Click to zoom
$375$415
Clear
Product short description:
  • Thermocouple (J, K, T, R, S, E, B, N), RTD (Pt, Ni, Cu), millivolt (±100mV DC), resistance (0 to 500 ohms) input
  • Single or dual mechanical relay alarm outputs
  • 10-36V DC power
  • Software configured
  • Multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection)
  • On/off controller capability

 

 

 

 

 

[DISPLAY_ULTIMATE_PLUS]

801A Intelligent Alarm, Universal TC/RTD/mV Input Description

IntelliPack alarms compare inputs against user-defined limit set-points to control built-in relays.

Each unit offers a selection of input ranges and alarm functions to handle a broad range of applications. As your needs change, you can easily reconfigure the unit for different ranges or functions.

Alarm functions available on all models include on/off controller, limit alarm, window alarm, deviation alarm, rate-of-change alarm, and peak/valley detection.

Setup is very easy. IntelliPack alarms are configured through a user-friendly Windows 7 or newer program. Field adjustments and re-calibration are quickly performed with front-panel push-buttons and status LEDs. Once configured, IntelliPacks operate independent of any host computer.

Performance

General Input

Analog to Digital (A/D) Converter: 16-bit Σ-Δ A/D converter
Resolution: ±0.005% of span or 0.1°C/ LSB. ADC typically yields resolutions finer than 0.1°C/LSB
Ambient Temperature Effect: Better than ±0.005% of input span per °C or ±1μV, whichever is greater.
Noise Rejection:
Normal Mode: Better than 40dB @ 60Hz
Common Mode: Better than 130dB @ 60Hz
Input Filter: Normal mode filtering, plus digital filtering optimized and fixed per input range within Σ-Δ ADC
Input Response Time: Less than 200mS to 98% of final value for a step change in the input. A software programmable delay can be implemented for filtering transients.
Relay Time Delay: Adjustable alarm delay of up to 25 seconds
Input Over-voltage Protection: Bipolar Transient Voltage Suppressors (TVS)

DC milliVolt Input

DC milliVolt/Voltage Input Ranges: 
±1.0V           ±125mV          ±31.25mV
±500mV     ±62.5mV        ±15.625mV       ±250mV

milliVolt Accuracy: better than ±0.05% of input span

Thermocouple Input

Thermocouple Input Ranges
Thermocouple type user configured. Signal linearization, cold-junction compensation, and open circuit or lead break detection are included.
TC             °C Range (°F Range)                     Accuracy
J        -210 to  760°C (-346 to 1400°F)              ±0.5°C
K       -200 to 1372°C (-328 to 2502°F)             ±0.5°C
T       -260 to  400°C (-436 to 752°F)                 ±0.5°C
R         -50 to 1768°C (-58 to 3214°F)                ±1.0°C
S         -50 to 1768°C (-58 to 3214°F)                ±1.0°C
E       -200 to 1000°C (-328 to 1832°F)             ±0.5°C
B        260 to 1820°C (500 to 3308°F)               ±1.0°C
N      -230 to 1300°C (-382 to 2372°F)             ±0.5°C

RTD Input

RTD Input Ranges: 100Ω Pt, 120Ω Ni, or 10Ω Cu; user-configured

RTD                °C Range (°F Range)                       Accuracy
Pt1            -200 to 850°C (-328 to 1562°F)              ±0.25°C
Pt2            -200 to 850°C (-328 to 1562°F)               ±0.25°C
Ni                 -80 to 320°C (-112 to 608°F)                 ±0.25°C
Cu             -200 to 260°C (-328 to 500°F)                 ±1.00°C
Alpha: Pt1 (a = 1.3850), Pt2 (a = 1.3911), Ni (a = 1.6720), Cu (a = 1.4272)
2, 3, or 4-wire configurations supported. Module provides sensor excitation, linearization, lead-wire compensation, and sensor break detection.

RTD Excitation Current:
1mA DC typical, all types
RTD Lead-Wire Compensation: 25 ohms per lead
RTD Break Detection: Configurable for either upscale or downscale

Resistance Input

Resistance Input Range: 0 to 500 ohms
Resistance Accuracy: ±0.05 ohms

Output

Relay (801A-0100 models):
One DPDT electro-mechanical relay
Contact material Silver Nickel (AgNi 90/10)
Relays (801A-0200 models):
Two independent SPDT electro-mechanical relays
Contact material Silver-Cadmium Oxide (AgCdO)
Relay Ratings (CSA ratings):
25V DC @ 5A
120/240V AC @ 5A
Expected Mechanical Life: 20 million operations

Environmental

Ambient Temperature:
Operating: -25 to 70°C (-13 to 158°F)
Storage: -40 to 85°C (-40 to 185°F)
Relative Humidity: 5 to 95%
Power Requirements: 10 to 36V DC. 55mA @ 24V. 75mA @ 15V.
Isolation:
3-way (input/output/power)
1500V AC for 60 seconds or 250V AC continuous
Radiated Field Immunity (RFI): EN61000-4-3, EN50082-1
Electromagnetic Field Immunity (EMI):
No relay trips will occur beyond ±0.25% of input span from set-point under the influence of electromagnetic fields from switching solenoids, commutator motors, and drill motors.
Electrical Fast Transient (EFT): EN61000-4-4, EN50082-1
Surge Withstanding Capability (SWC): EN61000-4-5, EN50082-1
Electrostatic Discharge (ESD): EN61000-4-2, EN50082-1
Radiated Emissions: EN50081-1 for Class B equipment
Approvals:
UL, cUL listed (USA, Canada)
UL3121 – general product safety

Configuration

Software Configuration: Units are fully programmable via the Windows 7 or newer IntelliPack Configuration Program. Configuration downloads from PC through EIA232 serial port using Acromag 800C-SIP kit.
Field Configuration: Setpoint and deadband are configurable via push-buttons and a standard calibrator.
LED Indicators: LEDs indicate power, status, and alarm.

Physical

Enclosure: Case: Self-extinguishing NYLON type 6.6 polyamide thermoplastic UL94 V-2, color beige; general purpose NEMA Type 1 enclosure.
Connectors (Removable terminal blocks): Wire Range: AWG #14-22 (AWG #12 stranded only)
Printed Circuit Boards: Military grade FR-4 epoxy glass circuit board
Dimensions
1.05W x 4.68H x 4.35D inches
26.7W x 118.9H x 110.5D millimeters
Shipping Weight: 1 pound (0.45 Kg) packed

 

  • Integrated micro-controller performs intelligent signal processing for advanced alarm functions
  • Windows 7 or newer software configuration speeds setup and replacement
  • Push-button re-programmability facilitates changes in the field without a host PC
  • Multi-purpose inputs accept numerous ranges to reduce spare stock requirements
  • High-resolution Sigma-Delta A/D converter delivers high accuracy with low noise
  • Input excitation supply on each input provides power for a two-wire transmitter
  • Dual alarm operation lets you perform two alarm functions at the same time
  • -25 to 70°C (-13 to 158°F) operation

 

 

 

 

 

 

How to Use an AC Current Sensor Application Note
Using Acromag’s AC Current Sensor Model 5020-350 Transmitters with DC current input can be used used in conjunction with an external AC Current Sensor to precondition an AC current input signal. This sensor is a highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low-level, DC milliampere signal (0 to 11.17mA)....

Manuals

801A User Manual (Log in to download the file)

IntelliPack Alarm Configuration Software User Manual Model 5030-881 (Log in to download the file)

How to Use SIIG USB-to-Serial Cable With Windows Tech Note (Log in to download the file)

IntelliPack Configuration Software 5030-881 (Log in to download the file)
  • Compare

    20RM-16-DIN: 19” rack-mount kit with DIN rail

    • 19" rack-mount kit with DIN rail
    $185
    Select options
  • Compare

    4001-095: USB-to-Serial Adapter

    • USB-to-serial adapter
    • Easy to use to setup and re-configure modules
    $40
    Select options
  • Compare

    5020-350: Toroidal AC Current Sensor

    • AC Current Sensor to precondition an AC current input signal
    • Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
    $50
    Select options
  • Compare

    5030 Cable Series

    • Various specialty cables
    $20$90
    Select options
  • Compare

    5030-881

    • IntelliPack 800 Series software on CD-ROM
    $60
    Select options
  • Compare

    800C-SIP: IntelliPack Configuration Software

    • Configuration Software
    • USB-to-RS232 Adapter
    • RS232-to-RJ11 Adapter
    • Interface Cable
         
    $300
    Select options
  • Compare

    PS5R: Slim Line Power Supplies

    • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
    • Universal Input (85-264V AC / 100-370V DC)
    • Lightweight and compact size
    $95$245
    Select options
  • Compare

    Terminal Block Replacements

    • Simplifies wiring connections on Acromag I/O Modules
    • Barrier strip or spring clamp terminal block kits
    • Provide safe and secure wiring connections
    $30$40
    Select options

Additional information

Weight 11 oz
Dimensions 5 × 1.25 × 4.5 in
Part Number

801A-0100: DPDT relay, 801A-0100-C: factory configuration, 801A-0200: two SPDT relays, 801A-0200-C: two SPDT relays; factory configuration

Configuration

Windows Software Configuration

Product Series

IntelliPack 800 Series

Power

DC Power, External Power

  • Description

    801A Intelligent Alarm, Universal TC/RTD/mV Input Description

    IntelliPack alarms compare inputs against user-defined limit set-points to control built-in relays.

    Each unit offers a selection of input ranges and alarm functions to handle a broad range of applications. As your needs change, you can easily reconfigure the unit for different ranges or functions.

    Alarm functions available on all models include on/off controller, limit alarm, window alarm, deviation alarm, rate-of-change alarm, and peak/valley detection.

    Setup is very easy. IntelliPack alarms are configured through a user-friendly Windows 7 or newer program. Field adjustments and re-calibration are quickly performed with front-panel push-buttons and status LEDs. Once configured, IntelliPacks operate independent of any host computer.

    Performance

    General Input

    Analog to Digital (A/D) Converter: 16-bit Σ-Δ A/D converter
    Resolution: ±0.005% of span or 0.1°C/ LSB. ADC typically yields resolutions finer than 0.1°C/LSB
    Ambient Temperature Effect: Better than ±0.005% of input span per °C or ±1μV, whichever is greater.
    Noise Rejection:
    Normal Mode: Better than 40dB @ 60Hz
    Common Mode: Better than 130dB @ 60Hz
    Input Filter: Normal mode filtering, plus digital filtering optimized and fixed per input range within Σ-Δ ADC
    Input Response Time: Less than 200mS to 98% of final value for a step change in the input. A software programmable delay can be implemented for filtering transients.
    Relay Time Delay: Adjustable alarm delay of up to 25 seconds
    Input Over-voltage Protection: Bipolar Transient Voltage Suppressors (TVS)

    DC milliVolt Input

    DC milliVolt/Voltage Input Ranges: 
    ±1.0V           ±125mV          ±31.25mV
    ±500mV     ±62.5mV        ±15.625mV       ±250mV

    milliVolt Accuracy: better than ±0.05% of input span

    Thermocouple Input

    Thermocouple Input Ranges
    Thermocouple type user configured. Signal linearization, cold-junction compensation, and open circuit or lead break detection are included.
    TC             °C Range (°F Range)                     Accuracy
    J        -210 to  760°C (-346 to 1400°F)              ±0.5°C
    K       -200 to 1372°C (-328 to 2502°F)             ±0.5°C
    T       -260 to  400°C (-436 to 752°F)                 ±0.5°C
    R         -50 to 1768°C (-58 to 3214°F)                ±1.0°C
    S         -50 to 1768°C (-58 to 3214°F)                ±1.0°C
    E       -200 to 1000°C (-328 to 1832°F)             ±0.5°C
    B        260 to 1820°C (500 to 3308°F)               ±1.0°C
    N      -230 to 1300°C (-382 to 2372°F)             ±0.5°C

    RTD Input

    RTD Input Ranges: 100Ω Pt, 120Ω Ni, or 10Ω Cu; user-configured

    RTD                °C Range (°F Range)                       Accuracy
    Pt1            -200 to 850°C (-328 to 1562°F)              ±0.25°C
    Pt2            -200 to 850°C (-328 to 1562°F)               ±0.25°C
    Ni                 -80 to 320°C (-112 to 608°F)                 ±0.25°C
    Cu             -200 to 260°C (-328 to 500°F)                 ±1.00°C
    Alpha: Pt1 (a = 1.3850), Pt2 (a = 1.3911), Ni (a = 1.6720), Cu (a = 1.4272)
    2, 3, or 4-wire configurations supported. Module provides sensor excitation, linearization, lead-wire compensation, and sensor break detection.

    RTD Excitation Current:
    1mA DC typical, all types
    RTD Lead-Wire Compensation: 25 ohms per lead
    RTD Break Detection: Configurable for either upscale or downscale

    Resistance Input

    Resistance Input Range: 0 to 500 ohms
    Resistance Accuracy: ±0.05 ohms

    Output

    Relay (801A-0100 models):
    One DPDT electro-mechanical relay
    Contact material Silver Nickel (AgNi 90/10)
    Relays (801A-0200 models):
    Two independent SPDT electro-mechanical relays
    Contact material Silver-Cadmium Oxide (AgCdO)
    Relay Ratings (CSA ratings):
    25V DC @ 5A
    120/240V AC @ 5A
    Expected Mechanical Life: 20 million operations

    Environmental

    Ambient Temperature:
    Operating: -25 to 70°C (-13 to 158°F)
    Storage: -40 to 85°C (-40 to 185°F)
    Relative Humidity: 5 to 95%
    Power Requirements: 10 to 36V DC. 55mA @ 24V. 75mA @ 15V.
    Isolation:
    3-way (input/output/power)
    1500V AC for 60 seconds or 250V AC continuous
    Radiated Field Immunity (RFI): EN61000-4-3, EN50082-1
    Electromagnetic Field Immunity (EMI):
    No relay trips will occur beyond ±0.25% of input span from set-point under the influence of electromagnetic fields from switching solenoids, commutator motors, and drill motors.
    Electrical Fast Transient (EFT): EN61000-4-4, EN50082-1
    Surge Withstanding Capability (SWC): EN61000-4-5, EN50082-1
    Electrostatic Discharge (ESD): EN61000-4-2, EN50082-1
    Radiated Emissions: EN50081-1 for Class B equipment
    Approvals:
    UL, cUL listed (USA, Canada)
    UL3121 – general product safety

    Configuration

    Software Configuration: Units are fully programmable via the Windows 7 or newer IntelliPack Configuration Program. Configuration downloads from PC through EIA232 serial port using Acromag 800C-SIP kit.
    Field Configuration: Setpoint and deadband are configurable via push-buttons and a standard calibrator.
    LED Indicators: LEDs indicate power, status, and alarm.

    Physical

    Enclosure: Case: Self-extinguishing NYLON type 6.6 polyamide thermoplastic UL94 V-2, color beige; general purpose NEMA Type 1 enclosure.
    Connectors (Removable terminal blocks): Wire Range: AWG #14-22 (AWG #12 stranded only)
    Printed Circuit Boards: Military grade FR-4 epoxy glass circuit board
    Dimensions
    1.05W x 4.68H x 4.35D inches
    26.7W x 118.9H x 110.5D millimeters
    Shipping Weight: 1 pound (0.45 Kg) packed

     

  • Features & Benefits

    • Integrated micro-controller performs intelligent signal processing for advanced alarm functions
    • Windows 7 or newer software configuration speeds setup and replacement
    • Push-button re-programmability facilitates changes in the field without a host PC
    • Multi-purpose inputs accept numerous ranges to reduce spare stock requirements
    • High-resolution Sigma-Delta A/D converter delivers high accuracy with low noise
    • Input excitation supply on each input provides power for a two-wire transmitter
    • Dual alarm operation lets you perform two alarm functions at the same time
    • -25 to 70°C (-13 to 158°F) operation

     

     

     

     

     

     

  • Tech Papers

    How to Use an AC Current Sensor Application Note
    Using Acromag’s AC Current Sensor Model 5020-350 Transmitters with DC current input can be used used in conjunction with an external AC Current Sensor to precondition an AC current input signal. This sensor is a highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low-level, DC milliampere signal (0 to 11.17mA)....
  • Specs & Data Sheets

    Manuals

    801A User Manual (Log in to download the file)

    IntelliPack Alarm Configuration Software User Manual Model 5030-881 (Log in to download the file)

    How to Use SIIG USB-to-Serial Cable With Windows Tech Note (Log in to download the file)

  • Software

    IntelliPack Configuration Software 5030-881 (Log in to download the file)
  • Accessories

    • Compare

      20RM-16-DIN: 19” rack-mount kit with DIN rail

      • 19" rack-mount kit with DIN rail
      $185
      Select options
    • Compare

      4001-095: USB-to-Serial Adapter

      • USB-to-serial adapter
      • Easy to use to setup and re-configure modules
      $40
      Select options
    • Compare

      5020-350: Toroidal AC Current Sensor

      • AC Current Sensor to precondition an AC current input signal
      • Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
      $50
      Select options
    • Compare

      5030 Cable Series

      • Various specialty cables
      $20$90
      Select options
    • Compare

      5030-881

      • IntelliPack 800 Series software on CD-ROM
      $60
      Select options
    • Compare

      800C-SIP: IntelliPack Configuration Software

      • Configuration Software
      • USB-to-RS232 Adapter
      • RS232-to-RJ11 Adapter
      • Interface Cable
           
      $300
      Select options
    • Compare

      PS5R: Slim Line Power Supplies

      • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
      • Universal Input (85-264V AC / 100-370V DC)
      • Lightweight and compact size
      $95$245
      Select options
    • Compare

      Terminal Block Replacements

      • Simplifies wiring connections on Acromag I/O Modules
      • Barrier strip or spring clamp terminal block kits
      • Provide safe and secure wiring connections
      $30$40
      Select options
  • Additional information

    Additional information

    Weight 11 oz
    Dimensions 5 × 1.25 × 4.5 in
    Part Number

    801A-0100: DPDT relay, 801A-0100-C: factory configuration, 801A-0200: two SPDT relays, 801A-0200-C: two SPDT relays; factory configuration

    Configuration

    Windows Software Configuration

    Product Series

    IntelliPack 800 Series

    Power

    DC Power, External Power