250T-TC, 350T-TC, 450T-TC Loop, DC, or AC-Power Transmitter
Product short description:
- J, K, T, E, R, S, B Thermocouple Input
- DC Voltage or DC Current Output
These models convert sensor inputs to proportional process current or voltage output signals. Excellent accuracy and stability ensure reliable measurements in harsh industrial environments. 3-way isolation. Input, output, and power circuits are isolated from each other.
Models
250T: Loop-powered transmitter series
350T: DC-powered transmitter series
450T: AC-powered transmitter series
Performance Specifications
Input Ranges:
Thermocouple types J, K, T, R, S, E, B
Linearized thermocouple (custom ranges)
Output Ranges:
DC Current: 4 to 20mA
DC voltage: 0 to 5V or 0 to 10V
Power Requirements:
250T: 12 to 50V DC @ 20mA (loop-powered)
350T: DC Voltage Source
Output Range Power
4 to 20mA 10 to 36V DC @ 30mA
0 to 5V 10 to 36V DC @ 9mA
0 to 10V 12.5 to 36V DC @ 9mA
450T: 115V or 230V AC, ±10%, 50 to 60Hz
Output Range Power
4 to 20mA 115V AC @ 0.050A
4 to 20mA 230V AC @ 0.025A
0 to 5V, 0 to 10V 115V AC @ 0.020A
0 to 5V, 0 to 10V 230V AC @ 0.010A
Ambient Temperature Range:
Operating: -13 to 185°F (-25 to 85°C)
Storage: -40 to 185°F (-40 to 85°C)
Accuracy:
±0.1% of calibrated span or ±0.01mV, whichever is greater. Includes repeat-ability, hysteresis, terminal point linearity, and adjustment resolution.
Ambient Temperature Effect:
Less than ±0.01% of output span per °F (±0.018% per °C).
±0.025% of output span per °F (±0.045% per °C) for narrow span units.
(Specification includes the combined effects of zero and span over temperature).
Noise Resistance:
RFI: Less than ±0.5% ,of output span effect.
EMI: Less than ±0.25% of output span effect.
Noise Rejection:
Common Mode: 130dB at 60Hz, 100 ohm unbalance
Normal Mode: 30dB at 60Hz, 100 ohm source
Response Time: Output reaches 98% of output span in 300mS.
Bandwidth: -3dB at 3 Hz, typical
Output Compliance:
250T: RLOAD (max.) = (VSUPPLY – 12V) / 20mA
350T: RLOAD (max.) = (VSUPPLY – 2.5V) / 20mA
450T: RLOAD = 600 ohms
Linearization (-xLxx) Option:
5-segment TC linearizer provides minimum 10 to 1 improvement ±0.1% in the linearity curve.
- Excellent accuracy and stability ensure reliable measurements in harsh industrial environments
- Field-selectable input types reduce stocking requirements
- Thermocouple reference junction compensation reduces drift and corrects non-linearity
- TC linearizer (5-slope) improves accuracy
- TC break detection indicates open circuit failures with selectable up/downscale operation
- RFI and EMI resistance minimize the effects of environmental noise
- 75% span adjustment enables precise application calibration
- 1500V AC peak isolation (250V AC or 354V DC continuous) prevents ground loops
- 250T models: Input isolated from output/power
- 350T models:Input isolated from output and power. Output and power share a common
- 450T models: 3-way isolation. Input, output, and power circuits are isolated from each other
- Operating temperature range: -13 to 185°F (-25 to 85°C)
- DIN rail G or T mount
- No certification/approval required
Specifications
Additional information
Weight | 16 oz |
---|---|
Dimensions | 3 × 1 × 3.2 in |
Part Number | 250T-TC1-DIN-NCR: 12 to 50V DC @ 20mA (loop-power) power, 350T-TC1-Y-DIN-NCR: DC-power; 4 to 20mA DC output, 450T-TC1-Y-1-DIN-NCR: AC-power; 4 to 20mA DC output; 115V AC power |
Product Series | FlatPack Series |
-
Description
These models convert sensor inputs to proportional process current or voltage output signals. Excellent accuracy and stability ensure reliable measurements in harsh industrial environments. 3-way isolation. Input, output, and power circuits are isolated from each other.
Models
250T: Loop-powered transmitter series
350T: DC-powered transmitter series
450T: AC-powered transmitter seriesPerformance Specifications
Input Ranges:
Thermocouple types J, K, T, R, S, E, B
Linearized thermocouple (custom ranges)
Output Ranges:
DC Current: 4 to 20mA
DC voltage: 0 to 5V or 0 to 10V
Power Requirements:
250T: 12 to 50V DC @ 20mA (loop-powered)350T: DC Voltage Source
Output Range Power
4 to 20mA 10 to 36V DC @ 30mA
0 to 5V 10 to 36V DC @ 9mA
0 to 10V 12.5 to 36V DC @ 9mA450T: 115V or 230V AC, ±10%, 50 to 60Hz
Output Range Power
4 to 20mA 115V AC @ 0.050A
4 to 20mA 230V AC @ 0.025A
0 to 5V, 0 to 10V 115V AC @ 0.020A
0 to 5V, 0 to 10V 230V AC @ 0.010AAmbient Temperature Range:
Operating: -13 to 185°F (-25 to 85°C)
Storage: -40 to 185°F (-40 to 85°C)
Accuracy:
±0.1% of calibrated span or ±0.01mV, whichever is greater. Includes repeat-ability, hysteresis, terminal point linearity, and adjustment resolution.
Ambient Temperature Effect:
Less than ±0.01% of output span per °F (±0.018% per °C).
±0.025% of output span per °F (±0.045% per °C) for narrow span units.
(Specification includes the combined effects of zero and span over temperature).
Noise Resistance:
RFI: Less than ±0.5% ,of output span effect.
EMI: Less than ±0.25% of output span effect.
Noise Rejection:
Common Mode: 130dB at 60Hz, 100 ohm unbalance
Normal Mode: 30dB at 60Hz, 100 ohm source
Response Time: Output reaches 98% of output span in 300mS.
Bandwidth: -3dB at 3 Hz, typical
Output Compliance:
250T: RLOAD (max.) = (VSUPPLY – 12V) / 20mA
350T: RLOAD (max.) = (VSUPPLY – 2.5V) / 20mA
450T: RLOAD = 600 ohms
Linearization (-xLxx) Option:
5-segment TC linearizer provides minimum 10 to 1 improvement ±0.1% in the linearity curve. -
Features & Benefits
- Excellent accuracy and stability ensure reliable measurements in harsh industrial environments
- Field-selectable input types reduce stocking requirements
- Thermocouple reference junction compensation reduces drift and corrects non-linearity
- TC linearizer (5-slope) improves accuracy
- TC break detection indicates open circuit failures with selectable up/downscale operation
- RFI and EMI resistance minimize the effects of environmental noise
- 75% span adjustment enables precise application calibration
- 1500V AC peak isolation (250V AC or 354V DC continuous) prevents ground loops
- 250T models: Input isolated from output/power
- 350T models:Input isolated from output and power. Output and power share a common
- 450T models: 3-way isolation. Input, output, and power circuits are isolated from each other
- Operating temperature range: -13 to 185°F (-25 to 85°C)
- DIN rail G or T mount
- No certification/approval required
-
Tech Papers
Minimizing Measurement Errors When Making Thermocouple to Transmitter Connections White Paper (Log in to view the file)How To Prevent Temperature Measurement Errors It will give you a keen understanding of the three basic laws of thermocouples: Homogeneous materials, Intermediate Metals, and Successive/Intermediate Temperatures. It is helpful in weeding out potential sources of error in a thermocouple measurement system.Temperature Measurement Using Thermocouples White Paper (Log in to view the file)The Basics of Temperature Measurement Using Thermocouples Choosing a temperature sensor for an application is not as simple as picking a thermocouple type with a compatible temperature range. You must give consideration to the sensor material type, the application temperature range, the relative sensitivity of the sensor, the limitations of its insulation material, and its... -
Specs & Data Sheets
Specifications
-
Accessories
-
Additional information
Additional information
Weight 16 oz Dimensions 3 × 1 × 3.2 in Part Number 250T-TC1-DIN-NCR: 12 to 50V DC @ 20mA (loop-power) power, 350T-TC1-Y-DIN-NCR: DC-power; 4 to 20mA DC output, 450T-TC1-Y-1-DIN-NCR: AC-power; 4 to 20mA DC output; 115V AC power
Product Series FlatPack Series