Click to zoom

Please sign in or register to see model options and to add products to your cart.

Product short description:
  • ±100V or 0 to 22mA DC input ranges or 2 input channels, ±100V or 0 to 22mA DC input ranges (AC current with optional sensor)
  • Single or dual mechanical relays
  • 10-36V DC power
  • Software configured; multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection); on/off controller capability

IntelliPack alarms compare inputs against user-defined limit set-points to control built-in relays.

 

811A, 812A Intelligent Alarm with DC Voltage/Current Input Description

IntelliPack alarms compare inputs against user-defined limit set-points to control built-in relays.

Each unit offers a selection of input ranges and alarm functions to handle a broad range of applications. As your needs change, you can easily reconfigure the unit for different ranges or functions. Alarm functions available on all models include on/off controller, limit alarm, window alarm, deviation alarm, rate-of-change alarm, and peak/valley detection.

Setup is very easy. IntelliPack alarms are configured through a user-friendly Windows 7 or newer program. Field adjustments and re-calibration are quickly performed with front-panel push-buttons and status LEDs. Once configured, IntelliPacks operate independent of any host computer.

Learn more about the Intellipack Series and view all models >

811A, 812A Intelligent Alarm with DC Voltage/Current Input Features & Benefits

  • Integrated micro-controller performs intelligent signal processing for advanced alarm functions
  • Windows 7 or newer software configuration speeds setup and replacement
  • Push-button re-programmability facilitates changes in the field without a host PC
  • Multi-purpose inputs accept numerous ranges to reduce spare stock requirements
  • High-resolution Sigma-Delta A/D converter delivers high accuracy with low noise
  • Input excitation supply on each input provides power for a two-wire transmitter
  • Dual alarm operation lets you perform two alarm functions at the same time

Learn more about the Intellipack Series and view all models >

Manuals

811A, 812A User Manual (Log in to download the file)

IntelliPack & Series 900MB Configuration Software Windows 7 or 8 User Manual (Log in to download the file)

How to Use SIIG USB-to-Serial Cable With Windows Tech Note (Log in to download the file)

IntelliPack & Series 900 Configuration Software: Windows 10 User Manual (Log in to download the file)

800C-SIP: IntelliPack Configuration Software Information Page (Log in to download the file)
IntelliPack Configuration Software 5030-881 (Log in to download the file)
  • Compare

    5020-350: Toroidal AC Current Sensor

    • AC Current Sensor to precondition an AC current input signal
    • Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
    Select options
  • Compare

    800C-SIP: IntelliPack Configuration Software

    • Configuration Software
    • USB-to-RS232 Adapter
    • RS232-to-RJ11 Adapter
    • Interface Cable
    Acromag’s configuration software is the key to the IntelliPack’s easy-to-use operation. The software employs the friendly Windows® interface with pull-down selection menus and fill-in-the-blank fields to speed you through a few brief configuration screens. No programming is required.
    Select options
  • Compare

    PS5R: Slim Line Power Supplies

    • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
    • Universal Input (85-264V AC / 100-370V DC)
    • Lightweight and compact size
     
    Select options

Additional information

Weight 8 oz
Dimensions 5 × 1.25 × 4.5 in
Part Number

811A-0100: one DC voltage/current input, one DPDT relay, 811A-0200: one DC voltage/current input; two SPDT relays, 811A-0200-C: one DC voltage/current input; two SPDT relays, with factory configuration, 812A-0200: Dual alarm; two DC voltage/current inputs, two SPDT relays, 812A-0200-C: Dual alarm; two DC voltage/current inputs, two SPDT relays, with factory configuration

Configuration

Windows Software Configuration

Product Series

IntelliPack 800A Series

Power Type

DC Power, External Power

  • Description

    811A, 812A Intelligent Alarm with DC Voltage/Current Input Description

    IntelliPack alarms compare inputs against user-defined limit set-points to control built-in relays.

    Each unit offers a selection of input ranges and alarm functions to handle a broad range of applications. As your needs change, you can easily reconfigure the unit for different ranges or functions. Alarm functions available on all models include on/off controller, limit alarm, window alarm, deviation alarm, rate-of-change alarm, and peak/valley detection.

    Setup is very easy. IntelliPack alarms are configured through a user-friendly Windows 7 or newer program. Field adjustments and re-calibration are quickly performed with front-panel push-buttons and status LEDs. Once configured, IntelliPacks operate independent of any host computer.

    Learn more about the Intellipack Series and view all models >

    811A, 812A Intelligent Alarm with DC Voltage/Current Input Features & Benefits

    • Integrated micro-controller performs intelligent signal processing for advanced alarm functions
    • Windows 7 or newer software configuration speeds setup and replacement
    • Push-button re-programmability facilitates changes in the field without a host PC
    • Multi-purpose inputs accept numerous ranges to reduce spare stock requirements
    • High-resolution Sigma-Delta A/D converter delivers high accuracy with low noise
    • Input excitation supply on each input provides power for a two-wire transmitter
    • Dual alarm operation lets you perform two alarm functions at the same time

    Learn more about the Intellipack Series and view all models >

  • Specs & Data Sheets

    Manuals

    811A, 812A User Manual (Log in to download the file)

    IntelliPack & Series 900MB Configuration Software Windows 7 or 8 User Manual (Log in to download the file)

    How to Use SIIG USB-to-Serial Cable With Windows Tech Note (Log in to download the file)

    IntelliPack & Series 900 Configuration Software: Windows 10 User Manual (Log in to download the file)

  • Software

    800C-SIP: IntelliPack Configuration Software Information Page (Log in to download the file)
    IntelliPack Configuration Software 5030-881 (Log in to download the file)
  • Accessories

    • Compare

      5020-350: Toroidal AC Current Sensor

      • AC Current Sensor to precondition an AC current input signal
      • Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
      Select options
    • Compare

      800C-SIP: IntelliPack Configuration Software

      • Configuration Software
      • USB-to-RS232 Adapter
      • RS232-to-RJ11 Adapter
      • Interface Cable
      Acromag’s configuration software is the key to the IntelliPack’s easy-to-use operation. The software employs the friendly Windows® interface with pull-down selection menus and fill-in-the-blank fields to speed you through a few brief configuration screens. No programming is required.
      Select options
    • Compare

      PS5R: Slim Line Power Supplies

      • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
      • Universal Input (85-264V AC / 100-370V DC)
      • Lightweight and compact size
       
      Select options
  • Additional information

    Additional information

    Weight 8 oz
    Dimensions 5 × 1.25 × 4.5 in
    Part Number

    811A-0100: one DC voltage/current input, one DPDT relay, 811A-0200: one DC voltage/current input; two SPDT relays, 811A-0200-C: one DC voltage/current input; two SPDT relays, with factory configuration, 812A-0200: Dual alarm; two DC voltage/current inputs, two SPDT relays, 812A-0200-C: Dual alarm; two DC voltage/current inputs, two SPDT relays, with factory configuration

    Configuration

    Windows Software Configuration

    Product Series

    IntelliPack 800A Series

    Power Type

    DC Power, External Power