Click to zoom
$195

Please sign in or register to see model options and to add products to your cart.

Product short description:
  • Potentometer / slidewire, thermister input
  • 4 to 20mA output (sink / source)
  • 12-32V DC loop / local power
  • USB configuration

The TT234 model is a space-saving two-wire transmitter that isolates and converts a resistive sensor input to a proportional 4-20mA signal. Power is received from the output loop current or a DC supply when using a three-wire connection.

Click here to watch a short AcroMaggie video highlighting the TT230 Series.

[DISPLAY_ULTIMATE_PLUS]

The TT234 model is a space-saving two-wire transmitter that isolates and converts a resistive sensor input to a proportional 4-20mA signal. Power is received from the output loop current or a DC supply when using a three-wire connection. The transmitter provides sensor excitation plus performs linearization, lead-wire compensation, and lead-break detection.

Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software.

Advanced signal processing capabilities, variable range input, and convenient USB programming make this instrument a very versatile temperature measurement device. These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.

Performance Specifications

IMPORTANT: To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends the use of their USB-ISOLATOR when configuring a TT230 Series transmitter.

USB Interface

USB Connector: USB Mini-B type socket, 5-pin.

USB Data Rate: 12Mbps. USB v1.1 and 2.0 compatible.

USB Transient Protection: Transient voltage suppression on power and data lines.

USB Cable Length: 5.0 meters maximum.

Driver: Not required. Uses built-in Human Interface Device (HID) USB drivers of the Windows operating system.

Input

Default Configuration: Pot/slidewire, 0% to 100% input, 4-20mA output, downscale break detect, medium filter.

Input Configuration
Two- or three-wire sensor input connections.
User-configurable thermistor linearization table has preset curves for resistances below at 25°C.
Programs in °C, °F, °K, or ohmic integer values only.

Input Ranges
Input  Type                             Input Range                                     Accuracy
Potentiometer                  0 to 100% (100 to 100KΩ)         < ±0.01% of span
Rheostat                         100 to 1MΩ                                          < ±0.5% of input
Thermistor 2252Ω       -40 to 100°C (-40 to 212°F)           < ±0.05°C (±0.09°F)
Thermistor 2752Ω       -40 to 100°C                                       < ±0.05°C (±0.09°F)
Thermistor 2795Ω       -40 to 100°C                                       < ±0.05°C (±0.09°F)
Thermistor 3kΩ            -40 to 100°C                                       < ±0.05°C (±0.09°F)
Thermistor 5kΩ            -40 to 100°C                                       < ±0.05°C (±0.09°F)
Thermistor 10kΩ         -40 to 100°C                                        < ±0.05°C (±0.09°F)
Thermistor 30kΩ         -40 to 100°C                                        < ±0.05°C (±0.09°F)
Custom thermistor    100 to 1MΩ                                           < ±0.5% of input

Input Scaling Adjust
Zero: 0 to 95% of range, typical.
Full scale: 5 to 100% of full scale range, typical.

Excitation Voltage
Thermistor/rheostat: 1.25V DC, typical.
Potentiometer: 0.3V DC, limited to 3.35mA, typical.

Lead Break (Sensor Burnout) Detection: Configurable for either upscale or downscale on thermistor or rheostat inputs. Downscale only on potentiometer/slidewire inputs.

Output

Output Range: 4 to 20mA DC.
Under-range capability 3.5mA.
Over-range capability 24mA.

Output Compliance
Rload = (Vsupply – 11V) / 0.020A.
Rload = 0 to 650 ohms @ 24V DC.

Output DAC Resolution: 16-bit D/A converter.

Output Accuracy: Better than ±0.05% of span, typical (±0.1% max) for nominal input spans. Includes the effects of repeatability, terminal point conformity, and linearization, but does not include sensor error.

Ambient Temperature Effect: Better than ±0.008% per °C of input span or ±80ppm/°C, typical. Includes the combined effects of zero and span drift over temperature.

Output Response Time (for step input change)
No filter                 11ms
Low filter              40ms
Medium filter    150ms
High filter         1200ms

Environmental

Operating temperature: -40 to 80°C (-40° to 176°F).

Storage temperature: -40 to 85°C (-40 to 185°F).

Relative humidity: 5 to 95% non-condensing.

Power Requirement: 12-32V DC SELV (Safety Extra Low Voltage), 24mA maximum.

Shock and Vibration Immunity
Vibration: 4g, per IEC 60068-2-6.
Shock: 25g, per IEC 60068-2-27.

Electromagnetic Compatibility (EMC) Compliance
Radiated Emissions: BS EN 61000-6-4, CISPR 16.
RFI: BS EN 61000-6-2, IEC 61000-4-3.
Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6.
ESD: BS EN 61000-6-2, IEC 61000-4-2.
EFT: BS EN 61000-6-2, IEC 61000-4-4.
Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5.

Approvals: CE compliant. Designed for UL/cUL Class I Division 2 Groups ABCD, ATEX / IECEx Zone 2. II 3 G Ex nA IIC T4 Gc -40°C < Ta < +80°C.

Physical

General: General-purpose enclosure designed for mounting on 35mm “T-type” DIN rail.

Case Material: Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General-purpose NEMA Type 1 enclosure.

I/O Connectors: Removable plug-in terminal blocks rated for 12A/250V; AWG #26-12, stranded or solid copper wire.

Dimensions: 12.5 x 114.5 x 99.0 mm (0.5 x 4.51 x 3.90 inches).

Shipping Weight: 0.22 kg (0.5 pounds) packed.

  • Easy setup and digital calibration via USB with Windows configuration software
  • Interfaces 100-100kΩ potentiometer/slidewire and 100-1MΩ NTC thermistor/rheostat inputs
  • Customizable thermistor linearization table with preset curves for popular resistances
  • 1500V isolation between input/output circuits
  • Space-saving 12.5mm (0.5 inch) unit with pluggable terminals for convenient wiring
  • High accuracy, linearity, stability, and reliability
  • Supports normal or reverse-acting output
  • Supports sink or source output wiring
  • User-selectable filtering (none, low, med., high)
  • Fast response (as low as 11ms)
  • Selectable upscale or downscale operation for sensor errors and lead-break detection
  • NAMUR-compliant output loop current
  • Shock (25g) and vibration (4g) resistant
  • Wide ambient operation (-40 to 80°C)
  • CE compliant. UL/cUL Class I Div 2, ATEX / IECEx Zone 2 approvals

Manuals

TT234 User Manual (Log in to download the file)

TT230 Series Windows Configuration Software (Log in to download the file)
Agility Config Tool (Tethered) (Log in to download the file)
  • Compare

    Agility™ Config Tool (Tethered)

    • Tethered Agility™ Config Tool mobile application
    • For Acromag SP Series Signal Splitters and most TT Series Transmitters
    • Download available on Google Play for free.
    • Download Windows configuration software from the software tab below.
    Read more
  • Compare

    PS5R: Slim Line Power Supplies

    • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
    • Universal Input (85-264V AC / 100-370V DC)
    • Lightweight and compact size
     
    $100$255
    Select options
  • Compare

    TTC-SIP: Software

    • Software Interface Package for Acromag DT, ST, TT Series Transmitters and SP, uBSP Series Signal Splitters.
    • Includes configuration sofware CD-ROM (5040-xxx), isolator (USB-ISOLATOR) and two USB cable (4001-112, 4001-113) (Recommend one kit per customer.)
    • Easy setup and digital calibration via USB with Windows configuration software.
    • Download the configuration software only - from the Software Tab
    $170
    Select options
  • Compare

    USB Isolator

    • USB-powered, USB 2.0 and 1.1 compatible
    • 1500V AC / 2100V DC isolation
    • No drivers required
    This compact, industrial-grade isolator provides a high-voltage isolation barrier between a computer and a connected USB device.    
    $110
    Select options

Additional information

Weight 8 oz
Dimensions 4.51 × 0.5 × 3.9 in
Part Number

TT234-0600: Transmitter

Configuration

Agility Mobile App, Factory Calibration, USB Configuration, Windows Software Configuration

Product Series

TT230 Series

Power

Loop Power

  • Description

    The TT234 model is a space-saving two-wire transmitter that isolates and converts a resistive sensor input to a proportional 4-20mA signal. Power is received from the output loop current or a DC supply when using a three-wire connection. The transmitter provides sensor excitation plus performs linearization, lead-wire compensation, and lead-break detection.

    Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software.

    Advanced signal processing capabilities, variable range input, and convenient USB programming make this instrument a very versatile temperature measurement device. These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.

    Performance Specifications

    IMPORTANT: To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends the use of their USB-ISOLATOR when configuring a TT230 Series transmitter.

    USB Interface

    USB Connector: USB Mini-B type socket, 5-pin.

    USB Data Rate: 12Mbps. USB v1.1 and 2.0 compatible.

    USB Transient Protection: Transient voltage suppression on power and data lines.

    USB Cable Length: 5.0 meters maximum.

    Driver: Not required. Uses built-in Human Interface Device (HID) USB drivers of the Windows operating system.

    Input

    Default Configuration: Pot/slidewire, 0% to 100% input, 4-20mA output, downscale break detect, medium filter.

    Input Configuration
    Two- or three-wire sensor input connections.
    User-configurable thermistor linearization table has preset curves for resistances below at 25°C.
    Programs in °C, °F, °K, or ohmic integer values only.

    Input Ranges
    Input  Type                             Input Range                                     Accuracy
    Potentiometer                  0 to 100% (100 to 100KΩ)         < ±0.01% of span
    Rheostat                         100 to 1MΩ                                          < ±0.5% of input
    Thermistor 2252Ω       -40 to 100°C (-40 to 212°F)           < ±0.05°C (±0.09°F)
    Thermistor 2752Ω       -40 to 100°C                                       < ±0.05°C (±0.09°F)
    Thermistor 2795Ω       -40 to 100°C                                       < ±0.05°C (±0.09°F)
    Thermistor 3kΩ            -40 to 100°C                                       < ±0.05°C (±0.09°F)
    Thermistor 5kΩ            -40 to 100°C                                       < ±0.05°C (±0.09°F)
    Thermistor 10kΩ         -40 to 100°C                                        < ±0.05°C (±0.09°F)
    Thermistor 30kΩ         -40 to 100°C                                        < ±0.05°C (±0.09°F)
    Custom thermistor    100 to 1MΩ                                           < ±0.5% of input

    Input Scaling Adjust
    Zero: 0 to 95% of range, typical.
    Full scale: 5 to 100% of full scale range, typical.

    Excitation Voltage
    Thermistor/rheostat: 1.25V DC, typical.
    Potentiometer: 0.3V DC, limited to 3.35mA, typical.

    Lead Break (Sensor Burnout) Detection: Configurable for either upscale or downscale on thermistor or rheostat inputs. Downscale only on potentiometer/slidewire inputs.

    Output

    Output Range: 4 to 20mA DC.
    Under-range capability 3.5mA.
    Over-range capability 24mA.

    Output Compliance
    Rload = (Vsupply – 11V) / 0.020A.
    Rload = 0 to 650 ohms @ 24V DC.

    Output DAC Resolution: 16-bit D/A converter.

    Output Accuracy: Better than ±0.05% of span, typical (±0.1% max) for nominal input spans. Includes the effects of repeatability, terminal point conformity, and linearization, but does not include sensor error.

    Ambient Temperature Effect: Better than ±0.008% per °C of input span or ±80ppm/°C, typical. Includes the combined effects of zero and span drift over temperature.

    Output Response Time (for step input change)
    No filter                 11ms
    Low filter              40ms
    Medium filter    150ms
    High filter         1200ms

    Environmental

    Operating temperature: -40 to 80°C (-40° to 176°F).

    Storage temperature: -40 to 85°C (-40 to 185°F).

    Relative humidity: 5 to 95% non-condensing.

    Power Requirement: 12-32V DC SELV (Safety Extra Low Voltage), 24mA maximum.

    Shock and Vibration Immunity
    Vibration: 4g, per IEC 60068-2-6.
    Shock: 25g, per IEC 60068-2-27.

    Electromagnetic Compatibility (EMC) Compliance
    Radiated Emissions: BS EN 61000-6-4, CISPR 16.
    RFI: BS EN 61000-6-2, IEC 61000-4-3.
    Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6.
    ESD: BS EN 61000-6-2, IEC 61000-4-2.
    EFT: BS EN 61000-6-2, IEC 61000-4-4.
    Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5.

    Approvals: CE compliant. Designed for UL/cUL Class I Division 2 Groups ABCD, ATEX / IECEx Zone 2. II 3 G Ex nA IIC T4 Gc -40°C < Ta < +80°C.

    Physical

    General: General-purpose enclosure designed for mounting on 35mm “T-type” DIN rail.

    Case Material: Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General-purpose NEMA Type 1 enclosure.

    I/O Connectors: Removable plug-in terminal blocks rated for 12A/250V; AWG #26-12, stranded or solid copper wire.

    Dimensions: 12.5 x 114.5 x 99.0 mm (0.5 x 4.51 x 3.90 inches).

    Shipping Weight: 0.22 kg (0.5 pounds) packed.

  • Features & Benefits

    • Easy setup and digital calibration via USB with Windows configuration software
    • Interfaces 100-100kΩ potentiometer/slidewire and 100-1MΩ NTC thermistor/rheostat inputs
    • Customizable thermistor linearization table with preset curves for popular resistances
    • 1500V isolation between input/output circuits
    • Space-saving 12.5mm (0.5 inch) unit with pluggable terminals for convenient wiring
    • High accuracy, linearity, stability, and reliability
    • Supports normal or reverse-acting output
    • Supports sink or source output wiring
    • User-selectable filtering (none, low, med., high)
    • Fast response (as low as 11ms)
    • Selectable upscale or downscale operation for sensor errors and lead-break detection
    • NAMUR-compliant output loop current
    • Shock (25g) and vibration (4g) resistant
    • Wide ambient operation (-40 to 80°C)
    • CE compliant. UL/cUL Class I Div 2, ATEX / IECEx Zone 2 approvals
  • Specs & Data Sheets

    Manuals

    TT234 User Manual (Log in to download the file)

  • Software

    TT230 Series Windows Configuration Software (Log in to download the file)
    Agility Config Tool (Tethered) (Log in to download the file)
  • Accessories

    • Compare

      Agility™ Config Tool (Tethered)

      • Tethered Agility™ Config Tool mobile application
      • For Acromag SP Series Signal Splitters and most TT Series Transmitters
      • Download available on Google Play for free.
      • Download Windows configuration software from the software tab below.
      Read more
    • Compare

      PS5R: Slim Line Power Supplies

      • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
      • Universal Input (85-264V AC / 100-370V DC)
      • Lightweight and compact size
       
      $100$255
      Select options
    • Compare

      TTC-SIP: Software

      • Software Interface Package for Acromag DT, ST, TT Series Transmitters and SP, uBSP Series Signal Splitters.
      • Includes configuration sofware CD-ROM (5040-xxx), isolator (USB-ISOLATOR) and two USB cable (4001-112, 4001-113) (Recommend one kit per customer.)
      • Easy setup and digital calibration via USB with Windows configuration software.
      • Download the configuration software only - from the Software Tab
      $170
      Select options
    • Compare

      USB Isolator

      • USB-powered, USB 2.0 and 1.1 compatible
      • 1500V AC / 2100V DC isolation
      • No drivers required
      This compact, industrial-grade isolator provides a high-voltage isolation barrier between a computer and a connected USB device.    
      $110
      Select options
  • Additional information

    Additional information

    Weight 8 oz
    Dimensions 4.51 × 0.5 × 3.9 in
    Part Number

    TT234-0600: Transmitter

    Configuration

    Agility Mobile App, Factory Calibration, USB Configuration, Windows Software Configuration

    Product Series

    TT230 Series

    Power

    Loop Power