Click to zoom

Please sign in or register to see model options and to add products to your cart.

Product short description:
  • Loop-powered Process Meter
  • 4-20mA input/output
  • Solid-state relays
  • Non-incendive, intrinsically safe

These loop-powered 1/8 DIN digital panel meters provide a convenient and informative display of any 4-20mA signal. A dual line display shows the process value on the top line and the units or a tag on the bottom line. Alternatively, you can display the input in one scale on the top line (e.g. height) and another scale on the bottom (e.g. volume).

Click here to watch a short video highlighting the VPM2000 Series.

VPM2000 Vertu® Series Loop-Powered Panel Meter Description

Acromag Vertu® VPM2000 loop-powered 1/8 DIN digital panel meters provide a convenient and informative display of any 4-20mA signal. A dual line display shows the process value on the top line and the units or a tag on the bottom line.

Alternatively, you can display the input in one scale on the top line (e.g. height) and another scale on the bottom (e.g. volume). A bar graph option indicates the percentage the value represents.

All models include a digital input and two open collector outputs. For signal isolator and alarm trip applications, model options add two solid state relays or 4-20mA analog output. The digital input enables remote reset or triggering of alarms.

Open collector outputs are useful for alarm indication or pulse output. Relays support alarm activation, on/off control, and pump alternation functions.

Installation is greatly simplified as the meters acquire power from the 4-20mA loop and therefore require no separate power source. A low voltage drop adds very little burden to the loop.

The NEMA 4X IP65 panel, conformal-coated PCBs, wide temperature operation, and a backlit LCD enable use in most environments.

Intrinsically safe and non-incendive versions allow installation in hazardous areas.

Setup is fast and easy using the front panel buttons or the free configuration software. A micro USB cable connects the meter to the PC and provides power for software-based programming and saving the file.

The push buttons also serve as programmable function keys to change displays, reset min/max readings, acknowledge alarms, and other uses.

VPM2000 Vertu® Series Loop-Powered Panel Meter Performance Specifications

  • Loop-powered process meter
  •  4-20mA input
  • Two open collector outputs standard
  • Optional loop-powered solid-state relays
  • Optional 4-20mA analog output
  • 1.5 volt drop (4.5 volt drop with backlight)
  • Loop-powered backlight with red backlight for alarm conditions
  • Free PC-based USB programming software
  • 5-digit alphanumeric top line,
    8- digit alphanumeric bottom line
  • 20-segment bargraph with percent indication
  • Relay pump alternation based on level and runtime
  • Display relay runtime and cycle count
  • UL/cUL 61010 listed for electrical safety
  • UL/cUL listed as intrinsically safe and non-incendive
  • -40 to 167°F (-40 to 75°C) safe area operating temperature range
Why Do I Need Electrical Isolation? - 8500988 (Log in to view the file)
Why do we need signal isolation? Acromag is in the business of signal conditioning. We manufacture circuits that amplify, isolate, filter, and convert one signal form to another. Most of these circuits also provide electrical isolation. However, added isolation has a cost. Thus, sometimes customers either question their need for isolation or fail to recognize...
How to Display and Maintain Tank Levels in a Hazardous Area - 8401047
Defining the Problem: A chemical manufacturer has various tanks of substances which it combines to manufacture their product. The tops of these tanks are a UL rated Class 1 Division 2 hazardous area. They use four-wire, non-contact level sensors, and want their operators to be able to read and adjust the tank levels either automatically...
  • Loop-powered Process Meter
  • 4-20mA input/output
  • Solid-state relays
  • Non-incendive, intrinsically safe
These loop-powered 1/8 DIN digital panel meters provide a convenient and informative display of any 4-20mA signal. A dual line display shows the process value on the top line and the units or a tag on the bottom line. Alternatively, you can display the input in one scale on the top line (e.g. height) and another scale on the bottom (e.g. volume). Click here to watch a short video highlighting the VPM2000 Series.
How to Select a 4-20mA Isolator - 8400850 (Log in to view the file)
Click here to download How to Select a 4-20mA Isolator Introduction Acromag manufactures a variety of isolators to provide a cost effective solution for many applications. The main reasons for using an isolator are to: eliminate bucking power supplies; protect expensive control room equipment from transient spikes; and break ground loops that may exist between...

Manuals

VPM2000 User Manual (Log in to download the file)

VPM2000 Series UL/C-UL Listed Loop-Powered Isolator Intrinsic Safety Control Drawing (Log in to download the file)

VPM2000 Series DisplayWizard LP Software (Log in to download the file)
  • Compare

    4001-095: USB-to-Serial Adapter

    • USB-to-serial adapter
    • Easy to use to setup and re-configure modules
    Select options
  • Compare

    Digital Display Panel Meter Accessories

    • Plastic enclosure
    • Pipe-mount kit
    • Cables
    • Adapters
    Select from a variety of of panel meter accessories.  
    Select options
  • Compare

    Digital Display Panel Meter Accessories

    Select options

Additional information

Weight 160 oz
Dimensions 6 × 6 × 6 in
Part Number

VPM2111: Digital Display Panel Meter, VPM2112: Digital Display Alarm, Relays, VPM2113: Digital Display Isolator, 4-20mA Output, VPM2114: Digital Display Isolator/Alarm, 4-20mA Output, Relays, VPM2121: Digital Display Panel Meter, Bar Graph, VPM2122: Digital Display Alarm, Bar Graph, Relays, VPM2123: Digital Display Isolator, Bar Graph, 4-20mA Output, VPM2124: Digital Display Isolator/Alarm, Bar Graph, 4-20mA Output, Relays, VPM2211: Digital Display, IS, VPM2212: Digital Display Alarm, IS, Relays, VPM2213: Digital Display Isolator, IS, 4-20mA Output, VPM2214: Digital Display Isolator/Alarm, IS, 4-20mA Output, Relays, VPM2221: Digital Display, IS, Bar Graph, VPM2222: Digital Display Alarm, IS, Bar Graph, Relays, VPM2223: Digital Display Isolator, IS, Bar Graph, 4-20mA Output, VPM2224: Digital Display Isolator/Alarm, IS, Bar Graph, 4-20mA Output, Relays

  • Description

    VPM2000 Vertu® Series Loop-Powered Panel Meter Description

    Acromag Vertu® VPM2000 loop-powered 1/8 DIN digital panel meters provide a convenient and informative display of any 4-20mA signal. A dual line display shows the process value on the top line and the units or a tag on the bottom line.

    Alternatively, you can display the input in one scale on the top line (e.g. height) and another scale on the bottom (e.g. volume). A bar graph option indicates the percentage the value represents.

    All models include a digital input and two open collector outputs. For signal isolator and alarm trip applications, model options add two solid state relays or 4-20mA analog output. The digital input enables remote reset or triggering of alarms.

    Open collector outputs are useful for alarm indication or pulse output. Relays support alarm activation, on/off control, and pump alternation functions.

    Installation is greatly simplified as the meters acquire power from the 4-20mA loop and therefore require no separate power source. A low voltage drop adds very little burden to the loop.

    The NEMA 4X IP65 panel, conformal-coated PCBs, wide temperature operation, and a backlit LCD enable use in most environments.

    Intrinsically safe and non-incendive versions allow installation in hazardous areas.

    Setup is fast and easy using the front panel buttons or the free configuration software. A micro USB cable connects the meter to the PC and provides power for software-based programming and saving the file.

    The push buttons also serve as programmable function keys to change displays, reset min/max readings, acknowledge alarms, and other uses.

    VPM2000 Vertu® Series Loop-Powered Panel Meter Performance Specifications

    • Loop-powered process meter
    •  4-20mA input
    • Two open collector outputs standard
    • Optional loop-powered solid-state relays
    • Optional 4-20mA analog output
    • 1.5 volt drop (4.5 volt drop with backlight)
    • Loop-powered backlight with red backlight for alarm conditions
    • Free PC-based USB programming software
    • 5-digit alphanumeric top line,
      8- digit alphanumeric bottom line
    • 20-segment bargraph with percent indication
    • Relay pump alternation based on level and runtime
    • Display relay runtime and cycle count
    • UL/cUL 61010 listed for electrical safety
    • UL/cUL listed as intrinsically safe and non-incendive
    • -40 to 167°F (-40 to 75°C) safe area operating temperature range
  • Tech Papers

    Why Do I Need Electrical Isolation? - 8500988 (Log in to view the file)
    Why do we need signal isolation? Acromag is in the business of signal conditioning. We manufacture circuits that amplify, isolate, filter, and convert one signal form to another. Most of these circuits also provide electrical isolation. However, added isolation has a cost. Thus, sometimes customers either question their need for isolation or fail to recognize...
    How to Display and Maintain Tank Levels in a Hazardous Area - 8401047
    Defining the Problem: A chemical manufacturer has various tanks of substances which it combines to manufacture their product. The tops of these tanks are a UL rated Class 1 Division 2 hazardous area. They use four-wire, non-contact level sensors, and want their operators to be able to read and adjust the tank levels either automatically...
    • Loop-powered Process Meter
    • 4-20mA input/output
    • Solid-state relays
    • Non-incendive, intrinsically safe
    These loop-powered 1/8 DIN digital panel meters provide a convenient and informative display of any 4-20mA signal. A dual line display shows the process value on the top line and the units or a tag on the bottom line. Alternatively, you can display the input in one scale on the top line (e.g. height) and another scale on the bottom (e.g. volume). Click here to watch a short video highlighting the VPM2000 Series.
    How to Select a 4-20mA Isolator - 8400850 (Log in to view the file)
    Click here to download How to Select a 4-20mA Isolator Introduction Acromag manufactures a variety of isolators to provide a cost effective solution for many applications. The main reasons for using an isolator are to: eliminate bucking power supplies; protect expensive control room equipment from transient spikes; and break ground loops that may exist between...
  • Specs & Data Sheets

    Manuals

    VPM2000 User Manual (Log in to download the file)

    VPM2000 Series UL/C-UL Listed Loop-Powered Isolator Intrinsic Safety Control Drawing (Log in to download the file)

  • Software

    VPM2000 Series DisplayWizard LP Software (Log in to download the file)
  • Accessories

    • Compare

      4001-095: USB-to-Serial Adapter

      • USB-to-serial adapter
      • Easy to use to setup and re-configure modules
      Select options
    • Compare

      Digital Display Panel Meter Accessories

      • Plastic enclosure
      • Pipe-mount kit
      • Cables
      • Adapters
      Select from a variety of of panel meter accessories.  
      Select options
    • Compare

      Digital Display Panel Meter Accessories

      Select options
  • Additional information

    Additional information

    Weight 160 oz
    Dimensions 6 × 6 × 6 in
    Part Number

    VPM2111: Digital Display Panel Meter, VPM2112: Digital Display Alarm, Relays, VPM2113: Digital Display Isolator, 4-20mA Output, VPM2114: Digital Display Isolator/Alarm, 4-20mA Output, Relays, VPM2121: Digital Display Panel Meter, Bar Graph, VPM2122: Digital Display Alarm, Bar Graph, Relays, VPM2123: Digital Display Isolator, Bar Graph, 4-20mA Output, VPM2124: Digital Display Isolator/Alarm, Bar Graph, 4-20mA Output, Relays, VPM2211: Digital Display, IS, VPM2212: Digital Display Alarm, IS, Relays, VPM2213: Digital Display Isolator, IS, 4-20mA Output, VPM2214: Digital Display Isolator/Alarm, IS, 4-20mA Output, Relays, VPM2221: Digital Display, IS, Bar Graph, VPM2222: Digital Display Alarm, IS, Bar Graph, Relays, VPM2223: Digital Display Isolator, IS, Bar Graph, 4-20mA Output, VPM2224: Digital Display Isolator/Alarm, IS, Bar Graph, 4-20mA Output, Relays