ES2113: Ethernet Discrete I/O Modules
Product short description:
- 96 bi-directional discrete I/O channels
- Modbus TCP/IP, i20 peer-to-peer communication
EtherStax I/O blocks provide a ruggedized, high-density solution to interface a very large quantity of discrete I/O signals to your control system. A stackable aluminum housing maintains a small footprint and stands up to harsh, industrial environments. Web-based configuration simplifies setup with any web browser.
- Description
- Features & Benefits
- Tech Papers
- Specs & Data Sheets
- Software
- Accessories
- Additional information
EtherStax I/O blocks provide a ruggedized, high-density solution to interface a very large quantity of discrete I/O signals to your control system. A stackable aluminum housing maintains a small footprint and stands up to harsh, industrial environments. Web-based configuration simplifies setup with any web browser.
Performance Specifications
Inputs
Configuration (active-low inputs): 96 channels (six 16-ch ports) with a common return (RTN). Each input is connected in tandem with open-drains of output mosfets. Any mix of I/O occurs as all channels are high impedance inputs unless written. Output channels can be read back at any time (loopback monitoring).
Input Signal Voltage Range: 0 to 28VDC, 31V maximum. Surge protected.
Input Threshold Detection and Sensitivity: 4V DC threshold. Level or latching inputs.
Input “Wetting” Current: Built-in current sources switch from 16mA initially (20ms) to 2mA (continuous), default mode. Sources can be changed to 2mA or turned off.
Internal Excitation (default): 6V DC, 400mA
External Excitation: 6 to 28V DC typical. Separate excitation terminal (logic) for each 16-channel port. Internal and external supplies are diode-blocked from each other. Includes reverse polarity protection.
Peer-to-peer (i2o) communication: Change-of-state updates: Less than 5mS events. Timed updates: Configurable for 1-90 seconds.
Outputs
Configuration (low-side switches): 96 channels (six 16-ch ports) of open-drain mosfet switches with common source connection at port RTN terminal. Each output is connected in tandem with buffered inputs.
Output “OFF” Voltage Range: 0 to 28V DC, 31V maximum. Surge protected.
Output “ON” Current Range: 0 to 300mA DC continuous, each output.
Output “ON” Maximum Current: 450mA DC maximum with any 8 channels “on” continuously per 16 channel port
Output Port Maximum Current: 4.8A: 16 channels @ 300mA continuous. 3.6A: 8 channels “off” & 8 channels @ 450mA
Local Alarm Output
Configuration: Isolated relay de-energizes (failsafe) or energizes (non-failsafe) as configured when the watchdog timer detects a media or communication failure.
Type: SPST-NO, 1 Form A, Class I, Division II approved.
Rating: 5A @ 24VDC/250VAC, 6000 cycles resistive. 3A @ 24VDC/250VAC, 100,000 cycles general. 2A @ 24VDC/250V AC, Hazardous locations
Maximum Switching Voltage: 250VAC, 125VDC
Enclosure and Physical
Housing Classification and Dimensions: IP20: 8.226” x 2.444” x 7.25”. 4 lbs. (1.8 kg) packed (unit weighs 3.4 lbs). Without enclosure: 7.920” x 1.875” x 7.25”. 1.65 lbs. (0.75 kg) packed (unit weighs 1.05 lbs)
Safety Approvals: UL/cUL Listed
Hazardous Locations: Class 1; Div. 2; A B C D
Open board units: UL Recognized
Shock and Vibration Immunity: Rating for single surface-mount unit in enclosure
Mechanical Shock: 50g, 3ms, with 3 half-sine shock pulses in each direction along 3 axes (18 shocks), and 30g, 11ms, with 3 half-sine shock pulses in each direction along 3 axes (18 shocks), per IEC60068-2-27
Random Vibration: 5g, 5-500Hz, in 3 axes at 2 hours/axis per IEC60068-2-64
Environmental
Operating Temperature: Open bd, -40 to 75°C(-40 to 167°F) Enclosed bd, -40 to 75°C (all outputs “off”) -40 to 70°C (all outputs “on” at rated Max.)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Power Requirements: 18-36V DC. Redundant, diode-coupled terminals. Dual copper ports: 2.5W with external excitation, 3.5W with internal excitation. Fiber optic units: Call factory.
Isolation: I/O, power, relay and Ethernet port-to-port
Peak: 1500V AC, ANSI/ISA-82.01-1988
Continuous: 250V AC, 354V DC
Ethernet Interface
Internal Switch or Hub/Repeater: Dual-port Ethernet switch. Web-configurable as a true switch (default mode) or hub.
Network Connector [10/100 Base-T(X)Copper]: One or two 8-pin RJ-45 connectors. Automatic MDI/MDI-X. 100m communication distance.
Network Connector (100 Base-FX Fiber-optic): One multi-mode with SC connector. 2km communication distance. Full/half-duplex, selectable.
Protocols and Addressing: Modbus TCP/IP or UDP/IP. i2o peer-to-peer. StaticIP, DHCP, BootP. Configurable IP addresses.
Ethernet Modbus TCP/IP Sockets/Sessions: 1-10 socket/sessions programmable via web page.
Ethernet Redundancy: Compatible with STP, RSTP, proprietary schemes.
- 96 discrete I/O channels: Bi-directional channels support any input/output mix in a single unit.
- High-density stackable unit: Stacked mounting puts a lot of I/O in a very small footprint to save panel space.
- High speed channel updates: Updates all 96 channels in 1mS.
- Modbus TCP/IP or UDP/IP protocol: I/O functions as slave to host controller.
- Peer-to-peer i2o communication: Inputs to one unit automatically update outputs on another over Ethernet link.
- Change-of-state or timed updates: Event-driven updates transmit data in less than 5mS between peers with i2o.
- 10 Modbus TCP/IP sockets/sessions: Multiple masters can talk to an EtherStax unit at the same time.
- Self-test checks I/O operation: Test I/O channels from a web browser before wiring terminals to devices.
- Selectable input “wetting” current: Internal current source eliminates pull-ups and improves dry contact interface.
- Automatic change of state detection: Inputs detect quick momentary changes of state that occur between polling.
- Internal or external port excitation: Selectable source on each 16-channel port simplifies wiring and adds flexibility for use with 5-28V DC logic.
- Loop-back monitoring on all channels: Inputs confirm output states for increased system reliability.
- Watchdog timers and failsafe outputs: Communication fault sends output to a pre-defined state or holds the last value.
- Output open-load detection: Output fault detection is selectable on individual channels.
- Thermal, current, voltage protection: I/O is protected from excessive levels to reduce downtime.
Specs & Catalogs
Manuals
ES2113 User Manual (Log in to download the file)
-
20RM-16-DIN: 19” rack-mount kit with DIN rail
- 19" rack-mount kit with DIN rail
$185Select options -
4001 Serial Cables
5-foot ribbon cable, DB25 male and 26-pin female IDC connectors, for 3B/5B backpanel to Ethernet I/O module connection$95Select options -
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
$50Select options -
5035 Series: Ethernet Cables
- Ethernet straight cable, CAT5
- Ethernet crossover cable, CAT5E
- Low EMI Double-Shielded Ethernet Patch Cable
$40 – $115Select options -
900EN: 5-Port Ethernet Switch
- 10/100Mbps
- 15 to 36V DC power supply required
- Five shielded RJ-45 sockets, 8-pin, 10Base-T / 100Base-TX
$340Select options -
AMTN, AMTX: ActiveX / .NET Controls for Modbus I/O
- Modbus/TCP or Modbus/RTU
- These ActiveX / .NET software controls provide a fast, easy way to communicate with any Modbus slave devices connected to your PC.
- Get your Visual Basic, Visual C, .NET, Excel, or other compatible applications talking Modbus protocol within minutes.
$260 – $350Select options -
IMC-100A: 10/100BaseTX to 100BaseFX Industrial Media Converter
- UTP to Fiber Media Converter
- RJ45 Port Supports Auto MDI/MDI-X Function
$240Select options -
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
$95 – $245Select options -
Terminal Block Replacements
- Simplifies wiring connections on Acromag I/O Modules
- Barrier strip or spring clamp terminal block kits
- Provide safe and secure wiring connections
$30 – $40Select options -
USB-to-Ethernet Adapter
Simplifies configuration of Acromag Ethernet I/O Modules Prevents disruption of existing LANs This device is a USB-to-Ethernet adapter that you can use to communicate with any Acromag Ethernet I/O product for the purpose of setup and re-configuration for your application. It is recommended for initial communication with Acromag Ethernet devices so that you do not have to disrupt your existing network connection.$80Select options
Additional information
Weight | 80 oz |
---|---|
Dimensions | 9 × 2.5 × 7.25 in |
Part Number | ES2113-0000: two copper ports, IP40 enclosure, ES2113-1000: one Cu & one fiber port, IP40 enclosure, ES2113-1010: one Cu & one fiber port, open circuit board, ES2113-0010: two copper ports, open circuit board |
Communication | i2o Peer-to-Peer, Modbus TCP/IP, Modbus UDP/IP |
Product Series | EtherStax Series |
-
Description
EtherStax I/O blocks provide a ruggedized, high-density solution to interface a very large quantity of discrete I/O signals to your control system. A stackable aluminum housing maintains a small footprint and stands up to harsh, industrial environments. Web-based configuration simplifies setup with any web browser.
Performance Specifications
Inputs
Configuration (active-low inputs): 96 channels (six 16-ch ports) with a common return (RTN). Each input is connected in tandem with open-drains of output mosfets. Any mix of I/O occurs as all channels are high impedance inputs unless written. Output channels can be read back at any time (loopback monitoring).
Input Signal Voltage Range: 0 to 28VDC, 31V maximum. Surge protected.
Input Threshold Detection and Sensitivity: 4V DC threshold. Level or latching inputs.
Input “Wetting” Current: Built-in current sources switch from 16mA initially (20ms) to 2mA (continuous), default mode. Sources can be changed to 2mA or turned off.
Internal Excitation (default): 6V DC, 400mA
External Excitation: 6 to 28V DC typical. Separate excitation terminal (logic) for each 16-channel port. Internal and external supplies are diode-blocked from each other. Includes reverse polarity protection.
Peer-to-peer (i2o) communication: Change-of-state updates: Less than 5mS events. Timed updates: Configurable for 1-90 seconds.Outputs
Configuration (low-side switches): 96 channels (six 16-ch ports) of open-drain mosfet switches with common source connection at port RTN terminal. Each output is connected in tandem with buffered inputs.
Output “OFF” Voltage Range: 0 to 28V DC, 31V maximum. Surge protected.
Output “ON” Current Range: 0 to 300mA DC continuous, each output.
Output “ON” Maximum Current: 450mA DC maximum with any 8 channels “on” continuously per 16 channel port
Output Port Maximum Current: 4.8A: 16 channels @ 300mA continuous. 3.6A: 8 channels “off” & 8 channels @ 450mALocal Alarm Output
Configuration: Isolated relay de-energizes (failsafe) or energizes (non-failsafe) as configured when the watchdog timer detects a media or communication failure.
Type: SPST-NO, 1 Form A, Class I, Division II approved.
Rating: 5A @ 24VDC/250VAC, 6000 cycles resistive. 3A @ 24VDC/250VAC, 100,000 cycles general. 2A @ 24VDC/250V AC, Hazardous locations
Maximum Switching Voltage: 250VAC, 125VDCEnclosure and Physical
Housing Classification and Dimensions: IP20: 8.226” x 2.444” x 7.25”. 4 lbs. (1.8 kg) packed (unit weighs 3.4 lbs). Without enclosure: 7.920” x 1.875” x 7.25”. 1.65 lbs. (0.75 kg) packed (unit weighs 1.05 lbs)
Safety Approvals: UL/cUL Listed
Hazardous Locations: Class 1; Div. 2; A B C D
Open board units: UL Recognized
Shock and Vibration Immunity: Rating for single surface-mount unit in enclosure
Mechanical Shock: 50g, 3ms, with 3 half-sine shock pulses in each direction along 3 axes (18 shocks), and 30g, 11ms, with 3 half-sine shock pulses in each direction along 3 axes (18 shocks), per IEC60068-2-27
Random Vibration: 5g, 5-500Hz, in 3 axes at 2 hours/axis per IEC60068-2-64Environmental
Operating Temperature: Open bd, -40 to 75°C(-40 to 167°F) Enclosed bd, -40 to 75°C (all outputs “off”) -40 to 70°C (all outputs “on” at rated Max.)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Power Requirements: 18-36V DC. Redundant, diode-coupled terminals. Dual copper ports: 2.5W with external excitation, 3.5W with internal excitation. Fiber optic units: Call factory.
Isolation: I/O, power, relay and Ethernet port-to-port
Peak: 1500V AC, ANSI/ISA-82.01-1988
Continuous: 250V AC, 354V DCEthernet Interface
Internal Switch or Hub/Repeater: Dual-port Ethernet switch. Web-configurable as a true switch (default mode) or hub.
Network Connector [10/100 Base-T(X)Copper]: One or two 8-pin RJ-45 connectors. Automatic MDI/MDI-X. 100m communication distance.
Network Connector (100 Base-FX Fiber-optic): One multi-mode with SC connector. 2km communication distance. Full/half-duplex, selectable.
Protocols and Addressing: Modbus TCP/IP or UDP/IP. i2o peer-to-peer. StaticIP, DHCP, BootP. Configurable IP addresses.
Ethernet Modbus TCP/IP Sockets/Sessions: 1-10 socket/sessions programmable via web page.
Ethernet Redundancy: Compatible with STP, RSTP, proprietary schemes. -
Features & Benefits
- 96 discrete I/O channels: Bi-directional channels support any input/output mix in a single unit.
- High-density stackable unit: Stacked mounting puts a lot of I/O in a very small footprint to save panel space.
- High speed channel updates: Updates all 96 channels in 1mS.
- Modbus TCP/IP or UDP/IP protocol: I/O functions as slave to host controller.
- Peer-to-peer i2o communication: Inputs to one unit automatically update outputs on another over Ethernet link.
- Change-of-state or timed updates: Event-driven updates transmit data in less than 5mS between peers with i2o.
- 10 Modbus TCP/IP sockets/sessions: Multiple masters can talk to an EtherStax unit at the same time.
- Self-test checks I/O operation: Test I/O channels from a web browser before wiring terminals to devices.
- Selectable input “wetting” current: Internal current source eliminates pull-ups and improves dry contact interface.
- Automatic change of state detection: Inputs detect quick momentary changes of state that occur between polling.
- Internal or external port excitation: Selectable source on each 16-channel port simplifies wiring and adds flexibility for use with 5-28V DC logic.
- Loop-back monitoring on all channels: Inputs confirm output states for increased system reliability.
- Watchdog timers and failsafe outputs: Communication fault sends output to a pre-defined state or holds the last value.
- Output open-load detection: Output fault detection is selectable on individual channels.
- Thermal, current, voltage protection: I/O is protected from excessive levels to reduce downtime.
-
Tech Papers
How to Remotely Control AC Power for a WEB Server Using an Acromag ES2113 or a 989EN-4C16 Ethernet Digital I/O Module Application NoteObjective This document outlines the steps taken to use an ES2113 or 989EN DIO to control a latching relay that is used to open or close the AC power (115 VAC) path used by a multi domain WEB server. In this mode of control the DIO is configured to a static IP address and is...How to Communicate with Acromag Modbus/TCP Modules from Ignition Software Application NoteCommunicating with Ignition Software This document illustrates a procedure for configuring OPC tags intended for Acromag Busworks® Series Modbus/TCP modules using Windows software from Inductive Automation. It is assumed that the user has a working knowledge of OPC, Modbus TCP, and Ignition software. Product Features: BusWorks® Series 9xxEN Modules w/Modbus/TCP BusWorks® Series XT1xx1 Modules w/...How to Configure the Acromag Modbus OPC Server Application NoteConfiguring the Acromag Modbus OPC Server This document illustrates two different procedures for configuring the Acromag Modbus OPC Server to use with any OPC Client application. Configuring the Acromag Modbus OPC Server using CSV Files Start the Acromag Modbus OPC Server by selecting Start-> All Programs-> Acromag OPC-> Modbus TCP Master OPC DA Server-> OPC...How to Configure LabVIEW 2009 to Communicate with Acromag BusWorks and EtherStax Modbus I/O Modules Via an OPC Server Application NoteIntroduction National Instruments LabVIEW can be used to monitor and control Acromag Busworks and Etherstax Modbus I/O Modules via an OPC server. A separate application note, Configuring Kepware KEPServerEX 5.0 for Communications with Acromag Busworks and Etherstax Modbus I/O Modules, outlines configuration of a KEPServerEX OPC server. This document focuses on setting up controls and... -
Specs & Data Sheets
Specs & Catalogs
Manuals
ES2113 User Manual (Log in to download the file)
-
Software
-
Accessories
-
20RM-16-DIN: 19” rack-mount kit with DIN rail
- 19" rack-mount kit with DIN rail
$185Select options -
4001 Serial Cables
5-foot ribbon cable, DB25 male and 26-pin female IDC connectors, for 3B/5B backpanel to Ethernet I/O module connection$95Select options -
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
$50Select options -
5035 Series: Ethernet Cables
- Ethernet straight cable, CAT5
- Ethernet crossover cable, CAT5E
- Low EMI Double-Shielded Ethernet Patch Cable
$40 – $115Select options -
900EN: 5-Port Ethernet Switch
- 10/100Mbps
- 15 to 36V DC power supply required
- Five shielded RJ-45 sockets, 8-pin, 10Base-T / 100Base-TX
$340Select options -
AMTN, AMTX: ActiveX / .NET Controls for Modbus I/O
- Modbus/TCP or Modbus/RTU
- These ActiveX / .NET software controls provide a fast, easy way to communicate with any Modbus slave devices connected to your PC.
- Get your Visual Basic, Visual C, .NET, Excel, or other compatible applications talking Modbus protocol within minutes.
$260 – $350Select options -
IMC-100A: 10/100BaseTX to 100BaseFX Industrial Media Converter
- UTP to Fiber Media Converter
- RJ45 Port Supports Auto MDI/MDI-X Function
$240Select options -
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
$95 – $245Select options -
Terminal Block Replacements
- Simplifies wiring connections on Acromag I/O Modules
- Barrier strip or spring clamp terminal block kits
- Provide safe and secure wiring connections
$30 – $40Select options -
USB-to-Ethernet Adapter
Simplifies configuration of Acromag Ethernet I/O Modules Prevents disruption of existing LANs This device is a USB-to-Ethernet adapter that you can use to communicate with any Acromag Ethernet I/O product for the purpose of setup and re-configuration for your application. It is recommended for initial communication with Acromag Ethernet devices so that you do not have to disrupt your existing network connection.$80Select options
-
-
Additional information
Additional information
Weight 80 oz Dimensions 9 × 2.5 × 7.25 in Part Number ES2113-0000: two copper ports, IP40 enclosure, ES2113-1000: one Cu & one fiber port, IP40 enclosure, ES2113-1010: one Cu & one fiber port, open circuit board, ES2113-0010: two copper ports, open circuit board
Communication i2o Peer-to-Peer, Modbus TCP/IP, Modbus UDP/IP
Product Series EtherStax Series
Please login to submit this form.