Product short description:
  • Dual channels
  • RTD (Pt, Ni, Cu) or 0-4500 ohm input
  • 0-20mA, ±10V outputs
  • 6-32V DC local/bus power
RSS
FACEBOOK
FACEBOOK
TWITTER
Visit Us
LINKEDIN

DT330 series signal conditioners provide two independent I/O channels in a single, space-saving unit. The DT335 model is a four-wire dual transmitter that isolates and converts RTD or linear resistance sensor inputs to proportional control signals. Each channel supports DC current or voltage output. An optional DIN rail bus can deliver primary or redundant power to multiple units.

High-voltage isolation separates inputs, outputs, and power from each other. Isolation protects from surges, reduces noise, and eliminates ground loop errors.

Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software. The Android app enables setup with mobile devices.

Advanced signal processing capabilities, variable range input/output, and convenient USB programming make this instrument very versatile. These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.

Performance Specifications

IMPORTANT: To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends use of a USB isolator like Acromag’s USB-Isolator when configuring a DT330 Series transmitter.

USB Interface

USB Connection
Type: USB Mini-B type socket, 5-pin
Data Rate: 12Mbps. USB v1.1 and 2.0 compatible
Maximum cable length: 5.0 meters
Transient voltage suppression on power and data lines.

USB Driver:

Not required. Uses built-in Human Interface Device (HID) USB drivers of the Windows operating system.

Input (two channels)

Default Configuration
Input: 100Ω Pt RTD, 3-wire, =0.00385, -200 to 850°C, medium filter
Output: 4 to 20mA, upscale break detect

A/D Converters (ADC)
Two 24-bit Sigma Delta ADCs (only 16-bits used)

Input Ranges
Input Type                                   Range                    Accuracy
RTD, Pt 100Ω                          -200 to 850°C               ±0.25°C
RTD, Pt 200Ω                          -200 to 850°C               ±0.30°C
RTD, Pt 500Ω                         -200 to 850°C                ±0.50°C
RTD, Pt 1000Ω                       -200 to 850°C                ±1.00°C
Ni 120Ω (Minco 7-120)          -80 to 320°C                ±0.08°C
Cu 10Ω (Minco 16-9)           -200 to 270°C                 ±1.00°C
Linear Resistance                       0 to 25Ω                    ±0.05Ω
Linear Resistance                       0 to 450Ω                  ±0.10Ω
Linear Resistance                       0 to 9000Ω                ±0.90Ω
Linear Resistance                       0 to 2250Ω                ±2.25Ω
Linear Resistance                       0 to 4500Ω                ±4.50Ω

Ambient Temperature Effect: Better than ±80ppm/°C (±0.008%/°C)
Scaling Adjust: Full range
Lead Break (Sensor Burnout) Detection: Upscale/downscale full range
Input Over-Voltage Protection: Bipolar Transient Voltage Suppression (TVS) and diode clamping
Input Filter: RC filter plus variable digital filter (none, low, medium, high)
Input Bandwidth: -3dB @ 16Hz (no filtering)
Noise Rejection:
Common Mode: 106dB no filter
Normal Mode: 1dB no filter, 60Hz (>80dB med./high filter)

Output (two channels)

D/A Converters (DAC): Two 16-bit D/A converters
Output Ranges:
±10V (±11V maximum)
±5V (±5.5V maximum)
0 to 10V (11V maximum)
0 to 5V (5.5V maximum)
0 to 20mA (24mA maximum)
4 to 20mA (24mA maximum)
Output Accuracy: ±0.05%, typical. ±0.1%, maximum
Output Load:
Voltage output: 1K ohms minimum
Current output: 0-550 ohms
Output Compliance: 11V, typical

Output Response Time (for step input change)

Time to reach 98% of output value (typical)
No filtering               25 milliseconds
Low filter                  44 milliseconds
Medium filter        146 milliseconds
High filter             1068 milliseconds

Output Ripple: Less than ±0.1% of output span

Environmental

Operating temperature
Operation: -40 to 70°C (-40° to 158°F)
Storage: -40 to 85°C (-40 to 185°F)
Relative humidity: 5 to 95% non-condensing
Power Requirement: 6-32V DC SELV, 1.6W max
Isolation: 1500V AC peak. 250V AC (354V DC) continuous isolation between inputs, outputs, and power (5-way)
Shock and Vibration Immunity:
Vibration: 4g, per IEC 60068-2-6
Shock: 25g, per IEC 60068-2-27

Approvals (pending)
CE compliant. Designed for UL/cUL Class I Division 2 Groups ABCD, ATEX / IECEx Zone 2. II 3 G Ex nA IIC T4 Gc -40°C < Ta < +80°C

Electromagnetic Compatibility (EMC) Compliance
Radiated Emissions: BS EN 61000-6-4, CISPR 16
RFI: BS EN 61000-6-2, IEC 61000-4-3
Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6
ESD: BS EN 61000-6-2, IEC 61000-4-2
EFT: BS EN 61000-6-2, IEC 61000-4-4
Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5

Physical

General: General-purpose enclosure designed for mounting on 35mm “T-type” DIN rail
Case Material: Self-extinguishing polyamide, UL94 V-0 rated
I/O Connectors: Removable plug-in terminal blocks rated for 12A/250V; AWG #26-12, stranded or solid copper wire
Dimensions: 17.5 x 114.5 x 99.0 mm (0.7 x 4.51 x 3.90 inches)
Unit weight: 0.16 kg (0.35 pounds)
Shipping Weight: 0.22 kg (0.5 pounds) packed

  • Operate as a dual transmitter, a single transmitter, or a signal splitter
  • Easy configuration via USB with Windows software or Agility™ app for Android
  • Independently adjustable and scalable input and output ranges
  • Selectable RTD and linear resistance input types: Pt 100/200/500Ω, Ni 120Ω, Cu 10Ω, 0-4500Ω
  • Supports 2, 3, and 4-wire sensor connections
  • Selectable current and voltage output ranges: 0-20mA, 4-20mA, ±5V, ±10V, 0-5V, 0-10V DC
  • High accuracy, linearity, stability, and reliability
  • User-selectable filtering (none, low, med., high)
  • Selectable up/downscale break detection
  • Bus power, local power, or both (redundancy)
  • Space-saving 17.5mm (0.7 inch) unit with pluggable terminals for convenient wiring
  • 1500V input isolation, 5-way, (power/input/output)
  • Wide ambient operation (-40 to 70°C)
  • CE compliant. UL/cUL Class I Div 2, ATEX/IECEx Zone 2 approvals pending

Specifications

Manuals

DT335 User Manual (Log in to download the file)

DT230 and DT330 Configuration Software (Log in to download the file)
Agility Config Tool (Log in to download the file)
  • Compare

    TT Bus-Kit: DIN Rail Bus Power Connector

    • One kit supports multiple SP Series Splitters or DT and TT Series transmitters.
    $25
    Select options
  • Compare

    TTC-SIP: Software

    $160
    Select options
  • Compare

    USB Cables

    $15
    Select options
  • Compare

    USB Isolator

    • USB-powered, USB 2.0 and 1.1 compatible
    • 1500V AC / 2100V DC isolation
    • No drivers required
    $99
    Select options
  • Compare

    USB-to-Ethernet Adapter

    Simplifies configuration of Acromag Ethernet I/O Modules Prevents disruption of existing LANs This device is a USB-to-Ethernet adapter that you can use to communicate with any Acromag Ethernet I/O product for the purpose of setup and re-configuration for your application. It is recommended for initial communication with Acromag Ethernet devices so that you do not have to disrupt your existing network connection.
    $75
    Select options

Additional information

Weight N/A
Dimensions 12 × 13 × 3 in
Part Number

4001-096: USB Ethernet Adapter

  • Description

    Standards

    USB 1.0, 1.1, 2.0 IEEE 802.3, IEEE 802.3u

    Ports One Type-A Male Connector, One RJ-45 Port
    LEDs Link/Activity

    Cabling
    Type Cat 5 Ethernet Cable

    Dimensions
    7.96” x 1.00” x 0.69” (202.3 x 25.35 x 17.65 mm)

    Weight
    0.8 oz (23 kg)

    Power
    3.3V low power consumption

    Certification
    FCC Class B, CE Class B, UL

    Operating Temp.
    32 to 158°F (0 to 70°C)

    Storage Temp.
    32 to 158°F (0 to 70°C)

    Operating Humidity
    10 to 90% non-condensing

    Storage Humidity
    10 to 90% non-condensing

    Includes: Package Contents

    • One USB Ethernet Adapter
    • One Driver Installation CD
    • One Quick Installation Guide
    • One User Guide included on Installation CD
    • One Acromag Ethernet I/O Instruction Sheet
    • One IP Address Batch Configuration CD
  • Features & Benefits

    • Operate as a dual transmitter, a single transmitter, or a signal splitter
    • Easy configuration via USB with Windows software or Agility™ app for Android
    • Independently adjustable and scalable input and output ranges
    • Selectable RTD and linear resistance input types: Pt 100/200/500Ω, Ni 120Ω, Cu 10Ω, 0-4500Ω
    • Supports 2, 3, and 4-wire sensor connections
    • Selectable current and voltage output ranges: 0-20mA, 4-20mA, ±5V, ±10V, 0-5V, 0-10V DC
    • High accuracy, linearity, stability, and reliability
    • User-selectable filtering (none, low, med., high)
    • Selectable up/downscale break detection
    • Bus power, local power, or both (redundancy)
    • Space-saving 17.5mm (0.7 inch) unit with pluggable terminals for convenient wiring
    • 1500V input isolation, 5-way, (power/input/output)
    • Wide ambient operation (-40 to 70°C)
    • CE compliant. UL/cUL Class I Div 2, ATEX/IECEx Zone 2 approvals pending
  • Specs & Data Sheets

    Specifications

    Manuals

    DT335 User Manual (Log in to download the file)

  • Software

    DT230 and DT330 Configuration Software (Log in to download the file)
    Agility Config Tool (Log in to download the file)
  • Accessories

    • Compare

      TT Bus-Kit: DIN Rail Bus Power Connector

      • One kit supports multiple SP Series Splitters or DT and TT Series transmitters.
      $25
      Select options
    • Compare

      TTC-SIP: Software

      $160
      Select options
    • Compare

      USB Cables

      $15
      Select options
    • Compare

      USB Isolator

      • USB-powered, USB 2.0 and 1.1 compatible
      • 1500V AC / 2100V DC isolation
      • No drivers required
      $99
      Select options
    • Compare

      USB-to-Ethernet Adapter

      Simplifies configuration of Acromag Ethernet I/O Modules Prevents disruption of existing LANs This device is a USB-to-Ethernet adapter that you can use to communicate with any Acromag Ethernet I/O product for the purpose of setup and re-configuration for your application. It is recommended for initial communication with Acromag Ethernet devices so that you do not have to disrupt your existing network connection.
      $75
      Select options
  • Additional information

    Additional information

    Weight N/A
    Dimensions 12 × 13 × 3 in
    Part Number

    4001-096: USB Ethernet Adapter