Product short description:
- Single input, dual output (splitter)
- 12-36V DC SELV, 90-250V AC
- Provides two identical outputs from one input signal
These units receive 4-20mA process current inputs and provide isolated 4-20mA output signals. Each channel operates independently and is isolated from the others to prevent interaction between channels. Galvanic isolation eliminates ground loops, reduces noise, and blocks transient signals.
These AC/DC-powered signal splitters receive 4-20mA process current inputs and provide isolated 4-20mA output signals. Each channel operates independently and is isolated from the others to prevent interaction between channels. Galvanic isolation eliminates ground loops, reduces noise, and blocks transient signals.
Units are shipped with factory calibration for quick installation. These isolators also automatically compensate for load resistance variations, so re-calibration is rarely necessary. However, adjustable zero and span trim pots are provided to ensure precise calibration for maintenance requirements and long term serviceability.
These isolators generate a 24V input excitation supply suitable for powering one or two 2-wire transmitters. The supply is current limited at each output to prevent any excitation short from pulling down the internal power supply. The internal DC supply improves system performance by isolating loops on a single or dual channel basis. It saves space, complexity, and the expense of installing additional supplies to power your field loops.
Input / Output Ranges:
4 to 20mA DC input
4 to 20mA DC output
Power Requirement:
12-36V DC
90-250V AC (125V DC ±10%)
Four-wire isolated transmitter
Approvals:
CE marked. UL, cUL listed.
Class I, Division 2, Groups A, B, C, D
Performance Specifications
Reference Test Conditions: Input/output current 4 to 20mA; Output load 250 ohms; Power 24V DC or 115V AC; 77°F (25°C).
Input Range: 4 to 20mA input (each channel).
Input Burden:
Voltage drop (631T, 632T): Less than 1.5V (75 ohms) at full scale.
Voltage drop (633T): Less than 3.0V (150 ohms) at full scale.
Input Overvoltage Protection: Bipolar Transient Voltage Suppressors (TVS).
Input Excitation: 24V DC ±10%, 22mA maximum each. Fully isolated. Includes independent current limiting at EXC1 and EXC2 near 23mA, each.
Output Range: 4-20mA DC output (each channel).
Output Trim Range: Zero and full-scale adjustment to ±4%.
Output Limiting: Outputs are limited to 27mA.
Output Load:
0 to 1000 ohms (631T).
0 to 950 ohms (632T, 633T).
Output Load Resistance Effect: Less than ±0.01% of output span effect for a ±100 ohm change in load resistance.
Output Response Time (for input step change): 25mS typical to 98% of final output value.
Accuracy: ±0.05% of output span. Error includes the combined effects of isolator repeatability, hysteresis, terminal point linearity and adjustment resolution.
Temperature Drift: Better than ±50ppm/°C (±0.005%/°C) over the ambient temperature range. This specification includes the combined effects of zero and span over temperature.
Calibration: Two 15-turn potentiometers (zero and span) per output channel, accessible from front of the unit.
Bandwidth: -3dB at 50Hz, typical with a 500 ohm load.
Noise Rejection:
Common mode: Better than 100dB at 60Hz, typical.
Normal mode: -6dB at 60Hz, typical, 500 ohm load.
LED Indicators:
Green, one LED per output channel.
Constant ON indicates power applied.
Environmental
Ambient Temperature:
Operating: -25 to 75°C (-13 to 167°F), [if excitation supplies are used on 632T or 633T -25 to 60°C (-13 to 140°F)]
Storage: -40 to 85°C (-40 to 185°F)
Relative Humidity: 5 to 95%.
Power Requirement:
DC-powered units: 12-36V DC SELV.
AC-powered units: 90-250V AC (125V DC ±10%)
631T: 1.5 watts without excitation, 2.4 watts with excitation.
632T, 633T: 3.0 watts without excitation, 4.8 watts with excitation.
Isolation: Inputs, outputs, individual channels, power, and excitation supplies are isolated from each other for common-mode voltages up to 250V AC, or 354V DC off ground, on a continuous basis (will withstand 1500V AC dielectric strength test for one minute without breakdown).
Electromagnetic Field Immunity (EMI): Less than ±0.25% of output span effect under the influence of electromagnetic fields from switching solenoids, commutator motors, and drill motors.
Meets Immunity Standards Per EN50082-1
Electrostatic Discharge (ESD) Immunity:
4KV direct contact and 8KV air-discharge to the enclosure port per EN61000-4-2.
Radiated Field Immunity (RFI): 10V/M, 80 to 1000MHz AM and 900MHz keyed carrier, per EN61000-4-3 and ENV50204.
Electrical Fast Transient Immunity (EFT): 2KV to power and 1KV to signal I/O per EN61000-4-4.
Conducted RF Immunity (CRFI): 10Vrms, 150KHz to 80MHz, per EN61000-4-6.
Surge Immunity: 0.5KV per EN61000-4-5.
Emissions Per European Norm EN50081-1
Radiated Frequency Emissions:
30 to 1000MHz per EN55022 Class B.
Approvals:
CE marked, UL & cUL listed.
Hazardous Locations: Class I: Div. 2; Groups A, B, C, D
Physical
Enclosure: Case: Self-extinguishing NYLON type 6.6 polyamide thermoplastic UL94 V-2 NEMA Type 1 enclosure.
Connectors (Removable Terminal Blocks): Wire Range: AWG #14-22 (AWG #12 stranded only).
Printed Circuit Boards: Military grade FR-4 epoxy glass circuit board.
Dimensions:
1.05W x 4.68H x 4.35D inches.
26.7W x 95.3H x 110.5D millimeters.
- Two channels in a single unit saves space and reduces costs
- Signal splitter model provides two identical isolated outputs from one input signal
- Built-in isolated excitation supply with short circuit protection can drive up to two field 2-wire process loops
- Full isolation safely separates each input channel, each output channel, the excitation supply, and power
- Excellent accuracy and stability ensure reliable operation in hostile environments
- Low input burden keeps voltage drop to less than 1.5V for full-scale current
- Supports wide 0 to 1000 ohm load range and no trimming is required if the load varies
- Current limiting safely limits output to 27mA
- Pluggable terminals, zero/span trim pots and power LEDs make installation, maintenance, and long term service easy
- -25 to 75°C (-13 to 167°F) operation, [if excitation supplies are used on 633T -25 to 60°C (-13 to 140°F)]
-
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
$100 – $255Select options -
Terminal Block Replacements
- Simplifies wiring connections on Acromag I/O Modules
- Barrier strip or spring clamp terminal block kits
- Provide safe and secure wiring connections
$35 – $45Select options
Additional information
Weight | 8 oz |
---|---|
Dimensions | 1.1 × 5 × 4.5 in |
Part Number | 633T-0100: AC-powered, 633T-0500: DC-powered |
Product Series | 600 Series |
Power | AC Power, DC Power |
-
Description
These AC/DC-powered signal splitters receive 4-20mA process current inputs and provide isolated 4-20mA output signals. Each channel operates independently and is isolated from the others to prevent interaction between channels. Galvanic isolation eliminates ground loops, reduces noise, and blocks transient signals.
Units are shipped with factory calibration for quick installation. These isolators also automatically compensate for load resistance variations, so re-calibration is rarely necessary. However, adjustable zero and span trim pots are provided to ensure precise calibration for maintenance requirements and long term serviceability.
These isolators generate a 24V input excitation supply suitable for powering one or two 2-wire transmitters. The supply is current limited at each output to prevent any excitation short from pulling down the internal power supply. The internal DC supply improves system performance by isolating loops on a single or dual channel basis. It saves space, complexity, and the expense of installing additional supplies to power your field loops.
Input / Output Ranges:
4 to 20mA DC input
4 to 20mA DC outputPower Requirement:
12-36V DC
90-250V AC (125V DC ±10%)
Four-wire isolated transmitterApprovals:
CE marked. UL, cUL listed.
Class I, Division 2, Groups A, B, C, DPerformance Specifications
Reference Test Conditions: Input/output current 4 to 20mA; Output load 250 ohms; Power 24V DC or 115V AC; 77°F (25°C).
Input Range: 4 to 20mA input (each channel).
Input Burden:
Voltage drop (631T, 632T): Less than 1.5V (75 ohms) at full scale.
Voltage drop (633T): Less than 3.0V (150 ohms) at full scale.
Input Overvoltage Protection: Bipolar Transient Voltage Suppressors (TVS).
Input Excitation: 24V DC ±10%, 22mA maximum each. Fully isolated. Includes independent current limiting at EXC1 and EXC2 near 23mA, each.
Output Range: 4-20mA DC output (each channel).
Output Trim Range: Zero and full-scale adjustment to ±4%.
Output Limiting: Outputs are limited to 27mA.
Output Load:
0 to 1000 ohms (631T).
0 to 950 ohms (632T, 633T).
Output Load Resistance Effect: Less than ±0.01% of output span effect for a ±100 ohm change in load resistance.
Output Response Time (for input step change): 25mS typical to 98% of final output value.
Accuracy: ±0.05% of output span. Error includes the combined effects of isolator repeatability, hysteresis, terminal point linearity and adjustment resolution.
Temperature Drift: Better than ±50ppm/°C (±0.005%/°C) over the ambient temperature range. This specification includes the combined effects of zero and span over temperature.
Calibration: Two 15-turn potentiometers (zero and span) per output channel, accessible from front of the unit.
Bandwidth: -3dB at 50Hz, typical with a 500 ohm load.
Noise Rejection:
Common mode: Better than 100dB at 60Hz, typical.
Normal mode: -6dB at 60Hz, typical, 500 ohm load.
LED Indicators:
Green, one LED per output channel.
Constant ON indicates power applied.Environmental
Ambient Temperature:
Operating: -25 to 75°C (-13 to 167°F), [if excitation supplies are used on 632T or 633T -25 to 60°C (-13 to 140°F)]
Storage: -40 to 85°C (-40 to 185°F)
Relative Humidity: 5 to 95%.
Power Requirement:
DC-powered units: 12-36V DC SELV.
AC-powered units: 90-250V AC (125V DC ±10%)
631T: 1.5 watts without excitation, 2.4 watts with excitation.
632T, 633T: 3.0 watts without excitation, 4.8 watts with excitation.
Isolation: Inputs, outputs, individual channels, power, and excitation supplies are isolated from each other for common-mode voltages up to 250V AC, or 354V DC off ground, on a continuous basis (will withstand 1500V AC dielectric strength test for one minute without breakdown).
Electromagnetic Field Immunity (EMI): Less than ±0.25% of output span effect under the influence of electromagnetic fields from switching solenoids, commutator motors, and drill motors.
Meets Immunity Standards Per EN50082-1
Electrostatic Discharge (ESD) Immunity:
4KV direct contact and 8KV air-discharge to the enclosure port per EN61000-4-2.
Radiated Field Immunity (RFI): 10V/M, 80 to 1000MHz AM and 900MHz keyed carrier, per EN61000-4-3 and ENV50204.
Electrical Fast Transient Immunity (EFT): 2KV to power and 1KV to signal I/O per EN61000-4-4.
Conducted RF Immunity (CRFI): 10Vrms, 150KHz to 80MHz, per EN61000-4-6.
Surge Immunity: 0.5KV per EN61000-4-5.
Emissions Per European Norm EN50081-1
Radiated Frequency Emissions:
30 to 1000MHz per EN55022 Class B.
Approvals:
CE marked, UL & cUL listed.
Hazardous Locations: Class I: Div. 2; Groups A, B, C, DPhysical
Enclosure: Case: Self-extinguishing NYLON type 6.6 polyamide thermoplastic UL94 V-2 NEMA Type 1 enclosure.
Connectors (Removable Terminal Blocks): Wire Range: AWG #14-22 (AWG #12 stranded only).
Printed Circuit Boards: Military grade FR-4 epoxy glass circuit board.
Dimensions:
1.05W x 4.68H x 4.35D inches.
26.7W x 95.3H x 110.5D millimeters. -
Features & Benefits
- Two channels in a single unit saves space and reduces costs
- Signal splitter model provides two identical isolated outputs from one input signal
- Built-in isolated excitation supply with short circuit protection can drive up to two field 2-wire process loops
- Full isolation safely separates each input channel, each output channel, the excitation supply, and power
- Excellent accuracy and stability ensure reliable operation in hostile environments
- Low input burden keeps voltage drop to less than 1.5V for full-scale current
- Supports wide 0 to 1000 ohm load range and no trimming is required if the load varies
- Current limiting safely limits output to 27mA
- Pluggable terminals, zero/span trim pots and power LEDs make installation, maintenance, and long term service easy
- -25 to 75°C (-13 to 167°F) operation, [if excitation supplies are used on 633T -25 to 60°C (-13 to 140°F)]
-
Tech Papers
How to Re-transmit and Isolate 4-20mA Signals from Remotely-Mounted 3-Wire Gas Detection Sensors Application NoteDefining the Problem: Typically, signals from 3-wire remote sensors monitoring combustible and toxic gases are transmitted directly to the remote gas monitor or controller. However, there are cases when it’s desirable to send the signal to more than one destination. This can either be accomplished by re-transmitting the existing signal to additional locations or by...How to Use Acromag 600T Series Isolated Transmitters Application NoteApplication 1 Re-transmitting a signal from a two-wire loop to a second location. Solution Use either a model 651T-0600 (single channel) or 652T-0600 (dual channel) transmitter. Application 2 Splitting a signal from a two-wire loop: two outputs for different locations. Solution Use either a 653T-0600 (single input, dual output) or 652T-0600 (dual input, dual output)... -
Specs & Data Sheets
-
Accessories
-
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
$100 – $255Select options -
Terminal Block Replacements
- Simplifies wiring connections on Acromag I/O Modules
- Barrier strip or spring clamp terminal block kits
- Provide safe and secure wiring connections
$35 – $45Select options
-
Additional information
Additional information
Weight 8 oz Dimensions 1.1 × 5 × 4.5 in Part Number 633T-0100: AC-powered, 633T-0500: DC-powered
Product Series 600 Series
Power AC Power, DC Power
Please login to submit this form.