965EN: Ethernet Thermocouple milliVolt Input Modules
Please sign in or register to see model options and to add products to your cart.
Product short description:
- 4 or 6-channel thermocouple/milliVolt input
- Ethernet/IP, Modbus TCP/IP
- i2o peer-to-peer available for Modbus TCP/IP 6-channel only
These modules provide an isolated Ethernet network interface for up to six input channels. Differential inputs eliminate ground noise and each terminal block includes a cold junction compensation (CJC) sensor for more precise temperature measurements. Multi-range inputs accept signals from a variety of sensors and devices. High-resolution, low noise, A/D converters deliver high accuracy and reliability.
965EN: Ethernet Thermocouple milliVolt Input Modules Description
These modules provide an isolated Ethernet network interface for up to six input channels. Differential inputs eliminate ground noise and each terminal block includes a cold junction compensation (CJC) sensor for more precise temperature measurements.
Multi-range inputs accept signals from a variety of sensors and devices. High-resolution, low noise, A/D converters deliver high accuracy and reliability.
Input Ranges:Â Ranges are selectable for a 3-channel group.
Thermocouple (user-selectable type) Type J, K, T, R, S, E, B, or N.
DC Millivolts (user-selectable range) ±100mV or ±1V DC.
Network Communication:
Ethernet/IP
Modbus TCP/IP, (i2o® peer-to-peer available for Modbus TCP/IP 6-channel only)
10/100Mbps with automatic data rate negotiation.
Power Requirement: 15 to 36V DC supply (2 Watts) required.
Approvals:
CE/ATEX marked
UL, cUL listed, Class I; Div. 2; Groups A, B, C, D
EtherNet/IP, Modbus/TCP conformance tested
Learn more about the Ethernet 900EN TC/mV Series and view all models >
965EN: Ethernet Temperature Input Modules Features & Benefits
- Configurable from standard web browser
- EtherNet/IP® or Ethernet Modbus TCP/IP communication with automatic 10/100Mbps data rate negotiation
- 6-input stand-alone module is very economical
- i2o function (available ONLY with Modbus TCP/IP 6-channel) enables direct input-to-output communication without a network controller
- Universal inputs support a variety of sensors
- Built-in CJC sensor on each terminal block produces more precise temperature measurements
- Thermocouple break detection (upscale or downscale) identifies sensor wiring failures
- High-resolution 16-bit sigma-delta A/D converters ensure precise, high accuracy measurements
- Compact packaging with pluggable terminals
- Wide operational temperature range: -25°C to 70°C (-13° to 158°F)
- Approvals: CE/ATEX marked; UL, cUL listed, Class 1 Div 2 Groups A, B, C, D; EtherNet/IP, Modbus/TCP conformance tested
Specifications
Manuals
-
5035 Series: Ethernet Cables
- Ethernet straight cable, CAT5
- Ethernet crossover cable, CAT5E
- Low EMI Double-Shielded Ethernet Patch Cable
Additional information
Weight | 10 oz |
---|---|
Dimensions | 4.5 × 1.5 × 5 in |
Part Number | 965EN-4004: Ethernet Modbus TCP/IP, 4 channel, 965EN-4006: Ethernet Modbus TCP/IP and i2o protocol, 6 channel, 965EN-6004: Ethernet/IP Analog: 4 channel, 965EN-6006: Ethernet/IP, 6 channel |
Communication | Ethernet/IP, i2o Peer-to-Peer, Modbus TCP/IP |
Product Series | BusWorks 900EN Series |
Configuration | Built-in Web pages |
-
Description
965EN: Ethernet Thermocouple milliVolt Input Modules Description
These modules provide an isolated Ethernet network interface for up to six input channels. Differential inputs eliminate ground noise and each terminal block includes a cold junction compensation (CJC) sensor for more precise temperature measurements.
Multi-range inputs accept signals from a variety of sensors and devices. High-resolution, low noise, A/D converters deliver high accuracy and reliability.
Input Ranges:Â Ranges are selectable for a 3-channel group.
Thermocouple (user-selectable type) Type J, K, T, R, S, E, B, or N.
DC Millivolts (user-selectable range) ±100mV or ±1V DC.Network Communication:
Ethernet/IP
Modbus TCP/IP, (i2o® peer-to-peer available for Modbus TCP/IP 6-channel only)
10/100Mbps with automatic data rate negotiation.Power Requirement: 15 to 36V DC supply (2 Watts) required.
Approvals:
CE/ATEX marked
UL, cUL listed, Class I; Div. 2; Groups A, B, C, D
EtherNet/IP, Modbus/TCP conformance testedLearn more about the Ethernet 900EN TC/mV Series and view all models >
965EN: Ethernet Temperature Input Modules Features & Benefits
- Configurable from standard web browser
- EtherNet/IP® or Ethernet Modbus TCP/IP communication with automatic 10/100Mbps data rate negotiation
- 6-input stand-alone module is very economical
- i2o function (available ONLY with Modbus TCP/IP 6-channel) enables direct input-to-output communication without a network controller
- Universal inputs support a variety of sensors
- Built-in CJC sensor on each terminal block produces more precise temperature measurements
- Thermocouple break detection (upscale or downscale) identifies sensor wiring failures
- High-resolution 16-bit sigma-delta A/D converters ensure precise, high accuracy measurements
- Compact packaging with pluggable terminals
- Wide operational temperature range: -25°C to 70°C (-13° to 158°F)
- Approvals: CE/ATEX marked; UL, cUL listed, Class 1 Div 2 Groups A, B, C, D; EtherNet/IP, Modbus/TCP conformance tested
-
Tech Papers
How to Set Up Communications between HMI and Remote I/O Demo - 8400643Demo Program: How to Set Up Communications between IDEC HMI and Acromag 965EN Scope To establish communications between an IDEC HG3G HMI, set up as a Modbus/TCP master, and Acromag’s 965EN Remote I/O, set up as a Modbus/TCP slave. IDEC HMI Setup Projects for IDEC’s HG3G series of HMIs are created with WindO/I-NV2 software. To...How to Connect Ethernet I/O Modules with RadioLinx Ethernet Modems - 8500770Connecting Acromag Series 900EN I/O Modules to an existing network with RadioLinx Ethernet Modems Background – IP Addresses Any TCP/IP packet contains two addresses: a unique fixed MAC address, and a unique IP address. To communicate on the Internet, computers must have unique identifiers in order to differentiate one computer from another. This is accomplished...How to Communicate with Modbus/TCP Modules from Ignition Software - 8501121Setting Up and Communicating with Acromag Series 9xxEN-40xx and XTxxx1-xxx Modbus/TCP Modules and EtherStax™ Modbus/TCP from Ignition Software This document illustrates a procedure for configuring OPC tags intended for Acromag BusWorks® Series Modbus/TCP modules using Windows software from Inductive Automation. It is assumed that the user has a working knowledge of OPC, Modbus TCP, and...How to Connect to Acromag Ethernet I/O Devices - 8500815Getting Connected to Acromag Ethernet I/O Devices These instructions summarize the basic steps you will have to take in order to initially connect an Acromag Ethernet I/O product to your Personal Computer (PC) or laptop. To connect an Ethernet device to your PC, consult with your network administrator. Either temporarily change the TCP/IP configuration of...How to Connect Acromag 900EN Ethernet Modules to Your PC - 8500734Connecting Acromag Series 900EN Ethernet Modules to Your PC Objective: The purpose of this document is to provide a procedure for assigning a unique IP address to a second network interface card installed in a personal computer for the purpose of communicating with an Acromag Series 9xxEN Ethernet I/O Module. A procedure for accomplishing IP address... -
Specs & Data Sheets
Specifications
Manuals
-
Software
-
Accessories
-
5035 Series: Ethernet Cables
- Ethernet straight cable, CAT5
- Ethernet crossover cable, CAT5E
- Low EMI Double-Shielded Ethernet Patch Cable
-
-
Additional information
Additional information
Weight 10 oz Dimensions 4.5 × 1.5 × 5 in Part Number 965EN-4004: Ethernet Modbus TCP/IP, 4 channel, 965EN-4006: Ethernet Modbus TCP/IP and i2o protocol, 6 channel, 965EN-6004: Ethernet/IP Analog: 4 channel, 965EN-6006: Ethernet/IP, 6 channel
Communication Ethernet/IP, i2o Peer-to-Peer, Modbus TCP/IP
Product Series BusWorks 900EN Series
Configuration Built-in Web pages