Click to zoom
$580$685
Clear
Product short description:
  •  4 or 6-channel thermocouple/millivolt input
  • Ethernet/IP, Modbus TCP/IP, i2o peer-to-peer messaging
  • Input Ranges: Ranges are selectable for a 3-channel group.
  • Thermocouple (user-selectable type) Type J, K, T, R, S, E, B, or N.
  • DC Millivolts (user-selectable range) ±100mV or ±1V DC.
  • Network Communication: EtherNet/IP or Modbus TCP/IP 10/100Mbps with automatic data rate negotiation.
  • Power Requirement: 15 to 36V DC supply (2 Watts) required.
  • Approvals: CE/ATEX marked.  UL, cUL listed, Class I; Div. 2; Groups A, B, C, D. EtherNet/IP, Modbus/TCP conformance tested.
RSS
FACEBOOK
FACEBOOK
TWITTER
Visit Us
LINKEDIN

These modules provide an isolated Ethernet network interface for up to six input channels. Differential inputs eliminate ground noise and each terminal block includes a cold junction compensation (CJC) sensor for more precise temperature measurements. Multi-range inputs accept signals from a variety of sensors and devices. High-resolution, low noise, A/D converters deliver high accuracy and reliability.

Input Ranges
Ranges are selectable for a 3-channel group.

Thermocouple (user-selectable type) Type J, K, T, R, S, E, B, or N.

DC Millivolts (user-selectable range) ±100mV or ±1V DC.

Network Communication
EtherNet/IP or Modbus TCP/IP 10/100Mbps with automatic data rate negotiation.

Power Requirement
15 to 36V DC supply (2 Watts) required.

Approvals
CE/ATEX marked.  UL, cUL listed, Class I; Div. 2; Groups A, B, C, D. EtherNet/IP, Modbus/TCP conformance tested.

Performance Specifications 
Input


Accuracy
Type J:  -210 to 760°C input range;  ±0.5°C Accuracy (typical).

Type K: -200 to 1372°C input range; ±0.5°C Accuracy (typical).

Type T: -260 to 400°C  input range; ±0.5°C Accuracy (typical).

Type R: -50 to 1768°C input range;  ±1.0°C Accuracy (typical).

Type S: -50 to 1768°C input range; ±1.0°C Accuracy (typical).

Type E: -200 to 1000°C input range;  ±0.5°C Accuracy (typical).

Type B: 260 to 1820°C input range; ±1.0°C Accuracy (typical).

Type N: -230 to -170°C input range;  ±1.0°C Accuracy (typical).

Type N: -170 to 1300°C input range;  ±0.5°C). Accuracy (typical).

Voltage: ±100mV or ±1V DC input range;  ±0.1% of span Accuracy (typical).


Cold Junction Compensation (CJC) Accuracy: ±0.5°C.

Noise Rejection: Normal Mode: Better than 40dB @ 60Hz.
Common Mode: Better than 140dB @ 60Hz.

Input Filter Bandwidth: -3dB at 3Hz, typical.

Input Conversion Rate: 80mS per channel.

Environmental

Ambient Temperature and Humidity
Operating: -25 to 70°C (-13 to 158°F).
Storage: -40 to 85°C (-40 to 185°F).
Relative humidity: 5 to 95%, non-condensing.

Isolation: 1500V AC for 60 seconds or 250V AC continuous.  3-way isolation between I/O, network, and power.

NOTE: i2o function only available on 6-channel Modbus TCP/IP modules.

Communication

Connector: Shielded RJ-45 sockets, 8-pin, 10BaseT/100BaseTX.

Wiring: Wired MDI. 9xxEN I/O modules do NOT support autocrossover. 900EN switch supports auto-crossover.

Protocol: EtherNet/IP or Modbus TCP/IP with web browser configuration. EtherNet/IP supports PCCC object for communication with legacy PLCs (e.g. SLC505).

IP Address: Default static IP address is 128.1.1.100.

Port:
Ethernet Modbus TCP/IP models (9xxEN-4xxx): Up to 10 Modbus TCP/IP sockets supported.
EtherNet/IP models (9xxEN-6xxx): Up to 10 EtherNet/IP sockets and 1 Modbus TCP/IP socket.

Data Rate: Auto-sensed, 10Mbps or 100Mbps.

Duplex: Auto-negotiated, full or half-duplex.

Compliance: IEEE 802.3, 802.3u, 802.3x, Ethernet II.

Configuration: Web page for configuration and control is built-in with Ethernet access via a standard web browser.

Communication Distance: Distance between network devices is generally limited to 100 meters using recommended cable. Distances may be extended using hubs and switches.

Address: IP address is automatically acquired at startup. Unit may be configured to retrieve this address from the network server using BOOTP (Bootstrap Protocol), or via DHCP (Dynamic Configuration Protocol). A static IP address is also user-programmable. A default toggle switch sets the static IP address to the default factory address of 128.1.1.100 for initial configuration.

Environmental

Isolation: I/O channel, power, and network circuits are isolated from each other for common-mode voltages up to 250VAC, or 354V DC off DC power ground, on a continuous basis (will withstand 1500VAC dielectric strength test for one minute without breakdown). Complies with test requirements of ANSI/ISA-82.01- 1988 for voltage rating specified.

Electromagnetic Compatibility (EMC)

Immunity per European Norm EN50082-1. Emissions per European Norm EN50081-1.

Electrostatic Discharge (ESD) Immunity Per EN61000-4-2.

Radiated Field Immunity (RFI) Per EN61000-4-3 and ENV50204.

Electrical Fast Transient Immunity (EFT) Per EN61000-4-4.

Conducted RF Immunity (CRFI) Per EN61000-4-6.

Surge Immunity Per EN61000-4-5.

Radiated Frequency Emissions Per EN55022 Class B.

  •  Configurable from standard web browser
  • EtherNet/IP® or Ethernet Modbus TCP/IP communication with automatic 10/100Mbps data rate negotiation
  • 6-input stand-alone module is very economical
  • i2o function enables direct input-to-output communication without a network controller
  • Universal inputs support a variety of sensors
  • Built-in CJC sensor on each terminal block produces more precise temperature measurements
  • Thermocouple break detection (upscale or downscale) identifies sensor wiring failures
  • High-resolution 16-bit sigma-delta A/D converters ensure precise, high accuracy measurements
  • Compact packaging with pluggable terminals
  • Wide operational temperature range: -25°C to 70°C (-13° to 158°F)
  • Approvals: CE/ATEX marked; UL, cUL listed, Class 1 Div 2 Groups A, B, C, D; EtherNet/IP, Modbus/TCP conformance tested.

Specs & Catalogs

Manuals

965EN-4004, 965EN-4006 User Manual (Log in to download the file)

965EN-6004, 965EN-6006 User Manual (Log in to download the file)

Ethernet IP EDS For XTxxx2-000 Modules (Log in to download the file)
965EN: Ethernet Temperature Input Modules (Log in to download the file)

Additional information

Weight 10 oz
Dimensions 4.5 × 1.5 × 5 in
Part Number

965EN-4004: Ethernet Modbus TCP/IP, 4 channel, 965EN-4006: Ethernet Modbus TCP/IP, 6 channel, 965EN-6004: Ethernet/IP Analog: 4 channel, 965EN-6006: Ethernet/IP, 6 channel

FPGA Type
Logic Cells
Power
Communication

Ethernet/IP, i2o Peer-to-Peer, Modbus TCP/IP

Product Series

BusWorks 900EN Series

Configuration

Built-in Web pages

  • Description

    These modules provide an isolated Ethernet network interface for up to six input channels. Differential inputs eliminate ground noise and each terminal block includes a cold junction compensation (CJC) sensor for more precise temperature measurements. Multi-range inputs accept signals from a variety of sensors and devices. High-resolution, low noise, A/D converters deliver high accuracy and reliability.

    Input Ranges
    Ranges are selectable for a 3-channel group.

    Thermocouple (user-selectable type) Type J, K, T, R, S, E, B, or N.

    DC Millivolts (user-selectable range) ±100mV or ±1V DC.

    Network Communication
    EtherNet/IP or Modbus TCP/IP 10/100Mbps with automatic data rate negotiation.

    Power Requirement
    15 to 36V DC supply (2 Watts) required.

    Approvals
    CE/ATEX marked.  UL, cUL listed, Class I; Div. 2; Groups A, B, C, D. EtherNet/IP, Modbus/TCP conformance tested.

    Performance Specifications 
    Input


    Accuracy
    Type J:  -210 to 760°C input range;  ±0.5°C Accuracy (typical).

    Type K: -200 to 1372°C input range; ±0.5°C Accuracy (typical).

    Type T: -260 to 400°C  input range; ±0.5°C Accuracy (typical).

    Type R: -50 to 1768°C input range;  ±1.0°C Accuracy (typical).

    Type S: -50 to 1768°C input range; ±1.0°C Accuracy (typical).

    Type E: -200 to 1000°C input range;  ±0.5°C Accuracy (typical).

    Type B: 260 to 1820°C input range; ±1.0°C Accuracy (typical).

    Type N: -230 to -170°C input range;  ±1.0°C Accuracy (typical).

    Type N: -170 to 1300°C input range;  ±0.5°C). Accuracy (typical).

    Voltage: ±100mV or ±1V DC input range;  ±0.1% of span Accuracy (typical).


    Cold Junction Compensation (CJC) Accuracy: ±0.5°C.

    Noise Rejection: Normal Mode: Better than 40dB @ 60Hz.
    Common Mode: Better than 140dB @ 60Hz.

    Input Filter Bandwidth: -3dB at 3Hz, typical.

    Input Conversion Rate: 80mS per channel.

    Environmental

    Ambient Temperature and Humidity
    Operating: -25 to 70°C (-13 to 158°F).
    Storage: -40 to 85°C (-40 to 185°F).
    Relative humidity: 5 to 95%, non-condensing.

    Isolation: 1500V AC for 60 seconds or 250V AC continuous.  3-way isolation between I/O, network, and power.

    NOTE: i2o function only available on 6-channel Modbus TCP/IP modules.

    Communication

    Connector: Shielded RJ-45 sockets, 8-pin, 10BaseT/100BaseTX.

    Wiring: Wired MDI. 9xxEN I/O modules do NOT support autocrossover. 900EN switch supports auto-crossover.

    Protocol: EtherNet/IP or Modbus TCP/IP with web browser configuration. EtherNet/IP supports PCCC object for communication with legacy PLCs (e.g. SLC505).

    IP Address: Default static IP address is 128.1.1.100.

    Port:
    Ethernet Modbus TCP/IP models (9xxEN-4xxx): Up to 10 Modbus TCP/IP sockets supported.
    EtherNet/IP models (9xxEN-6xxx): Up to 10 EtherNet/IP sockets and 1 Modbus TCP/IP socket.

    Data Rate: Auto-sensed, 10Mbps or 100Mbps.

    Duplex: Auto-negotiated, full or half-duplex.

    Compliance: IEEE 802.3, 802.3u, 802.3x, Ethernet II.

    Configuration: Web page for configuration and control is built-in with Ethernet access via a standard web browser.

    Communication Distance: Distance between network devices is generally limited to 100 meters using recommended cable. Distances may be extended using hubs and switches.

    Address: IP address is automatically acquired at startup. Unit may be configured to retrieve this address from the network server using BOOTP (Bootstrap Protocol), or via DHCP (Dynamic Configuration Protocol). A static IP address is also user-programmable. A default toggle switch sets the static IP address to the default factory address of 128.1.1.100 for initial configuration.

    Environmental

    Isolation: I/O channel, power, and network circuits are isolated from each other for common-mode voltages up to 250VAC, or 354V DC off DC power ground, on a continuous basis (will withstand 1500VAC dielectric strength test for one minute without breakdown). Complies with test requirements of ANSI/ISA-82.01- 1988 for voltage rating specified.

    Electromagnetic Compatibility (EMC)

    Immunity per European Norm EN50082-1. Emissions per European Norm EN50081-1.

    Electrostatic Discharge (ESD) Immunity Per EN61000-4-2.

    Radiated Field Immunity (RFI) Per EN61000-4-3 and ENV50204.

    Electrical Fast Transient Immunity (EFT) Per EN61000-4-4.

    Conducted RF Immunity (CRFI) Per EN61000-4-6.

    Surge Immunity Per EN61000-4-5.

    Radiated Frequency Emissions Per EN55022 Class B.

  • Features & Benefits

    •  Configurable from standard web browser
    • EtherNet/IP® or Ethernet Modbus TCP/IP communication with automatic 10/100Mbps data rate negotiation
    • 6-input stand-alone module is very economical
    • i2o function enables direct input-to-output communication without a network controller
    • Universal inputs support a variety of sensors
    • Built-in CJC sensor on each terminal block produces more precise temperature measurements
    • Thermocouple break detection (upscale or downscale) identifies sensor wiring failures
    • High-resolution 16-bit sigma-delta A/D converters ensure precise, high accuracy measurements
    • Compact packaging with pluggable terminals
    • Wide operational temperature range: -25°C to 70°C (-13° to 158°F)
    • Approvals: CE/ATEX marked; UL, cUL listed, Class 1 Div 2 Groups A, B, C, D; EtherNet/IP, Modbus/TCP conformance tested.
  • Specs & Data Sheets

    Specs & Catalogs

    Manuals

    965EN-4004, 965EN-4006 User Manual (Log in to download the file)

    965EN-6004, 965EN-6006 User Manual (Log in to download the file)

  • Software

    Ethernet IP EDS For XTxxx2-000 Modules (Log in to download the file)
    965EN: Ethernet Temperature Input Modules (Log in to download the file)
  • Additional information

    Additional information

    Weight 10 oz
    Dimensions 4.5 × 1.5 × 5 in
    Part Number

    965EN-4004: Ethernet Modbus TCP/IP, 4 channel, 965EN-4006: Ethernet Modbus TCP/IP, 6 channel, 965EN-6004: Ethernet/IP Analog: 4 channel, 965EN-6006: Ethernet/IP, 6 channel

    FPGA Type
    Logic Cells
    Power
    Communication

    Ethernet/IP, i2o Peer-to-Peer, Modbus TCP/IP

    Product Series

    BusWorks 900EN Series

    Configuration

    Built-in Web pages