMC) Compliance:
    Radiated Emissions: BS EN 61000-6-4, CISPR 16
    RFI: BS EN 61000-6-2, IEC 61000-4-3
    Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6
    ESD: BS EN 61000-6-2, IEC 61000-4-2
    EFT: BS EN 61000-6-2, IEC 61000-4-4
    Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5
    Approvals:
    CE compliant. Designed for UL/cUL Class I Division 2 Groups ABCD, ATEX / IECEx Zone 2. II 3 G Ex nA IIC T4 Gc -40°C < Ta < +80°C

    Physical

    General: General-purpose enclosure designed for mounting on 35mm “T-type” DIN rail
    Case Material: Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General-purpose NEMA Type 1 enclosure
    I/O Connectors: Removable plug-in terminal blocks rated for 12A/250V; AWG #26-12, stranded or solid copper wire
    Dimensions: 12.5 x 114.5 x 99.0 mm (0.5 x 4.51 x 3.90 inches)
    Shipping Weight: 0.22 kg (0.5 pounds) packed

     

  • Features & Benefits

    • Easy setup and digital calibration via USB with Windows configuration software
    • Measures frequency or duty cycle and interfaces many input types up to 100KHz
    • Accepts input amplitudes up to 120Vrms (±170V DC, unipolar or bipolar)
    • Adjustable 0Hz cut-off, sample averaging, debounce, and output update time
    • Software configurable pull-up/down resistors ( 4V DC input pull-up for sensors/tranducers)
    • 1500V isolation between input/output circuits
    • Space-saving 12.5mm (0.5 inch) unit with pluggable terminals for convenient wiring
    • Fast response time and high accuracy
    • Supports normal or reverse-acting output
    • Supports sink or source output wiring
    • NAMUR-compliant output loop current
    • Shock (25g) and vibration (4g) resistant
    • Wide ambient operation (-40 to 80°C)
    • CE compliant. UL/cUL Class I Div 2, ATEX / IECEx Zone 2 approvals

     

  • Specs & Data Sheets

    Specifications

    Manuals

    TT239 User Manual (Log in to download the file)

  • Software

    TT230 Series Windows Configuration Software (Log in to download the file)
    Agility™ Config Tool (Wireless) (Log in to download the file)
  • Accessories

    • Compare

      Agility™ Config Tool (Wireless)

      • Wireless Agility™ Config Tool mobile application
      • For Acromag microBlox I/O Modules and Limit Alarms
      • Download available on Google Play and iTunes for free
      • Download Windows configuration software from the software tab below
      Read more
    • Compare

      PS5R: Slim Line Power Supplies

      • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
      • Universal Input (85-264V AC / 100-370V DC)
      • Lightweight and compact size
      $95$245
      Select options
    • Compare

      TTC-SIP: Software

      • Software Interface Package for Acromag DT, ST, TT Series Transmitters and SP, uBSP Series Signal Splitters.
      • Includes configuration sofware CD-ROM (5040-xxx), isolator (USB-ISOLATOR) and two USB cable (4001-112, 4001-113) (Recommend one kit per customer.)
      • Easy setup and digital calibration via USB with Windows configuration software.
      • Download the configuration software only - from the Software Tab
      $170
      Select options
    • Compare

      USB Isolator

      • USB-powered, USB 2.0 and 1.1 compatible
      • 1500V AC / 2100V DC isolation
      • No drivers required
      This compact, industrial-grade isolator provides a high-voltage isolation barrier between a computer and a connected USB device.
      $110
      Select options
  • Additional information

    Additional information

    Weight 8 oz
    Dimensions 4.51 × 0.5 × 3.9 in
    Part Number

    TT239-0600: Two-wire, isolated freq

    Configuration

    Agility Mobile App, Factory Calibration, USB Configuration, Windows Software Configuration

    Product Series

    TT230 Series

    Power

    Loop Power