Product short description:
  • 4 or 6-channel RTD/resistance input
  • Ethernet/IP, Modbus TcP/IP, i2o peer-to-peer messaging
  • Input Ranges: Input ranges are selectable for a 3-channel group.
  • RTD: 2-wire and 3-wire RTDs are supported. Platinum 100 ohm (alpha = 1.3850 or 1.3911)
    Nickel 120 ohm; Copper 10 ohm
  • Resistance: 0 to 500 ohms
  • Network Communication: EtherNet/IP or Modbus TCP/IP 10/100Mbps with automatic data rate negotiation
  • Power Requirement: 15 to 36V DC supply (2 Watts) required
  • Approvals CE/ATEX marked. UL, cUL listed, Class I; Div. 2; Groups A, B, C, D. EtherNet/IP, Modbus/TCP conformance tested.
RSS
FACEBOOK
FACEBOOK
TWITTER
Visit Us
LINKEDIN

These modules provide an isolated Ethernet network interface for up to six input channels. Multi-range inputs accept signals from a variety of sensors and devices. High-resolution, low noise, A/D converters deliver high accuracy and reliability. 3-way isolation further improves the system performance.

Input Ranges: Input ranges are selectable for a 3-channel group.

RTD: 2-wire and 3-wire RTDs are supported. Platinum 100 ohm (alpha = 1.3850 or 1.3911)
Nickel 120 ohm
Copper 10 ohm

Resistance: 0 to 500 ohms

Network Communication: EtherNet/IP or Modbus TCP/IP 10/100Mbps with automatic data rate negotiation

Power Requirement: 15 to 36V DC supply (2 Watts) required

Approvals CE/ATEX marked. UL, cUL listed, Class I; Div. 2; Groups A, B, C, D. EtherNet/IP, Modbus/TCP conformance tested.

Performance Specifications

Input

Accuracy Input Type Input RangeAccuracy (typical)

Pt 100 ohm; -200 to 850°C      ±0.25°C  (typical)

Ni 120 ohm; -80 to 320°C       ±0.25°C  (typical)

Cu 10 ohm; -200 to 260°C       ±1.25°C (typical)

Resistance; 0 to 500 ohms      ±0.05 ohms (typical)

RTD Break Detection
Upscale or downscale selection applies to all channels.

Noise Rejection
Normal Mode: Better than 40dB @ 60Hz.
Common Mode: Better than 130dB @ 60Hz.

Input Filter Bandwidth -3dB at 3Hz, typical.

Input Conversion Rate 80mS per channel.

Excitation Current 1mA DC typical, all RTD types.

Environmental

Ambient Temperature and Humidity Operating: -25 to 70°C (-13 to 158°F).
Storage: -40 to 85°C (-40 to 185°F).
Relative humidity: 5 to 95%, non-condensing.

Isolation 1500V AC for 60 seconds or 250V AC continuous. 3-way isolation between I/O, network, and power. Inputs share a common.

Communication

Connector: Shielded RJ-45 sockets, 8-pin, 10BaseT/100BaseTX.

Wiring: Wired MDI. 9xxEN I/O modules do NOT support autocrossover. 900EN switch supports auto-crossover.

Protocol: EtherNet/IP or Modbus TCP/IP with web browser configuration. EtherNet/IP supports PCCC object for communication with legacy PLCs (e.g. SLC505).

IP Address: Default static IP address is 128.1.1.100.

Port:
Ethernet Modbus TCP/IP models (9xxEN-4xxx): Up to 10 Modbus TCP/IP sockets supported.
EtherNet/IP models (9xxEN-6xxx): Up to 10 EtherNet/IP sockets and 1 Modbus TCP/IP socket.

Data Rate: Auto-sensed, 10Mbps or 100Mbps.

Duplex: Auto-negotiated, full or half-duplex.

Compliance: IEEE 802.3, 802.3u, 802.3x, Ethernet II.

Configuration: Web page for configuration and control is built-in with Ethernet access via a standard web browser.

Communication Distance: Distance between network devices is generally limited to 100 meters using recommended cable. Distances may be extended using hubs and switches.

Address: IP address is automatically acquired at startup. Unit may be configured to retrieve this address from the network server using BOOTP (Bootstrap Protocol), or via DHCP (Dynamic Configuration Protocol). A static IP address is also user-programmable. A default toggle switch sets the static IP address to the default factory address of 128.1.1.100 for initial configuration.

Environmental

Isolation: I/O channel, power, and network circuits are isolated from each other for common-mode voltages up to 250VAC, or 354V DC off DC power ground, on a continuous basis (will withstand 1500VAC dielectric strength test for one minute without breakdown). Complies with test requirements of ANSI/ISA-82.01- 1988 for voltage rating specified.

Electromagnetic Compatibility (EMC)

Immunity per European Norm EN50082-1. Emissions per European Norm EN50081-1.

Electrostatic Discharge (ESD) Immunity Per EN61000-4-2.

Radiated Field Immunity (RFI) Per EN61000-4-3 and ENV50204.

Electrical Fast Transient Immunity (EFT) Per EN61000-4-4.

Conducted RF Immunity (CRFI) Per EN61000-4-6.

Surge Immunity Per EN61000-4-5.

Radiated Frequency Emissions Per EN55022 Class B.

  • Configurable from standard web browser
  • EtherNet/IP™ or Ethernet ModbusTCP/IP communication with automatic 10/100Mbps data rate negotiation
  • 6-input stand-alone module has much lower start-up cost than multi-piece block I/O systems
  • i2o function enables direct input-to-output communication without a network controller
  • Versatile RTD or ohmic inputs support a wide variety of industrial sensors and devices
  • RTD break detection (upscale or downscale) identifies sensor wiring failures
  • High-resolution 16-bit sigma delta A/D converters ensure precise, high accuracy measurements
  • Compact packaging with pluggable terminals saves space and simplifies wiring
  • Wide operational temperature range permits installation in extreme environments; -25°C to 70°C (-13° to 158°F)
  • Approvals: CE/ATEX marked; UL, cUL listed, Class 1 Div 2 Groups A, B, C, D; EtherNet/IP, Modbus/TCP conformance tested.

Specs & Catalogs

Manuals

966EN-4xxx User Manual (Log in to download the file)

966EN-6xxx User Manual (Log in to download the file)

Additional information

Weight 10 oz
Dimensions 4.5 × 1.5 × 5 in
Part Number

966EN-4004: Modbus TCP/IP, 4 channel, 966EN-4006: Modubs TCP/IP, 6 channel, 966EN-6004: Ethernet/IP, 4 channel, 966EN-6006: Ethernet/IP, 6 channel

Communication

Ethernet/IP, i2o Peer-to-Peer, Modbus TCP/IP

Product Series

BusWorks 900EN Series

Configuration

Built-in Web pages

  • Description

    These modules provide an isolated Ethernet network interface for up to six input channels. Multi-range inputs accept signals from a variety of sensors and devices. High-resolution, low noise, A/D converters deliver high accuracy and reliability. 3-way isolation further improves the system performance.

    Input Ranges: Input ranges are selectable for a 3-channel group.

    RTD: 2-wire and 3-wire RTDs are supported. Platinum 100 ohm (alpha = 1.3850 or 1.3911)
    Nickel 120 ohm
    Copper 10 ohm

    Resistance: 0 to 500 ohms

    Network Communication: EtherNet/IP or Modbus TCP/IP 10/100Mbps with automatic data rate negotiation

    Power Requirement: 15 to 36V DC supply (2 Watts) required

    Approvals CE/ATEX marked. UL, cUL listed, Class I; Div. 2; Groups A, B, C, D. EtherNet/IP, Modbus/TCP conformance tested.

    Performance Specifications

    Input

    Accuracy Input Type Input RangeAccuracy (typical)

    Pt 100 ohm; -200 to 850°C      ±0.25°C  (typical)

    Ni 120 ohm; -80 to 320°C       ±0.25°C  (typical)

    Cu 10 ohm; -200 to 260°C       ±1.25°C (typical)

    Resistance; 0 to 500 ohms      ±0.05 ohms (typical)

    RTD Break Detection
    Upscale or downscale selection applies to all channels.

    Noise Rejection
    Normal Mode: Better than 40dB @ 60Hz.
    Common Mode: Better than 130dB @ 60Hz.

    Input Filter Bandwidth -3dB at 3Hz, typical.

    Input Conversion Rate 80mS per channel.

    Excitation Current 1mA DC typical, all RTD types.

    Environmental

    Ambient Temperature and Humidity Operating: -25 to 70°C (-13 to 158°F).
    Storage: -40 to 85°C (-40 to 185°F).
    Relative humidity: 5 to 95%, non-condensing.

    Isolation 1500V AC for 60 seconds or 250V AC continuous. 3-way isolation between I/O, network, and power. Inputs share a common.

    Communication

    Connector: Shielded RJ-45 sockets, 8-pin, 10BaseT/100BaseTX.

    Wiring: Wired MDI. 9xxEN I/O modules do NOT support autocrossover. 900EN switch supports auto-crossover.

    Protocol: EtherNet/IP or Modbus TCP/IP with web browser configuration. EtherNet/IP supports PCCC object for communication with legacy PLCs (e.g. SLC505).

    IP Address: Default static IP address is 128.1.1.100.

    Port:
    Ethernet Modbus TCP/IP models (9xxEN-4xxx): Up to 10 Modbus TCP/IP sockets supported.
    EtherNet/IP models (9xxEN-6xxx): Up to 10 EtherNet/IP sockets and 1 Modbus TCP/IP socket.

    Data Rate: Auto-sensed, 10Mbps or 100Mbps.

    Duplex: Auto-negotiated, full or half-duplex.

    Compliance: IEEE 802.3, 802.3u, 802.3x, Ethernet II.

    Configuration: Web page for configuration and control is built-in with Ethernet access via a standard web browser.

    Communication Distance: Distance between network devices is generally limited to 100 meters using recommended cable. Distances may be extended using hubs and switches.

    Address: IP address is automatically acquired at startup. Unit may be configured to retrieve this address from the network server using BOOTP (Bootstrap Protocol), or via DHCP (Dynamic Configuration Protocol). A static IP address is also user-programmable. A default toggle switch sets the static IP address to the default factory address of 128.1.1.100 for initial configuration.

    Environmental

    Isolation: I/O channel, power, and network circuits are isolated from each other for common-mode voltages up to 250VAC, or 354V DC off DC power ground, on a continuous basis (will withstand 1500VAC dielectric strength test for one minute without breakdown). Complies with test requirements of ANSI/ISA-82.01- 1988 for voltage rating specified.

    Electromagnetic Compatibility (EMC)

    Immunity per European Norm EN50082-1. Emissions per European Norm EN50081-1.

    Electrostatic Discharge (ESD) Immunity Per EN61000-4-2.

    Radiated Field Immunity (RFI) Per EN61000-4-3 and ENV50204.

    Electrical Fast Transient Immunity (EFT) Per EN61000-4-4.

    Conducted RF Immunity (CRFI) Per EN61000-4-6.

    Surge Immunity Per EN61000-4-5.

    Radiated Frequency Emissions Per EN55022 Class B.

  • Features & Benefits

    • Configurable from standard web browser
    • EtherNet/IP™ or Ethernet ModbusTCP/IP communication with automatic 10/100Mbps data rate negotiation
    • 6-input stand-alone module has much lower start-up cost than multi-piece block I/O systems
    • i2o function enables direct input-to-output communication without a network controller
    • Versatile RTD or ohmic inputs support a wide variety of industrial sensors and devices
    • RTD break detection (upscale or downscale) identifies sensor wiring failures
    • High-resolution 16-bit sigma delta A/D converters ensure precise, high accuracy measurements
    • Compact packaging with pluggable terminals saves space and simplifies wiring
    • Wide operational temperature range permits installation in extreme environments; -25°C to 70°C (-13° to 158°F)
    • Approvals: CE/ATEX marked; UL, cUL listed, Class 1 Div 2 Groups A, B, C, D; EtherNet/IP, Modbus/TCP conformance tested.
  • Specs & Data Sheets

    Specs & Catalogs

    Manuals

    966EN-4xxx User Manual (Log in to download the file)

    966EN-6xxx User Manual (Log in to download the file)

  • Additional information

    Additional information

    Weight 10 oz
    Dimensions 4.5 × 1.5 × 5 in
    Part Number

    966EN-4004: Modbus TCP/IP, 4 channel, 966EN-4006: Modubs TCP/IP, 6 channel, 966EN-6004: Ethernet/IP, 4 channel, 966EN-6006: Ethernet/IP, 6 channel

    Communication

    Ethernet/IP, i2o Peer-to-Peer, Modbus TCP/IP

    Product Series

    BusWorks 900EN Series

    Configuration

    Built-in Web pages