XT1240: 16-Channel Single-ended Analog DC Voltage Input Module
Please sign in or register to see model options and to add products to your cart.
Product short description:
- Input: ±5V, ±10V, 0-5V, 0-10V
- 16 analog single-ended voltage input channels
- 12 to 32V DC Power (2.8W)
- Modbus TCP/IP, Ethernet/IP, Profinet
- i2o® peer-to-peer available for Modbus TCP/IP only
The XT1240 offers an isolated Ethernet network interface for up to to sixteen single-ended voltage input channels.
XT1240: 16-Channel Single-ended Analog DC Voltage Input Module Description
The XT1240 offers an isolated Ethernet network interface for up to to sixteen single-ended voltage input channels.
Single-ended inputs enable a higher channel density to save space and a lower cost per channel.
Rugged construction, high density design, and easy USB-to-PC/Windows setup combine for a very effective and reliable module.
These units are ideal for remote monitoring, distributed control, or SCADA applications.
Input Ranges
DC Voltage: ±5V, ±10V, 0 to 5V, 0 to 10V.
Ethernet Communication
Modbus TCP/IP, i2o® peer-to-peer available for Modbus TCP/IP only.
Ethernet/IP
Profinet
10/100Base-T(X)
PriorityChannelâ„¢ device determinism
Power Requirement: 12 to 32V DC (2.8W).
IMPORTANT:Â To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends use of the USB-ISOLATOR when configuring an XT1000 I/O module.
Learn more about the Ethernet XT Series and view all models >
XT1240: 16-Channel Single-ended Analog DC Voltage Input Module Features & Benefits
- i2o® peer-to-peer available for Modbus TCP/IP only
- i2o® peer-to-peer updates based on change-of-state and/or timed updates
- Easy setup with Windows software via USB
- High input impendence (100K ohms) reduces loading on voltage loops
- User-configurable sample averaging (1-200) on a per-channel basis
- 10ms network updates for all 16 input channels
- High-resolution 16-bit Σ∆ A/D converter ensures precise, high accuracy measurements
- High-Density 22.5mm wide package with pluggable, front-facing terminals
- Dual Ethernet 10/100 ports (auto-negotiation) reduce switch port requirements
- 1500V AC isolation (between I/O, power, and network ports) and surge/transient protection
- Supports bussed/rail and redundant power
- -40°C to 70°C wide temperature operation
- Withstands 25g shock and 4g vibration
- CE compliant. UL/cUL Class 1 Div 2 Zone 2 approvals.
- ATEX Certified.
Specifications
Manuals
Brochure
-
An Isolator: USB Isolator
- USB-powered, USB 2.0 and 1.1 compatible
- 1500V AC / 2100V DC isolation
- No drivers required
-
XT-SIP: Software Interface Package
- Software Interface Package for BusWorks XT Series Ethernet I/O modules.
- Easy setup and digital calibration via USB with Windows configuration software
- Download software only from the Software Tab below
Additional information
Weight | 8 oz |
---|---|
Dimensions | 4.5 × 1.5 × 5 in |
Part Number | XT1241-000: Modbus TCP/IP and i2o protocol, XT1242-000: Ethernet/IP protocol, XT1243-000: Profinet protocol |
Communication | Ethernet/IP, i2o Peer-to-Peer, Modbus TCP/IP, Profinet |
Configuration | USB Configuration, Windows Software Configuration |
Product Series | BusWorks XT Series |
-
Description
XT1240: 16-Channel Single-ended Analog DC Voltage Input Module Description
The XT1240 offers an isolated Ethernet network interface for up to to sixteen single-ended voltage input channels.
Single-ended inputs enable a higher channel density to save space and a lower cost per channel.
Rugged construction, high density design, and easy USB-to-PC/Windows setup combine for a very effective and reliable module.
These units are ideal for remote monitoring, distributed control, or SCADA applications.
Input Ranges
DC Voltage: ±5V, ±10V, 0 to 5V, 0 to 10V.Ethernet Communication
Modbus TCP/IP, i2o® peer-to-peer available for Modbus TCP/IP only.
Ethernet/IP
Profinet
10/100Base-T(X)
PriorityChannelâ„¢ device determinismPower Requirement: 12 to 32V DC (2.8W).
IMPORTANT:Â To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends use of the USB-ISOLATOR when configuring an XT1000 I/O module.
Learn more about the Ethernet XT Series and view all models >
XT1240: 16-Channel Single-ended Analog DC Voltage Input Module Features & Benefits
- i2o® peer-to-peer available for Modbus TCP/IP only
- i2o® peer-to-peer updates based on change-of-state and/or timed updates
- Easy setup with Windows software via USB
- High input impendence (100K ohms) reduces loading on voltage loops
- User-configurable sample averaging (1-200) on a per-channel basis
- 10ms network updates for all 16 input channels
- High-resolution 16-bit Σ∆ A/D converter ensures precise, high accuracy measurements
- High-Density 22.5mm wide package with pluggable, front-facing terminals
- Dual Ethernet 10/100 ports (auto-negotiation) reduce switch port requirements
- 1500V AC isolation (between I/O, power, and network ports) and surge/transient protection
- Supports bussed/rail and redundant power
- -40°C to 70°C wide temperature operation
- Withstands 25g shock and 4g vibration
- CE compliant. UL/cUL Class 1 Div 2 Zone 2 approvals.
- ATEX Certified.
-
Tech Papers
How to Communicate with Acromag Ethernet/IP Modules from CompactLogix Controllers - 8500762Communicating with Acromag Series 9xxEN-60xx, XTxxx2-xxx, and NTE2xxx-xxxx Ethernet/IP™ Modules from CompactLogix™ PLC Device This document illustrates a procedure for configuring message commands intended for Acromag Busworks® Series Ethernet/IP modules using Ladder Logic programming software in addition to a CompactLogix Programmable Controller. It is assumed that the user has a working knowledge of; Ladder Logic...How to Connect to Acromag Ethernet I/O Devices - 8500815Getting Connected to Acromag Ethernet I/O Devices These instructions summarize the basic steps you will have to take in order to initially connect an Acromag Ethernet I/O product to your Personal Computer (PC) or laptop. To connect an Ethernet device to your PC, consult with your network administrator. Either temporarily change the TCP/IP configuration of...How to Communicate with Ethernet XT Profinet from Siemens S7-1200 PLC - 8501007Communicating with Acromag Model XTxxx3-000 Profinet I/O Modules from a Siemens S7-1200 PLC EthernetXT Profinet and Siemens S7-1200 When setting up a Profinet network, Profinet controllers are programmed with a special Profinet Configuration tool, like the Step7 from Siemens. This document illustrates an example procedure for configuring communications between Acromag BusWorks® Series Profinet modules and...How to Communicate to Ethernet Modules from Red Lion HMIs - 8500874How to Communicate to Acromag Ethernet Modules from Red Lion HMIs Red Lion HMIs This document illustrates a procedure for configuring message commands for Acromag Ethernet modules using the Red Lion Crimson 2.0 software. It is assumed that the user has a working knowledge of the Crimson 2.0 software, as well as a Red Lion...How to Communicate to Ethernet Modules in an Allen Bradley ControlLogix System - 8400495Communicating to Acromag BusWorks Series NT2000, 9xxEN-6xxx and XTxxx2-xxx Ethernet Modules with an Allen Bradley ControlLogix System Objective: This document illustrates a procedure for integrating the Acromag Series XTxxx2, and 9xxEN-6xxx modules into the Allen Bradley control system as a third-party generic module. The reference model for this procedure is the Model 961EN-6006. It is... -
Specs & Data Sheets
Specifications
Manuals
Brochure
-
Software
XT-SIP: Software Interface Information Page (Log in to download the file)ESW-MBLIB: Ethernet Modbus C Library Software Information Page (Log in to download the file)Ethernet XT Series Configuration Software (Log in to download the file)AMTx: Modbus TCP/IP Software Information Page (Log in to download the file)Profinet GSDML Files for XTxxx3-000 Modules (Log in to download the file)Ethernet IP EDS For XTxxx2-000 Modules (Log in to download the file) -
Accessories
-
An Isolator: USB Isolator
- USB-powered, USB 2.0 and 1.1 compatible
- 1500V AC / 2100V DC isolation
- No drivers required
-
XT-SIP: Software Interface Package
- Software Interface Package for BusWorks XT Series Ethernet I/O modules.
- Easy setup and digital calibration via USB with Windows configuration software
- Download software only from the Software Tab below
-
-
Additional information
Additional information
Weight 8 oz Dimensions 4.5 × 1.5 × 5 in Part Number XT1241-000: Modbus TCP/IP and i2o protocol, XT1242-000: Ethernet/IP protocol, XT1243-000: Profinet protocol
Communication Ethernet/IP, i2o Peer-to-Peer, Modbus TCP/IP, Profinet
Configuration USB Configuration, Windows Software Configuration
Product Series BusWorks XT Series
Please login to submit this form.