981EN, 982EN, 983EN: Ethernet Discrete I/O Modules
Please sign in or register to see model options and to add products to your cart.
Product short description:
- 12-channel discrete input and/or output
- Ethernet/IP, Modbus TCP/IP
- i2o peer-to-peer available for Modbus TCP/IP
These modules provide an isolated Ethernet network interface for twelve discrete input and/or output channels. The outputs provide direct on/off, high/low, or open/close control of industrial devices. The inputs sense the status of motors, pumps, valves and other equipment. The 983EN model with tandem I/O provides output level control and status verification in one unit.
981EN, 982EN, 983EN: Ethernet Discrete I/O Modules Description
981EN: 12 input channels
982EN: 12 output channels
983EN: 12 input/output channels
These modules provide an isolated Ethernet network interface for twelve discrete input and/or output channels. The outputs provide direct on/off, high/low, or open/close control of industrial devices.
The inputs sense the status of motors, pumps, valves and other equipment. The 983EN model with tandem I/O provides output level control and status verification in one unit.
Input Range: 0 to 35V DC.
Output Range: 0 to 35V DC.
Network Communication
EtherNet/IP, Modbus TCP/IP, (i2o® peer-to-peer available for Modbus TCP/IP only) 10/100Mbps with automatic data rate negotiation. Read more about i2o here.
Power Requirement: 15 to 36V DC supply (2 Watts) required.
Approvals
CE/ATEX marked.
UL, cUL listed, Class I; Div. 2; Groups A, B, C, D.
EtherNet/IP, Modbus/TCP conformance tested.
Learn more about the 900EN Series and view all models >
981EN, 982EN, 983EN: Ethernet Discrete I/O Modules Features & Benefits
- Configurable from standard web browser
- 12-channel stand-alone module has far lower start-up cost than multi-piece block I/O systems
- 0-35V DC solid-state logic interface can monitor or control a wide variety of devices
- Bidirectional I/O models facilitate loopback monitoring of the output state
- Socketed SIP resistors provide input and output 5.6K ohm pull-ups to the excitation supply
- Three selectable failsafe modes (off, last-state, or pre-defined) help prevent unsafe conditions
Specifications
Manuals
-
5035 Series: Ethernet Cables
- Ethernet straight cable, CAT5
- Ethernet crossover cable, CAT5E
- Low EMI Double-Shielded Ethernet Patch Cable
Additional information
Weight | 10 oz |
---|---|
Dimensions | 4.5 × 1.5 × 5 in |
Product Number | 981EN-6012: Ethernet/IP; 12 input channels, 982EN-6012: Ethernet/IP; 12 output channels, 983EN-6012: Ethernet/IP; 12 input/output channels, 981EN-4012: Modbus TCP/IP; 12 input channels, 982EN-4012: Modbus TCP/IP; 12 output channels, i2o capability, 983EN-4012: Modbus TCP/IP; 12 input/output channels, i2o capability |
Communication | Ethernet/IP, i2o Peer-to-Peer, Modbus TCP/IP |
Configuration | Built-in Web pages |
Product Series | BusWorks 900EN Series |
Power Type | DC Power |
-
Description
981EN, 982EN, 983EN: Ethernet Discrete I/O Modules Description
981EN: 12 input channels
982EN: 12 output channels
983EN: 12 input/output channelsThese modules provide an isolated Ethernet network interface for twelve discrete input and/or output channels. The outputs provide direct on/off, high/low, or open/close control of industrial devices.
The inputs sense the status of motors, pumps, valves and other equipment. The 983EN model with tandem I/O provides output level control and status verification in one unit.
Input Range: 0 to 35V DC.
Output Range: 0 to 35V DC.
Network Communication
EtherNet/IP, Modbus TCP/IP, (i2o® peer-to-peer available for Modbus TCP/IP only) 10/100Mbps with automatic data rate negotiation. Read more about i2o here.Power Requirement: 15 to 36V DC supply (2 Watts) required.
Approvals
CE/ATEX marked.
UL, cUL listed, Class I; Div. 2; Groups A, B, C, D.
EtherNet/IP, Modbus/TCP conformance tested.Learn more about the 900EN Series and view all models >
981EN, 982EN, 983EN: Ethernet Discrete I/O Modules Features & Benefits
- Configurable from standard web browser
- 12-channel stand-alone module has far lower start-up cost than multi-piece block I/O systems
- 0-35V DC solid-state logic interface can monitor or control a wide variety of devices
- Bidirectional I/O models facilitate loopback monitoring of the output state
- Socketed SIP resistors provide input and output 5.6K ohm pull-ups to the excitation supply
- Three selectable failsafe modes (off, last-state, or pre-defined) help prevent unsafe conditions
-
Tech Papers
How to Connect Ethernet I/O Modules with RadioLinx Ethernet Modems - 8500770Connecting Acromag Series 900EN I/O Modules to an existing network with RadioLinx Ethernet Modems Background – IP Addresses Any TCP/IP packet contains two addresses: a unique fixed MAC address, and a unique IP address. To communicate on the Internet, computers must have unique identifiers in order to differentiate one computer from another. This is accomplished...How to Communicate with Modbus/TCP Modules from Ignition Software - 8501121Setting Up and Communicating with Acromag Series 9xxEN-40xx and XTxxx1-xxx Modbus/TCP Modules and EtherStaxâ„¢ Modbus/TCP from Ignition Software This document illustrates a procedure for configuring OPC tags intended for Acromag BusWorks® Series Modbus/TCP modules using Windows software from Inductive Automation. It is assumed that the user has a working knowledge of OPC, Modbus TCP, and...How to Connect to Acromag Ethernet I/O Devices - 8500815Getting Connected to Acromag Ethernet I/O Devices These instructions summarize the basic steps you will have to take in order to initially connect an Acromag Ethernet I/O product to your Personal Computer (PC) or laptop. To connect an Ethernet device to your PC, consult with your network administrator. Either temporarily change the TCP/IP configuration of...How to Connect Acromag 900EN Ethernet Modules to Your PC - 8500734Connecting Acromag Series 900EN Ethernet Modules to Your PC Objective: The purpose of this document is to provide a procedure for assigning a unique IP address to a second network interface card installed in a personal computer for the purpose of communicating with an Acromag Series 9xxEN Ethernet I/O Module. A procedure for accomplishing IP address...How to Communicate with Acromag Ethernet/IP Modules from CompactLogix Controllers - 8500762Communicating with Acromag Series 9xxEN-60xx, XTxxx2-xxx, and NTE2xxx-xxxx Ethernet/IPâ„¢ Modules from CompactLogixâ„¢ PLC Device This document illustrates a procedure for configuring message commands intended for Acromag Busworks® Series Ethernet/IP modules using Ladder Logic programming software in addition to a CompactLogix Programmable Controller. It is assumed that the user has a working knowledge of; Ladder Logic...How to Communicate to Ethernet Modules in an Allen Bradley ControlLogix System - 8400495Communicating to Acromag BusWorks Series 9xxEN-6xxx and XTxxx2-xxx Ethernet Modules in an Allen Bradley ControlLogix System Objective: This document illustrates a procedure for integrating the Acromag Series XTxxx2, and 9xxEN-6xxx modules into the Allen Bradley control system as a third-party generic module. The reference model for this procedure is the Model 961EN-6006. It is assumed...How to Configure Kepware KEPServerEX 5.0 for Communications with Modbus I/O Modules - 8500880Configuring Kepware KEPServerEX 5.0 for Communications with Acromag BusWorks Modbus I/O Modules Introduction This document provides example steps for configuring the Kepware KEPServerEX OPC Server for communications with Acromag Busworks Modbus RTU and Modbus TCP/IP Distributed I/O Modules. Once the server is configured, data may be read from or written to the I/O module using...How to Configure LabVIEW to Communicate with Modbus I/O Modules Via an OPC Server - 8500881Configuring LabVIEW 2009 to Communicate with Acromag BusWorks and EtherStax Modbus I/O Modules via an OPC Server Introduction National Instrumentsâ„¢ LabVIEW can be used to monitor and control Acromag BusWorks ® and EtherStax ® Modbus I/O modules via an OPC server. A separate application note, Configuring Kepware KEPServerEX® 5.0 for communications with Acromag BusWorks and EtherStax...How to Configure Omron PLCs with Ethernet/IP for Use with Remote I/O - 8500883Configuring Omron CJ2H PLC’s with Ethernet/IP for use with Acromag Ethernet/IP Remote I/O Purpose: Acromag Ethernet/IP I/O with Omron CJ2H PLC’s This document walks the user through the configuration of the Cx-One Network Configurator software that is used in conjunction with Omron CJ2H PLC’s. It is assumed that the user has a working knowledge of...How to Communicate to Ethernet Modules using PCCC from CompactLogix Devices - 8500771Communicating to Acromag Series 900EN60xx Ethernet Modules Using PCCC from CompactLogix Devices PCCC Messaging with CompactLogix This document illustrates a procedure for configuring PCCC message commands for Acromag Series 900EN Ethernet/IP modules. We will be using Ladder Logic programming together with a CompactLogix Controller. It is assumed that the user has a working knowledge of...How to Communicate to Ethernet Modules from Legacy Allen Bradley or Rockwell Automation Devices - 8500761Communicating to Acromag Series 900EN-60xx Ethernet Modules from Legacy Allen Bradley or Rockwell Automation Devices This document illustrates a procedure for configuring message commands for Acromag Series 900EN Ethernet/IP modules, using Ladder Logic programming and an SLC5\05 Programmable Logic Controller. It is assumed that the user has a working knowledge of Ladder Logic programming, the...How to Configure a Wonderware I/O Server to Communicate with Ethernet Modules - 8500766How to Configure the Wonderware MBENET I/O Server to Communicate with the Acromag 900EN Series Ethernet Modules Wonderware MBENET The purpose of this document is to provide a procedure for configuring MBENET I/O Server (ie: Modicon Ethernet I/O Server) to communicate with an Acromag 900EN Series Ethernet I/O Module. It is assumed that the user... -
Specs & Data Sheets
Specifications
Manuals
-
Software
-
Accessories
-
5035 Series: Ethernet Cables
- Ethernet straight cable, CAT5
- Ethernet crossover cable, CAT5E
- Low EMI Double-Shielded Ethernet Patch Cable
-
-
Additional information
Additional information
Weight 10 oz Dimensions 4.5 × 1.5 × 5 in Product Number 981EN-6012: Ethernet/IP; 12 input channels, 982EN-6012: Ethernet/IP; 12 output channels, 983EN-6012: Ethernet/IP; 12 input/output channels, 981EN-4012: Modbus TCP/IP; 12 input channels, 982EN-4012: Modbus TCP/IP; 12 output channels, i2o capability, 983EN-4012: Modbus TCP/IP; 12 input/output channels, i2o capability
Communication Ethernet/IP, i2o Peer-to-Peer, Modbus TCP/IP
Configuration Built-in Web pages
Product Series BusWorks 900EN Series
Power Type DC Power
Please login to submit this form.