981EN, 982EN, 983EN: Ethernet Discrete I/O Modules
Product short description:
- 12-channel discrete input and/or output
- Ethernet/IP, Modbus TCP/IP
- i2o peer-to-peer available for Modbus TCP/IP
These modules provide an isolated Ethernet network interface for twelve discrete input and/or output channels. The outputs provide direct on/off, high/low, or open/close control of industrial devices. The inputs sense the status of motors, pumps, valves and other equipment. The 983EN model with tandem I/O provides output level control and status verification in one unit.
- Description
- Features & Benefits
- Tech Papers
- Specs & Data Sheets
- Software
- Accessories
- Additional information
Models
981EN: 12 input channels
982EN: 12 output channels
983EN: 12 input/output channels
These modules provide an isolated Ethernet network interface for twelve discrete input and/or output channels. The outputs provide direct on/off, high/low, or open/close control of industrial devices.
The inputs sense the status of motors, pumps, valves and other equipment. The 983EN model with tandem I/O provides output level control and status verification in one unit.
Input Range: 0 to 35V DC
Output Range: 0 to 35V DC
Network Communication:
EtherNet/IP
Modbus TCP/IP, (i2o® peer-to-peer available for Modbus TCP/IP only)
10/100Mbps with automatic data rate negotiation
Power Requirement: 15 to 36V DC supply (2 Watts) required
Approvals:
CE/ATEX marked
UL, cUL listed, Class I; Div. 2; Groups A, B, C, D
EtherNet/IP, Modbus/TCP conformance tested
Performance Specifications
Input (981 & 983 models)
Input Type: Twelve active-low, buffered inputs, with a common connection. Built-in 5.6K ohm pullups to excitation terminal socketed for 4-channel groups.
Input Signal Voltage Range: 0 to 35V DC, maximum
Input Impedance: 100K ohms, typical
Input Signal Threshold: TTL compatible with 100mV of hysteresis, typical
Output (982 & 983 models)
Output Type: 12 independent, open-drain, MOSFET switches
Output Voltage and ON Resistance:
0 to 35V DC maximum (0 to 500mA/channel continuous)
0.28 ohms maximum ON resistance
Network Communication:
EtherNet/IP
Modbus TCP/IP, (i2o® peer-to-peer available for Modbus TCP/IP only)
10/100Mbps with automatic data rate negotiation
Power Requirement:Â 15 to 36V DC supply (2 Watts) required
Approvals
CE/ATEX marked
UL, cUL listed, Class 1: Div, 2; Groups A, B, C, D
EtherNet/IP, Modbus/TCP conformance tested
Environmental
Ambient Temperature and Humidity:
Operating: -25 to 70°C (-13 to 158F)
Storage: -40 to 85°C (-40 to 185°F)
Relative Humidity: 5 to 95%, non-condensing
Isolation:
1500V AC for 60 seconds or 250V AC continuous
3-way isolation between I/O, network, and power
NOTE: i2o function only on Modbus TCP/IP modules. 981EN does not have the i2o feature
- Configurable from standard web browser
- 12-channel stand-alone module has far lower start-up cost than multi-piece block I/O systems
- 0-35V DC solid-state logic interface can monitor or control a wide variety of devices
- Bidirectional I/O models facilitate loopback monitoring of the output state
- Socketed SIP resistors provide input and output 5.6K ohm pull-ups to the excitation supply
- Three selectable failsafe modes (off, last-state, or pre-defined) help prevent unsafe conditions
Specifications
Manuals
Brochure
-
20RM-16-DIN: 19” rack-mount kit with DIN rail
- 19" rack-mount kit with DIN rail
$185Select options -
4001 Serial Cables
5-foot ribbon cable, DB25 male and 26-pin female IDC connectors, for 3B/5B backpanel to Ethernet I/O module connection$95Select options -
5035 Series: Ethernet Cables
- Ethernet straight cable, CAT5
- Ethernet crossover cable, CAT5E
- Low EMI Double-Shielded Ethernet Patch Cable
$40 – $115Select options -
900EN: 5-Port Ethernet Switch
- 10/100Mbps
- 15 to 36V DC power supply required
- Five shielded RJ-45 sockets, 8-pin, 10Base-T / 100Base-TX
$340Select options -
AMTN, AMTX: ActiveX / .NET Controls for Modbus I/O
- Modbus/TCP or Modbus/RTU
- These ActiveX / .NET software controls provide a fast, easy way to communicate with any Modbus slave devices connected to your PC.
- Get your Visual Basic, Visual C, .NET, Excel, or other compatible applications talking Modbus protocol within minutes.
$260 – $350Select options -
IMC-100A: 10/100BaseTX to 100BaseFX Industrial Media Converter
- UTP to Fiber Media Converter
- RJ45 Port Supports Auto MDI/MDI-X Function
$240Select options -
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
$95 – $245Select options -
Terminal Block Replacements
- Simplifies wiring connections on Acromag I/O Modules
- Barrier strip or spring clamp terminal block kits
- Provide safe and secure wiring connections
$30 – $40Select options -
USB-to-Ethernet Adapter
Simplifies configuration of Acromag Ethernet I/O Modules Prevents disruption of existing LANs This device is a USB-to-Ethernet adapter that you can use to communicate with any Acromag Ethernet I/O product for the purpose of setup and re-configuration for your application. It is recommended for initial communication with Acromag Ethernet devices so that you do not have to disrupt your existing network connection.$80Select options
Additional information
Weight | 10 oz |
---|---|
Dimensions | 4.5 × 1.5 × 5 in |
Product Number | 981EN-6012: Ethernet/IP; 12 input channels, 982EN-6012: Ethernet/IP; 12 output channels, 983EN-6012: Ethernet/IP; 12 input/output channels, 981EN-4012: Modbus TCP/IP; 12 input channels, 982EN-4012: Modbus TCP/IP; 12 output channels, i2o capability, 983EN-4012: Modbus TCP/IP; 12 input/output channels, i2o capability |
Communication | Ethernet/IP, i2o Peer-to-Peer, Modbus TCP/IP |
Configuration | Built-in Web pages |
Product Series | BusWorks 900EN Series |
Power | DC Power |
-
Description
Models
981EN: 12 input channels
982EN: 12 output channels
983EN: 12 input/output channelsThese modules provide an isolated Ethernet network interface for twelve discrete input and/or output channels. The outputs provide direct on/off, high/low, or open/close control of industrial devices.
The inputs sense the status of motors, pumps, valves and other equipment. The 983EN model with tandem I/O provides output level control and status verification in one unit.
Input Range: 0 to 35V DC
Output Range: 0 to 35V DC
Network Communication:
EtherNet/IP
Modbus TCP/IP, (i2o® peer-to-peer available for Modbus TCP/IP only)
10/100Mbps with automatic data rate negotiation
Power Requirement: 15 to 36V DC supply (2 Watts) required
Approvals:
CE/ATEX marked
UL, cUL listed, Class I; Div. 2; Groups A, B, C, D
EtherNet/IP, Modbus/TCP conformance testedPerformance Specifications
Input (981 & 983 models)
Input Type: Twelve active-low, buffered inputs, with a common connection. Built-in 5.6K ohm pullups to excitation terminal socketed for 4-channel groups.
Input Signal Voltage Range: 0 to 35V DC, maximum
Input Impedance: 100K ohms, typical
Input Signal Threshold: TTL compatible with 100mV of hysteresis, typicalOutput (982 & 983 models)
Output Type: 12 independent, open-drain, MOSFET switches
Output Voltage and ON Resistance:
0 to 35V DC maximum (0 to 500mA/channel continuous)
0.28 ohms maximum ON resistance
Network Communication:
EtherNet/IP
Modbus TCP/IP, (i2o® peer-to-peer available for Modbus TCP/IP only)
10/100Mbps with automatic data rate negotiation
Power Requirement:Â 15 to 36V DC supply (2 Watts) required
Approvals
CE/ATEX marked
UL, cUL listed, Class 1: Div, 2; Groups A, B, C, D
EtherNet/IP, Modbus/TCP conformance testedEnvironmental
Ambient Temperature and Humidity:
Operating: -25 to 70°C (-13 to 158F)
Storage: -40 to 85°C (-40 to 185°F)
Relative Humidity: 5 to 95%, non-condensing
Isolation:
1500V AC for 60 seconds or 250V AC continuous
3-way isolation between I/O, network, and powerNOTE: i2o function only on Modbus TCP/IP modules. 981EN does not have the i2o feature
-
Features & Benefits
- Configurable from standard web browser
- 12-channel stand-alone module has far lower start-up cost than multi-piece block I/O systems
- 0-35V DC solid-state logic interface can monitor or control a wide variety of devices
- Bidirectional I/O models facilitate loopback monitoring of the output state
- Socketed SIP resistors provide input and output 5.6K ohm pull-ups to the excitation supply
- Three selectable failsafe modes (off, last-state, or pre-defined) help prevent unsafe conditions
-
Tech Papers
How to Connect Acromag Series 9xxEN Modules Via RadioLinx Ethernet ModemsObjective: The purpose of this document is to provide a procedure for connecting an Acromag Series 9xxEN I/O Module to an existing network via RadioLinx Ethernet Modems. Background – IP Addresses Any TCP/IP packet contains two addresses: a unique fixed MAC address, and a unique IP address. To communicate on the Internet, computers must have...How to Communicate with Acromag Modbus/TCP Modules from Ignition Software Application NoteCommunicating with Ignition Software This document illustrates a procedure for configuring OPC tags intended for Acromag Busworks® Series Modbus/TCP modules using Windows software from Inductive Automation. It is assumed that the user has a working knowledge of OPC, Modbus TCP, and Ignition software. Product Features: BusWorks® Series 9xxEN Modules w/Modbus/TCP BusWorks® Series XT1xx1 Modules w/...How to Connect to Acromag Ethernet I/O Devices Application NoteGetting Connected to Acromag Ethernet I/O Devices These instructions summarize the basic steps you will have to take in order to initially connect an Acromag Ethernet I/O product to your Personal Computer (PC) or laptop. To connect an Ethernet device to your PC, consult with your network administrator and either temporarily change the TCP/IP configuration...How to Connect Acromag Series 900EN Ethernet Modules to Your PC Application NoteObjective: The purpose of this document is to provide a procedure for assigning a unique IP address to a second network interface card installed in a personal computer for the purpose of communicating with an Acromag Series 9xxEN Ethernet I/O Module. A procedure for accomplishing IP address assignment is provided using Windows 98, Windows ME, Windows...How to Communicate with Acromag Series 9xxEN-60xx Ethernet Modules from Compact Logix Devices Application NoteCommunicating with Acromag Series 9xxEN-60xx Ethernet Modules from Compact Logix Controllers This document illustrates a procedure for configuring message commands intended for Acromag Busworks® Series Ethernet/IP modules using ladder logic programming software and a Compact Logix Programmable Controller. It is assumed that the user has a working knowledge of ladder logic programming, the RSLogix5000 software,...How to Communicate to Acromag Series 9xxEN-6xxx & XTxx2-xxx Ethernet Modules in an Allen Bradley ControlLogix System Application NoteEthernet Modules in a ControlLogix System Objective: This document illustrates a procedure for integrating the Acromag Series 9xxEN-6xxx modules into the Allen Bradley control system as a third-party generic module. The reference model for this procedure is the Model 961EN-6006. It is assumed that the Acromag module has been assigned a static IP address and...How to Configure Kepware KEPServerEX 5.0 for Communications with Acromag BusWorks Modbus I/O Modules Application NoteConfiguring Kepware KEPServerEX 5.0 for Communications with Acromag BusWorks Modbus I/O modules. Introduction This document provides example steps for configuring the Kepware KEPServerEX OPC Server for communications with Acromag Busworks Modbus RTU and Modbus TCP/IP Distributed I/O Modules. Once the server is configured, data may be read from or written to the I/O module using...How to Configure LabVIEW 2009 to Communicate with Acromag BusWorks and EtherStax Modbus I/O Modules Via an OPC Server Application NoteIntroduction National Instruments LabVIEW can be used to monitor and control Acromag Busworks and Etherstax Modbus I/O Modules via an OPC server. A separate application note, Configuring Kepware KEPServerEX 5.0 for Communications with Acromag Busworks and Etherstax Modbus I/O Modules, outlines configuration of a KEPServerEX OPC server. This document focuses on setting up controls and...How to Configure Omron CJ2H PLC's with Ethernet/IP for Use with Acromag Ethernet/IP Remote I/O Application NotePurpose: Acromag Ethernet/IP I/O with Omron CJ2H PLC’s This document walks the user through the configuration of the Cx-One Network Configurator software that is used in conjunction with Omron CJ2H PLC’s. It is assumed that the user has a working knowledge of the PLC and Cx-One software. Configuring the CxOne “Network Configurator” Start the Cx-One...How to Communicate to Acromag Series 9xxEN-60xx Ethernet Modules using PCCC from Compact Logix Devices Application NotePCCC Messaging with CompactLogix This document illustrates a procedure for configuring PCCC message commands for Acromag Series 9xxEN Ethernet/IP modules using ladder logic programming and a Compact Logix Controller. It is assumed that the user has a working knowledge of ladder logic programming, the RSLogix5000 software, and the Compact Logix hardware. Configuring PCCC Messaging Using...How to Communicate to Ethernet Modules from Legacy Allen Bradley or Rockwell Automation Devices Application NoteThis document illustrates a procedure for configuring message commands for Acromag Series 9xxEN Ethernet/IP modules using ladder logic programming and an SLC5\05 Programmable Logic Controller. It is assumed that the user has a working knowledge of ladder logic programming, the RSLogix500 software, and the SLC 5\05 hardware. Setup of PCCC Communication to Series 9xxEN-60xx I/O...How to Configure the Wonderware MBENET I/O Server to Communicate with the Acromag 9xxEN Ethernet Modules Application NoteWonderware MBENET The purpose of this document is to provide a procedure for configuring MBENET I/O Server (ie: Modicon Ethernet I/O Server) to communicate with an Acromag Series 9xxEN Ethernet I/O Module. It is assumed that the user has a working knowledge of Wonderware and how to link the Wonderware application to the Wonderware I/O... -
Specs & Data Sheets
Specifications
Manuals
Brochure
-
Software
-
Accessories
-
20RM-16-DIN: 19” rack-mount kit with DIN rail
- 19" rack-mount kit with DIN rail
$185Select options -
4001 Serial Cables
5-foot ribbon cable, DB25 male and 26-pin female IDC connectors, for 3B/5B backpanel to Ethernet I/O module connection$95Select options -
5035 Series: Ethernet Cables
- Ethernet straight cable, CAT5
- Ethernet crossover cable, CAT5E
- Low EMI Double-Shielded Ethernet Patch Cable
$40 – $115Select options -
900EN: 5-Port Ethernet Switch
- 10/100Mbps
- 15 to 36V DC power supply required
- Five shielded RJ-45 sockets, 8-pin, 10Base-T / 100Base-TX
$340Select options -
AMTN, AMTX: ActiveX / .NET Controls for Modbus I/O
- Modbus/TCP or Modbus/RTU
- These ActiveX / .NET software controls provide a fast, easy way to communicate with any Modbus slave devices connected to your PC.
- Get your Visual Basic, Visual C, .NET, Excel, or other compatible applications talking Modbus protocol within minutes.
$260 – $350Select options -
IMC-100A: 10/100BaseTX to 100BaseFX Industrial Media Converter
- UTP to Fiber Media Converter
- RJ45 Port Supports Auto MDI/MDI-X Function
$240Select options -
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
$95 – $245Select options -
Terminal Block Replacements
- Simplifies wiring connections on Acromag I/O Modules
- Barrier strip or spring clamp terminal block kits
- Provide safe and secure wiring connections
$30 – $40Select options -
USB-to-Ethernet Adapter
Simplifies configuration of Acromag Ethernet I/O Modules Prevents disruption of existing LANs This device is a USB-to-Ethernet adapter that you can use to communicate with any Acromag Ethernet I/O product for the purpose of setup and re-configuration for your application. It is recommended for initial communication with Acromag Ethernet devices so that you do not have to disrupt your existing network connection.$80Select options
-
-
Additional information
Additional information
Weight 10 oz Dimensions 4.5 × 1.5 × 5 in Product Number 981EN-6012: Ethernet/IP; 12 input channels, 982EN-6012: Ethernet/IP; 12 output channels, 983EN-6012: Ethernet/IP; 12 input/output channels, 981EN-4012: Modbus TCP/IP; 12 input channels, 982EN-4012: Modbus TCP/IP; 12 output channels, i2o capability, 983EN-4012: Modbus TCP/IP; 12 input/output channels, i2o capability
Communication Ethernet/IP, i2o Peer-to-Peer, Modbus TCP/IP
Configuration Built-in Web pages
Product Series BusWorks 900EN Series
Power DC Power
Please login to submit this form.