Click to zoom
$255$460
Clear
Product short description:
  • TC (types J, K T, R, S, E, B, N), ±1V DC, selectable range/type input
  • 4 to 20mA DC output
  • 12-50V DC from output loop power
  • DIP-switch configuration, signal linearizer, push-button calibration
RSS
FACEBOOK
FACEBOOK
TWITTER
Visit Us
LINKEDIN

Models:
655T: Single TC/mV input channel
656T: Dual TC/mV input channel

These units accept universal thermocouple and millivolt input signals, provide isolation, and output proportional DC current signals. The output can also be linearized to the input sensor signal. Single-channel units are ideal for panel shops and end-users who require a high-density signal conditioner that can cover a broad range of temperature measurement applications.

Configuration is fast and easy. First, you select the input type with a simple DIP switch. Then, you set your zero/full-scale output values using a toggle switch on the front panel to increase or decrease the signal until you read the desired output value on your voltmeter. The toggles make it easy to calibrate a normal (proportional) or reverse-acting (inverse) response in seconds. After setting the desired calibration, just press the mode/set toggle and your configuration settings are safely saved to nonvolatile memory.

Both models provide high-voltage input isolation (output and power circuits share a common). On dual channel units, each channel operates independently, with inputs isolated from each other, to prevent interaction between channels.

Input Ranges:
TC types: J, K, T, R, S, E, B, N (DIP switch selection)
DC voltage: ±15.6mV to ±62.5mV, 0 to 1V DC

Output Ranges: 4 to 20mA DC

Power Requirement:
12 to 50V DC (loop-powered)
Two-wire transmitter

Approvals:
UL, cUL listed
Class I; Division 2; Groups A, B, C, D

Performance Specifications

General Input

Analog to Digital Converter (ADC): 16-bit S-D A/D converter
Noise Rejection
Normal Mode: Better than 40dB @ 60Hz
Common Mode: Better than 100dB @ 60Hz
Input Over-voltage Protection: Bipolar Transient Voltage Suppressors (TVS)

Thermocouple Input

Input Ranges (switch-selectable)
TC Type            Temperature Range                   Accuracy
J                    -210 to 760°C (-346 to 1400°F)           ±0.5°C
K                     200 to 1372°C (-328 to 2502°F)        ±0.5°C
T                    -260 to 400°C (-436 to 752°F)             ±0.5°C
R                      -50 to 1768°C (-58 to 3214°F)           ±1.0°C
S                      -50 to 1768°C (-58 to 3214°F)           ±1.0°C
E                    -200 to 1000°C (-328 to 1832°F)        ±0.5°C
B                     260 to 1820°C (500 to 3308°F)          ±1.0°C
N                   -230 to 1300°C (-382 to 2372°F)        ±0.5°C
Span adjust: Full range. 100°C or 3mV minimum span recommended.
Zero adjust: 0 to 90 % of full range.

Thermocouple Linearization: On/off selectable
Thermocouple Break Detection: TC sensor failure can be configured for either upscale or downscale.
Cold Junction Compensation (CJC) Control: On/off selectable

milliVolt Input

Input Range
Ranges: ±15.6, ±31.3, ±62.5mV
0 to 0.125, 0.25, 0.5, 1.0V DC
Span adjust: 10 to 100% of range
Zero adjust: 0 to 90% of range

Output

Output Range: Range: 4 to 20mA DC, 3.8 to 22mA range typical
Output Compliance: Rload = (Vsupply – 12V) / 0.02A
Output Response Control: Proportional/inverse selectable
Ambient Temperature Effect: Better than ±0.006% of input span per °C or ±100ppm/°C, whichever is greater
Output Response Time (for input step change): 700mS typical to 98% of final output value

Environmental

Ambient Temperature:
Operating: -25 to 75°C (-13 to 167°F)
Storage: -40 to 85°C (-40 to 185°F)
Relative Humidity: 5 to 95%, non-condensing
Power Requirement: 12 to 50V DC @ 25mA for each output channel
Isolation: Inputs, outputs, and individual channels are isolated from each other for common-mode voltages up to 250V AC, or 354V DC off ground, on a continuous basis (will withstand 1500V AC dielectric strength test for one minute without breakdown).
Radiated Field Immunity (RFI): Complies with EN61000-4-3 Level 3 and EN50082-1
Electromagnetic Field Immunity (EMI): Less than ±0.25% of output span effect
Electrical Fast Transient (EFT): Complies with EN61000-4-4 Level 3 and EN50082-1
Electrostatic Discharge (ESD): Complies with EN61000-4-2 Level 3 and EN50082-1
Radiated Emissions: Meets or exceeds EN50081-1 for Class B equipment
Approvals
UL & cUL listed
Hazardous Locations: Class I: Div. 2; Groups A, B, C, D

Physical

Enclosure: Case: Self-extinguishing NYLON type 6.6 polyamide thermoplastic UL94 V-2 NEMA Type 1 enclosure.
Connectors (Removable Terminal Blocks): Wire Range: AWG #12-24
Printed Circuit Boards: Military grade FR-4 epoxy glass circuit board
Dimensions:
1.05W x 4.68H x 4.35D inches
26.7W x 118.9H x 110.5D millimeters
Shipping Weight: 1 pound (0.45 Kg) packed

  • Selectable thermocouple input types offer flexibility to fit many applications.
  • DIP switch-configuration and self-ranging technologies speed installation without pots, jumpers, or software.
  • Linearizer function provides an output that is linear to the temperature or millivolt signal.
  • Isolation eliminates ground loops, reduces noise, and blocks transient signals.
  • Toggle-switch calibration simplifies field adjustments for faster and easier maintenance.
  • Configuration lockout safety feature prevents tampering and accidental changes.
  • Reverse-acting output capability enables inverse proportional control signals.
  • Dual channel model saves space and reduces equipment costs.
  • CJC control only requires a millivolt source to calibrate modules
  • High-resolution sigma-delta A/D converters deliver superior accuracy for reliable measurements.
  • Operating temperature range: -25 to 75°C (-13 to 167°F)

Specs & Catalogs

Manuals

655T, 656T User Manual (Log in to download the file)

  • Compare

    20RM-16-DIN: 19” rack-mount kit with DIN rail

    • 19" rack-mount kit with DIN rail
    $175
    Select options
  • Compare

    DIN Rail: Type T

    • DIN Rail Strip, Type T
    $10$20
    Read more
  • Compare

    PS5R: Slim Line Power Supplies

    • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
    • Universal Input (85-264V AC / 100-370V DC)
    • Lightweight and compact size
    $95$245
    Select options

Additional information

Weight 16 oz
Dimensions 12 × 13 × 3 in
Part Number

PS5R-VB05: 10W universal power supply; 5V DC, PS5R-VB12: 15W universal power supply; 12V DC, PS5R-VB24: 15W universal power supply; 24V DC, PS5R-VC12: 30W universal power supply; 12V DC, PS5R-VC24: 30W universal power supply; 24V DC, PS5R-VD24: 60W universal power supply; 24V DC, PS5R-VE24: 90W universal power supply; 24V DC, PS5R-VF24: 120W universal power supply; 24V DC, PS5R-VG24: 240W universal power supply; 24V DC

  • Description

    PS5R Slim Line models feature universal voltage inputs. Use them in tight spaces or save valuable DIN rail space while still filling your requirements for power. PS5R-Vs have spring-up screw terminals, fused inputs and overload protection. They are DIN Rail or direct surface mountable (6 directions) and have universal (85 – 264V AC) voltage inputs.

    Efficiency is the name of the game for PS5R-V. Improvements in operating efficiency and size lead to performance improvements. These improvements include expanded operating temperature range and a MTBF of up to 900,000 hours. Altogether, these improvements mean PS5R-V is an unmatched value.

    The PS5R-V series boasts numerous worldwide approvals and certifications, including UL 508. All models under 100W are UL1310 Class 2 approved. Specialized approvals include Class I Division 2 for use in hazardous locations as well as SEMI F47 for use in sensitive equipment applications.

    No derating means you save money, space and time. With nine models available, it’s easy to find the one that’s right for your application.

  • Features & Benefits

    • Selectable thermocouple input types offer flexibility to fit many applications.
    • DIP switch-configuration and self-ranging technologies speed installation without pots, jumpers, or software.
    • Linearizer function provides an output that is linear to the temperature or millivolt signal.
    • Isolation eliminates ground loops, reduces noise, and blocks transient signals.
    • Toggle-switch calibration simplifies field adjustments for faster and easier maintenance.
    • Configuration lockout safety feature prevents tampering and accidental changes.
    • Reverse-acting output capability enables inverse proportional control signals.
    • Dual channel model saves space and reduces equipment costs.
    • CJC control only requires a millivolt source to calibrate modules
    • High-resolution sigma-delta A/D converters deliver superior accuracy for reliable measurements.
    • Operating temperature range: -25 to 75°C (-13 to 167°F)
  • Specs & Data Sheets

    Specs & Catalogs

    Manuals

    655T, 656T User Manual (Log in to download the file)

  • Accessories

    • Compare

      20RM-16-DIN: 19” rack-mount kit with DIN rail

      • 19" rack-mount kit with DIN rail
      $175
      Select options
    • Compare

      DIN Rail: Type T

      • DIN Rail Strip, Type T
      $10$20
      Read more
    • Compare

      PS5R: Slim Line Power Supplies

      • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
      • Universal Input (85-264V AC / 100-370V DC)
      • Lightweight and compact size
      $95$245
      Select options
  • Additional information

    Additional information

    Weight 16 oz
    Dimensions 12 × 13 × 3 in
    Part Number

    PS5R-VB05: 10W universal power supply; 5V DC, PS5R-VB12: 15W universal power supply; 12V DC, PS5R-VB24: 15W universal power supply; 24V DC, PS5R-VC12: 30W universal power supply; 12V DC, PS5R-VC24: 30W universal power supply; 24V DC, PS5R-VD24: 60W universal power supply; 24V DC, PS5R-VE24: 90W universal power supply; 24V DC, PS5R-VF24: 120W universal power supply; 24V DC, PS5R-VG24: 240W universal power supply; 24V DC