XT1220: 8-Channel Differential Analog Voltage Input Module
Product short description:
- ±5V, ±10V, 0-5V, 0-10V Input
- 8 analog differential voltage input channels
- 12 to 32V DC Power (2.8W)
- Modbus TCP/IP, Ethernet/IP, Profinet
- i2o® peer-to-peer available for Modbus TCP/IP only
The XT1220 offers an isolated Ethernet network interface for up to eight differential voltage input channels.
- Description
- Features & Benefits
- Tech Papers
- Specs & Data Sheets
- Software
- Accessories
- Additional information
The XT1220 offers an isolated Ethernet network interface for up to eight differential voltage input channels. Isolated differential inputs deliver better measurements, superior noise rejection, and eliminate the need for signal isolators.
Rugged construction, high density design, and easy USB-to-PC/Windows setup combine for a very effective and reliable module. These units are ideal for remote monitoring, distributed control, or SCADA applications.
Input Ranges: ±5V, ±10V, 0 to 5V, 0 to 10V
Ethernet Communication:
Modbus TCP/IP, i2o® peer-to-peer available for Modbus TCP/IP only
Ethernet/IP
Profinet
10/100Base-T(X)
PriorityChannel™ device determinism
Power Requirement: 12 to 32V DC (2.8W)
Performance Specifications
IMPORTANT: To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends use of the USB-ISOLATOR when configuring an XT1000 I/O module.
USB Interface
USB Connector:
Type: USB Mini-B type socket, 5-pin
Data Rate: 12Mbps. USB v1.1 and 2.0 compatible
Cable Length: 5.0 meters maximum
USB Transient Protection: Transient voltage suppression on power and data lines
Driver: Not required. Uses Windows (HID) drivers
Input
Accuracy: ±0.05% of span, typical for nominal input ranges
Analog to Digital Converter (A/D): 16-bit Σ-Δ converter. 334.85uV/bit resolution
Noise Rejection: Better than -110dB @ 60Hz
Input Filter Bandwidth: -3dB at 25KHz, typical
Input Conversion Rate: 10ms for all 8 input channels
Input Impedance: 100.2k ohms
Ethernet Communication
Protocols:
Modbus TCP/IP, i2o® peer-to-peer available for Modbus TCP/IP only
Ethernet/IP
or Profinet, depending on model number
Ethernet Communication Controller: Innovasic RapID™ Platform with PriorityChannel™ for determinism at the device regardless of network load
Modbus TCP/IP (slave): Port 502 reserved. Supports up to 10 sockets
i2o Peer-to-Peer (master/slave): Can map each of 8 analog input channels separately to output channels. Timed (1-65535 sec) or percent-of-change updates. Supports GPRS/GSM systems
Ethernet/IP (adapter): Supports 10 connections. EDS file on website
Profinet (server): Supports 1 connection. GSDML file on website
Connectors: Two shielded 8-pin RJ-45 sockets, 10BaseT/100BaseTX
Wiring: Auto-crossover for MDI or MDI-X
IP Address: User-configurable. 192.168.1.100 default IP address
Data Rate: Auto-negotiated, 10Mbps or 100Mbps
Compliance: IEEE 802.3, 802.3u, 802.3x
Environmental
Operating temperature: -40 to 70°C (-40 to 158°F)
Storage temperature: -40 to 85°C (-40 to 185°F)
Relative humidity: 5 to 95% non-condensing
MTBF:
486,024 hrs. at 25°C
365,543 hrs. at 40°C
Power Requirement: 12 to 32V DC, 2.8W maximum (116mA maximum @ 24V)
Isolation:
4-way isolation between I/O channels, network (each port), and power
Peak: 1500V AC, ANSI/ISA-82.01-1988
Continuous: 250V AC, 354V DC
Shock and Vibration Immunity:
Vibration: 4g, per IEC 60068-2-64
Shock: 25g, per IEC 60068-2-27
Electromagnetic Compatibility (EMC) Compliance:
Radiated Emissions: BS EN 61000-6-4, CISPR 16
RFI: BS EN 61000-6-2, IEC 61000-4-3
Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6
ESD: BS EN 61000-6-2, IEC 61000-4-2
EFT: BS EN 61000-6-2, IEC 61000-4-4
Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5
Approvals:
CE compliant. UL/cUL Class I; Div. 2 Zone 2. ATEX Cert. II 3 G Ex nA IIC T4 Gc -40°C < Ta < +80°C
Physical
General: General purpose plastic enclosure for mounting on 35mm “T-type” DIN rail
Case Material: Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General purpose NEMA Type 1 enclosure
Circuit Board: Military grade fire-retardant epoxy glass (IPC-4101/98)
I/O Connectors: Removable plug-in type terminal blocks rated for 12A/250V; AWG #26-12, stranded/solid copper wire
Dimensions:
Width = 22.5mm (0.9 inches)
Length = 114.5mm (4.51 inches)
Depth = 99.0mm (3.90 inches)
Shipping Weight: 0.5 pounds (0.22 Kg) packed
- i2o® peer-to-peer available for Modbus TCP/IP only
- i2o® peer-to-peer updates based on change-of-state and/or timed updates
- Easy setup with Windows software via USB
- High input impendance (100K ohms) reduces loading on voltage loops
- User-configurable sample averaging (1-200) on a per-channel basis
- 10ms network updates for all 8 input channels
- High-resolution 16-bit Σ∆ A/D converter ensures precise, high accuracy measurements
- High-Density 22.5mm wide package with pluggable, front-facing terminals
- Dual Ethernet 10/100 ports (auto-negotiation) reduce switch port requirements
- 1500V AC isolation (between I/O, power, and network ports) and surge/transient protection
- Supports bussed/rail and redundant power
- -40°C to 70°C wide temperature operation
- Withstands 25g shock and 4g vibration
- CE compliant. UL/cUL Class 1 Div 2 Zone 2 approvals.
- ATEX Certified
Specifications
Manuals
Brochure
-
4001 Serial Cables
5-foot ribbon cable, DB25 male and 26-pin female IDC connectors, for 3B/5B backpanel to Ethernet I/O module connection$95Select options -
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
$50Select options -
5035 Series: Ethernet Cables
- Ethernet straight cable, CAT5
- Ethernet crossover cable, CAT5E
- Low EMI Double-Shielded Ethernet Patch Cable
$40 – $115Select options -
900EN: 5-Port Ethernet Switch
- 10/100Mbps
- 15 to 36V DC power supply required
- Five shielded RJ-45 sockets, 8-pin, 10Base-T / 100Base-TX
$340Select options -
AMTN, AMTX: ActiveX / .NET Controls for Modbus I/O
- Modbus/TCP or Modbus/RTU
- These ActiveX / .NET software controls provide a fast, easy way to communicate with any Modbus slave devices connected to your PC.
- Get your Visual Basic, Visual C, .NET, Excel, or other compatible applications talking Modbus protocol within minutes.
$260 – $350Select options -
BusWorks XT Connector Kit
DIN rail bus power/excitation connector kit. Includes one DIN rail bus connector (1005-070), one left-side female connector terminal block (1005-220) and one right side male connector terminal block (1005-221).$30Select options -
IMC-100A: 10/100BaseTX to 100BaseFX Industrial Media Converter
- UTP to Fiber Media Converter
- RJ45 Port Supports Auto MDI/MDI-X Function
$240Select options -
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
$95 – $245Select options -
Terminal Block Replacements
- Simplifies wiring connections on Acromag I/O Modules
- Barrier strip or spring clamp terminal block kits
- Provide safe and secure wiring connections
$30 – $40Select options -
USB Isolator
- USB-powered, USB 2.0 and 1.1 compatible
- 1500V AC / 2100V DC isolation
- No drivers required
$110Select options -
USB-to-Ethernet Adapter
Simplifies configuration of Acromag Ethernet I/O Modules Prevents disruption of existing LANs This device is a USB-to-Ethernet adapter that you can use to communicate with any Acromag Ethernet I/O product for the purpose of setup and re-configuration for your application. It is recommended for initial communication with Acromag Ethernet devices so that you do not have to disrupt your existing network connection.$80Select options -
XT-SIP: Software Interface Package
- Software Interface Package for BusWorks XT Series Ethernet I/O modules.
- Includes configuration software CD-ROM (XT-CONFIG)
- Isolator (USB-Isolator)
- Ethernet cable (5035-360)
- Two USB cables (4001-112, 4001-113)
- Easy setup and digital calibration via USB with Windows configuration software
- Download software only from the Software Tab below
$185Select options
Additional information
Weight | 16 oz |
---|---|
Dimensions | 12 × 13 × 5 in |
Part Number | XT1221-000: Modbus/TCP and i2o protocol, XT1222-000: Ethernet/IP protocol, XT1223-000: Profinet protocol |
Product Series | BusWorks XT Series |
Communication | Ethernet/IP, i2o Peer-to-Peer, Modbus TCP/IP, Profinet |
Configuration | USB Configuration, Windows Software Configuration |
-
Description
The XT1220 offers an isolated Ethernet network interface for up to eight differential voltage input channels. Isolated differential inputs deliver better measurements, superior noise rejection, and eliminate the need for signal isolators.
Rugged construction, high density design, and easy USB-to-PC/Windows setup combine for a very effective and reliable module. These units are ideal for remote monitoring, distributed control, or SCADA applications.
Input Ranges: ±5V, ±10V, 0 to 5V, 0 to 10V
Ethernet Communication:
Modbus TCP/IP, i2o® peer-to-peer available for Modbus TCP/IP only
Ethernet/IP
Profinet
10/100Base-T(X)
PriorityChannel™ device determinism
Power Requirement: 12 to 32V DC (2.8W)Performance Specifications
IMPORTANT: To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends use of the USB-ISOLATOR when configuring an XT1000 I/O module.
USB Interface
USB Connector:
Type: USB Mini-B type socket, 5-pin
Data Rate: 12Mbps. USB v1.1 and 2.0 compatible
Cable Length: 5.0 meters maximum
USB Transient Protection: Transient voltage suppression on power and data lines
Driver: Not required. Uses Windows (HID) driversInput
Accuracy: ±0.05% of span, typical for nominal input ranges
Analog to Digital Converter (A/D): 16-bit Σ-Δ converter. 334.85uV/bit resolution
Noise Rejection: Better than -110dB @ 60Hz
Input Filter Bandwidth: -3dB at 25KHz, typical
Input Conversion Rate: 10ms for all 8 input channels
Input Impedance: 100.2k ohmsEthernet Communication
Protocols:
Modbus TCP/IP, i2o® peer-to-peer available for Modbus TCP/IP only
Ethernet/IP
or Profinet, depending on model number
Ethernet Communication Controller: Innovasic RapID™ Platform with PriorityChannel™ for determinism at the device regardless of network load
Modbus TCP/IP (slave): Port 502 reserved. Supports up to 10 sockets
i2o Peer-to-Peer (master/slave): Can map each of 8 analog input channels separately to output channels. Timed (1-65535 sec) or percent-of-change updates. Supports GPRS/GSM systems
Ethernet/IP (adapter): Supports 10 connections. EDS file on website
Profinet (server): Supports 1 connection. GSDML file on website
Connectors: Two shielded 8-pin RJ-45 sockets, 10BaseT/100BaseTX
Wiring: Auto-crossover for MDI or MDI-X
IP Address: User-configurable. 192.168.1.100 default IP address
Data Rate: Auto-negotiated, 10Mbps or 100Mbps
Compliance: IEEE 802.3, 802.3u, 802.3xEnvironmental
Operating temperature: -40 to 70°C (-40 to 158°F)
Storage temperature: -40 to 85°C (-40 to 185°F)
Relative humidity: 5 to 95% non-condensing
MTBF:
486,024 hrs. at 25°C
365,543 hrs. at 40°C
Power Requirement: 12 to 32V DC, 2.8W maximum (116mA maximum @ 24V)
Isolation:
4-way isolation between I/O channels, network (each port), and power
Peak: 1500V AC, ANSI/ISA-82.01-1988
Continuous: 250V AC, 354V DC
Shock and Vibration Immunity:
Vibration: 4g, per IEC 60068-2-64
Shock: 25g, per IEC 60068-2-27
Electromagnetic Compatibility (EMC) Compliance:
Radiated Emissions: BS EN 61000-6-4, CISPR 16
RFI: BS EN 61000-6-2, IEC 61000-4-3
Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6
ESD: BS EN 61000-6-2, IEC 61000-4-2
EFT: BS EN 61000-6-2, IEC 61000-4-4
Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5
Approvals:
CE compliant. UL/cUL Class I; Div. 2 Zone 2. ATEX Cert. II 3 G Ex nA IIC T4 Gc -40°C < Ta < +80°CPhysical
General: General purpose plastic enclosure for mounting on 35mm “T-type” DIN rail
Case Material: Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General purpose NEMA Type 1 enclosure
Circuit Board: Military grade fire-retardant epoxy glass (IPC-4101/98)
I/O Connectors: Removable plug-in type terminal blocks rated for 12A/250V; AWG #26-12, stranded/solid copper wire
Dimensions:
Width = 22.5mm (0.9 inches)
Length = 114.5mm (4.51 inches)
Depth = 99.0mm (3.90 inches)
Shipping Weight: 0.5 pounds (0.22 Kg) packed -
Features & Benefits
- i2o® peer-to-peer available for Modbus TCP/IP only
- i2o® peer-to-peer updates based on change-of-state and/or timed updates
- Easy setup with Windows software via USB
- High input impendance (100K ohms) reduces loading on voltage loops
- User-configurable sample averaging (1-200) on a per-channel basis
- 10ms network updates for all 8 input channels
- High-resolution 16-bit Σ∆ A/D converter ensures precise, high accuracy measurements
- High-Density 22.5mm wide package with pluggable, front-facing terminals
- Dual Ethernet 10/100 ports (auto-negotiation) reduce switch port requirements
- 1500V AC isolation (between I/O, power, and network ports) and surge/transient protection
- Supports bussed/rail and redundant power
- -40°C to 70°C wide temperature operation
- Withstands 25g shock and 4g vibration
- CE compliant. UL/cUL Class 1 Div 2 Zone 2 approvals.
- ATEX Certified
-
Tech Papers
How to Monitor Gensets in Standby Mode to Ensure Reliable Backup Power Application NoteDefining the Problem: Gensets typically include control systems that monitor and control the engine functions. Primary functions are start/stop control, engine speed, operating parameters, and protection/shutdown. As back-up systems, gensets may operate less than 100 hours per year. While in the standby mode, it is critical to monitor and maintain the genset system to prevent...How to Connect to Acromag Ethernet I/O Devices Application NoteGetting Connected to Acromag Ethernet I/O Devices These instructions summarize the basic steps you will have to take in order to initially connect an Acromag Ethernet I/O product to your Personal Computer (PC) or laptop. To connect an Ethernet device to your PC, consult with your network administrator and either temporarily change the TCP/IP configuration...How to Communicate with Ethernet XT Profinet from Siemens S7-1200 PLC Application NoteEthernetXT Profinet and Siemens S7-1200 When setting up a Profinet network, Profinet controllers are programmed with a special Profinet Configuration tool, like the Step7 from Siemens. This document illustrates an example procedure for configuring communications between Acromag BusWorks® Series Profinet modules and a Siemens S7-1200 Programmable Controller. It is assumed that the user has a...WHITEPAPER: How to Connect to an Ethernet Device for Communication (Log in to view the file)How to Connect to an Ethernet Device for Communication To connect and communicate to an Ethernet device like an Acromag Ethernet module, you have three potential connection scenarios: Direct connect your Ethernet device to your computer – Easiest but the most restrictive, as it dominates the use of your Ethernet port and may temporarily take...WHITEPAPER: How to Remotely Access Ethernet I/O Over the Internet (Log in to view the file)This white paper details the steps needed to access your I/O module remotely over the internet. This can be done with Ethernet-enabled I/O modules that have the capability to display built-in webpage-based output monitoring. In other words, if your I/O module can serve a webpage over Ethernet, and the network it is connected to has...How to Communicate to Acromag Series Ethernet Modules from Red Lion HMIs Application NoteRed Lion HMIs This document illustrates a procedure for configuring message commands for Acromag Ethernet modules using the Red Lion Crimson 2.0 Software. It is assumed that the user has a working knowledge of the Crimson 2.0 software, as well as a Red Lion HMI. Setting up Communications From a new or existing project, double... -
Specs & Data Sheets
Specifications
Manuals
Brochure
-
Software
Ethernet XT Series Configuration Software (Log in to download the file)Ethernet IP EDS For XTxxx2-000 Modules (Log in to download the file)Profinet GSDML Files for XTxxx3-000 Modules (Log in to download the file)ESW-MBLIB-DEMO (Log in to download the file)AMTN-DEMO (Log in to download the file)ATMX Demo Software (Log in to download the file) -
Accessories
-
4001 Serial Cables
5-foot ribbon cable, DB25 male and 26-pin female IDC connectors, for 3B/5B backpanel to Ethernet I/O module connection$95Select options -
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
$50Select options -
5035 Series: Ethernet Cables
- Ethernet straight cable, CAT5
- Ethernet crossover cable, CAT5E
- Low EMI Double-Shielded Ethernet Patch Cable
$40 – $115Select options -
900EN: 5-Port Ethernet Switch
- 10/100Mbps
- 15 to 36V DC power supply required
- Five shielded RJ-45 sockets, 8-pin, 10Base-T / 100Base-TX
$340Select options -
AMTN, AMTX: ActiveX / .NET Controls for Modbus I/O
- Modbus/TCP or Modbus/RTU
- These ActiveX / .NET software controls provide a fast, easy way to communicate with any Modbus slave devices connected to your PC.
- Get your Visual Basic, Visual C, .NET, Excel, or other compatible applications talking Modbus protocol within minutes.
$260 – $350Select options -
BusWorks XT Connector Kit
DIN rail bus power/excitation connector kit. Includes one DIN rail bus connector (1005-070), one left-side female connector terminal block (1005-220) and one right side male connector terminal block (1005-221).$30Select options -
IMC-100A: 10/100BaseTX to 100BaseFX Industrial Media Converter
- UTP to Fiber Media Converter
- RJ45 Port Supports Auto MDI/MDI-X Function
$240Select options -
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
$95 – $245Select options -
Terminal Block Replacements
- Simplifies wiring connections on Acromag I/O Modules
- Barrier strip or spring clamp terminal block kits
- Provide safe and secure wiring connections
$30 – $40Select options -
USB Isolator
- USB-powered, USB 2.0 and 1.1 compatible
- 1500V AC / 2100V DC isolation
- No drivers required
$110Select options -
USB-to-Ethernet Adapter
Simplifies configuration of Acromag Ethernet I/O Modules Prevents disruption of existing LANs This device is a USB-to-Ethernet adapter that you can use to communicate with any Acromag Ethernet I/O product for the purpose of setup and re-configuration for your application. It is recommended for initial communication with Acromag Ethernet devices so that you do not have to disrupt your existing network connection.$80Select options -
XT-SIP: Software Interface Package
- Software Interface Package for BusWorks XT Series Ethernet I/O modules.
- Includes configuration software CD-ROM (XT-CONFIG)
- Isolator (USB-Isolator)
- Ethernet cable (5035-360)
- Two USB cables (4001-112, 4001-113)
- Easy setup and digital calibration via USB with Windows configuration software
- Download software only from the Software Tab below
$185Select options
-
Additional information
Additional information
Weight 16 oz Dimensions 12 × 13 × 5 in Part Number XT1221-000: Modbus/TCP and i2o protocol, XT1222-000: Ethernet/IP protocol, XT1223-000: Profinet protocol
Product Series BusWorks XT Series
Communication Ethernet/IP, i2o Peer-to-Peer, Modbus TCP/IP, Profinet
Configuration USB Configuration, Windows Software Configuration
Please login to submit this form.