Click to zoom
$260$450
Clear
Product short description:
  • ±100V DC, 0 to 100mA DC, 0 to 20A AC (with optional sensor) input
  • 0 to 20mA, 0 to 10V DC output
  • 10-36V DC power
  • Universal DC I/O transmitters with auto-configuration and self-ranging capabilities
RSS
FACEBOOK
FACEBOOK
TWITTER
Visit Us
LINKEDIN

Models:
611T: Single I/O channel
612T: Dual I/O channel

These units receive DC current or voltage input signals, provide isolation, and output proportional DC current or voltage signals. With support for universal DC I/O ranges, 610T series transmitters provide a solution for a wide variety of isolation and signal conversion tasks. The single-channel 611T and dual-channel 612T are ideal for panel shops and end-users who require a high-density signal conditioner that can accommodate a broad range of instrumentation applications.

Installation is fast and simple with Acromag’s built-in auto-configuration feature. Using your standard calibrator, the 610T’s internal microcontroller automatically senses the input source type (voltage or current) and selects the optimum performance range for your zero and full-scale input values. To adjust your output values, simply push the up or down buttons on the front panel until you read the desired output signal on your meter.

Both models provide high-voltage isolation between the input, output and power (3-way). On dual channel units, each channel operates independently, with inputs isolated from each other, to prevent interaction between channels.

For easy troubleshooting, each channel has diagnostic LEDs to identify input over/under range conditions. An additional status LED indicates the unit is operating properly or that the front panel push button lockout feature has been invoked.

Input Ranges
Universal input with automatic configuration
±100mA (self-ranging)
±100V DC (self-ranging)
0 to 20 amps AC (with optional sensor)

Output Ranges
Universal output (user-configured ranges)
0 to 20mA (full range capability),
0 to 10V DC (full range capability)

Power Requirement: 10 to 36V DC
Approvals: CE marked. UL, cUL listed.

Performance Specifications

General Input

Analog to Digital Converter (ADC): 16-bit S-D A/D converter.
Noise Rejection:
Normal Mode: Better than 40dB @ 60Hz.
Common Mode: Better than 100dB @ 60Hz.
Input Overvoltage Protection: Bipolar Transient Voltage Suppressors (TVS)

DC Current Input

DC Current Input Range:
±100mA DC with full range capability.
Minimum recommended span is ±4mA.
DC Current Input Impedance: 10 ohms
DC Current Input Accuracy: Better than ±0.1% of output span.

DC Voltage Input

DC Voltage Input Range:
±100V DC with full range capability.
Minimum recommended span is ±40mV.
Input impedance:
±1V to ±100V input: greater than 100K ohms.
±40mV to ±1V input: 1K ohm
DC Voltage Input Accuracy: Better than ±0.1% of output span.

AC Current Input

AC Current Input Range (optional):
An optional external AC current sensor is required to monitor AC current signals (Model 5020-350).
AC Current Range       Primary Turns
0 to 20A AC                                      1
0 to 10A AC                                      2
0 to 5A AC                                        4
0 to 2A AC                                      10
0 to 1A AC                                      20

AC Current Input Accuracy: Better than ±0.5% of output span.

Output (DC V/mA)

Current Output:
Range: 0 to 20mA maximum (user-configured range).
Compliance: 11V DC typical.
Load resistance range: 0 to 550 ohms.
Voltage Output:
Ranges: 0 to 10V maximum (user-configured range).
Compliance: 10mA max. with short circuit protection. Output impedance: 1 ohms.
Accuracy (overall input to output): Better than ±0.1% of span for nominal output ranges of 0 to 10V or 0 to 20mA.
Ambient Temperature Effect: Better than ±0.018% of output span per °C or ±1µV, whichever is greater.
Output Response Time (for input step change): 800mS typical to 98% of final output value.

Environmental

Ambient Temperature
Operating: -25 to 70°C (-13 to 158°F).
Storage: -40 to 85°C (-40 to 185°F).
Relative Humidity: 5 to 95%, non-condensing.
Power Requirements
611T: 10 to 36V DC. 24V DC @ 55mA.
612T: 10 to 36V DC. 24V DC @ 75mA.
Isolation: 3-way (input/output/power). 1500V AC for 60 seconds or 250V AC continuous. Dual channel model includes input-to-input isolation and outputs share a common.
Radiated Field Immunity (RFI): Complies with EN61000-4-3 Level 3 and EN50082-1
Electromagnetic Field Immunity (EMI): Less than ±0.25% of output span effect
Electrical Fast Transient (EFT): Complies with EN61000-4-4 Level 3 and EN50082-1
Surge Withstanding Capability (SWC): Complies with EN61000-4-5 Level 3 and EN50082-1
Electrostatic Discharge (ESD): Complies with EN61000-4-2 Level 3 and EN50082-1
Radiated Emissions: Meets or exceeds EN50081-1 for Class B equipment.
Approvals:
CE marked, UL, cUL listed (USA, Canada).
UL3121 general product safety.

Physical

Enclosure: Case: Self-extinguishing NYLON type 6.6 polyamide thermoplastic UL94 V-2 NEMA Type 1 enclosure.
Connectors (Removable Terminal Blocks): Wire Range: AWG #12-24
Printed Circuit Boards: Military grade FR-4 epoxy glass circuit board.
Dimensions:
1.05W x 4.68H x 4.35D inches
26.7W x 118.9H x 110.5D millimeters
Shipping Weight: 1 pound (0.45 Kg) packed.

 

  • Universal DC input and output ranges offer flexibility to fit many applications
  • Auto-configuration and self-ranging technologies speed installation without pots, switches, jumpers, or software
  • Optical isolation eliminates ground loops, reduces noise, and blocks transient signals
  • Push-button calibration simplifies field adjustments for faster and easier maintenance
  • Configuration lockout safety feature prevents tampering and accidental changes
  • Reverse-acting output capability enables inverse proportional control signals
  • Each input channel can drive two outputs (a voltage and a current output signal)
  • Dual channel model saves space and reduces equipment costs
  • High-resolution sigma-delta A/D converters deliver superior accuracy for reliable measurements.
  • Operating temperature range: -25 to 70°C (-13 to 158°F)

Specs & Catalogs

Manuals

611T, 612T User Manual (Log in to download the file)

  • Compare

    20RM-16-DIN: 19” rack-mount kit with DIN rail

    • 19" rack-mount kit with DIN rail
    $175
    Select options
  • Compare

    5020-350: Toroidal AC Current Sensor

    • AC Current Sensor to precondition an AC current input signal
    • Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
    $45
    Select options
  • Compare

    5035 Series: Ethernet Cables

    • Ethernet straight cable, CAT5
    • Ethernet crossover cable, CAT5E
    • Low EMI Double-Shielded Ethernet Patch Cable
    $35$110
    Read more
  • Compare

    DIN Rail: Type T

    • DIN Rail Strip, Type T
    $10$20
    Read more
  • Compare

    PS5R: Slim Line Power Supplies

    • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
    • Universal Input (85-264V AC / 100-370V DC)
    • Lightweight and compact size
    $95$245
    Select options
  • Compare

    Terminal Block Replacements

    • Simplifies wiring connections on Acromag I/O Modules
    • Barrier strip or spring clamp terminal block kits
    • Provide safe and secure wiring connections
    $25$35
    Select options

Additional information

Weight 8 oz
Dimensions 12 × 13 × 3 in
Part Number

TBK-B01: two 6-position barrier strip style, TBK-B02: four 6-position barrier strip style, TBK-B03: one 3-position and three 6-position barrier strip style, TBK-S01: two 6-position spring clamp style, TBK-S02: four 6-position spring clamp style, TBK-S03: one 3-position and three 6-position spring clamp style

  • Description

    These optional terminal blocks provide safe and secure wiring connections. Large captive screw terminals or spring clamps enable fast, easy connections. Pluggable terminals are removable for simple disconnection of the module without disturbing the wiring.

    Optional terminal blocks are compatible with Acromag’s “white box” modules including BusWorks 900 Series, IntelliPack 800 Series, and isolated transmitters 600 Series.

    Barrier Strip Terminal Blocks

    Wire Range: 12-26 AWG
    Safety Ratings: UL, CSA, CE, TUV.
    Current/Voltage Rating: 15A, 300V.
    Pin Spacing: 5.08mm (0.2”).
    Housing Material: PPO, UL 94 V-0, Black.
    Contacts: Tin-Lead Plated Phosphor Bronze.
    Screw: M3, Nickel Plated Steel.
    Insulation Resistance: ≥105 Megohms.
    Dielectric Withstand: <3000V.

    Spring Clamp Terminal Blocks

    Wire Range: 12-28 AWG.
    Safety Ratings: UL, CSA, CE, TUV.
    Current/Voltage Rating: 15A, 300V.
    Pin Spacing: 5.08mm (0.2”)
    Housing Material: PPO, UL 94 V-0, Black.
    Contacts: Tin-Lead Plated Phosphor Bronze.
    Spring Clamp: Stainless Steel.
    Insulation Resistance: ≥105 Megohms.
    Dielectric Withstand: <3000V.

    Acromag Standard Cage Clamp Terminal Blocks

    Wire Range: 12-24 AWG.
    Current/Voltage Rating: 12A, 300V (UL).
    Pin Spacing: 5.08mm (0.2”).
    Housing Material: UL 94 V-0.
    Terminal: Brass, nickel plated.
    Wire Protector with Contact: Copper alloy tin plating.
    Screw: M3, steel, nickel over copper plating.
    Contact Resistance: ≤10 milliohms per circuit.

  • Features & Benefits

    • Universal DC input and output ranges offer flexibility to fit many applications
    • Auto-configuration and self-ranging technologies speed installation without pots, switches, jumpers, or software
    • Optical isolation eliminates ground loops, reduces noise, and blocks transient signals
    • Push-button calibration simplifies field adjustments for faster and easier maintenance
    • Configuration lockout safety feature prevents tampering and accidental changes
    • Reverse-acting output capability enables inverse proportional control signals
    • Each input channel can drive two outputs (a voltage and a current output signal)
    • Dual channel model saves space and reduces equipment costs
    • High-resolution sigma-delta A/D converters deliver superior accuracy for reliable measurements.
    • Operating temperature range: -25 to 70°C (-13 to 158°F)
  • Specs & Data Sheets

    Specs & Catalogs

    Manuals

    611T, 612T User Manual (Log in to download the file)

  • Accessories

    • Compare

      20RM-16-DIN: 19” rack-mount kit with DIN rail

      • 19" rack-mount kit with DIN rail
      $175
      Select options
    • Compare

      5020-350: Toroidal AC Current Sensor

      • AC Current Sensor to precondition an AC current input signal
      • Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
      $45
      Select options
    • Compare

      5035 Series: Ethernet Cables

      • Ethernet straight cable, CAT5
      • Ethernet crossover cable, CAT5E
      • Low EMI Double-Shielded Ethernet Patch Cable
      $35$110
      Read more
    • Compare

      DIN Rail: Type T

      • DIN Rail Strip, Type T
      $10$20
      Read more
    • Compare

      PS5R: Slim Line Power Supplies

      • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
      • Universal Input (85-264V AC / 100-370V DC)
      • Lightweight and compact size
      $95$245
      Select options
    • Compare

      Terminal Block Replacements

      • Simplifies wiring connections on Acromag I/O Modules
      • Barrier strip or spring clamp terminal block kits
      • Provide safe and secure wiring connections
      $25$35
      Select options
  • Additional information

    Additional information

    Weight 8 oz
    Dimensions 12 × 13 × 3 in
    Part Number

    TBK-B01: two 6-position barrier strip style, TBK-B02: four 6-position barrier strip style, TBK-B03: one 3-position and three 6-position barrier strip style, TBK-S01: two 6-position spring clamp style, TBK-S02: four 6-position spring clamp style, TBK-S03: one 3-position and three 6-position spring clamp style