Click to zoom

Please sign in or register to see model options and to add products to your cart.

Product short description:
  • 32 analog inputs (16 current + 16 voltages)
  • Modbus TCP/IP, UDP/IP, i2o® peer-to-peer communication

These EtherStax I/O units provide a rugged, high-density, and high-speed solution to interface a large quantity of analog input signals. Units accept 16 single-ended analog voltage inputs and 16 single-ended current inputs. A DB25 port supports an alternate interface of voltage inputs from microBlox® uB signal conditioning modules.

 

ES2153: Ethernet Analog Input Modules Description

These EtherStax® I/O units provide a rugged, high-density, and high-speed solution to interface a large quantity of analog input signals. Units accept 16 single-ended analog voltage inputs and 16 single-ended current inputs.

A DB25 port supports an alternate interface of voltage inputs from microBlox® uB signal conditioning modules. This combination of high-density analog current and voltage inputs is ideal for many sensor interface applications in remote zones.

EtherStax units are built and tested for high reliability and dependable performance in hostile environments. Available in an aluminum enclosure or as an open circuit board, both formats stack vertically to maintain a very small footprint.

Performance Specifications

Analog Field Inputs

Input Channel Configuration: 16 single-ended analog voltage inputs and 16 single-ended analog current inputs.

Input Ranges (select on per-channel basis): ±5V, ±10V, ±20mA, 0-20mA, or 4-20mA DC.

Input Scaling (per-channel basis): Floating Point Format: IEEE-754.

Input Resolution: 16-bit maximum, 0.00166% (1 part in 60,000).

Input Accuracy:
Current Input: Better than 0.1% of range.
Voltage Input: Better than 0.05% of range.

Input Impedance: Voltage: 4M ohms minimum.

Current: 100 ohms.

Input Scan Groups and Scan Times:
Eight user-enabled 4-channel scan groups.
770µS update/group (5mS for all 32 channels) with averaging, loopback, and totalization functions disabled.

Input Overvoltage Protection: Bipolar Transient Voltage Suppressers (TVS), 18V clamp level typical.

Noise Rejection: CMR (50-60Hz): Better than -72dB.

Sample Averaging (user-configurable): 0-500 samples. One register for all channels.

Local Alarm Output

Configuration: Failsafe or non-failsafe (user-configurable) relay trips on power or link-loss failure.

Type: SPST-NO, 1 Form A, Class I, Division II approved.

Rating:
3A @ 24V DC/250V AC, 100,000 cycles general.
2A @ 24V DC/250V AC, Hazardous locations.

Maximum Switching Voltage and Power: 250V AC / 750VA, 125V DC / 90W.

Ethernet Interface

Internal Switch or Hub/Repeater: Dual-port Ethernet switch. User-configurable as a true switch (default mode) or low-latency hub.

Network Connector [10/100 Base-T(X)Copper]: One or two 8-pin RJ-45 connectors. Automatic MDI/MDI-X. 100m communication distance.

Network Connector (100 Base-FX Fiber-optic): One multi-mode with SC connector. 2km communication distance. Full/half-duplex, selectable.

Protocols: Modbus TCP/IP, UDP/IP, i2o peer-to-peer.

Addressing: StaticIP, DHCP, BootP.

Ethernet Modbus TCP/IP Sockets/Sessions: 1-10 socket/sessions user-configurable.

Ethernet Redundancy: Compatible with STP, RSTP, or any ring scheme.

i2o® Peer-to-Peer Communication

Each port of 8 input channels can be mapped to output ports of two ES215x units. Updates based on time (100mS resolution) or percent of range change (0.1% resolution).

Environmental

Operating and Storage Temperature:
Operating: -40 to 70°C (-40 to 158°F).
Storage: -40 to 85°C (-40 to 185°F).

Power Requirements:
18-36V DC. Redundant, diode-coupled terminals.
4.8W (copper ports), 5.8W (fiber-optic ports).

Isolation: I/O, power, relay and Ethernet port-to-port.

Peak: 1500V AC, ANSI/ISA-82.01-1988.

Continuous: 250V AC, 354V DC (150V AC ch-ch).

Enclosure and Physical

Housing Classification and Dimensions:
IP20:  8.226 x 2.444 x 7.25”, 4 lbs. packed.
PCB:  7.920 x 1.875 x 7.25”, 1.65 lbs. packed.

Safety Approvals: UL/cUL Listed.

Hazardous Locations: Class I; Div 2; A, B, C, D.Open board units: UL Recognized.

Shock and Vibration Immunity (in enclosure):
Mechanical Shock: 50g (3ms), 30g (11ms)
Random Vibration: 5g, (5-500Hz)

 

  • 32-channel high-density combination of analog current and voltage inputs
  • DB25 port for alternate voltage inputs from microBlox uB signal conditioning backpanels
  • 3-way isolation and surge suppression
  • High-resolution 16-bit A/D
  • High-speed scanning for 10 millisecond update of all 32 channels
  • Automatic zero/span calibration
  • On-demand self-test verifies calibration
  • Web browser configuration
  • User-configurable sample averaging and integration/totalization function with non-volatile registers
  • Dual-format data registers support 16-bit integers or 32-bit floating point
  • Scaling registers on all channels
  • Peer-to-peer i2o communication with percent-of-span and timed updates
  • Operating temperature: -40 to 70°C (-40 to 158°F)

 

How to Communicate with Modbus/TCP Modules from Ignition Software - 8501121
Setting Up and Communicating with Acromag Series 9xxEN-40xx and XTxxx1-xxx Modbus/TCP Modules and EtherStax™ Modbus/TCP from Ignition Software This document illustrates a procedure for configuring OPC tags intended for Acromag BusWorks® Series Modbus/TCP modules using Windows software from Inductive Automation. It is assumed that the user has a working knowledge of OPC, Modbus TCP, and...
How to Configure LabVIEW to Communicate with Modbus I/O Modules Via an OPC Server - 8500881
Configuring LabVIEW 2009 to Communicate with Acromag BusWorks and EtherStax Modbus I/O Modules via an OPC Server Introduction National Instruments™ LabVIEW can be used to monitor and control Acromag BusWorks ® and EtherStax ® Modbus I/O modules via an OPC server. A separate application note, Configuring Kepware KEPServerEX® 5.0 for communications with Acromag BusWorks and EtherStax...
How to Communicate to Ethernet Modules from Red Lion HMIs - 8500874
How to Communicate to Acromag Ethernet Modules from Red Lion HMIs Red Lion HMIs This document illustrates a procedure for configuring message commands for Acromag Ethernet modules using the Red Lion Crimson 2.0 software. It is assumed that the user has a working knowledge of the Crimson 2.0 software, as well as a Red Lion...
AMTN-DEMO (Log in to download the file)
ATMX Demo Software (Log in to download the file)
ESW-MBLIB-DEMO (Log in to download the file)
Ethernet IP EDS For XTxxx2-000 Modules (Log in to download the file)
EtherStax Modbus Copy Utility Software (Log in to download the file)
  • Compare

    20RM-16-DIN: 19” rack-mount kit with DIN rail

    • 19" rack-mount kit with DIN rail
    Select options
  • Compare

    4001 Serial Cables

    5-foot ribbon cable, DB25 male and 26-pin female IDC connectors, for 3B/5B backpanel to Ethernet I/O module connection
    Select options
  • Compare

    5020-350: Toroidal AC Current Sensor

    • AC Current Sensor to precondition an AC current input signal
    • Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
    Select options
  • Compare

    5035 Series: Ethernet Cables

    • Ethernet straight cable, CAT5
    • Ethernet crossover cable, CAT5E
    • Low EMI Double-Shielded Ethernet Patch Cable
    Select options
  • Compare

    900EN: 5-Port Ethernet Switch

    • 10/100Mbps
    • 15 to 36V DC power supply required
    • Five shielded RJ-45 sockets, 8-pin, 10Base-T / 100Base-TX
    Acromag’s five-port Ethernet switch is specially designed for use in industrial applications. Rugged construction and a variety of security features ensure reliable operation under demanding conditions.
    Select options
  • Compare

    AMTN, AMTX: ActiveX / .NET Controls for Modbus I/O

    • Modbus/TCP or Modbus/RTU
    • These ActiveX / .NET software controls provide a fast, easy way to communicate with any Modbus slave devices connected to your PC.
    • Get your Visual Basic, Visual C, .NET, Excel, or other compatible applications talking Modbus protocol within minutes.
    Select options
  • Compare

    DIN Rail: Type T

    • DIN Rail Strip, Type T
    Select options
  • Compare

    ESW-MBLIB: Ethernet Modbus C Library Software

    • Universal support for five operating systems
    • C source code provided
    • Demo program included
    Select options
  • Compare

    EtherStax Mounting Kits

    • EtherStax mounting accessories
    Select options
  • Compare

    IMC-100A: 10/100BaseTX to 100BaseFX Industrial Media Converter

    • UTP to Fiber Media Converter
    • RJ45 Port Supports Auto MDI/MDI-X Function
     
    Select options
  • Compare

    PS5R: Slim Line Power Supplies

    • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
    • Universal Input (85-264V AC / 100-370V DC)
    • Lightweight and compact size
     
    Select options
  • Compare

    Terminal Block Replacements

    • Simplifies wiring connections on Acromag I/O Modules
    • Barrier strip or spring clamp terminal block kits
    • Provide safe and secure wiring connections
    Select options
  • Compare

    USB-to-Ethernet Adapter

    Simplifies configuration of Acromag Ethernet I/O Modules Prevents disruption of existing LANs This device is a USB-to-Ethernet adapter that you can use to communicate with any Acromag Ethernet I/O product for the purpose of setup and re-configuration for your application. It is recommended for initial communication with Acromag Ethernet devices so that you do not have to disrupt your existing network connection.
    Select options

Additional information

Weight 80 oz
Dimensions 9 × 2.5 × 7.25 in
Part Number

ES2153-0000: 2 Cu ports, IP20 enclosure, ES2153-0010: 2 Cu ports, open board (no IP20 enclosure), ES2153-1000: Cu and fiber ports, IP20 enclosure, ES2153-1010: Cu and fiber ports, open board (no IP20 enclosure)

Communication

i2o Peer-to-Peer, Modbus TCP/IP, Modbus UDP/IP

Product Series

EtherStax Series

  • Description

    ES2153: Ethernet Analog Input Modules Description

    These EtherStax® I/O units provide a rugged, high-density, and high-speed solution to interface a large quantity of analog input signals. Units accept 16 single-ended analog voltage inputs and 16 single-ended current inputs.

    A DB25 port supports an alternate interface of voltage inputs from microBlox® uB signal conditioning modules. This combination of high-density analog current and voltage inputs is ideal for many sensor interface applications in remote zones.

    EtherStax units are built and tested for high reliability and dependable performance in hostile environments. Available in an aluminum enclosure or as an open circuit board, both formats stack vertically to maintain a very small footprint.

    Performance Specifications

    Analog Field Inputs

    Input Channel Configuration: 16 single-ended analog voltage inputs and 16 single-ended analog current inputs.

    Input Ranges (select on per-channel basis): ±5V, ±10V, ±20mA, 0-20mA, or 4-20mA DC.

    Input Scaling (per-channel basis): Floating Point Format: IEEE-754.

    Input Resolution: 16-bit maximum, 0.00166% (1 part in 60,000).

    Input Accuracy:
    Current Input: Better than 0.1% of range.
    Voltage Input: Better than 0.05% of range.

    Input Impedance: Voltage: 4M ohms minimum.

    Current: 100 ohms.

    Input Scan Groups and Scan Times:
    Eight user-enabled 4-channel scan groups.
    770µS update/group (5mS for all 32 channels) with averaging, loopback, and totalization functions disabled.

    Input Overvoltage Protection: Bipolar Transient Voltage Suppressers (TVS), 18V clamp level typical.

    Noise Rejection: CMR (50-60Hz): Better than -72dB.

    Sample Averaging (user-configurable): 0-500 samples. One register for all channels.

    Local Alarm Output

    Configuration: Failsafe or non-failsafe (user-configurable) relay trips on power or link-loss failure.

    Type: SPST-NO, 1 Form A, Class I, Division II approved.

    Rating:
    3A @ 24V DC/250V AC, 100,000 cycles general.
    2A @ 24V DC/250V AC, Hazardous locations.

    Maximum Switching Voltage and Power: 250V AC / 750VA, 125V DC / 90W.

    Ethernet Interface

    Internal Switch or Hub/Repeater: Dual-port Ethernet switch. User-configurable as a true switch (default mode) or low-latency hub.

    Network Connector [10/100 Base-T(X)Copper]: One or two 8-pin RJ-45 connectors. Automatic MDI/MDI-X. 100m communication distance.

    Network Connector (100 Base-FX Fiber-optic): One multi-mode with SC connector. 2km communication distance. Full/half-duplex, selectable.

    Protocols: Modbus TCP/IP, UDP/IP, i2o peer-to-peer.

    Addressing: StaticIP, DHCP, BootP.

    Ethernet Modbus TCP/IP Sockets/Sessions: 1-10 socket/sessions user-configurable.

    Ethernet Redundancy: Compatible with STP, RSTP, or any ring scheme.

    i2o® Peer-to-Peer Communication

    Each port of 8 input channels can be mapped to output ports of two ES215x units. Updates based on time (100mS resolution) or percent of range change (0.1% resolution).

    Environmental

    Operating and Storage Temperature:
    Operating: -40 to 70°C (-40 to 158°F).
    Storage: -40 to 85°C (-40 to 185°F).

    Power Requirements:
    18-36V DC. Redundant, diode-coupled terminals.
    4.8W (copper ports), 5.8W (fiber-optic ports).

    Isolation: I/O, power, relay and Ethernet port-to-port.

    Peak: 1500V AC, ANSI/ISA-82.01-1988.

    Continuous: 250V AC, 354V DC (150V AC ch-ch).

    Enclosure and Physical

    Housing Classification and Dimensions:
    IP20:  8.226 x 2.444 x 7.25”, 4 lbs. packed.
    PCB:  7.920 x 1.875 x 7.25”, 1.65 lbs. packed.

    Safety Approvals: UL/cUL Listed.

    Hazardous Locations: Class I; Div 2; A, B, C, D.Open board units: UL Recognized.

    Shock and Vibration Immunity (in enclosure):
    Mechanical Shock: 50g (3ms), 30g (11ms)
    Random Vibration: 5g, (5-500Hz)

     

  • Features & Benefits

    • 32-channel high-density combination of analog current and voltage inputs
    • DB25 port for alternate voltage inputs from microBlox uB signal conditioning backpanels
    • 3-way isolation and surge suppression
    • High-resolution 16-bit A/D
    • High-speed scanning for 10 millisecond update of all 32 channels
    • Automatic zero/span calibration
    • On-demand self-test verifies calibration
    • Web browser configuration
    • User-configurable sample averaging and integration/totalization function with non-volatile registers
    • Dual-format data registers support 16-bit integers or 32-bit floating point
    • Scaling registers on all channels
    • Peer-to-peer i2o communication with percent-of-span and timed updates
    • Operating temperature: -40 to 70°C (-40 to 158°F)

     

  • Tech Papers

    How to Communicate with Modbus/TCP Modules from Ignition Software - 8501121
    Setting Up and Communicating with Acromag Series 9xxEN-40xx and XTxxx1-xxx Modbus/TCP Modules and EtherStax™ Modbus/TCP from Ignition Software This document illustrates a procedure for configuring OPC tags intended for Acromag BusWorks® Series Modbus/TCP modules using Windows software from Inductive Automation. It is assumed that the user has a working knowledge of OPC, Modbus TCP, and...
    How to Configure LabVIEW to Communicate with Modbus I/O Modules Via an OPC Server - 8500881
    Configuring LabVIEW 2009 to Communicate with Acromag BusWorks and EtherStax Modbus I/O Modules via an OPC Server Introduction National Instruments™ LabVIEW can be used to monitor and control Acromag BusWorks ® and EtherStax ® Modbus I/O modules via an OPC server. A separate application note, Configuring Kepware KEPServerEX® 5.0 for communications with Acromag BusWorks and EtherStax...
    How to Communicate to Ethernet Modules from Red Lion HMIs - 8500874
    How to Communicate to Acromag Ethernet Modules from Red Lion HMIs Red Lion HMIs This document illustrates a procedure for configuring message commands for Acromag Ethernet modules using the Red Lion Crimson 2.0 software. It is assumed that the user has a working knowledge of the Crimson 2.0 software, as well as a Red Lion...
  • Specs & Data Sheets

  • Software

    AMTN-DEMO (Log in to download the file)
    ATMX Demo Software (Log in to download the file)
    ESW-MBLIB-DEMO (Log in to download the file)
    Ethernet IP EDS For XTxxx2-000 Modules (Log in to download the file)
    EtherStax Modbus Copy Utility Software (Log in to download the file)
  • Accessories

    • Compare

      20RM-16-DIN: 19” rack-mount kit with DIN rail

      • 19" rack-mount kit with DIN rail
      Select options
    • Compare

      4001 Serial Cables

      5-foot ribbon cable, DB25 male and 26-pin female IDC connectors, for 3B/5B backpanel to Ethernet I/O module connection
      Select options
    • Compare

      5020-350: Toroidal AC Current Sensor

      • AC Current Sensor to precondition an AC current input signal
      • Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
      Select options
    • Compare

      5035 Series: Ethernet Cables

      • Ethernet straight cable, CAT5
      • Ethernet crossover cable, CAT5E
      • Low EMI Double-Shielded Ethernet Patch Cable
      Select options
    • Compare

      900EN: 5-Port Ethernet Switch

      • 10/100Mbps
      • 15 to 36V DC power supply required
      • Five shielded RJ-45 sockets, 8-pin, 10Base-T / 100Base-TX
      Acromag’s five-port Ethernet switch is specially designed for use in industrial applications. Rugged construction and a variety of security features ensure reliable operation under demanding conditions.
      Select options
    • Compare

      AMTN, AMTX: ActiveX / .NET Controls for Modbus I/O

      • Modbus/TCP or Modbus/RTU
      • These ActiveX / .NET software controls provide a fast, easy way to communicate with any Modbus slave devices connected to your PC.
      • Get your Visual Basic, Visual C, .NET, Excel, or other compatible applications talking Modbus protocol within minutes.
      Select options
    • Compare

      DIN Rail: Type T

      • DIN Rail Strip, Type T
      Select options
    • Compare

      ESW-MBLIB: Ethernet Modbus C Library Software

      • Universal support for five operating systems
      • C source code provided
      • Demo program included
      Select options
    • Compare

      EtherStax Mounting Kits

      • EtherStax mounting accessories
      Select options
    • Compare

      IMC-100A: 10/100BaseTX to 100BaseFX Industrial Media Converter

      • UTP to Fiber Media Converter
      • RJ45 Port Supports Auto MDI/MDI-X Function
       
      Select options
    • Compare

      PS5R: Slim Line Power Supplies

      • 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
      • Universal Input (85-264V AC / 100-370V DC)
      • Lightweight and compact size
       
      Select options
    • Compare

      Terminal Block Replacements

      • Simplifies wiring connections on Acromag I/O Modules
      • Barrier strip or spring clamp terminal block kits
      • Provide safe and secure wiring connections
      Select options
    • Compare

      USB-to-Ethernet Adapter

      Simplifies configuration of Acromag Ethernet I/O Modules Prevents disruption of existing LANs This device is a USB-to-Ethernet adapter that you can use to communicate with any Acromag Ethernet I/O product for the purpose of setup and re-configuration for your application. It is recommended for initial communication with Acromag Ethernet devices so that you do not have to disrupt your existing network connection.
      Select options
  • Additional information

    Additional information

    Weight 80 oz
    Dimensions 9 × 2.5 × 7.25 in
    Part Number

    ES2153-0000: 2 Cu ports, IP20 enclosure, ES2153-0010: 2 Cu ports, open board (no IP20 enclosure), ES2153-1000: Cu and fiber ports, IP20 enclosure, ES2153-1010: Cu and fiber ports, open board (no IP20 enclosure)

    Communication

    i2o Peer-to-Peer, Modbus TCP/IP, Modbus UDP/IP

    Product Series

    EtherStax Series