XT1230: 16-Channel Single-Ended Analog Current Input Module
Please sign in or register to see model options and to add products to your cart.
Product short description:
- 0-11mA, 0-20mA, 4-20mA, ±20mA, or 0-20 amps AC Input
- 16 analog single-ended current input channels
- 12 to 32V DC Power (2.8W)
- Modbus TCP/IP, Ethernet/IP, Profinet
- i2o® peer-to-peer available for Modbus TCP/IP only
The XT1230 offers an isolated Ethernet network interface for up to to sixteen single-ended current input channels.
- Description
- Features & Benefits
- Tech Papers
- Specs & Data Sheets
- Software
- Accessories
- Additional information
XT1230: 16-Channel Single-Ended Analog Current Input Module Description
The XT1230 offers an isolated Ethernet network interface for up to to sixteen single-ended current input channels.
Single-ended inputs enable a higher channel density to save space and a lower cost per channel.
Rugged construction, high density design, and easy USB-to-PC/Windows setup combine for a very effective and reliable module.
These units are ideal for remote monitoring, distributed control, or SCADA applications.
Input Ranges
DC Current:
0 to 11mA, 0 to 20mA, 4 to 20mA, ±20mA.
0 to 20 amps AC (with optional AC sensor).
Ethernet Communication
Modbus TCP/IP, i2o® peer-to-peer available for Modbus TCP/IP only.
Ethernet/IP
Profinet
10/100Base-T(X)
PriorityChannel™ device determinism
Power Requirement: 12 to 32V DC (2.8W).
Learn more about the Ethernet XT Series and view all models >
XT1230: 16-Channel Single-Ended Analog Current Input Module Performance Specifications
IMPORTANT: To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends use of the USB-ISOLATOR when configuring an XT1000 I/O module.
USB Interface
USB Connector
Type: USB Mini-B type socket, 5-pin.
Data Rate: 12Mbps. USB v1.1 and 2.0 compatible.
Cable Length: 5.0 meters maximum.
USB Transient Protection: Transient voltage suppression on power and data lines.
Driver: Not required. Uses Windows (HID) drivers.
Input
Accuracy: ±0.05% of span, typical for nominal input ranges.
Analog to Digital Converter (A/D): 16-bit Σ-Δ converter. 1.476uA/bit resolution.
Noise Rejection: Better than -110dB @ 60Hz.
Input Filter Bandwidth: -3dB at 25KHz, typical.
Input Conversion Rate: 10ms for all 16 input channels.
Input Impedance: 27.4 ohms.
Ethernet Communication
Protocols
Modbus TCP/IP, i2o® peer-to-peer available for Modbus TCP/IP only
Ethernet/IP or Profinet, depending on model number.
Ethernet Communication Controller: Innovasic RapID™ Platform with PriorityChannel™ for determinism at the device regardless of network load.
Modbus TCP/IP (slave): Port 502 reserved. Supports up to 10 sockets.
i2o Peer-to-Peer (master/slave): Can map each of 16 analog input channels separately to output channels. Timed (1-65535 sec) or percent of change updates. Supports GPRS/GSM systems.
Ethernet/IP (adapter): Supports 10 connections. EDS file on website.
Profinet (server): Supports 1 connection. GSDML file on website.
Connectors: Two shielded 8-pin RJ-45 sockets, 10BaseT/100BaseTX.
Wiring: Auto-crossover for MDI or MDI-X.
IP Address: User-configurable. 192.168.1.100 default IP address.
Data Rate: Auto-negotiated, 10Mbps or 100Mbps.
Compliance: IEEE 802.3, 802.3u, 802.3x.
Environmental
Operating temperature: -40 to 70°C (-40 to 158°F).
Storage temperature: -40 to 85°C (-40 to 185°F).
Relative humidity: 5 to 95% non-condensing.
MTBF:
463,547 hrs. at 25°C.
345,200 hrs. at 40°C.
Power Requirement: 12 to 32V DC, 2.8W maximum (113mA maximum @ 24V).
Isolation
4-way isolation between I/O channels, network (each port), and power.
Peak: 1500V AC, ANSI/ISA-82.01-1988.
Continuous: 250V AC, 354V DC.
Shock and Vibration Immunity
Vibration: 4g, per IEC 60068-2-64.
Shock: 25g, per IEC 60068-2-27.
Electromagnetic Compatibility (EMC) Compliance
Radiated Emissions: BS EN 61000-6-4, CISPR 16.
RFI: BS EN 61000-6-2, IEC 61000-4-3.
Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6.
ESD: BS EN 61000-6-2, IEC 61000-4-2.
EFT: BS EN 61000-6-2, IEC 61000-4-4.
Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5.
Approvals
CE compliant. UL/cUL Class I; Div. 2 Zone 2. ATEX Certified.
Physical
General: General purpose plastic enclosure for mounting on 35mm “T-type” DIN rail.
Case Material: Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General purpose NEMA Type 1 enclosure.
Circuit Board: Military grade fire-retardant epoxy glass (IPC-4101/98).
I/O Connectors: Removable plug-in type terminal blocks rated for 12A/250V; AWG #26-12, stranded/solid copper wire.
Dimensions:
Width = 22.5mm (0.9 inches).
Length = 114.5mm (4.51 inches).
Depth = 99.0mm (3.90 inches).
Shipping Weight: 0.5 pounds (0.22 Kg) packed.
Learn more about the Ethernet XT Series and view all models >
- i2o® peer-to-peer available for Modbus TCP/IP only
- i2o® peer-to-peer updates based on change-of-state and/or timed updates
- Easy setup with Windows software via USB
- Low input impendance (27 ohms) reduces loading on current loops
- User-configurable sample averaging (1-200) on a per-channel basis
- 10ms network updates for all 16 input channels
- High-resolution 16-bit Σ∆ A/D converter ensures precise, high accuracy measurements
- High-Density 22.5mm wide package with pluggable, front-facing terminals
- Dual Ethernet 10/100 ports (auto-negotiation) reduce switch port requirements
- 1500V AC isolation (between I/O, power, and network ports) and surge/transient protection
- Supports bussed/rail and redundant power
- -40°C to 70°C wide temperature operation
- Withstands 25g shock and 4g vibration
- CE compliant
- UL/cUL Class 1 Div 2 Zone 2 approvals
- ATEX Certified
Specifications
Manuals
Brochure
-
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
-
5035 Series: Ethernet Cables
- Ethernet straight cable, CAT5
- Ethernet crossover cable, CAT5E
- Low EMI Double-Shielded Ethernet Patch Cable
-
XT-SIP: Software Interface Package
- Software Interface Package for BusWorks XT Series Ethernet I/O modules.
- Easy setup and digital calibration via USB with Windows configuration software
- Download software only from the Software Tab below
Additional information
Weight | 8 oz |
---|---|
Dimensions | 4.5 × 1.5 × 5 in |
Part Number | XT1231-000: Modbus TCP/IP and i2o protocol, XT1232-000: Ethernet/IP protocol, XT1233-000: Profinet protocol |
Communication | Ethernet/IP, i2o Peer-to-Peer, Modbus TCP/IP, Profinet |
Product Series | BusWorks XT Series |
Configuration | USB Configuration, Windows Software Configuration |
-
Description
XT1230: 16-Channel Single-Ended Analog Current Input Module Description
The XT1230 offers an isolated Ethernet network interface for up to to sixteen single-ended current input channels.
Single-ended inputs enable a higher channel density to save space and a lower cost per channel.
Rugged construction, high density design, and easy USB-to-PC/Windows setup combine for a very effective and reliable module.
These units are ideal for remote monitoring, distributed control, or SCADA applications.
Input Ranges
DC Current:
0 to 11mA, 0 to 20mA, 4 to 20mA, ±20mA.
0 to 20 amps AC (with optional AC sensor).Ethernet Communication
Modbus TCP/IP, i2o® peer-to-peer available for Modbus TCP/IP only.
Ethernet/IP
Profinet
10/100Base-T(X)
PriorityChannel™ device determinismPower Requirement: 12 to 32V DC (2.8W).
Learn more about the Ethernet XT Series and view all models >
XT1230: 16-Channel Single-Ended Analog Current Input Module Performance Specifications
IMPORTANT: To prevent damage or errors from grounded PCs and surges, Acromag strongly recommends use of the USB-ISOLATOR when configuring an XT1000 I/O module.
USB Interface
USB Connector
Type: USB Mini-B type socket, 5-pin.
Data Rate: 12Mbps. USB v1.1 and 2.0 compatible.
Cable Length: 5.0 meters maximum.
USB Transient Protection: Transient voltage suppression on power and data lines.
Driver: Not required. Uses Windows (HID) drivers.
Input
Accuracy: ±0.05% of span, typical for nominal input ranges.
Analog to Digital Converter (A/D): 16-bit Σ-Δ converter. 1.476uA/bit resolution.
Noise Rejection: Better than -110dB @ 60Hz.
Input Filter Bandwidth: -3dB at 25KHz, typical.
Input Conversion Rate: 10ms for all 16 input channels.
Input Impedance: 27.4 ohms.
Ethernet Communication
Protocols
Modbus TCP/IP, i2o® peer-to-peer available for Modbus TCP/IP only
Ethernet/IP or Profinet, depending on model number.Ethernet Communication Controller: Innovasic RapID™ Platform with PriorityChannel™ for determinism at the device regardless of network load.
Modbus TCP/IP (slave): Port 502 reserved. Supports up to 10 sockets.
i2o Peer-to-Peer (master/slave): Can map each of 16 analog input channels separately to output channels. Timed (1-65535 sec) or percent of change updates. Supports GPRS/GSM systems.
Ethernet/IP (adapter): Supports 10 connections. EDS file on website.
Profinet (server): Supports 1 connection. GSDML file on website.
Connectors: Two shielded 8-pin RJ-45 sockets, 10BaseT/100BaseTX.
Wiring: Auto-crossover for MDI or MDI-X.
IP Address: User-configurable. 192.168.1.100 default IP address.
Data Rate: Auto-negotiated, 10Mbps or 100Mbps.
Compliance: IEEE 802.3, 802.3u, 802.3x.
Environmental
Operating temperature: -40 to 70°C (-40 to 158°F).
Storage temperature: -40 to 85°C (-40 to 185°F).
Relative humidity: 5 to 95% non-condensing.
MTBF:
463,547 hrs. at 25°C.
345,200 hrs. at 40°C.Power Requirement: 12 to 32V DC, 2.8W maximum (113mA maximum @ 24V).
Isolation
4-way isolation between I/O channels, network (each port), and power.
Peak: 1500V AC, ANSI/ISA-82.01-1988.
Continuous: 250V AC, 354V DC.Shock and Vibration Immunity
Vibration: 4g, per IEC 60068-2-64.
Shock: 25g, per IEC 60068-2-27.Electromagnetic Compatibility (EMC) Compliance
Radiated Emissions: BS EN 61000-6-4, CISPR 16.
RFI: BS EN 61000-6-2, IEC 61000-4-3.
Conducted RFI: BS EN 61000-6-2, IEC 61000-4-6.
ESD: BS EN 61000-6-2, IEC 61000-4-2.
EFT: BS EN 61000-6-2, IEC 61000-4-4.
Surge Immunity: BS EN 61000-6-2, IEC 61000-4-5.Approvals
CE compliant. UL/cUL Class I; Div. 2 Zone 2. ATEX Certified.Physical
General: General purpose plastic enclosure for mounting on 35mm “T-type” DIN rail.
Case Material: Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General purpose NEMA Type 1 enclosure.
Circuit Board: Military grade fire-retardant epoxy glass (IPC-4101/98).
I/O Connectors: Removable plug-in type terminal blocks rated for 12A/250V; AWG #26-12, stranded/solid copper wire.
Dimensions:
Width = 22.5mm (0.9 inches).
Length = 114.5mm (4.51 inches).
Depth = 99.0mm (3.90 inches).Shipping Weight: 0.5 pounds (0.22 Kg) packed.
Learn more about the Ethernet XT Series and view all models >
-
Features & Benefits
- i2o® peer-to-peer available for Modbus TCP/IP only
- i2o® peer-to-peer updates based on change-of-state and/or timed updates
- Easy setup with Windows software via USB
- Low input impendance (27 ohms) reduces loading on current loops
- User-configurable sample averaging (1-200) on a per-channel basis
- 10ms network updates for all 16 input channels
- High-resolution 16-bit Σ∆ A/D converter ensures precise, high accuracy measurements
- High-Density 22.5mm wide package with pluggable, front-facing terminals
- Dual Ethernet 10/100 ports (auto-negotiation) reduce switch port requirements
- 1500V AC isolation (between I/O, power, and network ports) and surge/transient protection
- Supports bussed/rail and redundant power
- -40°C to 70°C wide temperature operation
- Withstands 25g shock and 4g vibration
- CE compliant
- UL/cUL Class 1 Div 2 Zone 2 approvals
- ATEX Certified
-
Tech Papers
How to Communicate with Acromag Ethernet/IP Modules from CompactLogix Controllers - 8500762Communicating with Acromag Series 9xxEN-60xx, XTxxx2-xxx, and NTE2xxx-xxxx Ethernet/IP™ Modules from CompactLogix™ PLC Device This document illustrates a procedure for configuring message commands intended for Acromag Busworks® Series Ethernet/IP modules using Ladder Logic programming software in addition to a CompactLogix Programmable Controller. It is assumed that the user has a working knowledge of; Ladder Logic...How to Connect to Acromag Ethernet I/O Devices - 8500815Getting Connected to Acromag Ethernet I/O Devices These instructions summarize the basic steps you will have to take in order to initially connect an Acromag Ethernet I/O product to your Personal Computer (PC) or laptop. To connect an Ethernet device to your PC, consult with your network administrator. Either temporarily change the TCP/IP configuration of...How to Communicate with Ethernet XT Profinet from Siemens S7-1200 PLC - 8501007Communicating with Acromag Model XTxxx3-000 Profinet I/O Modules from a Siemens S7-1200 PLC EthernetXT Profinet and Siemens S7-1200 When setting up a Profinet network, Profinet controllers are programmed with a special Profinet Configuration tool, like the Step7 from Siemens. This document illustrates an example procedure for configuring communications between Acromag BusWorks® Series Profinet modules and...How to Communicate to Ethernet Modules from Red Lion HMIs - 8500874How to Communicate to Acromag Ethernet Modules from Red Lion HMIs Red Lion HMIs This document illustrates a procedure for configuring message commands for Acromag Ethernet modules using the Red Lion Crimson 2.0 software. It is assumed that the user has a working knowledge of the Crimson 2.0 software, as well as a Red Lion... -
Specs & Data Sheets
Specifications
Manuals
Brochure
-
Software
XT-SIP: Software Interface Information Page (Log in to download the file)ESW-MBLIB: Ethernet Modbus C Library Software Information Page (Log in to download the file)Ethernet XT Series Configuration Software (Log in to download the file)AMTx: Modbus TCP/IP Software Information Page (Log in to download the file)Profinet GSDML Files for XTxxx3-000 Modules (Log in to download the file)Ethernet IP EDS For XTxxx2-000 Modules (Log in to download the file) -
Accessories
-
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
-
5035 Series: Ethernet Cables
- Ethernet straight cable, CAT5
- Ethernet crossover cable, CAT5E
- Low EMI Double-Shielded Ethernet Patch Cable
-
XT-SIP: Software Interface Package
- Software Interface Package for BusWorks XT Series Ethernet I/O modules.
- Easy setup and digital calibration via USB with Windows configuration software
- Download software only from the Software Tab below
-
-
Additional information
Additional information
Weight 8 oz Dimensions 4.5 × 1.5 × 5 in Part Number XT1231-000: Modbus TCP/IP and i2o protocol, XT1232-000: Ethernet/IP protocol, XT1233-000: Profinet protocol
Communication Ethernet/IP, i2o Peer-to-Peer, Modbus TCP/IP, Profinet
Product Series BusWorks XT Series
Configuration USB Configuration, Windows Software Configuration
Please login to submit this form.