Product short description:
  • 0 to 20mA DC, 0 to 10V DC output
  • Mechanical relay (25V @ 5A) alarm
  • 10-36V DC power
  • Software configured
  • Performs linearization, square root extraction, and optional limit alarm functions
RSS
FACEBOOK
FACEBOOK
TWITTER
Visit Us
LINKEDIN

Description

These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function.

Each unit offers a selection of input and output ranges, as well as several signal conditioning options. This flexibility enables a single IntelliPack to handle a broad range of applications. As your needs change, you can easily reconfigure the unit for different ranges or functions.

Setup is very easy. IntelliPack modules are quickly configured with the user-friendly Windows software program. Field adjustments are simple with the module’s front-panel push-buttons and status LEDs. Once configured, IntelliPacks operate independent of any host computer.

Performance

General Input

Analog to Digital (A/D) Converter: 16-bit Σ-Δ A/D converter
Resolution: ±0.005% of span or 0.1°C
Ambient Temperature Effect: Better than ±0.005% of input span per °C or ±1μV, whichever is greater.
Noise Rejection:
Normal Mode: Better than 40dB @ 60Hz
Common Mode: Better than 130dB @ 60Hz
Input Response Time (for input step change): Less than 200mS typical to 98% of final output value
Input Over-voltage Protection: Bipolar Transient Voltage Suppressors (TVS)

Thermocouple Input

Thermocouple Input Ranges
Thermocouple type user configured. Signal linearization, cold-junction compensation, and open circuit or lead break detection are included.
TC             °C Range (°F Range)                     Accuracy
J        -210 to  760°C (-346 to 1400°F)              ±0.5°C
K       -200 to 1372°C (-328 to 2502°F)             ±0.5°C
T       -260 to  400°C (-436 to 752°F)                 ±0.5°C
R         -50 to 1768°C (-58 to 3214°F)                ±1.0°C
S         -50 to 1768°C (-58 to 3214°F)                ±1.0°C
E       -200 to 1000°C (-328 to 1832°F)             ±0.5°C
B        260 to 1820°C (500 to 3308°F)               ±1.0°C
N      -230 to 1300°C (-382 to 2372°F)             ±1.0°C

Thermocouple Break Detection: TC sensor failure can be configured for either upscale or downscale

RTD Input

RTD Input Ranges:100 ohm Platinum, 120 ohm Nickel, or 10 ohm Copper; user-configured

RTD                °C Range (°F Range)                       Accuracy
Pt1            -200 to 850°C (-328 to 1562°F)              ±0.25°C
Pt2            -200 to 850°C (-328 to 1562°F)              ±0.25°C
Ni                 -80 to 320°C (-112 to 608°F)                 ±0.25°C
Cu             -200 to 260°C (-328 to 500°F)                 ±1.00°C
Alpha: Pt1 (a = 1.3850), Pt2 (a = 1.3911), Ni (a = 1.6720), Cu (a = 1.4272)
2, 3, or 4-wire configurations supported. Module provides sensor excitation, linearization, lead-wire compensation, and sensor break detection.

RTD Excitation Current:
1mA DC typical, all types
RTD Lead-Wire Compensation: 25 ohms per lead
RTD Break Detection: RTD sensor failure can be configured for either upscale or downscale.

milliVolt Input

DC milliVolt/Voltage Input Ranges: 
±1.0V           ±125mV          ±31.25mV
±500mV     ±62.5mV        ±15.625mV       ±250mV

milliVolt Accuracy: better than ±0.05% of input span

Resistance Input

Resistance Input Range: 0 to 500 ohms
Resistance Accuracy: ±0.05 ohms

Output (DC V/mA)

D/A Converter: 16-bit Σ-Δ
Current Output:
0-1mA, 0-20mA, 4-20mA
Compliance: 10V minimum (500 ohm load)
Accuracy: 0.025% of span
Voltage Output:
Ranges: 0-5V, 0-10V
Compliance: 10mA maximum with short circuit protection. 1 ohm output impedance
Accuracy: 0.025% of span
Accuracy (overall input to output): 0.075% of span

Output (Relay)

Relay: One SPDT electro-mechanical relay
Relay Ratings (CSA ratings):
25V DC @ 5A
120/240V AC @ 5A
Relay Time Delay: Adjustable alarm delay of up to 25 seconds
Contact Material: Silver-cadmium oxide (AgCdO)
Expected Mechanical Life: 20 million operations

Environmental

Ambient Temperature:
Operating: -25 to 70°C (-13 to 158°F)
Storage: -40 to 85°C (-40 to 185°F)
Relative Humidity: 5 to 95%
Power Requirements: 10 to 36V DC. 75mA @ 24V. 120mA @ 15V
Isolation (optical):
4-way (input/output/relay/power)
1500V AC for 60 seconds or 250V AC continuous
Radiated Field Immunity (RFI): EN61000-4-3, EN50082-1
Electromagnetic Field Immunity (EMI):
Less than ±0.25% of output span effect under the influence of electromagnetic fields from switching solenoids, commutator motors, and drill motors.
Electrical Fast Transient (EFT): EN61000-4-4, EN50082-1
Surge Withstanding Capability (SWC): EN61000-4-5, EN50082-1
Electrostatic Discharge (ESD): EN61000-4-2, EN50082-1
Radiated Emissions: EN50081-1 for Class B equipment
Approvals:
UL, cUL listed (USA, Canada)
UL3121 – general product safety

Configuration

Software Configuration: Units are fully programmable via the Windows 7 or newer IntelliPack Configuration Program. Configuration downloads from PC through EIA232 serial port using Acromag 800C-SIP kit.
Field Configuration: Output, zero/full-scale, relay setpoint and deadband are configurable via push-buttons and a standard calibrator.
LED Indicators: LEDs indicate power, status, calibration, and alarm.

Physical

Enclosure: Case: Self-extinguishing NYLON type 6.6 polyamide thermoplastic UL94 V-2, color beige; general purpose NEMA Type 1 enclosure.
Connectors (Removable terminal blocks): Wire Range: AWG #14-22 (AWG #12 stranded only)
Printed Circuit Boards: Military grade FR-4 epoxy glass circuit board
Dimensions
1.05W x 4.68H x 4.35D inches
26.7W x 118.9H x 110.5D millimeters
Shipping Weight: 1 pound (0.45 Kg) packed

  • High-resolution Sigma-Delta A/D converter delivers high accuracy with low noise.
  • Advanced micro-controller provides intelligent signal processing power for linearization, averaging, and square root computations.
  • Windows 7 or newer software configuration speeds setup and replacement.
  • Multi-purpose inputs and outputs reduce spare stock requirements.
  • Relay output option provides local limit alarm capability.

Specifications

Manuals

801T User Manual (Log in to download the file)

IntelliPack Configuration Software 5030-881 (Log in to download the file)
  • Compare

    20RM-16-DIN: 19” rack-mount kit with DIN rail

    • 19" rack-mount kit with DIN rail
    $175
    Select options
  • Compare

    4001-095: USB-to-Serial Adapter

    • USB-to-serial adapter
    • Easy to use to setup and re-configure modules
    $35
    Select options
  • Compare

    5030 Cable Series

    • Various specialty cables
    $15$70
    Select options
  • Compare

    5030-881

    • IntelliPack 800 Series software on CD-ROM
    $55
    Select options
  • Compare

    800C-SIP: IntelliPack Configuration Software

    • Configuration Software
    • USB-to-RS232 Adapter
    • RS232-to-RJ11 Adapter
    • Interface Cable
    $285
    Select options
  • Compare

    PS5R: Slim Line Power Supplies

    • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
    • Universal Input (85-264V AC / 100-370V DC)
    • Lightweight and compact size
    $95$245
    Select options
  • Compare

    Terminal Block Replacements

    • Simplifies wiring connections on Acromag I/O Modules
    • Barrier strip or spring clamp terminal block kits
    • Provide safe and secure wiring connections
    $25$35
    Select options

Additional information

Weight 8 oz
Dimensions 12 × 13 × 3 in
Part Number

TBK-B01: two 6-position barrier strip style, TBK-B02: four 6-position barrier strip style, TBK-B03: one 3-position and three 6-position barrier strip style, TBK-S01: two 6-position spring clamp style, TBK-S02: four 6-position spring clamp style, TBK-S03: one 3-position and three 6-position spring clamp style

  • Description

    These optional terminal blocks provide safe and secure wiring connections. Large captive screw terminals or spring clamps enable fast, easy connections. Pluggable terminals are removable for simple disconnection of the module without disturbing the wiring.

    Optional terminal blocks are compatible with Acromag’s “white box” modules including BusWorks 900 Series, IntelliPack 800 Series, and isolated transmitters 600 Series.

    Barrier Strip Terminal Blocks

    Wire Range: 12-26 AWG
    Safety Ratings: UL, CSA, CE, TUV.
    Current/Voltage Rating: 15A, 300V.
    Pin Spacing: 5.08mm (0.2”).
    Housing Material: PPO, UL 94 V-0, Black.
    Contacts: Tin-Lead Plated Phosphor Bronze.
    Screw: M3, Nickel Plated Steel.
    Insulation Resistance: ≥105 Megohms.
    Dielectric Withstand: <3000V.

    Spring Clamp Terminal Blocks

    Wire Range: 12-28 AWG.
    Safety Ratings: UL, CSA, CE, TUV.
    Current/Voltage Rating: 15A, 300V.
    Pin Spacing: 5.08mm (0.2”)
    Housing Material: PPO, UL 94 V-0, Black.
    Contacts: Tin-Lead Plated Phosphor Bronze.
    Spring Clamp: Stainless Steel.
    Insulation Resistance: ≥105 Megohms.
    Dielectric Withstand: <3000V.

    Acromag Standard Cage Clamp Terminal Blocks

    Wire Range: 12-24 AWG.
    Current/Voltage Rating: 12A, 300V (UL).
    Pin Spacing: 5.08mm (0.2”).
    Housing Material: UL 94 V-0.
    Terminal: Brass, nickel plated.
    Wire Protector with Contact: Copper alloy tin plating.
    Screw: M3, steel, nickel over copper plating.
    Contact Resistance: ≤10 milliohms per circuit.

  • Features & Benefits

    • High-resolution Sigma-Delta A/D converter delivers high accuracy with low noise.
    • Advanced micro-controller provides intelligent signal processing power for linearization, averaging, and square root computations.
    • Windows 7 or newer software configuration speeds setup and replacement.
    • Multi-purpose inputs and outputs reduce spare stock requirements.
    • Relay output option provides local limit alarm capability.
  • Specs & Data Sheets

    Specifications

    Manuals

    801T User Manual (Log in to download the file)

  • Software

    IntelliPack Configuration Software 5030-881 (Log in to download the file)
  • Accessories

    • Compare

      20RM-16-DIN: 19” rack-mount kit with DIN rail

      • 19" rack-mount kit with DIN rail
      $175
      Select options
    • Compare

      4001-095: USB-to-Serial Adapter

      • USB-to-serial adapter
      • Easy to use to setup and re-configure modules
      $35
      Select options
    • Compare

      5030 Cable Series

      • Various specialty cables
      $15$70
      Select options
    • Compare

      5030-881

      • IntelliPack 800 Series software on CD-ROM
      $55
      Select options
    • Compare

      800C-SIP: IntelliPack Configuration Software

      • Configuration Software
      • USB-to-RS232 Adapter
      • RS232-to-RJ11 Adapter
      • Interface Cable
      $285
      Select options
    • Compare

      PS5R: Slim Line Power Supplies

      • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
      • Universal Input (85-264V AC / 100-370V DC)
      • Lightweight and compact size
      $95$245
      Select options
    • Compare

      Terminal Block Replacements

      • Simplifies wiring connections on Acromag I/O Modules
      • Barrier strip or spring clamp terminal block kits
      • Provide safe and secure wiring connections
      $25$35
      Select options
  • Additional information

    Additional information

    Weight 8 oz
    Dimensions 12 × 13 × 3 in
    Part Number

    TBK-B01: two 6-position barrier strip style, TBK-B02: four 6-position barrier strip style, TBK-B03: one 3-position and three 6-position barrier strip style, TBK-S01: two 6-position spring clamp style, TBK-S02: four 6-position spring clamp style, TBK-S03: one 3-position and three 6-position spring clamp style