These models convert sensor inputs to proportional process current or voltage output signals.

250T models: Input isolated from output and power.

350T models: Input isolated from output and power. Output and power share a common.

450T models: 3-way isolation. Input, output, and power circuits are isolated from each other.

  • Excellent accuracy and stability ensure reliable measurements in harsh industrial environments
  • RFI and EMI resistance minimize the effects of environmental noise
  • 90% span adjustment enables precise application calibration
  • 1500V AC peak isolation (250V AC or 354V DC continuous) prevents ground loops
  • Compact, 1-inch wide housing uses less space for easier installation in control panels
  • Low power consumption. 350T units operate on currents as low as 9mA to help prevent expensive upgrades to larger power supplies

Manuals

250T-mV Series User Manual (Log in to download the file)

350T-mV Series User Manual (Log in to download the file)

450T-mV Series User Manual (Log in to download the file)

Additional information

Weight 16 oz
Dimensions 3 × 1 × 3.2 in
Part Number

250T-MV1-DIN-NCR: up to 80mV input, DIN rail G or T mount, no certification/approval required, 250T-MV2-DIN-NCR: up to 375mV input, DIN rail G or T mount, no certification/approval required, 250T-MV3-DIN-NCR-C: narrow span, up to 30mV input, DIN rail G or T mount, no certification/approval required Unit requires factory calibration, specify ranges on order, 250T-MV3-N12-NCR-C: narrow span, up to 30mV input; NEMA 12, oil-tight external housing (holds two); no certification/approval required Unit requires factory calibration, specify ranges on order, 250T-MV3-XP-NCR-C: narrow span, up to 30mV input; explosion-proof NEMA 4 (holds one) external housing; no certification/approval required Unit requires factory calibration, specify ranges on order, 350T-MV1-V0-DIN-NCR: up to 80mV input; 0 to 10V DC output; DIN rail G or T mount; no certification/approval required, 350T-MV1-V5-DIN-NCR: up to 80mV input; 0 to 5V DC output; DIN rail G or T mount; no certification/approval required, 350T-MV1-Y-DIN-NCR: up to 80mV input; 4 to 20mA DC output; DIN rail G or T mount; no certification/approval required, 350T-MV2-V0-DIN-NCR: up to 375mV input; 0 to 10V DC output; DIN rail G or T mount; no certification/approval required, 350T-MV2-V5-DIN-NCR: up to 375mV output; 0 to 5V DC output; DIN rail G or T mount; no certification/approval required, 350T-MV2-Y-DIN-NCR: up to 375mV output; 4 to 20mA DC output; DIN rail G or T mount; no certification/approval required, 350T-MV3-Y-DIN-NCR-C: narrow span, up to 30mV input, 4 to 20mA DC output; DIN rail G or T mount; no certification/approval required Unit requires factory calibration, specify ranges on order, 450T-MV1-Y-1-DIN-NCR: up to 80mV input; 4 to 20mA DC output, 115V AC power; DIN rail G or T mount; no certification/approval required, 450T-MV2-Y-1-DIN-NCR: up to 375mV input; 4-20mA DC output; 115V AC power; DIN rail G or T mount; no certification/approval required, 450T-MV3-Y-1-DIN-NCR-C: narrow span, up to 30mV input; 4 to 20mA DC output; 115V AC power; DIN rail G or T mount; no certification/approval required Unit requires factory calibration, specify ranges on order

Communication
Configuration
FPGA Type
Logic Cells
Power
Product Series

FlatPack Series

  • Description

    These models convert sensor inputs to proportional process current or voltage output signals.

    250T models: Input isolated from output and power.

    350T models: Input isolated from output and power. Output and power share a common.

    450T models: 3-way isolation. Input, output, and power circuits are isolated from each other.

  • Features & Benefits

    • Excellent accuracy and stability ensure reliable measurements in harsh industrial environments
    • RFI and EMI resistance minimize the effects of environmental noise
    • 90% span adjustment enables precise application calibration
    • 1500V AC peak isolation (250V AC or 354V DC continuous) prevents ground loops
    • Compact, 1-inch wide housing uses less space for easier installation in control panels
    • Low power consumption. 350T units operate on currents as low as 9mA to help prevent expensive upgrades to larger power supplies
  • Specs & Data Sheets

    Manuals

    250T-mV Series User Manual (Log in to download the file)

    350T-mV Series User Manual (Log in to download the file)

    450T-mV Series User Manual (Log in to download the file)

  • Additional information

    Additional information

    Weight 16 oz
    Dimensions 3 × 1 × 3.2 in
    Part Number

    250T-MV1-DIN-NCR: up to 80mV input, DIN rail G or T mount, no certification/approval required, 250T-MV2-DIN-NCR: up to 375mV input, DIN rail G or T mount, no certification/approval required, 250T-MV3-DIN-NCR-C: narrow span, up to 30mV input, DIN rail G or T mount, no certification/approval required Unit requires factory calibration, specify ranges on order, 250T-MV3-N12-NCR-C: narrow span, up to 30mV input; NEMA 12, oil-tight external housing (holds two); no certification/approval required Unit requires factory calibration, specify ranges on order, 250T-MV3-XP-NCR-C: narrow span, up to 30mV input; explosion-proof NEMA 4 (holds one) external housing; no certification/approval required Unit requires factory calibration, specify ranges on order, 350T-MV1-V0-DIN-NCR: up to 80mV input; 0 to 10V DC output; DIN rail G or T mount; no certification/approval required, 350T-MV1-V5-DIN-NCR: up to 80mV input; 0 to 5V DC output; DIN rail G or T mount; no certification/approval required, 350T-MV1-Y-DIN-NCR: up to 80mV input; 4 to 20mA DC output; DIN rail G or T mount; no certification/approval required, 350T-MV2-V0-DIN-NCR: up to 375mV input; 0 to 10V DC output; DIN rail G or T mount; no certification/approval required, 350T-MV2-V5-DIN-NCR: up to 375mV output; 0 to 5V DC output; DIN rail G or T mount; no certification/approval required, 350T-MV2-Y-DIN-NCR: up to 375mV output; 4 to 20mA DC output; DIN rail G or T mount; no certification/approval required, 350T-MV3-Y-DIN-NCR-C: narrow span, up to 30mV input, 4 to 20mA DC output; DIN rail G or T mount; no certification/approval required Unit requires factory calibration, specify ranges on order, 450T-MV1-Y-1-DIN-NCR: up to 80mV input; 4 to 20mA DC output, 115V AC power; DIN rail G or T mount; no certification/approval required, 450T-MV2-Y-1-DIN-NCR: up to 375mV input; 4-20mA DC output; 115V AC power; DIN rail G or T mount; no certification/approval required, 450T-MV3-Y-1-DIN-NCR-C: narrow span, up to 30mV input; 4 to 20mA DC output; 115V AC power; DIN rail G or T mount; no certification/approval required Unit requires factory calibration, specify ranges on order

    Communication
    Configuration
    FPGA Type
    Logic Cells
    Power
    Product Series

    FlatPack Series