  • Universal thermocouple / millivolt input
  • Universal current / voltage output
  • 12-32V DC local / bus power

The TT333 model is a space-saving four-wire transmitter that isolates and converts a millivolt or thermocouple sensor input to a proportional control signal. DC current and voltage output are both supported on a single model.

Click here to watch a short video highlighting the TT330 Series.

 

 

TT333: TC / mV Input Four-wire Transmitter Description

The TT333 model is a space-saving four-wire transmitter that isolates and converts a millivolt or thermocouple sensor input to a proportional control signal. DC current and voltage output are both supported on a single model. An optional DIN rail bus can deliver primary or redundant power to multiple units without wiring.

High-voltage isolation separates the input from the output circuit. Isolation protects from surges, reduces noise, and eliminates ground loop errors.

Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software.

Advanced signal processing capabilities, variable range input, and convenient USB programming make this instrument a very versatile temperature measurement device. These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.

Performance Specifications

IMPORTANT: To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends the use of their USB-ISOLATOR when configuring a TT330 Series transmitter.

USB Interface

USB Connector

Type: USB Mini-B type socket, 5-pin.

Data Rate: 12Mbps. USB v1.1 and 2.0 compatible.

Maximum Cable Length: 5.0 meters.

Transient Protection: Transient voltage suppression on power and data lines.

Driver: Not required. Uses Windows HID drivers.

Input

Default Configuration/Calibration
Input: TC J, -210 to 760°C, medium filter, Break: up.
Output: 4 to 20mA.

Input Ranges and Accuracy
Input                         Range                                     Accuracy
TC J         -210 to 760°C (-346 to 1400°F)             ±0.5°C
TC K        -200 to 1372°C (-328 to 2502°F)           ±0.5°C
TC T        -260 to 400°C (-436 to 752°F)                ±0.5°C
TC R          -50 to 1768°C (-58 to 3214°F)               ±1.0°C
TC S          -50 to 1768°C (-58 to 3214°F)               ±1.0°C
TC E        -200 to 1000°C (-328 to 1832°F)           ±0.5°C
TC B        260 to 1820°C (500 to 3308°F)              ±1.0°C
TC N       -230 to -1300°C (-274 to 2372°F            ±1.0°C
mV          -100 to 100mV                                            ±0.1mV
Error includes the effects of repeatability, terminal point conformity, and linearization.

Thermocouple Reference (Cold Junction Compensation): ±0.2°C typical, ±0.5°C maximum at 25°C.

Ambient Temperature Effect: Better than ±80ppm/°C (±0.008%/°C).

Scaling Adjust
Zero: 0 to 95% of range, typical.

Full Scale: 5 to 100% of full scale range, typical.

Lead Break (Sensor Burnout) Detection: Upscale/downscale ±5% full scale range typical.

Input Over-Voltage Protection: Bipolar Transient Voltage Suppressers (TVS), 5.6V clamp level typical.

Input Resolution
Millivolt input: 0.0025% (1 part in 40,000).
Thermocouple input: 0.1°C.

Input Impedance
Current input: 24.9 ohms.
Voltage input: 15M ohms.

Input Filter: Selectable digital filtering settings (none, low, medium, high).

Noise Rejection (Common Mode, High Filter)
Normal mode @ 60Hz: >0.5dB (no filter), >80dB (high filter).
Common mode @ 60Hz: >100dB (no filter), >130dB (high filter).

Output

Output Range
Range                    Over-Range                 Resolution
±10V                            ±10.5V                       1 part in 62415
±5V                               ±5.25V                      1 part in 31208
0 to 10V              –0.5527 to +10.5V        1 part in 59240
0 to 5V              –0.27634 to +5.25V        1 part in 60262
±20mA                        ±10.5V                      1 part in 62259
0 to 20mA          –1.1054 to 21mA         1 part in 58596
4 to 20mA          –1.1054 to 21mA         1 part in 46877

Output Load
Voltage output: 1K ohms minimum.
Current output: 0-550 ohms.

Output Response Time (for step input change)

Time to reach 98% of output value (typical)
No filter                   15 milliseconds
Low filter                40 milliseconds
Medium filter      120 milliseconds
High filter             850 milliseconds

Output Ripple: Less than ±0.1% of output span.

Output Ambient Temperature Drift: Better than ±80ppm/°C (±0.0080%/°C.

Environmental

Operating temperature: -40 to 80°C (-40° to 176°F).

Storage temperature: -40 to 85°C (-40 to 185°F).

Relative humidity: 5 to 95% non-condensing.

Power requirement: 12-32V DC SELV (Safety Extra Low Voltage), 24mA maximum.

Isolation: 1500V AC peak. 250V AC (354V DC) continuous isolation between input, output, and power (3-way).

Shock and Vibration Immunity
Vibration: 4g, per IEC 60068-2-6.
Shock: 25g, per IEC 60068-2-27.

Approvals: CE compliant. Designed for UL/cUL Class I Division 2 Groups ABCD. ATEX / IECEx certified Zone 2.

Electromagnetic Compatibility (EMC) Compliance
Radiated Emissions: BS EN 61000-6-4, CISPR 16.
RFI: BS EN 61000-6-2, IEC 61000-4-3.
Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6.
ESD: BS EN 61000-6-2, IEC 61000-4-2.
EFT: BS EN 61000-6-2, IEC 61000-4-4.
Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5.

Physical

General: General-purpose enclosure designed for mounting on 35mm “T-type” DIN rail.

Case Material: Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General-purpose NEMA Type 1 enclosure.

I/O Connectors: Removable plug-in terminal blocks rated for 12A/250V; AWG #26-12, stranded or solid copper wire.

Dimensions: 17.5 x 114.5 x 99.0 mm (0.7 x 4.51 x 3.90 inches).

Shipping Weight: 0.22 kg (0.5 pounds) packed.

  • Easy setup and digital calibration via USB with Windows configuration software
  • Universal thermocouple or millivolt input (TC Type J, K, T, R, S, E, B, N  or ±100mV)
  • Universal output connections support ranges up to ±21mA or ±10.5V DC without rewiring
  • Space-saving 17.5mm (0.7 inch) unit with pluggable terminals for convenient wiring
  • High accuracy, linearity, stability, and reliability
  • User-selectable filtering (low, medium, high)
  • Supports reverse-acting (inverse) output
  • Selectable upscale or downscale operation for sensor errors and lead-break detection
  • Bus power, local power, or both
  • Redundant power ready (rail/local)
  • 1500V input isolation
  • Shock (50g) and vibration (5g) resistant
  • Mounts on Type T DIN-rail
  • Wide ambient operation (-40 to 80°C)
  • CE compliant. UL/cUL Class I Div 2, ATEX / IECEx Zone 2 approvals

 

 

How to Minimize Thermocouple to Transmitter Measurement Errors - 8500926 (Log in to view the file)
Preventing Temperature Measurement Error in Thermocouple to Transmitter Connections The nature of thermocouple (TC) circuits is that they’re prone to produce error when mating them to a measurement device; unless you have some insight into how these TCs and their components work. This paper reviews thermocouple behavior and outlines common problems encountered when connecting them...
How to use Thermocouples for Temperature Measurement - 8500911 (Log in to view the file)
Criteria for Temperature Selection of T/C and RTD Sensor Types This is part two of a comprehensive three-part series that provides information for choosing an industrial temperature sensor from Thermocouple (T/C) and Resistance Temperature Detector (RTD) sensor types.   The Basics of Temperature Measurement Using Thermocouples You are probably somewhat familiar with the thermocouple, or...
How to use Thermocouple Transmitters to Monitor Temperatures in Paint Systems - 8400818
This document illustrates using Acromag’s TT330 Series to monitor high temperatures in an automotive paint curing oven and transmit to the existing PLC 4-20mA input card/software setup. Defining the Problem The area around an auto manufacturer’s paint curing ovens is at elevated temperatures affecting the performance of locally installed instrumentation. Placing signal conditioners rated for...

Manuals

TT333 User Manual (Log in to download the file)

Agility Config Tool (Tethered) (Log in to download the file)
TT300 Series Windows Configuration Software (Log in to download the file)
  • Compare

    TT330-Config/Cal: Calibration Service

    • Factory custom configuration/calibration service.
    • Specify input type, input/output zero and full-scale values, filtering, and sensor fault settings on order.
    Select options
  • Compare

    TTBus-Kit: DIN Rail Bus Power Connector

    • One kit supports multiple TT330 series transmitters.
    • For multiple DT330/351 or SP330 transmitters, one TTBUS-KIT is required for each transmitter to be DC Power wired via the bus rail power connections.
       
    Select options
  • Compare

    TTC-SIP: Software

    • Software Interface Package for Acromag DT, ST, TT Series Transmitters and SP, uBSP Series Signal Splitters.
    • Includes configuration sofware CD-ROM (5040-xxx), isolator (USB-ISOLATOR) and two USB cable (4001-112, 4001-113) (Recommend one kit per customer.)
    • Easy setup and digital calibration via USB with Windows configuration software.
    • Download the configuration software only - from the Software Tab
    Select options

Additional information

Weight 8 oz
Dimensions 4.51 × 0.5 × 3.9 in
Part Number

TT333-0700: Transmitter

Configuration

Agility Mobile App, Factory Calibration, USB Configuration, Windows Software Configuration

Product Series

TT330 Series

Power

DC Power

  • Description

    TT333: TC / mV Input Four-wire Transmitter Description

    The TT333 model is a space-saving four-wire transmitter that isolates and converts a millivolt or thermocouple sensor input to a proportional control signal. DC current and voltage output are both supported on a single model. An optional DIN rail bus can deliver primary or redundant power to multiple units without wiring.

    High-voltage isolation separates the input from the output circuit. Isolation protects from surges, reduces noise, and eliminates ground loop errors.

    Setup and calibration are fast and easy with a convenient USB connection to your PC and Acromag’s Windows configuration software.

    Advanced signal processing capabilities, variable range input, and convenient USB programming make this instrument a very versatile temperature measurement device. These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions.

    Performance Specifications

    IMPORTANT: To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends the use of their USB-ISOLATOR when configuring a TT330 Series transmitter.

    USB Interface

    USB Connector

    Type: USB Mini-B type socket, 5-pin.

    Data Rate: 12Mbps. USB v1.1 and 2.0 compatible.

    Maximum Cable Length: 5.0 meters.

    Transient Protection: Transient voltage suppression on power and data lines.

    Driver: Not required. Uses Windows HID drivers.

    Input

    Default Configuration/Calibration
    Input: TC J, -210 to 760°C, medium filter, Break: up.
    Output: 4 to 20mA.

    Input Ranges and Accuracy
    Input                         Range                                     Accuracy
    TC J         -210 to 760°C (-346 to 1400°F)             ±0.5°C
    TC K        -200 to 1372°C (-328 to 2502°F)           ±0.5°C
    TC T        -260 to 400°C (-436 to 752°F)                ±0.5°C
    TC R          -50 to 1768°C (-58 to 3214°F)               ±1.0°C
    TC S          -50 to 1768°C (-58 to 3214°F)               ±1.0°C
    TC E        -200 to 1000°C (-328 to 1832°F)           ±0.5°C
    TC B        260 to 1820°C (500 to 3308°F)              ±1.0°C
    TC N       -230 to -1300°C (-274 to 2372°F            ±1.0°C
    mV          -100 to 100mV                                            ±0.1mV
    Error includes the effects of repeatability, terminal point conformity, and linearization.

    Thermocouple Reference (Cold Junction Compensation): ±0.2°C typical, ±0.5°C maximum at 25°C.

    Ambient Temperature Effect: Better than ±80ppm/°C (±0.008%/°C).

    Scaling Adjust
    Zero: 0 to 95% of range, typical.

    Full Scale: 5 to 100% of full scale range, typical.

    Lead Break (Sensor Burnout) Detection: Upscale/downscale ±5% full scale range typical.

    Input Over-Voltage Protection: Bipolar Transient Voltage Suppressers (TVS), 5.6V clamp level typical.

    Input Resolution
    Millivolt input: 0.0025% (1 part in 40,000).
    Thermocouple input: 0.1°C.

    Input Impedance
    Current input: 24.9 ohms.
    Voltage input: 15M ohms.

    Input Filter: Selectable digital filtering settings (none, low, medium, high).

    Noise Rejection (Common Mode, High Filter)
    Normal mode @ 60Hz: >0.5dB (no filter), >80dB (high filter).
    Common mode @ 60Hz: >100dB (no filter), >130dB (high filter).

    Output

    Output Range
    Range                    Over-Range                 Resolution
    ±10V                            ±10.5V                       1 part in 62415
    ±5V                               ±5.25V                      1 part in 31208
    0 to 10V              –0.5527 to +10.5V        1 part in 59240
    0 to 5V              –0.27634 to +5.25V        1 part in 60262
    ±20mA                        ±10.5V                      1 part in 62259
    0 to 20mA          –1.1054 to 21mA         1 part in 58596
    4 to 20mA          –1.1054 to 21mA         1 part in 46877

    Output Load
    Voltage output: 1K ohms minimum.
    Current output: 0-550 ohms.

    Output Response Time (for step input change)

    Time to reach 98% of output value (typical)
    No filter                   15 milliseconds
    Low filter                40 milliseconds
    Medium filter      120 milliseconds
    High filter             850 milliseconds

    Output Ripple: Less than ±0.1% of output span.

    Output Ambient Temperature Drift: Better than ±80ppm/°C (±0.0080%/°C.

    Environmental

    Operating temperature: -40 to 80°C (-40° to 176°F).

    Storage temperature: -40 to 85°C (-40 to 185°F).

    Relative humidity: 5 to 95% non-condensing.

    Power requirement: 12-32V DC SELV (Safety Extra Low Voltage), 24mA maximum.

    Isolation: 1500V AC peak. 250V AC (354V DC) continuous isolation between input, output, and power (3-way).

    Shock and Vibration Immunity
    Vibration: 4g, per IEC 60068-2-6.
    Shock: 25g, per IEC 60068-2-27.

    Approvals: CE compliant. Designed for UL/cUL Class I Division 2 Groups ABCD. ATEX / IECEx certified Zone 2.

    Electromagnetic Compatibility (EMC) Compliance
    Radiated Emissions: BS EN 61000-6-4, CISPR 16.
    RFI: BS EN 61000-6-2, IEC 61000-4-3.
    Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6.
    ESD: BS EN 61000-6-2, IEC 61000-4-2.
    EFT: BS EN 61000-6-2, IEC 61000-4-4.
    Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5.

    Physical

    General: General-purpose enclosure designed for mounting on 35mm “T-type” DIN rail.

    Case Material: Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General-purpose NEMA Type 1 enclosure.

    I/O Connectors: Removable plug-in terminal blocks rated for 12A/250V; AWG #26-12, stranded or solid copper wire.

    Dimensions: 17.5 x 114.5 x 99.0 mm (0.7 x 4.51 x 3.90 inches).

    Shipping Weight: 0.22 kg (0.5 pounds) packed.

  • Features & Benefits

    • Easy setup and digital calibration via USB with Windows configuration software
    • Universal thermocouple or millivolt input (TC Type J, K, T, R, S, E, B, N  or ±100mV)
    • Universal output connections support ranges up to ±21mA or ±10.5V DC without rewiring
    • Space-saving 17.5mm (0.7 inch) unit with pluggable terminals for convenient wiring
    • High accuracy, linearity, stability, and reliability
    • User-selectable filtering (low, medium, high)
    • Supports reverse-acting (inverse) output
    • Selectable upscale or downscale operation for sensor errors and lead-break detection
    • Bus power, local power, or both
    • Redundant power ready (rail/local)
    • 1500V input isolation
    • Shock (50g) and vibration (5g) resistant
    • Mounts on Type T DIN-rail
    • Wide ambient operation (-40 to 80°C)
    • CE compliant. UL/cUL Class I Div 2, ATEX / IECEx Zone 2 approvals

     

     

  • Tech Papers

    How to Minimize Thermocouple to Transmitter Measurement Errors - 8500926 (Log in to view the file)
    Preventing Temperature Measurement Error in Thermocouple to Transmitter Connections The nature of thermocouple (TC) circuits is that they’re prone to produce error when mating them to a measurement device; unless you have some insight into how these TCs and their components work. This paper reviews thermocouple behavior and outlines common problems encountered when connecting them...
    How to use Thermocouples for Temperature Measurement - 8500911 (Log in to view the file)
    Criteria for Temperature Selection of T/C and RTD Sensor Types This is part two of a comprehensive three-part series that provides information for choosing an industrial temperature sensor from Thermocouple (T/C) and Resistance Temperature Detector (RTD) sensor types.   The Basics of Temperature Measurement Using Thermocouples You are probably somewhat familiar with the thermocouple, or...
    How to use Thermocouple Transmitters to Monitor Temperatures in Paint Systems - 8400818
    This document illustrates using Acromag’s TT330 Series to monitor high temperatures in an automotive paint curing oven and transmit to the existing PLC 4-20mA input card/software setup. Defining the Problem The area around an auto manufacturer’s paint curing ovens is at elevated temperatures affecting the performance of locally installed instrumentation. Placing signal conditioners rated for...
  • Specs & Data Sheets

    Manuals

    TT333 User Manual (Log in to download the file)

  • Software

    Agility Config Tool (Tethered) (Log in to download the file)
    TT300 Series Windows Configuration Software (Log in to download the file)
  • Accessories

    • Compare

      TT330-Config/Cal: Calibration Service

      • Factory custom configuration/calibration service.
      • Specify input type, input/output zero and full-scale values, filtering, and sensor fault settings on order.
      Select options
    • Compare

      TTBus-Kit: DIN Rail Bus Power Connector

      • One kit supports multiple TT330 series transmitters.
      • For multiple DT330/351 or SP330 transmitters, one TTBUS-KIT is required for each transmitter to be DC Power wired via the bus rail power connections.
         
      Select options
    • Compare

      TTC-SIP: Software

      • Software Interface Package for Acromag DT, ST, TT Series Transmitters and SP, uBSP Series Signal Splitters.
      • Includes configuration sofware CD-ROM (5040-xxx), isolator (USB-ISOLATOR) and two USB cable (4001-112, 4001-113) (Recommend one kit per customer.)
      • Easy setup and digital calibration via USB with Windows configuration software.
      • Download the configuration software only - from the Software Tab
      Select options
  • Additional information

    Additional information

    Weight 8 oz
    Dimensions 4.51 × 0.5 × 3.9 in
    Part Number

    TT333-0700: Transmitter

    Configuration

    Agility Mobile App, Factory Calibration, USB Configuration, Windows Software Configuration

    Product Series

    TT330 Series

    Power

    DC Power