Click to zoom
$390$540

Please sign in or register to see model options and to add products to your cart.

Product short description:
  • ±100V or 0 to 22mA DC input ranges (AC current with optional sensor)
  • 0 to 20mA DC, 0 to 10V DC output
  • Mechanical relay alarm (25V @ 5A)
  • 10-36V DC power
  • Software configured, performs linearization, square root extraction, and optional limit alarm functions
[DISPLAY_ULTIMATE_PLUS]

These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.

Each unit offers a selection of input and output ranges, as well as several signal conditioning options. This flexibility enables a single IntelliPack to handle a broad range of applications. As your needs change, you can easily reconfigure the unit for different ranges or functions.

Setup is very easy. IntelliPack modules are quickly configured with the user-friendly Windows software program. Field adjustments are simple with the module’s front-panel push-buttons and status LEDs. Once configured, IntelliPacks operate independent of any host computer.

Performance

General Input

Analog to Digital Converter (ADC): 16-bit Σ-Δ A/D converter
Ambient Temperature Effect: Better than ±0.005% of input span per °C or ±1μV, whichever is greater.
Noise Rejection:
Normal Mode: Better than 40dB @ 60Hz
Common Mode: Better than 100dB @ 60Hz
Input Response Time (for input step change): Less than 100mS typical to 98% of final output value
Input Over-voltage Protection: Bipolar Transient Voltage Suppressors (TVS)

DC Current Input

DC Current Input Ranges (100% rangeable):
Input Ranges          Resolution

0 to 22mA DC                  757nA
0 to 5mA DC                    189nA

DC Current Input Impedance: 24.9 ohms
Excitation Supply (for 2-wire instruments): +15V DC, 24mA maximum
DC Current Input Accuracy: better than ±0.05% of input span

DC Voltage Input

DC Voltage Input Ranges (100% rangeable):
Input Ranges          Resolution

±100V DC                       3.77mV
±50V DC                         1.88mV
±25V DC                           942μV
±12V DC                            471μV
±6V DC                             236μV
±3V DC                              118μV

Input impedance: Greater than 500K ohms
DC Voltage Input Accuracy: better than ±0.05% of input span

AC Current Input

AC Current Input Range (optional): An optional external AC current sensor is required to monitor AC current signals (Model 5020-350).
AC Current Range          Primary Turns

0 to 20A AC                                       1
0 to 10A AC                                       2
0 to 5A AC                                         4
0 to 2A AC                                       10
0 to 1A AC                                       20
AC Current Input Accuracy: better than ±0.05% of input span

Output (DC V/mA)

D/A Converter: 16-bit Σ-Δ
Current Output:
0-1mA, 0-20mA, 4-20mA
Compliance: 10V minimum (500 ohm load)
Accuracy: 0.025% of span
Voltage Output:
Ranges: 0-5V, 0-10V
Compliance: 10mA maximum with short circuit protection. 1 ohm output impedance
Accuracy: 0.025% of span
Accuracy (overall input to output): 0.075% of span

Output (Relay)

Relay: One SPDT electro-mechanical relay
Relay Ratings (CSA ratings):
25V DC @ 5A
120/240V AC @ 5A
Relay Time Delay: Adjustable alarm delay of up to 25 seconds
Contact Material: Silver-cadmium oxide (AgCdO)
Expected Mechanical Life: 20 million operations

Environmental

Ambient Temperature:
Operating: -25 to 70°C (-13 to 158°F)
Storage: -40 to 85°C (-40 to 185°F)
Relative Humidity: 5 to 95%
Power Requirements: 10 to 36V DC. 110mA @ 24V. 170mA @ 15V
Isolation (optical):
4-way (input/output/relay/power)
1500V AC for 60 seconds or 250V AC continuous
Radiated Field Immunity (RFI): EN61000-4-3, EN50082-1
Electromagnetic Field Immunity (EMI):
Less than ±0.25% of output span effect under the influence of electromagnetic fields from switching solenoids, commutator motors, and drill motors.
Electrical Fast Transient (EFT): EN61000-4-4, EN50082-1
Surge Withstanding Capability (SWC): EN61000-4-5, EN50082-1
Electrostatic Discharge (ESD): EN61000-4-2, EN50082-1
Radiated Emissions: EN50081-1 for Class B equipment
Approvals: UL listed (USA, Canada)

Configuration

Software Configuration: Units are fully programmable via the Windows 7 or newer IntelliPack Configuration Program. Configuration downloads from PC through EIA232 serial port using Acromag 800C-SIP kit.
Field Configuration: Output, zero/full-scale, relay setpoint and deadband are configurable via push-buttons and a standard calibrator.
LED Indicators: LEDs indicate power, status, calibration, and alarm.

Physical

Enclosure: Case: Self-extinguishing NYLON type 6.6 polyamide thermoplastic UL94 V-2, color beige; general purpose NEMA Type 1 enclosure.
Connectors (Removable terminal blocks): Wire Range: AWG #14-22 (AWG #12 stranded only)
Printed Circuit Boards: Military grade FR-4 epoxy glass circuit board
Dimensions
1.05W x 4.68H x 4.35D inches
26.7W x 118.9H x 110.5D millimeters
Shipping Weight: 1 pound (0.45 Kg) packed

  • High-resolution Sigma-Delta A/D converter delivers high accuracy with low noise
  • Advanced micro-controller provides intelligent signal processing power for linearization,averaging, and square root computations
  • Windows 7 or newer software configuration speeds setup and replacement
  • Multi-purpose inputs and outputs reduce spare stock requirements
  • Relay output option provides local limit alarm capability
How to have a Flow Sensor with a Non-Linear Reversed Output Application Note
Problem: Have a flow sensor with a non-linear reversed output. Create a 4-20mA output proportional to flow rate. Solution: Model: 811T-0500 DC to DC Isolated Transmitter Model: 800C-SIP Software Interface Package Optional: PS5R-D24 Power Supply The 811T offers a 25 break-point table for sensor linearization. Input percentage is based on sensor V DC output. Output...

Manuals

811T User Manual (Log in to download the file)

IntelliPack Transmitter Configuration Software User Manual Model 5030-881 (Log in to download the file)

IntelliPack Configuration Software 5030-881 (Log in to download the file)
  • Compare

    20RM-16-DIN: 19” rack-mount kit with DIN rail

    • 19" rack-mount kit with DIN rail
    $190
    Select options
  • Compare

    4001-095: USB-to-Serial Adapter

    • USB-to-serial adapter
    • Easy to use to setup and re-configure modules
    $45
    Select options
  • Compare

    5020-350: Toroidal AC Current Sensor

    • AC Current Sensor to precondition an AC current input signal
    • Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
    $50
    Select options
  • Compare

    5030 Cable Series

    • Various specialty cables
    $25$100
    Select options
  • Compare

    5030-881

    • IntelliPack 800 Series software on CD-ROM
    $65
    Select options
  • Compare

    800C-SIP: IntelliPack Configuration Software

    • Configuration Software
    • USB-to-RS232 Adapter
    • RS232-to-RJ11 Adapter
    • Interface Cable
         
    $310
    Select options
  • Compare

    PS5R: Slim Line Power Supplies

    • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
    • Universal Input (85-264V AC / 100-370V DC)
    • Lightweight and compact size
    $100$255
    Select options
  • Compare

    Terminal Block Replacements

    • Simplifies wiring connections on Acromag I/O Modules
    • Barrier strip or spring clamp terminal block kits
    • Provide safe and secure wiring connections
    $35$45
    Select options

Additional information

Weight 11 oz
Dimensions 5 × 1.25 × 4.5 in
Part Number

811T-0500: Transmitter, 811T-0500-C: Transmitter with factory configuration, 811T-1500: Transmitter, limit alarm with relay, 811T-1500-C: Transmitter, limit alarm with relay, with factory configuration.

Configuration

Windows Software Configuration

Product Series

IntelliPack 800 Series

Power

DC Power, External Power

  • Description

    These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.

    Each unit offers a selection of input and output ranges, as well as several signal conditioning options. This flexibility enables a single IntelliPack to handle a broad range of applications. As your needs change, you can easily reconfigure the unit for different ranges or functions.

    Setup is very easy. IntelliPack modules are quickly configured with the user-friendly Windows software program. Field adjustments are simple with the module’s front-panel push-buttons and status LEDs. Once configured, IntelliPacks operate independent of any host computer.

    Performance

    General Input

    Analog to Digital Converter (ADC): 16-bit Σ-Δ A/D converter
    Ambient Temperature Effect: Better than ±0.005% of input span per °C or ±1μV, whichever is greater.
    Noise Rejection:
    Normal Mode: Better than 40dB @ 60Hz
    Common Mode: Better than 100dB @ 60Hz
    Input Response Time (for input step change): Less than 100mS typical to 98% of final output value
    Input Over-voltage Protection: Bipolar Transient Voltage Suppressors (TVS)

    DC Current Input

    DC Current Input Ranges (100% rangeable):
    Input Ranges          Resolution

    0 to 22mA DC                  757nA
    0 to 5mA DC                    189nA

    DC Current Input Impedance: 24.9 ohms
    Excitation Supply (for 2-wire instruments): +15V DC, 24mA maximum
    DC Current Input Accuracy: better than ±0.05% of input span

    DC Voltage Input

    DC Voltage Input Ranges (100% rangeable):
    Input Ranges          Resolution

    ±100V DC                       3.77mV
    ±50V DC                         1.88mV
    ±25V DC                           942μV
    ±12V DC                            471μV
    ±6V DC                             236μV
    ±3V DC                              118μV

    Input impedance: Greater than 500K ohms
    DC Voltage Input Accuracy: better than ±0.05% of input span

    AC Current Input

    AC Current Input Range (optional): An optional external AC current sensor is required to monitor AC current signals (Model 5020-350).
    AC Current Range          Primary Turns

    0 to 20A AC                                       1
    0 to 10A AC                                       2
    0 to 5A AC                                         4
    0 to 2A AC                                       10
    0 to 1A AC                                       20
    AC Current Input Accuracy: better than ±0.05% of input span

    Output (DC V/mA)

    D/A Converter: 16-bit Σ-Δ
    Current Output:
    0-1mA, 0-20mA, 4-20mA
    Compliance: 10V minimum (500 ohm load)
    Accuracy: 0.025% of span
    Voltage Output:
    Ranges: 0-5V, 0-10V
    Compliance: 10mA maximum with short circuit protection. 1 ohm output impedance
    Accuracy: 0.025% of span
    Accuracy (overall input to output): 0.075% of span

    Output (Relay)

    Relay: One SPDT electro-mechanical relay
    Relay Ratings (CSA ratings):
    25V DC @ 5A
    120/240V AC @ 5A
    Relay Time Delay: Adjustable alarm delay of up to 25 seconds
    Contact Material: Silver-cadmium oxide (AgCdO)
    Expected Mechanical Life: 20 million operations

    Environmental

    Ambient Temperature:
    Operating: -25 to 70°C (-13 to 158°F)
    Storage: -40 to 85°C (-40 to 185°F)
    Relative Humidity: 5 to 95%
    Power Requirements: 10 to 36V DC. 110mA @ 24V. 170mA @ 15V
    Isolation (optical):
    4-way (input/output/relay/power)
    1500V AC for 60 seconds or 250V AC continuous
    Radiated Field Immunity (RFI): EN61000-4-3, EN50082-1
    Electromagnetic Field Immunity (EMI):
    Less than ±0.25% of output span effect under the influence of electromagnetic fields from switching solenoids, commutator motors, and drill motors.
    Electrical Fast Transient (EFT): EN61000-4-4, EN50082-1
    Surge Withstanding Capability (SWC): EN61000-4-5, EN50082-1
    Electrostatic Discharge (ESD): EN61000-4-2, EN50082-1
    Radiated Emissions: EN50081-1 for Class B equipment
    Approvals: UL listed (USA, Canada)

    Configuration

    Software Configuration: Units are fully programmable via the Windows 7 or newer IntelliPack Configuration Program. Configuration downloads from PC through EIA232 serial port using Acromag 800C-SIP kit.
    Field Configuration: Output, zero/full-scale, relay setpoint and deadband are configurable via push-buttons and a standard calibrator.
    LED Indicators: LEDs indicate power, status, calibration, and alarm.

    Physical

    Enclosure: Case: Self-extinguishing NYLON type 6.6 polyamide thermoplastic UL94 V-2, color beige; general purpose NEMA Type 1 enclosure.
    Connectors (Removable terminal blocks): Wire Range: AWG #14-22 (AWG #12 stranded only)
    Printed Circuit Boards: Military grade FR-4 epoxy glass circuit board
    Dimensions
    1.05W x 4.68H x 4.35D inches
    26.7W x 118.9H x 110.5D millimeters
    Shipping Weight: 1 pound (0.45 Kg) packed

  • Features & Benefits

    • High-resolution Sigma-Delta A/D converter delivers high accuracy with low noise
    • Advanced micro-controller provides intelligent signal processing power for linearization,averaging, and square root computations
    • Windows 7 or newer software configuration speeds setup and replacement
    • Multi-purpose inputs and outputs reduce spare stock requirements
    • Relay output option provides local limit alarm capability
  • Tech Papers

    How to have a Flow Sensor with a Non-Linear Reversed Output Application Note
    Problem: Have a flow sensor with a non-linear reversed output. Create a 4-20mA output proportional to flow rate. Solution: Model: 811T-0500 DC to DC Isolated Transmitter Model: 800C-SIP Software Interface Package Optional: PS5R-D24 Power Supply The 811T offers a 25 break-point table for sensor linearization. Input percentage is based on sensor V DC output. Output...
  • Specs & Data Sheets

    Manuals

    811T User Manual (Log in to download the file)

    IntelliPack Transmitter Configuration Software User Manual Model 5030-881 (Log in to download the file)

  • Software

    IntelliPack Configuration Software 5030-881 (Log in to download the file)
  • Accessories

    • Compare

      20RM-16-DIN: 19” rack-mount kit with DIN rail

      • 19" rack-mount kit with DIN rail
      $190
      Select options
    • Compare

      4001-095: USB-to-Serial Adapter

      • USB-to-serial adapter
      • Easy to use to setup and re-configure modules
      $45
      Select options
    • Compare

      5020-350: Toroidal AC Current Sensor

      • AC Current Sensor to precondition an AC current input signal
      • Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
      $50
      Select options
    • Compare

      5030 Cable Series

      • Various specialty cables
      $25$100
      Select options
    • Compare

      5030-881

      • IntelliPack 800 Series software on CD-ROM
      $65
      Select options
    • Compare

      800C-SIP: IntelliPack Configuration Software

      • Configuration Software
      • USB-to-RS232 Adapter
      • RS232-to-RJ11 Adapter
      • Interface Cable
           
      $310
      Select options
    • Compare

      PS5R: Slim Line Power Supplies

      • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
      • Universal Input (85-264V AC / 100-370V DC)
      • Lightweight and compact size
      $100$255
      Select options
    • Compare

      Terminal Block Replacements

      • Simplifies wiring connections on Acromag I/O Modules
      • Barrier strip or spring clamp terminal block kits
      • Provide safe and secure wiring connections
      $35$45
      Select options
  • Additional information

    Additional information

    Weight 11 oz
    Dimensions 5 × 1.25 × 4.5 in
    Part Number

    811T-0500: Transmitter, 811T-0500-C: Transmitter with factory configuration, 811T-1500: Transmitter, limit alarm with relay, 811T-1500-C: Transmitter, limit alarm with relay, with factory configuration.

    Configuration

    Windows Software Configuration

    Product Series

    IntelliPack 800 Series

    Power