Click to zoom
$320
Clear
Product short description:
  • 10/100Mbps
  • 15 to 36V DC power supply required
  • Five shielded RJ-45 sockets, 8-pin, 10Base-T / 100Base-TX
RSS
FACEBOOK
FACEBOOK
TWITTER
Visit Us
LINKEDIN

Acromag’s five-port Ethernet switch is specially designed for use in industrial applications. Rugged construction and a variety of security features ensure reliable operation under demanding conditions.

Internal intelligence enables “connect and go” operation for fast and easy network installation with auto-negotiation of data rate, flow control, and crossover signal compatibility.

No configuration is necessary when the 900EN-S005 is used as a simple switch with Acromag I/O modules. For advanced users, this switch offers numerous control functions that are easily configured through DIP-switch settings or programmed using your computer.

  • Industrial-Grade
  • Reliable performance over wide -25 to 70°C ambient temperature range
  • Wide-Range DC-power with redundant power connection for optional standby backup power
  • Hardened for harsh environments to protect from RFI, EMI, ESD, EFT, and surges
  • Fully isolated for safety and increased noise immunity with power-to-network and port-to-port isolation
  • Easy mounting, removal, and replacement with plug-In terminal and DIN-rail mount
  • Approvals: CE/ATEX marked; UL, cUL listed, Class 1 Div 2 Groups A, B, C, D.

Manuals

900EN-S005 User Manual (Log in to download the file)

ESW-MBLIB-DEMO (Log in to download the file)
ATMX Demo Software (Log in to download the file)
AMTN-DEMO (Log in to download the file)
  • Compare

    AMTN, AMTX: ActiveX / .NET Controls for Modbus I/O

    • Modbus/TCP or Modbus/RTU
    • These ActiveX / .NET software controls provide a fast, easy way to communicate with any Modbus slave devices connected to your PC.
    • Get your Visual Basic, Visual C, .NET, Excel, or other compatible applications talking Modbus protocol within minutes.
    $250$330
    Select options
  • Compare

    ESW-MBLIB: Ethernet Modbus C Library Software

    • Universal support for five operating systems
    • C source code provided
    • Demo program included
    $0$310
    Read more

Additional information

Weight 8 oz
Dimensions 9 × 2.5 × 7.25 in
Part Number

ESW-MBLIB: Ethernet Modbus C-Library Software, ESW-MBLIB_DEMO: Demo program for ESW-MBLIB

Communication

i2o Peer-to-Peer, Modbus TCP/IP, Modbus UDP/IP

Product Series

EtherStax Series

  • Description

    Acromag’s Modbus C Library software greatly simplifies development of programs to interface with Acromag’s BusWorks® and EtherStax® Ethernet I/O products. The library also supports any standard Ethernet Modbus slave device that communicates via Modbus TCP/IP or UDP/IP protocol. This utility is ideal for developers that are unfamiliar with Modbus protocol or the framing of TCP/IP or UDP/IP messages.

    The C library makes programming easy and portable by simply linking user code with the provided function calls (below). Most function calls require passing only a few parameters such as the IP address, Modbus register address, and
    register count.

    Codes | Functions
    01 (01H)  | Read Coil (Output) Status
    02 (02H) | Read Input Status
    03 (03H) | Read Holding Registers
    04 (04H) | Read Input Registers
    05 (05H) | Force Single Coil (Output)
    06 (06H) | Preset Single Register
    15 (0FH) | Force Multiple Coils (Outputs)
    16 (10H) | Preset Multiple Registers
    17 (11H) | Report Slave ID

    Example Program

    The included example program is menu-driven to help users build Modbus TCP/IP and UDP/IP commands. Menu selections let users configure, read, and write Ethernet I/O slave devices such as Acromag’s BusWorks and EtherStax products.

    Users may also leverage this demonstration application into a tool for configuration or test by supplying commands and/or data values in the form of a text file. The program will execute each command in the text file as if it had been typed from the console terminal.

  • Features & Benefits

    • Industrial-Grade
    • Reliable performance over wide -25 to 70°C ambient temperature range
    • Wide-Range DC-power with redundant power connection for optional standby backup power
    • Hardened for harsh environments to protect from RFI, EMI, ESD, EFT, and surges
    • Fully isolated for safety and increased noise immunity with power-to-network and port-to-port isolation
    • Easy mounting, removal, and replacement with plug-In terminal and DIN-rail mount
    • Approvals: CE/ATEX marked; UL, cUL listed, Class 1 Div 2 Groups A, B, C, D.
  • Specs & Data Sheets

    Manuals

    900EN-S005 User Manual (Log in to download the file)

  • Software

    ESW-MBLIB-DEMO (Log in to download the file)
    ATMX Demo Software (Log in to download the file)
    AMTN-DEMO (Log in to download the file)
  • Accessories

    • Compare

      AMTN, AMTX: ActiveX / .NET Controls for Modbus I/O

      • Modbus/TCP or Modbus/RTU
      • These ActiveX / .NET software controls provide a fast, easy way to communicate with any Modbus slave devices connected to your PC.
      • Get your Visual Basic, Visual C, .NET, Excel, or other compatible applications talking Modbus protocol within minutes.
      $250$330
      Select options
    • Compare

      ESW-MBLIB: Ethernet Modbus C Library Software

      • Universal support for five operating systems
      • C source code provided
      • Demo program included
      $0$310
      Read more
  • Additional information

    Additional information

    Weight 8 oz
    Dimensions 9 × 2.5 × 7.25 in
    Part Number

    ESW-MBLIB: Ethernet Modbus C-Library Software, ESW-MBLIB_DEMO: Demo program for ESW-MBLIB

    Communication

    i2o Peer-to-Peer, Modbus TCP/IP, Modbus UDP/IP

    Product Series

    EtherStax Series