DT236: Current / milliVolt Input Two-Wire Dual Transmitter
Product short description:
- Dual channels
- ±20mA, ±500mV inputs
- 4-20mA outputs (sink/source)
- 7-32V DC loop power
The DT236 model is a dual two-wire transmitter that isolates and converts DC current or low voltage inputs to proportional 4-20mA control signals. Power is received from the output loop current or a DC supply when using a three-wire connection.
Click here to watch a short video highlighting the features of the DT236.
- Description
- Features & Benefits
- Tech Papers
- Specs & Data Sheets
- Software
- Accessories
- Additional information
DT236: Current / milliVolt Input Two-Wire Dual Transmitter Description
DT230 series signal conditioners provide two independent I/O channels in a single, space-saving unit. The DT236 model is a dual two-wire transmitter that isolates and converts DC current or low voltage inputs to proportional 4-20mA control signals. Power is received from the output loop current or a DC supply when using a three-wire connection.
High-voltage isolation separates all input and output circuits from each other. Isolation protects from surges, reduces noise, and helps eliminate ground loop errors.
Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software. The Android app enables setup with mobile devices.
Advanced signal processing capabilities, variable range input/output, and convenient USB programming make this instrument very versatile. These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.
Performance Specifications
IMPORTANT: To prevent ground loop error between a grounded PC and a grounded input signal, Acromag strongly recommends use of a USB isolator like Acromag’s USB-Isolator when configuring a DT230 Series transmitter.
USB Interface
USB Connection
Type: USB Mini-B type socket, 5-pin
Data Rate: 12Mbps. USB v1.1 and 2.0 compatible
Maximum cable length: 5.0 meters
Transient voltage suppression on power and data lines.
Input (two channels)
Default Configuration/Calibration
Input: 4 to 20mA, medium filter
Output: 4 to 20mA
A/D Converters (ADC)
Two 24-bit Sigma Delta ADCs (only 16-bits used)
Input Ranges:
Path A: ±1mA, ±20mA, 0 to 11.17mA, 0-20mA, 4-20mA DC
Path B: ±0.5V, 0-500mV DC
Ambient Temperature Effect: Better than ±80ppm/°C (±0.008%/°C)
Scaling Adjust: Full range
Input Impedance:
Current input: 24.9 ohms
Voltage input: 15M ohms
Input Over-Voltage Protection: Bipolar Transient Voltage Suppression (TVS) and diode clamping
Input Filter: RC filter plus variable digital filter (none, low, medium, high)
Input Bandwidth: -3dB @ 16Hz (no filtering)
Noise Rejection (@ 60Hz, no filter):
Common Mode: 93dB no filter (139dB high filter)
Normal Mode: 6dB no filter (>80dB high filter)
Output (two channels)
D/A Converters (DAC): Two 16-bit D/A converters
Output Ranges: 4-20mA DC 3.5-24mA under/over-range capability
Output Accuracy: ±0.05%, typical. ±0.1%, maximum
Output Compliance:
Rload = (Vsupply – 7V) / 0.020A
Rload = 0 to 850 ohms @ 24V DC
Output Response Time (for step input change)
Time to reach 98% of output value (typical)
No filtering 31 milliseconds
Low filter 51 milliseconds
Medium filter 152 milliseconds
High filter 1100 milliseconds
Output Ripple: Less than ±0.1% of output span
Environmental
Operating Temperature
Operation: -40 to 80°C (-40° to 176°F)
Storage: -40 to 85°C (-40 to 185°F)
Relative humidity: 5 to 95% non-condensing
Power Requirement: Loop-powered, 7-32V DC SELV, 24mA max
Isolation: 1500V AC peak. 250V AC (354V DC) continuous isolation between input and output circuits
Shock and Vibration Immunity:
Vibration: 4g, per IEC 60068-2-6
Shock: 25g, per IEC 60068-2-27
Approvals
CE compliant. Designed for UL/cUL Class I Division 2 Groups ABCD, ATEX / IECEx Zone 2, II 3 G Ex nA IIC T4 Gc -40°C < Ta < +80°C
Electromagnetic Compatibility (EMC) Compliance
Radiated Emissions: BS EN 61000-6-4, CISPR 16
RFI: BS EN 61000-6-2, IEC 61000-4-3
Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6
ESD: BS EN 61000-6-2, IEC 61000-4-2
EFT: BS EN 61000-6-2, IEC 61000-4-4
Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5
Physical
General: General-purpose enclosure designed for mounting on 35mm “T-type” DIN rail
Case Material: Self-extinguishing polyamide, UL94 V-0 rated
I/O Connectors: Removable plug-in terminal blocks rated for 12A/250V; AWG #26-12, stranded or solid copper wire
Dimensions: 17.5 x 114.5 x 99.0 mm (0.7 x 4.51 x 3.90 inches)
Unit weight: 0.16 kg (0.35 pounds)
Shipping Weight: 0.22 kg (0.5 pounds) packed
- Operate as a dual transmitter, a single transmitter, or a signal splitter
- Easy configuration via USB with Windows software or Agility™ app for Android
- Independently adjustable and scalable: input and output ranges
- Selectable current and voltage input ranges: 0/4-20mA, ±1mA, ±20mA, ±0.5V, 0-500mV DC
- Compatible with Acromag 0-20A AC sensor input
- 4-20mA current loop outputs support sinking or sourcing circuit configurations
- User-configurable output range clamp levels support NAMUR-compliant operation
- Very low 7V two-wire loop burden
- High accuracy, linearity, stability, and reliability
- User-selectable filtering (none, low, med, high)
- Space-saving 17.5mm (0.7 inch) unit with pluggable terminals for convenient wiring
- 1500V isolation, 4-way (inputs/outputs)
- Wide ambient operation (-40 to 80°C)
- Approvals: CE compliant. UL/cUL Class I Div 2, ATEX/IECEx Zone 2
-
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
$50Select options -
USB Isolator
- USB-powered, USB 2.0 and 1.1 compatible
- 1500V AC / 2100V DC isolation
- No drivers required
$110Select options
Additional information
Weight | 16 oz |
---|---|
Dimensions | 13 × 12 × 3 in |
Part Number | DT236-0600: Isolated 4-20mA Loop-Powered Outputs |
Configuration | Agility Mobile App, Windows Software Configuration |
Product Series | DT230 Series |
-
Description
DT236: Current / milliVolt Input Two-Wire Dual Transmitter Description
DT230 series signal conditioners provide two independent I/O channels in a single, space-saving unit. The DT236 model is a dual two-wire transmitter that isolates and converts DC current or low voltage inputs to proportional 4-20mA control signals. Power is received from the output loop current or a DC supply when using a three-wire connection.
High-voltage isolation separates all input and output circuits from each other. Isolation protects from surges, reduces noise, and helps eliminate ground loop errors.
Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software. The Android app enables setup with mobile devices.
Advanced signal processing capabilities, variable range input/output, and convenient USB programming make this instrument very versatile. These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.
Performance Specifications
IMPORTANT: To prevent ground loop error between a grounded PC and a grounded input signal, Acromag strongly recommends use of a USB isolator like Acromag’s USB-Isolator when configuring a DT230 Series transmitter.
USB Interface
USB Connection
Type: USB Mini-B type socket, 5-pin
Data Rate: 12Mbps. USB v1.1 and 2.0 compatible
Maximum cable length: 5.0 meters
Transient voltage suppression on power and data lines.Input (two channels)
Default Configuration/Calibration
Input: 4 to 20mA, medium filter
Output: 4 to 20mAA/D Converters (ADC)
Two 24-bit Sigma Delta ADCs (only 16-bits used)Input Ranges:
Path A: ±1mA, ±20mA, 0 to 11.17mA, 0-20mA, 4-20mA DC
Path B: ±0.5V, 0-500mV DC
Ambient Temperature Effect: Better than ±80ppm/°C (±0.008%/°C)
Scaling Adjust: Full range
Input Impedance:
Current input: 24.9 ohms
Voltage input: 15M ohms
Input Over-Voltage Protection: Bipolar Transient Voltage Suppression (TVS) and diode clamping
Input Filter: RC filter plus variable digital filter (none, low, medium, high)
Input Bandwidth: -3dB @ 16Hz (no filtering)
Noise Rejection (@ 60Hz, no filter):
Common Mode: 93dB no filter (139dB high filter)
Normal Mode: 6dB no filter (>80dB high filter)Output (two channels)
D/A Converters (DAC): Two 16-bit D/A converters
Output Ranges: 4-20mA DC 3.5-24mA under/over-range capability
Output Accuracy: ±0.05%, typical. ±0.1%, maximum
Output Compliance:
Rload = (Vsupply – 7V) / 0.020A
Rload = 0 to 850 ohms @ 24V DCOutput Response Time (for step input change)
Time to reach 98% of output value (typical)
No filtering 31 milliseconds
Low filter 51 milliseconds
Medium filter 152 milliseconds
High filter 1100 milliseconds
Output Ripple: Less than ±0.1% of output span
Environmental
Operating Temperature
Operation: -40 to 80°C (-40° to 176°F)
Storage: -40 to 85°C (-40 to 185°F)
Relative humidity: 5 to 95% non-condensing
Power Requirement: Loop-powered, 7-32V DC SELV, 24mA max
Isolation: 1500V AC peak. 250V AC (354V DC) continuous isolation between input and output circuits
Shock and Vibration Immunity:
Vibration: 4g, per IEC 60068-2-6
Shock: 25g, per IEC 60068-2-27Approvals
CE compliant. Designed for UL/cUL Class I Division 2 Groups ABCD, ATEX / IECEx Zone 2, II 3 G Ex nA IIC T4 Gc -40°C < Ta < +80°CElectromagnetic Compatibility (EMC) Compliance
Radiated Emissions: BS EN 61000-6-4, CISPR 16
RFI: BS EN 61000-6-2, IEC 61000-4-3
Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6
ESD: BS EN 61000-6-2, IEC 61000-4-2
EFT: BS EN 61000-6-2, IEC 61000-4-4
Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5Physical
General: General-purpose enclosure designed for mounting on 35mm “T-type” DIN rail
Case Material: Self-extinguishing polyamide, UL94 V-0 rated
I/O Connectors: Removable plug-in terminal blocks rated for 12A/250V; AWG #26-12, stranded or solid copper wire
Dimensions: 17.5 x 114.5 x 99.0 mm (0.7 x 4.51 x 3.90 inches)
Unit weight: 0.16 kg (0.35 pounds)
Shipping Weight: 0.22 kg (0.5 pounds) packed -
Features & Benefits
- Operate as a dual transmitter, a single transmitter, or a signal splitter
- Easy configuration via USB with Windows software or Agility™ app for Android
- Independently adjustable and scalable: input and output ranges
- Selectable current and voltage input ranges: 0/4-20mA, ±1mA, ±20mA, ±0.5V, 0-500mV DC
- Compatible with Acromag 0-20A AC sensor input
- 4-20mA current loop outputs support sinking or sourcing circuit configurations
- User-configurable output range clamp levels support NAMUR-compliant operation
- Very low 7V two-wire loop burden
- High accuracy, linearity, stability, and reliability
- User-selectable filtering (none, low, med, high)
- Space-saving 17.5mm (0.7 inch) unit with pluggable terminals for convenient wiring
- 1500V isolation, 4-way (inputs/outputs)
- Wide ambient operation (-40 to 80°C)
- Approvals: CE compliant. UL/cUL Class I Div 2, ATEX/IECEx Zone 2
-
Tech Papers
How to Wire a 2 or 4-Wire Current Input Module Application NoteApplication Note: Current Input Wiring: 2-Wire & 4-Wire TT236 / SP236 / DT236 2/3-Wire Transmitters & Splitters TT336 / SP336 / DT336 4-Wire Transmitters & Splitters Featured Products: DT236: Current / milliVolt Input Two-Wire Dual Transmitter DT336: Current / Voltage Input Four-Wire Dual Transmitter SP236: Two-Wire Current / milliVolt Input Signal Splitter SP336: Four-Wire Current... -
Specs & Data Sheets
-
Software
-
Accessories
-
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
$50Select options -
USB Isolator
- USB-powered, USB 2.0 and 1.1 compatible
- 1500V AC / 2100V DC isolation
- No drivers required
$110Select options
-
Additional information
Additional information
Weight 16 oz Dimensions 13 × 12 × 3 in Part Number DT236-0600: Isolated 4-20mA Loop-Powered Outputs
Configuration Agility Mobile App, Windows Software Configuration
Product Series DT230 Series
Please login to submit this form.