895M, 896M: DC Input, Frequency Output Math Module
Product short description:
- 0 to 20mA DC, 0 to 10V DC (selectable ranges), 896M 2 channels input
- 0 to 10KHz, 0 to 36,000 counts/hr Frequency output, 896M 2 channels
- Solid-state relay (60V DC @ 500mA) control output
- 10-36V DC power
- Software configured, ideal for integrator/totalizer applications, computes arithmetic operations, conditional arguments, track & hold functions
- Description
- Features & Benefits
- Tech Papers
- Specs & Data Sheets
- Software
- Accessories
- Additional information
895M, 896M Frequency Output Math Module Description
IntelliPack math modules perform complex mathematical computations and convert DC input signals to scaled DC or frequency outputs. They are ideal for isolating and interfacing analog signals to a PLC or controller as a voltage, current, or a pulsed input. Typical applications include calculating a sum, delta’s, average, flow rate, volume, weight, power, and other scaled or computed variables.
Math modules are available with either DC voltage/current output or frequency/pulse-width modulated output. Each output (DC, frequency, and relay channels) is controlled by a unique, user-defined equation.
The math/computation equations are entered into the IntelliPack configuration software in a free form format, the same as in most popular spreadsheet programs. A simulator screen provides instant feedback to test equations and see the output response before actual installation.
Performance
General
Analog to Digital (A/D) Converter: 16-bit Σ-Δ A/D converter
Input Accuracy: Better than ±0.05% of input span.
Input Zero Dropout Threshold: 0 to 10% of input span, user-defined
Ambient Temperature Effect: Better than ±0.005% of input span per °C or ±1μV, whichever is greater.
Noise Rejection:
Normal Mode: 40dB @ 60Hz
Common Mode: 100dB @ 60Hz
Input Over-voltage Protection: Bipolar Transient Voltage Suppressors (TVS)
Input Scaling: Input signal endpoints are scaled using IntelliPack Configuration Software.
Response Time (for input step change): 70mS typical to 98% of final output value
DC Current Inputs
DC Current Input Ranges:Â 0 to 1mA, 0 to 20mA, 4 to 20mA DC
DC Current Input Impedance: 49.9 ohms
Frequency Output
Output Type:
Open -drain MOSFETs, 60V DC @ 1A DC
On resistance: 0.2 ohms
Frequency Range: 0 to 10KHz (100% scalable) or 0 to 36,000 counts per hour (CPH)
Output Scaling: Output signal endpoints are scaled using IntelliPack Configuration Software. Output frequency is limited from a minimum span of 0-10Hz to a maximum span of 0-10KHz or from 0-10CPH to 0-36000 CPH.
Output Pullups:
470 ohms to 5V via pullup terminals.
60V DC with external pullup resistor.
Output Duty Cycle: User-defined on-time from 0 to 100% of frequency range.
Relay Control Outputs
Solid-State Relay:
Form A normally-open switch
Maximum current: 500mA DC
Maximum off-state voltage: 60V DC
Maximum on-state resistance: 0.7 ohms
Environmental
Ambient Temperature:
Operating: -25 to 70°C (-13 to 158°F)
Storage: -40 to 85°C (-40 to 185°F)
Relative Humidity: 5 to 95%
Power Requirements: 10 to 36V DC. 55mA @ 24V.
Isolation (optical):
4-way (input/output/relays/power)
Input circuits share a common
1500V AC peak or 250V AC (354V DC) continuous
Radiated Field Immunity (RFI): EN61000-4-3, EN50082-1
Electromagnetic Field Immunity (EMI):
Less than ±0.25% of output span effect under the influence of electromagnetic fields from switching solenoids, commutator motors, and drill motors.
Electrical Fast Transient (EFT): EN61000-4-4, EN50082-1
Surge Withstanding Capability (SWC): EN61000-4-5, EN50082-1
Electrostatic Discharge (ESD): EN61000-4-2, EN50082-1
Radiated Emissions: EN50081-1 for Class B equipment
Approvals:
UL listed (USA, Canada)
UL3121 – general product safety
Configuration
Software Configuration: Units are fully programmable via the Windows 7 or newer IntelliPack Configuration Program. Configuration downloads from PC through EIA232 serial port using Acromag 800C-SIP kit.
LED Indicators: LEDs indicate power, status, and relay.
Physical
Enclosure: Case: Self-extinguishing NYLON type 6.6 polyamide thermoplastic UL94 V-2, color beige; general purpose NEMA Type 1 enclosure.
Connectors (Removable terminal blocks): Wire Range: AWG #14-24
Printed Circuit Boards: Military grade FR-4 epoxy glass circuit board
Dimensions
1.05W x 4.68H x 4.35D inches
26.7W x 118.9H x 110.5D millimeters
Shipping Weight: 1 pound (0.45 Kg) packed
- Universal DC analog I/O ranges provide flexibility for changing application requirements.
- Individual channel input/output scaling displays signal values in engineering units.
- Track and hold function enables easy identification of critical events and their corresponding signal values.
- 200-character equation fields (50-char. max. on 895/896M) support complex transfer functions.
- Software simulation feature allows off-line testing of equations to quickly check output signal response for a variety of conditions.
- Diagnostic LEDs provide quick, visual indication of an out-of-range input value.
- Pulse-width modulation capability allows the user to vary the output signal’s pulse width on a user-defined carrier frequency.
- Solid-state relays provide on/off control or local alarms with fail-safe/ non fail-safe capability
Specifications
Manuals
Brochures
Drawings & Diagrams
-
20RM-16-DIN: 19” rack-mount kit with DIN rail
- 19" rack-mount kit with DIN rail
$185Select options -
4001-095: USB-to-Serial Adapter
- USB-to-serial adapter
- Easy to use to setup and re-configure modules
$40Select options -
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
$50Select options -
800C-SIP: IntelliPack Configuration Software
- Configuration Software
- USB-to-RS232 Adapter
- RS232-to-RJ11 Adapter
- Interface Cable
$300Select options -
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
$95 – $245Select options -
Terminal Block Replacements
- Simplifies wiring connections on Acromag I/O Modules
- Barrier strip or spring clamp terminal block kits
- Provide safe and secure wiring connections
$30 – $40Select options
Additional information
Weight | 11 oz |
---|---|
Dimensions | 5 × 1.25 × 4.5 in |
Part Number | 895M-0800: one DC voltage/current input; one frequency output; one control/relay output, 895M-0800-C: one DC voltage/current input; one frequency output; one control/relay output, with factory configuration, 896M-0800: two DC voltage/current inputs; two frequency outputs; two control/relay outputs, 896M-0800-C: two DC voltage/current inputs; two frequency outputs; two control/relay outputs, with factory configuration |
Configuration | Windows Software Configuration |
Product Series | IntelliPack 800 Series |
Power | DC Power, External Power |
-
Description
895M, 896M Frequency Output Math Module Description
IntelliPack math modules perform complex mathematical computations and convert DC input signals to scaled DC or frequency outputs. They are ideal for isolating and interfacing analog signals to a PLC or controller as a voltage, current, or a pulsed input. Typical applications include calculating a sum, delta’s, average, flow rate, volume, weight, power, and other scaled or computed variables.
Math modules are available with either DC voltage/current output or frequency/pulse-width modulated output. Each output (DC, frequency, and relay channels) is controlled by a unique, user-defined equation.
The math/computation equations are entered into the IntelliPack configuration software in a free form format, the same as in most popular spreadsheet programs. A simulator screen provides instant feedback to test equations and see the output response before actual installation.
Performance
General
Analog to Digital (A/D) Converter: 16-bit Σ-Δ A/D converter
Input Accuracy: Better than ±0.05% of input span.
Input Zero Dropout Threshold: 0 to 10% of input span, user-defined
Ambient Temperature Effect: Better than ±0.005% of input span per °C or ±1μV, whichever is greater.
Noise Rejection:
Normal Mode: 40dB @ 60Hz
Common Mode: 100dB @ 60Hz
Input Over-voltage Protection: Bipolar Transient Voltage Suppressors (TVS)
Input Scaling: Input signal endpoints are scaled using IntelliPack Configuration Software.
Response Time (for input step change): 70mS typical to 98% of final output valueDC Current Inputs
DC Current Input Ranges:Â 0 to 1mA, 0 to 20mA, 4 to 20mA DC
DC Current Input Impedance: 49.9 ohmsFrequency Output
Output Type:
Open -drain MOSFETs, 60V DC @ 1A DC
On resistance: 0.2 ohms
Frequency Range: 0 to 10KHz (100% scalable) or 0 to 36,000 counts per hour (CPH)
Output Scaling: Output signal endpoints are scaled using IntelliPack Configuration Software. Output frequency is limited from a minimum span of 0-10Hz to a maximum span of 0-10KHz or from 0-10CPH to 0-36000 CPH.
Output Pullups:
470 ohms to 5V via pullup terminals.
60V DC with external pullup resistor.
Output Duty Cycle: User-defined on-time from 0 to 100% of frequency range.Relay Control Outputs
Solid-State Relay:
Form A normally-open switch
Maximum current: 500mA DC
Maximum off-state voltage: 60V DC
Maximum on-state resistance: 0.7 ohmsEnvironmental
Ambient Temperature:
Operating: -25 to 70°C (-13 to 158°F)
Storage: -40 to 85°C (-40 to 185°F)
Relative Humidity: 5 to 95%
Power Requirements: 10 to 36V DC. 55mA @ 24V.
Isolation (optical):
4-way (input/output/relays/power)
Input circuits share a common
1500V AC peak or 250V AC (354V DC) continuous
Radiated Field Immunity (RFI): EN61000-4-3, EN50082-1
Electromagnetic Field Immunity (EMI):
Less than ±0.25% of output span effect under the influence of electromagnetic fields from switching solenoids, commutator motors, and drill motors.
Electrical Fast Transient (EFT): EN61000-4-4, EN50082-1
Surge Withstanding Capability (SWC): EN61000-4-5, EN50082-1
Electrostatic Discharge (ESD): EN61000-4-2, EN50082-1
Radiated Emissions: EN50081-1 for Class B equipment
Approvals:
UL listed (USA, Canada)
UL3121 – general product safetyConfiguration
Software Configuration: Units are fully programmable via the Windows 7 or newer IntelliPack Configuration Program. Configuration downloads from PC through EIA232 serial port using Acromag 800C-SIP kit.
LED Indicators: LEDs indicate power, status, and relay.Physical
Enclosure: Case: Self-extinguishing NYLON type 6.6 polyamide thermoplastic UL94 V-2, color beige; general purpose NEMA Type 1 enclosure.
Connectors (Removable terminal blocks): Wire Range: AWG #14-24
Printed Circuit Boards: Military grade FR-4 epoxy glass circuit board
Dimensions
1.05W x 4.68H x 4.35D inches
26.7W x 118.9H x 110.5D millimeters
Shipping Weight: 1 pound (0.45 Kg) packed -
Features & Benefits
- Universal DC analog I/O ranges provide flexibility for changing application requirements.
- Individual channel input/output scaling displays signal values in engineering units.
- Track and hold function enables easy identification of critical events and their corresponding signal values.
- 200-character equation fields (50-char. max. on 895/896M) support complex transfer functions.
- Software simulation feature allows off-line testing of equations to quickly check output signal response for a variety of conditions.
- Diagnostic LEDs provide quick, visual indication of an out-of-range input value.
- Pulse-width modulation capability allows the user to vary the output signal’s pulse width on a user-defined carrier frequency.
- Solid-state relays provide on/off control or local alarms with fail-safe/ non fail-safe capability
-
Tech Papers
How to Calculate the Discharge Rate Q (g.p.h.) Output of a V-notch Weir Application NoteDefining the Problem: Calculate the discharge rate Q (g.p.h.) output of a V-notch weir. Provide a 4-20mA output for flowrate and frequency output for totalization and alarm output for high-level alarm. Solution: Model 892M-0500 DC output math module Model 895M-0800 freq. output math module Model 800C-SIP software interface package Optional: Model PS5R-VD24 power supply ... -
Specs & Data Sheets
Specifications
Manuals
Brochures
Drawings & Diagrams
-
Software
IntelliPack Configuration Software 5030-881 (Log in to download the file) -
Accessories
-
20RM-16-DIN: 19” rack-mount kit with DIN rail
- 19" rack-mount kit with DIN rail
$185Select options -
4001-095: USB-to-Serial Adapter
- USB-to-serial adapter
- Easy to use to setup and re-configure modules
$40Select options -
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
$50Select options -
800C-SIP: IntelliPack Configuration Software
- Configuration Software
- USB-to-RS232 Adapter
- RS232-to-RJ11 Adapter
- Interface Cable
$300Select options -
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
$95 – $245Select options -
Terminal Block Replacements
- Simplifies wiring connections on Acromag I/O Modules
- Barrier strip or spring clamp terminal block kits
- Provide safe and secure wiring connections
$30 – $40Select options
-
-
Additional information
Additional information
Weight 11 oz Dimensions 5 × 1.25 × 4.5 in Part Number 895M-0800: one DC voltage/current input; one frequency output; one control/relay output, 895M-0800-C: one DC voltage/current input; one frequency output; one control/relay output, with factory configuration, 896M-0800: two DC voltage/current inputs; two frequency outputs; two control/relay outputs, 896M-0800-C: two DC voltage/current inputs; two frequency outputs; two control/relay outputs, with factory configuration
Configuration Windows Software Configuration
Product Series IntelliPack 800 Series
Power DC Power, External Power
Please login to submit this form.