  • 48 Channel-Isolated Discrete I/O (32 DC inputs, 16 AC/DC outputs)
  • Modbus TCP/IP, i20 peer-to-peer

EtherStax I/O blocks provide a ruggedized, high-density solution to interface a large quantity of isolated discrete I/O signals to your control system. A stackable aluminum housing maintains a small footprint and stands up to harsh, industrial environments. Web-based configuration simplifies setup with any web browser.

EtherStax I/O blocks provide a ruggedized, high-density solution to interface a large quantity of isolated discrete I/O signals to your control system. A stackable aluminum housing maintains a small footprint and stands up to harsh, industrial environments. Web-based configuration simplifies setup with any web browser.

Performance Specifications

Inputs

Configuration: 32 individually isolated, buffered inputs grouped in two 16-ch ports. Active-high operation.
Input Voltage Range: 20-32V DC, 36V DC max
Max voltage/operating temperature: 36V DC @ 65°C maximum
Input Signal Threshold and Hysteresis: OFF-ON: 13V min, 20V max, 16V DC typical. ON-OFF: 11V max, 7V min, 9V DC typical.
Input Impedance: 6k ohms
Input Isolation: Channel-to-channel: 150V AC isolation rating. Port-to-port: 250V AC safety isolation rating.
Input Response Time: Less than 5ms
Peer-to-peer (i2o) communication: Change-of-state updates: Less than 10ms events. Timed updates: Configurable for 1-90 seconds.

Outputs

Configuration: One 16-ch port of isolated SPST-NO mech. relays
Maximum Switching Voltage / Load Rating: 250V AC, 110V DC @ 2A
Mechanical Life: 20 million operations minimum
Electrical Life (@ 20 cycles per minute): 100k operations minimum at 2A
Contact Resistance (Initial): 30 milliohms, maximum
Output Response Time: Less than 5ms
Minimum Load: 100μA/100mV DC

Local Alarm Output

Configuration: Failsafe or non-failsafe (software-configurable) relay trips on power or link-loss failure.
Type: SPST-NO, 1 Form A, Class I, Division II approved.
Maximum Switching Voltage/Load Rating: 240V AC, 125V DC @ 2A. 100K operations minimum.

Ethernet Interface

Internal Switch or Hub/Repeater: Dual-port Ethernet switch. Web-configurable as a true switch (default mode) or low-latency hub.
Network Connector [10/100 Base-T(X)Copper]: One or two 8-pin RJ-45 connectors. Automatic MDI/MDI-X. 100m communication distance.
Network Connector (100 Base-FX Fiber-optic): One multi-mode with SC connector. 2km communication distance. Full/half-duplex, selectable.
Protocols and Addressing: Modbus TCP/IP or UDP/IP. i2o peer-to-peer. StaticIP, DHCP, BootP. Configurable IP addresses.
Ethernet Modbus TCP/IP Sockets/Sessions: 1-10 socket/sessions programmable via web page.
Ethernet Redundancy: Compatible with STP, RSTP, proprietary schemes.

Environmental

Operating Temperature: -40 to 65°C
Storage Temperature: -40 to 85°C (-40 to 185°F)
Power Requirements: 18-36V DC. Redundant, diode-coupled terminals. 4.7W (copper ports), 6.0W (fiber-optic ports).
Isolation: I/O, power, relay and Ethernet port-to-port
Peak: 1500V AC, ANSI/ISA-82.01-1988
Continuous: 250V AC, 354V DC (150V AC ch-ch)
See User Manual for full temperature specs.

Enclosure and Physical

Housing Classification and Dimensions: IP20: 8.226” x 2.444” x 7.25”, 4 lbs. packed. PCB: 7.920” x 1.875” x 7.25”, 1.65 lbs. packed.
Safety Approvals (pending): UL/cUL Listed
Hazardous Locations: Class I; Div 2; A, B, C, D
Open board units: UL Recognized
Shock and Vibration Immunity (in enclosure): Mechanical Shock: 50g (3ms), 30g (11ms). Random Vibration: 5g, (5-500Hz)

  • Fully isolated between all circuits: Inputs, outputs, alarm, network ports, enclosure, and power are isolated from each other for safety and noise immunity.
  • High-density stackable unit: Stacked mounting puts a lot of I/O in a very small footprint to save panel space.
  • Modbus TCP/IP or UDP/IP protocol: I/O functions as slave to host controller.
  • Peer-to-peer i2o communication: Inputs to one unit automatically actuate outputs on another over Ethernet link.
  • Channel-to channel input isolation: Inputs provide high or low-side sensing for AC or DC circuits.
  • Automatic change of state detection: Inputs detect quick momentary changes of state that occur between polling.
  • Logic inversion (i2o only): Active high inputs can switch remote peer-to-peer outputs on or off.
  • Change-of-state or timed updates: Event-driven updates transmit data in less than 10ms between peers with i2o.
  • 10 Modbus TCP/IP sockets/sessions: Multiple masters can talk to an EtherStax unit at the same time.
  • Local alarm function: Dedicated failsafe relay is controlled via watchdog timer and link-loss conditions.
  • Heavy-duty 2A relays: 16 SPST outputs provide high/low-side 2A switching up to 250V AC or 110V DC.
  • Programmable outputs: Normally open relays are configurable to energize or de-energize on power-up.
  • Built-in slave relays: Inputs can control outputs on same unit to provide slave relay interface.
  • Self-test checks I/O operation: Unit checks internal I/O communication and allows verification via web browser.
  • Watchdog timers: Communication fault sends output to a pre-defined state or holds the last value.
How to Communicate with Modbus/TCP Modules from Ignition Software - 8501121
Setting Up and Communicating with Acromag Series 9xxEN-40xx and XTxxx1-xxx Modbus/TCP Modules and EtherStax™ Modbus/TCP from Ignition Software This document illustrates a procedure for configuring OPC tags intended for Acromag BusWorks® Series Modbus/TCP modules using Windows software from Inductive Automation. It is assumed that the user has a working knowledge of OPC, Modbus TCP, and...
How to Configure LabVIEW to Communicate with Modbus I/O Modules Via an OPC Server - 8500881
Configuring LabVIEW 2009 to Communicate with Acromag BusWorks and EtherStax Modbus I/O Modules via an OPC Server Introduction National Instruments™ LabVIEW can be used to monitor and control Acromag BusWorks ® and EtherStax ® Modbus I/O modules via an OPC server. A separate application note, Configuring Kepware KEPServerEX® 5.0 for communications with Acromag BusWorks and EtherStax...
AMTN-DEMO (Log in to download the file)
ATMX Demo Software (Log in to download the file)
ESW-MBLIB-DEMO (Log in to download the file)
Ethernet IP EDS For XTxxx2-000 Modules (Log in to download the file)
EtherStax Modbus Copy Utility Software (Log in to download the file)
  • Compare

    20RM-16-DIN: 19” rack-mount kit with DIN rail

    • 19" rack-mount kit with DIN rail
    Select options
  • Compare

    4001 Serial Cables

    5-foot ribbon cable, DB25 male and 26-pin female IDC connectors, for 3B/5B backpanel to Ethernet I/O module connection
    Select options
  • Compare

    5020-350: Toroidal AC Current Sensor

    • AC Current Sensor to precondition an AC current input signal
    • Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
    Select options
  • Compare

    5035 Series: Ethernet Cables

    • Ethernet straight cable, CAT5
    • Ethernet crossover cable, CAT5E
    • Low EMI Double-Shielded Ethernet Patch Cable
    Select options
  • Compare

    AMTN, AMTX: ActiveX / .NET Controls for Modbus I/O

    • Modbus/TCP or Modbus/RTU
    • These ActiveX / .NET software controls provide a fast, easy way to communicate with any Modbus slave devices connected to your PC.
    • Get your Visual Basic, Visual C, .NET, Excel, or other compatible applications talking Modbus protocol within minutes.
    Select options
  • Compare

    DIN Rail: Type T

    • DIN Rail Strip, Type T
    Select options
  • Compare

    ESW-MBLIB: Ethernet Modbus C Library Software

    • Universal support for five operating systems
    • C source code provided
    • Demo program included
    Select options
  • Compare

    EtherStax Mounting Kits

    • EtherStax mounting accessories
    Select options
  • Compare

    IMC-100A: 10/100BaseTX to 100BaseFX Industrial Media Converter

    • UTP to Fiber Media Converter
    • RJ45 Port Supports Auto MDI/MDI-X Function
     
    Select options
  • Compare

    PS5R: Slim Line Power Supplies

    • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
    • Universal Input (85-264V AC / 100-370V DC)
    • Lightweight and compact size
     
    Select options
  • Compare

    Terminal Block Replacements

    • Simplifies wiring connections on Acromag I/O Modules
    • Barrier strip or spring clamp terminal block kits
    • Provide safe and secure wiring connections
    Select options
  • Compare

    USB-to-Ethernet Adapter

    Simplifies configuration of Acromag Ethernet I/O Modules Prevents disruption of existing LANs This device is a USB-to-Ethernet adapter that you can use to communicate with any Acromag Ethernet I/O product for the purpose of setup and re-configuration for your application. It is recommended for initial communication with Acromag Ethernet devices so that you do not have to disrupt your existing network connection.
    Select options

Additional information

Weight 80 oz
Dimensions 9 × 2.5 × 7.25 in
Part Number

ES2117-0000: 2 Cu ports, enclosure, ES2117-0010: 2 Cu ports, open PC board, ES2117-1000: 2 Cu/FO ports, enclosure, ES2117-1010: 2 Cu/FO ports, open PC board

Communication

i2o Peer-to-Peer, Modbus TCP/IP, Modbus UDP/IP

Product Series

EtherStax Series

  • Description

    EtherStax I/O blocks provide a ruggedized, high-density solution to interface a large quantity of isolated discrete I/O signals to your control system. A stackable aluminum housing maintains a small footprint and stands up to harsh, industrial environments. Web-based configuration simplifies setup with any web browser.

    Performance Specifications

    Inputs

    Configuration: 32 individually isolated, buffered inputs grouped in two 16-ch ports. Active-high operation.
    Input Voltage Range: 20-32V DC, 36V DC max
    Max voltage/operating temperature: 36V DC @ 65°C maximum
    Input Signal Threshold and Hysteresis: OFF-ON: 13V min, 20V max, 16V DC typical. ON-OFF: 11V max, 7V min, 9V DC typical.
    Input Impedance: 6k ohms
    Input Isolation: Channel-to-channel: 150V AC isolation rating. Port-to-port: 250V AC safety isolation rating.
    Input Response Time: Less than 5ms
    Peer-to-peer (i2o) communication: Change-of-state updates: Less than 10ms events. Timed updates: Configurable for 1-90 seconds.

    Outputs

    Configuration: One 16-ch port of isolated SPST-NO mech. relays
    Maximum Switching Voltage / Load Rating: 250V AC, 110V DC @ 2A
    Mechanical Life: 20 million operations minimum
    Electrical Life (@ 20 cycles per minute): 100k operations minimum at 2A
    Contact Resistance (Initial): 30 milliohms, maximum
    Output Response Time: Less than 5ms
    Minimum Load: 100μA/100mV DC

    Local Alarm Output

    Configuration: Failsafe or non-failsafe (software-configurable) relay trips on power or link-loss failure.
    Type: SPST-NO, 1 Form A, Class I, Division II approved.
    Maximum Switching Voltage/Load Rating: 240V AC, 125V DC @ 2A. 100K operations minimum.

    Ethernet Interface

    Internal Switch or Hub/Repeater: Dual-port Ethernet switch. Web-configurable as a true switch (default mode) or low-latency hub.
    Network Connector [10/100 Base-T(X)Copper]: One or two 8-pin RJ-45 connectors. Automatic MDI/MDI-X. 100m communication distance.
    Network Connector (100 Base-FX Fiber-optic): One multi-mode with SC connector. 2km communication distance. Full/half-duplex, selectable.
    Protocols and Addressing: Modbus TCP/IP or UDP/IP. i2o peer-to-peer. StaticIP, DHCP, BootP. Configurable IP addresses.
    Ethernet Modbus TCP/IP Sockets/Sessions: 1-10 socket/sessions programmable via web page.
    Ethernet Redundancy: Compatible with STP, RSTP, proprietary schemes.

    Environmental

    Operating Temperature: -40 to 65°C
    Storage Temperature: -40 to 85°C (-40 to 185°F)
    Power Requirements: 18-36V DC. Redundant, diode-coupled terminals. 4.7W (copper ports), 6.0W (fiber-optic ports).
    Isolation: I/O, power, relay and Ethernet port-to-port
    Peak: 1500V AC, ANSI/ISA-82.01-1988
    Continuous: 250V AC, 354V DC (150V AC ch-ch)
    See User Manual for full temperature specs.

    Enclosure and Physical

    Housing Classification and Dimensions: IP20: 8.226” x 2.444” x 7.25”, 4 lbs. packed. PCB: 7.920” x 1.875” x 7.25”, 1.65 lbs. packed.
    Safety Approvals (pending): UL/cUL Listed
    Hazardous Locations: Class I; Div 2; A, B, C, D
    Open board units: UL Recognized
    Shock and Vibration Immunity (in enclosure): Mechanical Shock: 50g (3ms), 30g (11ms). Random Vibration: 5g, (5-500Hz)

  • Features & Benefits

    • Fully isolated between all circuits: Inputs, outputs, alarm, network ports, enclosure, and power are isolated from each other for safety and noise immunity.
    • High-density stackable unit: Stacked mounting puts a lot of I/O in a very small footprint to save panel space.
    • Modbus TCP/IP or UDP/IP protocol: I/O functions as slave to host controller.
    • Peer-to-peer i2o communication: Inputs to one unit automatically actuate outputs on another over Ethernet link.
    • Channel-to channel input isolation: Inputs provide high or low-side sensing for AC or DC circuits.
    • Automatic change of state detection: Inputs detect quick momentary changes of state that occur between polling.
    • Logic inversion (i2o only): Active high inputs can switch remote peer-to-peer outputs on or off.
    • Change-of-state or timed updates: Event-driven updates transmit data in less than 10ms between peers with i2o.
    • 10 Modbus TCP/IP sockets/sessions: Multiple masters can talk to an EtherStax unit at the same time.
    • Local alarm function: Dedicated failsafe relay is controlled via watchdog timer and link-loss conditions.
    • Heavy-duty 2A relays: 16 SPST outputs provide high/low-side 2A switching up to 250V AC or 110V DC.
    • Programmable outputs: Normally open relays are configurable to energize or de-energize on power-up.
    • Built-in slave relays: Inputs can control outputs on same unit to provide slave relay interface.
    • Self-test checks I/O operation: Unit checks internal I/O communication and allows verification via web browser.
    • Watchdog timers: Communication fault sends output to a pre-defined state or holds the last value.
  • Tech Papers

    How to Communicate with Modbus/TCP Modules from Ignition Software - 8501121
    Setting Up and Communicating with Acromag Series 9xxEN-40xx and XTxxx1-xxx Modbus/TCP Modules and EtherStax™ Modbus/TCP from Ignition Software This document illustrates a procedure for configuring OPC tags intended for Acromag BusWorks® Series Modbus/TCP modules using Windows software from Inductive Automation. It is assumed that the user has a working knowledge of OPC, Modbus TCP, and...
    How to Configure LabVIEW to Communicate with Modbus I/O Modules Via an OPC Server - 8500881
    Configuring LabVIEW 2009 to Communicate with Acromag BusWorks and EtherStax Modbus I/O Modules via an OPC Server Introduction National Instruments™ LabVIEW can be used to monitor and control Acromag BusWorks ® and EtherStax ® Modbus I/O modules via an OPC server. A separate application note, Configuring Kepware KEPServerEX® 5.0 for communications with Acromag BusWorks and EtherStax...
  • Specs & Data Sheets

  • Software

    AMTN-DEMO (Log in to download the file)
    ATMX Demo Software (Log in to download the file)
    ESW-MBLIB-DEMO (Log in to download the file)
    Ethernet IP EDS For XTxxx2-000 Modules (Log in to download the file)
    EtherStax Modbus Copy Utility Software (Log in to download the file)
  • Accessories

    • Compare

      20RM-16-DIN: 19” rack-mount kit with DIN rail

      • 19" rack-mount kit with DIN rail
      Select options
    • Compare

      4001 Serial Cables

      5-foot ribbon cable, DB25 male and 26-pin female IDC connectors, for 3B/5B backpanel to Ethernet I/O module connection
      Select options
    • Compare

      5020-350: Toroidal AC Current Sensor

      • AC Current Sensor to precondition an AC current input signal
      • Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
      Select options
    • Compare

      5035 Series: Ethernet Cables

      • Ethernet straight cable, CAT5
      • Ethernet crossover cable, CAT5E
      • Low EMI Double-Shielded Ethernet Patch Cable
      Select options
    • Compare

      AMTN, AMTX: ActiveX / .NET Controls for Modbus I/O

      • Modbus/TCP or Modbus/RTU
      • These ActiveX / .NET software controls provide a fast, easy way to communicate with any Modbus slave devices connected to your PC.
      • Get your Visual Basic, Visual C, .NET, Excel, or other compatible applications talking Modbus protocol within minutes.
      Select options
    • Compare

      DIN Rail: Type T

      • DIN Rail Strip, Type T
      Select options
    • Compare

      ESW-MBLIB: Ethernet Modbus C Library Software

      • Universal support for five operating systems
      • C source code provided
      • Demo program included
      Select options
    • Compare

      EtherStax Mounting Kits

      • EtherStax mounting accessories
      Select options
    • Compare

      IMC-100A: 10/100BaseTX to 100BaseFX Industrial Media Converter

      • UTP to Fiber Media Converter
      • RJ45 Port Supports Auto MDI/MDI-X Function
       
      Select options
    • Compare

      PS5R: Slim Line Power Supplies

      • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
      • Universal Input (85-264V AC / 100-370V DC)
      • Lightweight and compact size
       
      Select options
    • Compare

      Terminal Block Replacements

      • Simplifies wiring connections on Acromag I/O Modules
      • Barrier strip or spring clamp terminal block kits
      • Provide safe and secure wiring connections
      Select options
    • Compare

      USB-to-Ethernet Adapter

      Simplifies configuration of Acromag Ethernet I/O Modules Prevents disruption of existing LANs This device is a USB-to-Ethernet adapter that you can use to communicate with any Acromag Ethernet I/O product for the purpose of setup and re-configuration for your application. It is recommended for initial communication with Acromag Ethernet devices so that you do not have to disrupt your existing network connection.
      Select options
  • Additional information

    Additional information

    Weight 80 oz
    Dimensions 9 × 2.5 × 7.25 in
    Part Number

    ES2117-0000: 2 Cu ports, enclosure, ES2117-0010: 2 Cu ports, open PC board, ES2117-1000: 2 Cu/FO ports, enclosure, ES2117-1010: 2 Cu/FO ports, open PC board

    Communication

    i2o Peer-to-Peer, Modbus TCP/IP, Modbus UDP/IP

    Product Series

    EtherStax Series