655T, 656T: Single or Dual Channel, Thermocouple/milliVolt Input, Loop-powered Transmitter
Product short description:
- TC (types J, K T, R, S, E, B, N), ±1V DC, selectable range/type input
- 4 to 20mA DC output
- 12-50V DC from output loop power
- DIP-switch configuration, signal linearizer, push-button calibration
Models:
655T: Single TC/mV input channel
656T: Dual TC/mV input channel
These units accept universal thermocouple and millivolt input signals, provide isolation, and output proportional DC current signals. The output can also be linearized to the input sensor signal. Single-channel units are ideal for panel shops and end-users who require a high-density signal conditioner that can cover a broad range of temperature measurement applications.
Configuration is fast and easy. First, you select the input type with a simple DIP switch. Then, you set your zero/full-scale output values using a toggle switch on the front panel to increase or decrease the signal until you read the desired output value on your voltmeter. The toggles make it easy to calibrate a normal (proportional) or reverse-acting (inverse) response in seconds. After setting the desired calibration, just press the mode/set toggle and your configuration settings are safely saved to nonvolatile memory.
Both models provide high-voltage input isolation (output and power circuits share a common). On dual channel units, each channel operates independently, with inputs isolated from each other, to prevent interaction between channels.
Input Ranges:
TC types: J, K, T, R, S, E, B, N (DIP switch selection)
DC voltage: ±15.6mV to ±62.5mV, 0 to 1V DC
Output Ranges: 4 to 20mA DC
Power Requirement:
12 to 50V DC (loop-powered)
Two-wire transmitter
Approvals:
UL, cUL listed
Class I; Division 2; Groups A, B, C, D
Performance Specifications
General Input
Analog to Digital Converter (ADC): 16-bit S-D A/D converter
Noise Rejection
Normal Mode: Better than 40dB @ 60Hz
Common Mode: Better than 100dB @ 60Hz
Input Over-voltage Protection: Bipolar Transient Voltage Suppressors (TVS)
Thermocouple Input
Input Ranges (switch-selectable)
TC Type Temperature Range Accuracy
J -210 to 760°C (-346 to 1400°F) ±0.5°C
K 200 to 1372°C (-328 to 2502°F) ±0.5°C
T -260 to 400°C (-436 to 752°F) ±0.5°C
R -50 to 1768°C (-58 to 3214°F) ±1.0°C
S -50 to 1768°C (-58 to 3214°F) ±1.0°C
E -200 to 1000°C (-328 to 1832°F) ±0.5°C
B 260 to 1820°C (500 to 3308°F) ±1.0°C
N -230 to 1300°C (-382 to 2372°F) ±0.5°C
Span adjust: Full range. 100°C or 3mV minimum span recommended.
Zero adjust: 0 to 90 % of full range.
Thermocouple Linearization: On/off selectable
Thermocouple Break Detection: TC sensor failure can be configured for either upscale or downscale.
Cold Junction Compensation (CJC) Control: On/off selectable
milliVolt Input
Input Range
Ranges: ±15.6, ±31.3, ±62.5mV
0 to 0.125, 0.25, 0.5, 1.0V DC
Span adjust: 10 to 100% of range
Zero adjust: 0 to 90% of range
Output
Output Range: Range: 4 to 20mA DC, 3.8 to 22mA range typical
Output Compliance: Rload = (Vsupply – 12V) / 0.02A
Output Response Control: Proportional/inverse selectable
Ambient Temperature Effect: Better than ±0.006% of input span per °C or ±100ppm/°C, whichever is greater
Output Response Time (for input step change): 700mS typical to 98% of final output value
Environmental
Ambient Temperature:
Operating: -25 to 75°C (-13 to 167°F)
Storage: -40 to 85°C (-40 to 185°F)
Relative Humidity: 5 to 95%, non-condensing
Power Requirement: 12 to 50V DC @ 25mA for each output channel
Isolation: Inputs, outputs, and individual channels are isolated from each other for common-mode voltages up to 250V AC, or 354V DC off ground, on a continuous basis (will withstand 1500V AC dielectric strength test for one minute without breakdown).
Radiated Field Immunity (RFI): Complies with EN61000-4-3 Level 3 and EN50082-1
Electromagnetic Field Immunity (EMI): Less than ±0.25% of output span effect
Electrical Fast Transient (EFT): Complies with EN61000-4-4 Level 3 and EN50082-1
Electrostatic Discharge (ESD): Complies with EN61000-4-2 Level 3 and EN50082-1
Radiated Emissions: Meets or exceeds EN50081-1 for Class B equipment
Approvals
UL & cUL listed
Hazardous Locations: Class I: Div. 2; Groups A, B, C, D
Physical
Enclosure: Case: Self-extinguishing NYLON type 6.6 polyamide thermoplastic UL94 V-2 NEMA Type 1 enclosure.
Connectors (Removable Terminal Blocks): Wire Range: AWG #12-24
Printed Circuit Boards: Military grade FR-4 epoxy glass circuit board
Dimensions:
1.05W x 4.68H x 4.35D inches
26.7W x 118.9H x 110.5D millimeters
Shipping Weight: 1 pound (0.45 Kg) packed
- Selectable thermocouple input types offer flexibility to fit many applications.
- DIP switch-configuration and self-ranging technologies speed installation without pots, jumpers, or software.
- Linearizer function provides an output that is linear to the temperature or millivolt signal.
- Isolation eliminates ground loops, reduces noise, and blocks transient signals.
- Toggle-switch calibration simplifies field adjustments for faster and easier maintenance.
- Configuration lockout safety feature prevents tampering and accidental changes.
- Reverse-acting output capability enables inverse proportional control signals.
- Dual channel model saves space and reduces equipment costs.
- CJC control only requires a millivolt source to calibrate modules
- High-resolution sigma-delta A/D converters deliver superior accuracy for reliable measurements.
- Operating temperature range: -25 to 75°C (-13 to 167°F)
-
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
$95 – $245Select options
Additional information
Weight | 16 oz |
---|---|
Dimensions | 1.1 × 5 × 4.5 in |
Part Number | 655T-0600: single I/O channel; TC (J, K, T, R, S, E, B, N) or ±1V DC input, 4 to 20mA DC output, 655T-0600-C: single I/O channel; TC (J, K, T, R, S, E, B, N) or ±1V DC input, 4 to 20mA DC output, with factory calibration. Specify ranges at checkout, 656T-0600: dual I/O channels; TC (J, K, T, R, S, E, B, N) or ±1V DC input, 4 to 20mA DC output, 656T-0600-C: dual I/O channels; TC (J, K, T, R, S, E, B, N) or ±1V DC input, 4 to 20mA DC output, with factory calibration, 656T-E600: dual I/O channel economy version; TC J, K and 0-125mV input (no linearization); 4 to 20mA DC output (no inverse proportional (reverse) output), 656T-E600-C: dual I/O channel economy version; TC J, K and 0-125mV input (no linearization); 4 to 20mA DC output (no inverse proportional (reverse) output, with factory calibration. Specify ranges at checkout |
Product Series | 600 Series |
-
Description
Models:
655T: Single TC/mV input channel
656T: Dual TC/mV input channelThese units accept universal thermocouple and millivolt input signals, provide isolation, and output proportional DC current signals. The output can also be linearized to the input sensor signal. Single-channel units are ideal for panel shops and end-users who require a high-density signal conditioner that can cover a broad range of temperature measurement applications.
Configuration is fast and easy. First, you select the input type with a simple DIP switch. Then, you set your zero/full-scale output values using a toggle switch on the front panel to increase or decrease the signal until you read the desired output value on your voltmeter. The toggles make it easy to calibrate a normal (proportional) or reverse-acting (inverse) response in seconds. After setting the desired calibration, just press the mode/set toggle and your configuration settings are safely saved to nonvolatile memory.
Both models provide high-voltage input isolation (output and power circuits share a common). On dual channel units, each channel operates independently, with inputs isolated from each other, to prevent interaction between channels.
Input Ranges:
TC types: J, K, T, R, S, E, B, N (DIP switch selection)
DC voltage: ±15.6mV to ±62.5mV, 0 to 1V DCOutput Ranges: 4 to 20mA DC
Power Requirement:
12 to 50V DC (loop-powered)
Two-wire transmitterApprovals:
UL, cUL listed
Class I; Division 2; Groups A, B, C, DPerformance Specifications
General Input
Analog to Digital Converter (ADC): 16-bit S-D A/D converter
Noise Rejection
Normal Mode: Better than 40dB @ 60Hz
Common Mode: Better than 100dB @ 60Hz
Input Over-voltage Protection: Bipolar Transient Voltage Suppressors (TVS)Thermocouple Input
Input Ranges (switch-selectable)
TC Type Temperature Range Accuracy
J -210 to 760°C (-346 to 1400°F) ±0.5°C
K 200 to 1372°C (-328 to 2502°F) ±0.5°C
T -260 to 400°C (-436 to 752°F) ±0.5°C
R -50 to 1768°C (-58 to 3214°F) ±1.0°C
S -50 to 1768°C (-58 to 3214°F) ±1.0°C
E -200 to 1000°C (-328 to 1832°F) ±0.5°C
B 260 to 1820°C (500 to 3308°F) ±1.0°C
N -230 to 1300°C (-382 to 2372°F) ±0.5°C
Span adjust: Full range. 100°C or 3mV minimum span recommended.
Zero adjust: 0 to 90 % of full range.Thermocouple Linearization: On/off selectable
Thermocouple Break Detection: TC sensor failure can be configured for either upscale or downscale.
Cold Junction Compensation (CJC) Control: On/off selectablemilliVolt Input
Input Range
Ranges: ±15.6, ±31.3, ±62.5mV
0 to 0.125, 0.25, 0.5, 1.0V DC
Span adjust: 10 to 100% of range
Zero adjust: 0 to 90% of rangeOutput
Output Range: Range: 4 to 20mA DC, 3.8 to 22mA range typical
Output Compliance: Rload = (Vsupply – 12V) / 0.02A
Output Response Control: Proportional/inverse selectable
Ambient Temperature Effect: Better than ±0.006% of input span per °C or ±100ppm/°C, whichever is greater
Output Response Time (for input step change): 700mS typical to 98% of final output valueEnvironmental
Ambient Temperature:
Operating: -25 to 75°C (-13 to 167°F)
Storage: -40 to 85°C (-40 to 185°F)
Relative Humidity: 5 to 95%, non-condensing
Power Requirement: 12 to 50V DC @ 25mA for each output channel
Isolation: Inputs, outputs, and individual channels are isolated from each other for common-mode voltages up to 250V AC, or 354V DC off ground, on a continuous basis (will withstand 1500V AC dielectric strength test for one minute without breakdown).
Radiated Field Immunity (RFI): Complies with EN61000-4-3 Level 3 and EN50082-1
Electromagnetic Field Immunity (EMI): Less than ±0.25% of output span effect
Electrical Fast Transient (EFT): Complies with EN61000-4-4 Level 3 and EN50082-1
Electrostatic Discharge (ESD): Complies with EN61000-4-2 Level 3 and EN50082-1
Radiated Emissions: Meets or exceeds EN50081-1 for Class B equipment
Approvals
UL & cUL listed
Hazardous Locations: Class I: Div. 2; Groups A, B, C, DPhysical
Enclosure: Case: Self-extinguishing NYLON type 6.6 polyamide thermoplastic UL94 V-2 NEMA Type 1 enclosure.
Connectors (Removable Terminal Blocks): Wire Range: AWG #12-24
Printed Circuit Boards: Military grade FR-4 epoxy glass circuit board
Dimensions:
1.05W x 4.68H x 4.35D inches
26.7W x 118.9H x 110.5D millimeters
Shipping Weight: 1 pound (0.45 Kg) packed -
Features & Benefits
- Selectable thermocouple input types offer flexibility to fit many applications.
- DIP switch-configuration and self-ranging technologies speed installation without pots, jumpers, or software.
- Linearizer function provides an output that is linear to the temperature or millivolt signal.
- Isolation eliminates ground loops, reduces noise, and blocks transient signals.
- Toggle-switch calibration simplifies field adjustments for faster and easier maintenance.
- Configuration lockout safety feature prevents tampering and accidental changes.
- Reverse-acting output capability enables inverse proportional control signals.
- Dual channel model saves space and reduces equipment costs.
- CJC control only requires a millivolt source to calibrate modules
- High-resolution sigma-delta A/D converters deliver superior accuracy for reliable measurements.
- Operating temperature range: -25 to 75°C (-13 to 167°F)
-
Tech Papers
How to use Thermocouple Transmitters to Monitor Temperatures in Paint Systems Application NoteThis document illustrates using Acromag’s TT330 Series to monitor high temperatures in an automotive paint curing oven and transmit to the existing PLC 4-20mA input card/software setup. Defining the Problem The area around an auto manufacturer’s paint curing ovens is at elevated temperatures affecting the performance of locally installed instrumentation. Placing Signal Conditioners rated for...Minimizing Measurement Errors When Making Thermocouple to Transmitter Connections White Paper (Log in to view the file)How To Prevent Temperature Measurement Errors It will give you a keen understanding of the three basic laws of thermocouples: Homogeneous materials, Intermediate Metals, and Successive/Intermediate Temperatures. It is helpful in weeding out potential sources of error in a thermocouple measurement system.Temperature Measurement Using Thermocouples White Paper (Log in to view the file)The Basics of Temperature Measurement Using Thermocouples Choosing a temperature sensor for an application is not as simple as picking a thermocouple type with a compatible temperature range. You must give consideration to the sensor material type, the application temperature range, the relative sensitivity of the sensor, the limitations of its insulation material, and its... -
Specs & Data Sheets
-
Accessories
-
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
$95 – $245Select options
-
Additional information
Additional information
Weight 16 oz Dimensions 1.1 × 5 × 4.5 in Part Number 655T-0600: single I/O channel; TC (J, K, T, R, S, E, B, N) or ±1V DC input, 4 to 20mA DC output, 655T-0600-C: single I/O channel; TC (J, K, T, R, S, E, B, N) or ±1V DC input, 4 to 20mA DC output, with factory calibration. Specify ranges at checkout, 656T-0600: dual I/O channels; TC (J, K, T, R, S, E, B, N) or ±1V DC input, 4 to 20mA DC output, 656T-0600-C: dual I/O channels; TC (J, K, T, R, S, E, B, N) or ±1V DC input, 4 to 20mA DC output, with factory calibration, 656T-E600: dual I/O channel economy version; TC J, K and 0-125mV input (no linearization); 4 to 20mA DC output (no inverse proportional (reverse) output), 656T-E600-C: dual I/O channel economy version; TC J, K and 0-125mV input (no linearization); 4 to 20mA DC output (no inverse proportional (reverse) output, with factory calibration. Specify ranges at checkout
Product Series 600 Series
Please login to submit this form.