ES2113: Ethernet Discrete I/O Modules
Please sign in or register to see model options and to add products to your cart.
Product short description:
- 96 bi-directional discrete I/O channels
- Modbus TCP/IP, i20 peer-to-peer communication
EtherStax I/O blocks provide a ruggedized, high-density solution to interface a very large quantity of discrete I/O signals to your control system. A stackable aluminum housing maintains a small footprint and stands up to harsh, industrial environments. Web-based configuration simplifies setup with any web browser.
ES2113: Ethernet Discrete I/O Modules
EtherStax I/O blocks provide a ruggedized, high-density solution to interface a very large quantity of discrete I/O signals to your control system. A stackable aluminum housing maintains a small footprint and stands up to harsh, industrial environments. Web-based configuration simplifies setup with any web browser.
Learn more about the EtherStax Series and view all models >
ES2113: Ethernet Discrete I/O Modules Features & Benefits
- 96 discrete I/O channels: Bi-directional channels support any input/output mix in a single unit.
- High-density stackable unit: Stacked mounting puts a lot of I/O in a very small footprint to save panel space.
- High speed channel updates: Updates all 96 channels in 1mS.
- Modbus TCP/IP or UDP/IP protocol: I/O functions as slave to host controller.
- Peer-to-peer i2o communication: Inputs to one unit automatically update outputs on another over Ethernet link.
- Change-of-state or timed updates: Event-driven updates transmit data in less than 5mS between peers with i2o.
- 10 Modbus TCP/IP sockets/sessions: Multiple masters can talk to an EtherStax unit at the same time.
- Self-test checks I/O operation: Test I/O channels from a web browser before wiring terminals to devices.
- Selectable input “wetting” current: Internal current source eliminates pull-ups and improves dry contact interface.
- Automatic change of state detection: Inputs detect quick momentary changes of state that occur between polling.
- Internal or external port excitation: Selectable source on each 16-channel port simplifies wiring and adds flexibility for use with 5-28V DC logic.
- Loop-back monitoring on all channels: Inputs confirm output states for increased system reliability.
- Watchdog timers and failsafe outputs: Communication fault sends output to a pre-defined state or holds the last value.
- Output open-load detection: Output fault detection is selectable on individual channels.
- Thermal, current, voltage protection: I/O is protected from excessive levels to reduce downtime.
Specs & Catalogs
Manuals
ES2113 User Manual (Log in to download the file)
-
4001 Serial Cables
5-foot ribbon cable, DB25 male and 26-pin female IDC connectors, for 3B/5B backpanel to Ethernet I/O module connection -
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
-
5035 Series: Ethernet Cables
- Ethernet straight cable, CAT5
- Ethernet crossover cable, CAT5E
- Low EMI Double-Shielded Ethernet Patch Cable
-
900EN: 5-Port Ethernet Switch
- 10/100Mbps
- 15 to 36V DC power supply required
- Five shielded RJ-45 sockets, 8-pin, 10Base-T / 100Base-TX
-
AMTN, AMTX: ActiveX / .NET Controls for Modbus I/O
- Modbus/TCP or Modbus/RTU
- These ActiveX / .NET software controls provide a fast, easy way to communicate with any Modbus slave devices connected to your PC.
- Get your Visual Basic, Visual C, .NET, Excel, or other compatible applications talking Modbus protocol within minutes.
-
ESW-MBLIB: Ethernet Modbus C Library Software
- Universal support for five operating systems
- C source code provided
- Demo program included
-
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
-
Terminal Block Replacements
- Simplifies wiring connections on Acromag I/O Modules
- Barrier strip or spring clamp terminal block kits
- Provide safe and secure wiring connections
-
USB-to-Ethernet Adapter
Simplifies configuration of Acromag Ethernet I/O Modules Prevents disruption of existing LANs This device is a USB-to-Ethernet adapter that you can use to communicate with any Acromag Ethernet I/O product for the purpose of setup and re-configuration for your application. It is recommended for initial communication with Acromag Ethernet devices so that you do not have to disrupt your existing network connection.
Additional information
Weight | 80 oz |
---|---|
Dimensions | 9 × 2.5 × 7.25 in |
Part Number | ES2113-0000: two copper ports, IP40 enclosure, ES2113-1000: one Cu & one fiber port, IP40 enclosure, ES2113-1010: one Cu & one fiber port, open circuit board, ES2113-0010: two copper ports, open circuit board |
Communication | i2o Peer-to-Peer, Modbus TCP/IP, Modbus UDP/IP |
Product Series | EtherStax Series |
-
Description
ES2113: Ethernet Discrete I/O Modules
EtherStax I/O blocks provide a ruggedized, high-density solution to interface a very large quantity of discrete I/O signals to your control system. A stackable aluminum housing maintains a small footprint and stands up to harsh, industrial environments. Web-based configuration simplifies setup with any web browser.
Learn more about the EtherStax Series and view all models >
ES2113: Ethernet Discrete I/O Modules Features & Benefits
- 96 discrete I/O channels: Bi-directional channels support any input/output mix in a single unit.
- High-density stackable unit: Stacked mounting puts a lot of I/O in a very small footprint to save panel space.
- High speed channel updates: Updates all 96 channels in 1mS.
- Modbus TCP/IP or UDP/IP protocol: I/O functions as slave to host controller.
- Peer-to-peer i2o communication: Inputs to one unit automatically update outputs on another over Ethernet link.
- Change-of-state or timed updates: Event-driven updates transmit data in less than 5mS between peers with i2o.
- 10 Modbus TCP/IP sockets/sessions: Multiple masters can talk to an EtherStax unit at the same time.
- Self-test checks I/O operation: Test I/O channels from a web browser before wiring terminals to devices.
- Selectable input “wetting” current: Internal current source eliminates pull-ups and improves dry contact interface.
- Automatic change of state detection: Inputs detect quick momentary changes of state that occur between polling.
- Internal or external port excitation: Selectable source on each 16-channel port simplifies wiring and adds flexibility for use with 5-28V DC logic.
- Loop-back monitoring on all channels: Inputs confirm output states for increased system reliability.
- Watchdog timers and failsafe outputs: Communication fault sends output to a pre-defined state or holds the last value.
- Output open-load detection: Output fault detection is selectable on individual channels.
- Thermal, current, voltage protection: I/O is protected from excessive levels to reduce downtime.
-
Tech Papers
How to Remotely Control AC Power for a WEB Server with Ethernet Digital I/O - 8400642Steps to Remotely Control AC Power for a WEB Server, Using Acromag’s ES2113 or 989EN-4C16 Ethernet Digital I/O Modules Objective This document outlines the steps taken to use an ES2113 or 989EN DIO to control a latching relay that is used to open or close the AC power (115 VAC) path used by a multi...How to Communicate with Modbus/TCP Modules from Ignition Software - 8501121Setting Up and Communicating with Acromag Series 9xxEN-40xx and XTxxx1-xxx Modbus/TCP Modules and EtherStax™ Modbus/TCP from Ignition Software This document illustrates a procedure for configuring OPC tags intended for Acromag BusWorks® Series Modbus/TCP modules using Windows software from Inductive Automation. It is assumed that the user has a working knowledge of OPC, Modbus TCP, and...How to Configure an Acromag Modbus OPC Server - 8500882Configuring the Acromag Modbus OPC Server This document illustrates two different procedures for configuring the Acromag Modbus OPC Server to use with any OPC Client application. Configuration using CSV Files Start the Acromag Modbus OPC Server by selecting Start-> All Programs-> Acromag OPC-> Modbus TCP Master OPC DA Server-> OPC Server. Acromag has created and...How to Configure LabVIEW to Communicate with Modbus I/O Modules Via an OPC Server - 8500881Configuring LabVIEW 2009 to Communicate with Acromag BusWorks and EtherStax Modbus I/O Modules via an OPC Server Introduction National Instruments™ LabVIEW can be used to monitor and control Acromag BusWorks ® and EtherStax ® Modbus I/O modules via an OPC server. A separate application note, Configuring Kepware KEPServerEX® 5.0 for communications with Acromag BusWorks and EtherStax... -
Specs & Data Sheets
Specs & Catalogs
Manuals
ES2113 User Manual (Log in to download the file)
-
Software
-
Accessories
-
4001 Serial Cables
5-foot ribbon cable, DB25 male and 26-pin female IDC connectors, for 3B/5B backpanel to Ethernet I/O module connection -
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
-
5035 Series: Ethernet Cables
- Ethernet straight cable, CAT5
- Ethernet crossover cable, CAT5E
- Low EMI Double-Shielded Ethernet Patch Cable
-
900EN: 5-Port Ethernet Switch
- 10/100Mbps
- 15 to 36V DC power supply required
- Five shielded RJ-45 sockets, 8-pin, 10Base-T / 100Base-TX
-
AMTN, AMTX: ActiveX / .NET Controls for Modbus I/O
- Modbus/TCP or Modbus/RTU
- These ActiveX / .NET software controls provide a fast, easy way to communicate with any Modbus slave devices connected to your PC.
- Get your Visual Basic, Visual C, .NET, Excel, or other compatible applications talking Modbus protocol within minutes.
-
ESW-MBLIB: Ethernet Modbus C Library Software
- Universal support for five operating systems
- C source code provided
- Demo program included
-
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
-
Terminal Block Replacements
- Simplifies wiring connections on Acromag I/O Modules
- Barrier strip or spring clamp terminal block kits
- Provide safe and secure wiring connections
-
USB-to-Ethernet Adapter
Simplifies configuration of Acromag Ethernet I/O Modules Prevents disruption of existing LANs This device is a USB-to-Ethernet adapter that you can use to communicate with any Acromag Ethernet I/O product for the purpose of setup and re-configuration for your application. It is recommended for initial communication with Acromag Ethernet devices so that you do not have to disrupt your existing network connection.
-
Additional information
Additional information
Weight 80 oz Dimensions 9 × 2.5 × 7.25 in Part Number ES2113-0000: two copper ports, IP40 enclosure, ES2113-1000: one Cu & one fiber port, IP40 enclosure, ES2113-1010: one Cu & one fiber port, open circuit board, ES2113-0010: two copper ports, open circuit board
Communication i2o Peer-to-Peer, Modbus TCP/IP, Modbus UDP/IP
Product Series EtherStax Series
Please login to submit this form.