250T-mV, 350T-mV, 450T-mV Loop, DC, or AC Power Transmitter
Product short description:
- DC milliVolt Input
- DC Voltage or DC Current Output
These models convert sensor inputs to proportional process current or voltage output signals.
Models
250T: Loop-powered transmitter series
350T: DC-powered transmitter series
450T: AC-powered transmitter series
Performance Specifications
Input Ranges:
milliVolt: -25 to 250mV
Narrow Span: 3 to 5mV, custom calibration
Output Ranges:
DC Current: 4 to 20mA
DC voltage: 0 to 5V or 0 to 10V
Power Requirements:
250T: 12 to 50V DC @ 20mA (loop-powered)
350T: DC Voltage Source
Output Range Power
4 to 20mA 10 to 36V DC @ 30mA
0 to 5V 10 to 36V DC @ 9mA
0 to 10V 12.5 to 36V DC @ 9mA
450T: 115V or 230V AC, ±10%, 50 to 60Hz
Output Range Power
4 to 20mA 115V AC @ 0.050A
4 to 20mA 230V AC @ 0.025A
0 to 5V, 0 to 10V 115V AC @ 0.020A
0 to 5V, 0 to 10V 230V AC @ 0.010A
Ambient Temperature Range:
Operating: -13 to 185°F (-25 to 85°C)
Storage: -40 to 185°F (-40 to 85°C)
Accuracy:
±0.1% of calibrated span or ±0.01mV, whichever is greater. Includes repeat-ability, hysteresis, terminal point linearity, and adjustment resolution.
Ambient Temperature Effect:
Less than ±0.01% of output span per °F (±0.018% per °C).
±0.025% of output span per °F (±0.045% per °C) for narrow span units.
(Specification includes the combined effects of zero and span over temperature)
Noise Resistance:
RFI: Less than ±0.5% ,of output span effect.
EMI: Less than ±0.25% of output span effect.
Noise Rejection:
Common Mode: 130dB at 60Hz, 100 ohm unbalance
Normal Mode: 30dB at 60Hz, 100 ohm source
Response Time: Output reaches 98% of output span in 300mS.
Bandwidth: -3dB at 3 Hz, typical
Output Compliance:
250T: RLOAD (max.) = (VSUPPLY – 12V) / 20mA
350T: RLOAD (max.) = (VSUPPLY – 2.5V) / 20mA
450T: RLOAD = 600 ohms
- Excellent accuracy and stability ensure reliable measurements in harsh industrial environments
- RFI and EMI resistance minimize the effects of environmental noise
- 90% span adjustment enables precise application calibration
- 1500V AC peak isolation (250V AC or 354V DC continuous) prevents ground loops
- Compact, 1-inch wide housing uses less space for easier installation in control panels
- Low power consumption. 350T units operate on currents as low as 9mA to help prevent expensive upgrades to larger power supplies
Specifications
Additional information
Weight | 16 oz |
---|---|
Dimensions | 3 × 1 × 3.2 in |
Part Number | 250T-MV1-DIN-NCR: up to 80mV input, DIN rail G or T mount, no certification/approval required, 250T-MV2-DIN-NCR: up to 375mV input, DIN rail G or T mount, no certification/approval required, 250T-MV3-DIN-NCR-C: narrow span, up to 30mV input, DIN rail G or T mount, no certification/approval required Unit requires factory calibration, specify ranges on order, 350T-MV1-V0-DIN-NCR: up to 80mV input; 0 to 10V DC output; DIN rail G or T mount; no certification/approval required, 350T-MV1-V5-DIN-NCR: up to 80mV input; 0 to 5V DC output; DIN rail G or T mount; no certification/approval required, 350T-MV1-Y-DIN-NCR: up to 80mV input; 4 to 20mA DC output; DIN rail G or T mount; no certification/approval required, 350T-MV2-V0-DIN-NCR: up to 375mV input; 0 to 10V DC output; DIN rail G or T mount; no certification/approval required, 350T-MV2-V5-DIN-NCR: up to 375mV output; 0 to 5V DC output; DIN rail G or T mount; no certification/approval required, 350T-MV2-Y-DIN-NCR: up to 375mV output; 4 to 20mA DC output; DIN rail G or T mount; no certification/approval required, 350T-MV3-Y-DIN-NCR-C: narrow span, up to 30mV input, 4 to 20mA DC output; DIN rail G or T mount; no certification/approval required Unit requires factory calibration, specify ranges on order, 450T-MV1-Y-1-DIN-NCR: up to 80mV input; 4 to 20mA DC output, 115V AC power; DIN rail G or T mount; no certification/approval required, 450T-MV2-Y-1-DIN-NCR: up to 375mV input; 4-20mA DC output; 115V AC power; DIN rail G or T mount; no certification/approval required, 450T-MV3-Y-1-DIN-NCR-C: narrow span, up to 30mV input; 4 to 20mA DC output; 115V AC power; DIN rail G or T mount; no certification/approval required Unit requires factory calibration, specify ranges on order |
Product Series | FlatPack Series |
-
Description
These models convert sensor inputs to proportional process current or voltage output signals.
Models
250T: Loop-powered transmitter series
350T: DC-powered transmitter series
450T: AC-powered transmitter seriesPerformance Specifications
Input Ranges:
milliVolt: -25 to 250mV
Narrow Span: 3 to 5mV, custom calibration
Output Ranges:
DC Current: 4 to 20mA
DC voltage: 0 to 5V or 0 to 10V
Power Requirements:
250T: 12 to 50V DC @ 20mA (loop-powered)350T: DC Voltage Source
Output Range Power
4 to 20mA 10 to 36V DC @ 30mA
0 to 5V 10 to 36V DC @ 9mA
0 to 10V 12.5 to 36V DC @ 9mA450T: 115V or 230V AC, ±10%, 50 to 60Hz
Output Range Power
4 to 20mA 115V AC @ 0.050A
4 to 20mA 230V AC @ 0.025A
0 to 5V, 0 to 10V 115V AC @ 0.020A
0 to 5V, 0 to 10V 230V AC @ 0.010AAmbient Temperature Range:
Operating: -13 to 185°F (-25 to 85°C)
Storage: -40 to 185°F (-40 to 85°C)
Accuracy:
±0.1% of calibrated span or ±0.01mV, whichever is greater. Includes repeat-ability, hysteresis, terminal point linearity, and adjustment resolution.
Ambient Temperature Effect:
Less than ±0.01% of output span per °F (±0.018% per °C).
±0.025% of output span per °F (±0.045% per °C) for narrow span units.
(Specification includes the combined effects of zero and span over temperature)
Noise Resistance:
RFI: Less than ±0.5% ,of output span effect.
EMI: Less than ±0.25% of output span effect.
Noise Rejection:
Common Mode: 130dB at 60Hz, 100 ohm unbalance
Normal Mode: 30dB at 60Hz, 100 ohm source
Response Time: Output reaches 98% of output span in 300mS.
Bandwidth: -3dB at 3 Hz, typical
Output Compliance:
250T: RLOAD (max.) = (VSUPPLY – 12V) / 20mA
350T: RLOAD (max.) = (VSUPPLY – 2.5V) / 20mA
450T: RLOAD = 600 ohms -
Features & Benefits
- Excellent accuracy and stability ensure reliable measurements in harsh industrial environments
- RFI and EMI resistance minimize the effects of environmental noise
- 90% span adjustment enables precise application calibration
- 1500V AC peak isolation (250V AC or 354V DC continuous) prevents ground loops
- Compact, 1-inch wide housing uses less space for easier installation in control panels
- Low power consumption. 350T units operate on currents as low as 9mA to help prevent expensive upgrades to larger power supplies
-
Specs & Data Sheets
Specifications
-
Accessories
-
Additional information
Additional information
Weight 16 oz Dimensions 3 × 1 × 3.2 in Part Number 250T-MV1-DIN-NCR: up to 80mV input, DIN rail G or T mount, no certification/approval required, 250T-MV2-DIN-NCR: up to 375mV input, DIN rail G or T mount, no certification/approval required, 250T-MV3-DIN-NCR-C: narrow span, up to 30mV input, DIN rail G or T mount, no certification/approval required Unit requires factory calibration, specify ranges on order, 350T-MV1-V0-DIN-NCR: up to 80mV input; 0 to 10V DC output; DIN rail G or T mount; no certification/approval required, 350T-MV1-V5-DIN-NCR: up to 80mV input; 0 to 5V DC output; DIN rail G or T mount; no certification/approval required, 350T-MV1-Y-DIN-NCR: up to 80mV input; 4 to 20mA DC output; DIN rail G or T mount; no certification/approval required, 350T-MV2-V0-DIN-NCR: up to 375mV input; 0 to 10V DC output; DIN rail G or T mount; no certification/approval required, 350T-MV2-V5-DIN-NCR: up to 375mV output; 0 to 5V DC output; DIN rail G or T mount; no certification/approval required, 350T-MV2-Y-DIN-NCR: up to 375mV output; 4 to 20mA DC output; DIN rail G or T mount; no certification/approval required, 350T-MV3-Y-DIN-NCR-C: narrow span, up to 30mV input, 4 to 20mA DC output; DIN rail G or T mount; no certification/approval required Unit requires factory calibration, specify ranges on order, 450T-MV1-Y-1-DIN-NCR: up to 80mV input; 4 to 20mA DC output, 115V AC power; DIN rail G or T mount; no certification/approval required, 450T-MV2-Y-1-DIN-NCR: up to 375mV input; 4-20mA DC output; 115V AC power; DIN rail G or T mount; no certification/approval required, 450T-MV3-Y-1-DIN-NCR-C: narrow span, up to 30mV input; 4 to 20mA DC output; 115V AC power; DIN rail G or T mount; no certification/approval required Unit requires factory calibration, specify ranges on order
Product Series FlatPack Series
Please login to submit this form.