966EN: Ethernet Temperature Input Modules
Please sign in or register to see model options and to add products to your cart.
Product short description:
- 4 or 6-channel RTD/resistance input
- Ethernet/IP, Modbus TCP/IP
- i2o peer-to-peer available for Modbus TCP/IP 6-channel only
These modules provide an isolated Ethernet network interface for up to six input channels. Multi-range inputs accept signals from a variety of sensors and devices. High-resolution, low noise, A/D converters deliver high accuracy and reliability. Three-way isolation further improves the system performance.
- Description
- Features & Benefits
- Tech Papers
- Specs & Data Sheets
- Software
- Accessories
- Additional information
These modules provide an isolated Ethernet network interface for up to six input channels. Multi-range inputs accept signals from a variety of sensors and devices. High-resolution, low noise, A/D converters deliver high accuracy and reliability. 3-way isolation further improves the system performance.
Input Ranges:Input ranges are selectable for a 3-channel group
RTD: 2-wire and 3-wire RTDs are supported. Platinum 100 ohm (alpha = 1.3850 or 1.3911)
Nickel 120 ohm
Copper 10 ohm
Resistance: 0 to 500 ohms
Network Communication:
Ethernet/IP
Modbus TCP/IP, (i2o® peer-to-peer available for Modbus TCP/IP 6 channel only)
10/100Mbps with automatic data rate negotiation
Power Requirement: 15 to 36V DC supply (2 Watts) required
Approvals:
CE/ATEX marked. UL, cUL listed, Class I; Div. 2; Groups A, B, C, D
EtherNet/IP, Modbus/TCP conformance tested
Performance Specifications
Input
Accuracy:
Input Type Input Range Accuracy (typical)
Pt 100 ohm -200 to 850°C ±0.25°C
Ni 120 ohm -80 to 320°C ±0.25°C
Cu 10 ohm 200 to 260°C ±1.25°C
Resistance 0 to 500 ohms ±0.05 ohms
RTD Break Detection: Upscale or downscale selection applies to all channels
Noise Rejection:
Normal Mode: Better than 40dB @ 60Hz
Common Mode: Better than 130dB @ 60Hz
Input Filter Bandwidth: -3dB at 3Hz, typical
Input Conversion Rate: 80mS per channel
Excitation Current: 1mA DC typical, all RTD types
Environmental
Ambient Temperature and Humidity
Operating: -25 to 70°C (-13 to 158°F)
Storage: -40 to 85°C (-40 to 185°F)
Relative humidity: 5 to 95%, non-condensing
Isolation:
1500V AC for 60 seconds or 250V AC continuous
3-way isolation between I/O, network, and power. Inputs share a common.
NOTE: i2o function only available on 6-channel Modbus TCP/IP modules
- Configurable from standard web browser
- EtherNet/IP™ or Ethernet ModbusTCP/IP communication with automatic 10/100Mbps data rate negotiation
- 6-input stand-alone module has much lower start-up cost than multi-piece block I/O systems
- i2o function (available ONLY with Modbus TCP/IP 6-channel) enables direct input-to-output communication without a network controller
- Versatile RTD or ohmic inputs support a wide variety of industrial sensors and devices
- RTD break detection (upscale or downscale) identifies sensor wiring failures
- High-resolution 16-bit sigma delta A/D converters ensure precise, high accuracy measurements
- Compact packaging with pluggable terminals saves space and simplifies wiring
- Wide operational temperature range permits installation in extreme environments; -25°C to 70°C (-13° to 158°F)
- Approvals: CE/ATEX marked; UL, cUL listed, Class 1 Div 2 Groups A, B, C, D; EtherNet/IP, Modbus/TCP conformance tested
Specifications
Manuals
Brochure
-
4001 Serial Cables
5-foot ribbon cable, DB25 male and 26-pin female IDC connectors, for 3B/5B backpanel to Ethernet I/O module connection$100Select options -
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
$50Select options -
5035 Series: Ethernet Cables
- Ethernet straight cable, CAT5
- Ethernet crossover cable, CAT5E
- Low EMI Double-Shielded Ethernet Patch Cable
$45 – $115Select options -
900EN: 5-Port Ethernet Switch
- 10/100Mbps
- 15 to 36V DC power supply required
- Five shielded RJ-45 sockets, 8-pin, 10Base-T / 100Base-TX
$350Select options -
AMTN, AMTX: ActiveX / .NET Controls for Modbus I/O
- Modbus/TCP or Modbus/RTU
- These ActiveX / .NET software controls provide a fast, easy way to communicate with any Modbus slave devices connected to your PC.
- Get your Visual Basic, Visual C, .NET, Excel, or other compatible applications talking Modbus protocol within minutes.
$270 – $370Select options -
ESW-MBLIB: Ethernet Modbus C Library Software
- Universal support for five operating systems
- C source code provided
- Demo program included
$0 – $350Select options -
IMC-100A: 10/100BaseTX to 100BaseFX Industrial Media Converter
- UTP to Fiber Media Converter
- RJ45 Port Supports Auto MDI/MDI-X Function
$250Select options -
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
$100 – $255Select options -
Terminal Block Replacements
- Simplifies wiring connections on Acromag I/O Modules
- Barrier strip or spring clamp terminal block kits
- Provide safe and secure wiring connections
$35 – $45Select options -
USB-to-Ethernet Adapter
Simplifies configuration of Acromag Ethernet I/O Modules Prevents disruption of existing LANs This device is a USB-to-Ethernet adapter that you can use to communicate with any Acromag Ethernet I/O product for the purpose of setup and re-configuration for your application. It is recommended for initial communication with Acromag Ethernet devices so that you do not have to disrupt your existing network connection.$85Select options
Additional information
Weight | 10 oz |
---|---|
Dimensions | 4.5 × 1.5 × 5 in |
Part Number | 966EN-4004: Modbus TCP/IP, 4 channel, 966EN-4006: Modbus TCP/IP and i2o protocol, 6 channel, 966EN-6004: Ethernet/IP, 4 channel, 966EN-6006: Ethernet/IP, 6 channel |
Communication | Ethernet/IP, i2o Peer-to-Peer, Modbus TCP/IP |
Product Series | BusWorks 900EN Series |
Configuration | Built-in Web pages |
-
Description
These modules provide an isolated Ethernet network interface for up to six input channels. Multi-range inputs accept signals from a variety of sensors and devices. High-resolution, low noise, A/D converters deliver high accuracy and reliability. 3-way isolation further improves the system performance.
Input Ranges:Input ranges are selectable for a 3-channel group
RTD: 2-wire and 3-wire RTDs are supported. Platinum 100 ohm (alpha = 1.3850 or 1.3911)
Nickel 120 ohm
Copper 10 ohm
Resistance: 0 to 500 ohms
Network Communication:
Ethernet/IP
Modbus TCP/IP, (i2o® peer-to-peer available for Modbus TCP/IP 6 channel only)
10/100Mbps with automatic data rate negotiation
Power Requirement: 15 to 36V DC supply (2 Watts) required
Approvals:
CE/ATEX marked. UL, cUL listed, Class I; Div. 2; Groups A, B, C, D
EtherNet/IP, Modbus/TCP conformance testedPerformance Specifications
Input
Accuracy:
Input Type Input Range Accuracy (typical)
Pt 100 ohm -200 to 850°C ±0.25°C
Ni 120 ohm -80 to 320°C ±0.25°C
Cu 10 ohm 200 to 260°C ±1.25°C
Resistance 0 to 500 ohms ±0.05 ohmsRTD Break Detection: Upscale or downscale selection applies to all channels
Noise Rejection:
Normal Mode: Better than 40dB @ 60Hz
Common Mode: Better than 130dB @ 60Hz
Input Filter Bandwidth: -3dB at 3Hz, typical
Input Conversion Rate: 80mS per channel
Excitation Current: 1mA DC typical, all RTD typesEnvironmental
Ambient Temperature and Humidity
Operating: -25 to 70°C (-13 to 158°F)
Storage: -40 to 85°C (-40 to 185°F)
Relative humidity: 5 to 95%, non-condensing
Isolation:
1500V AC for 60 seconds or 250V AC continuous
3-way isolation between I/O, network, and power. Inputs share a common.NOTE: i2o function only available on 6-channel Modbus TCP/IP modules
-
Features & Benefits
- Configurable from standard web browser
- EtherNet/IP™ or Ethernet ModbusTCP/IP communication with automatic 10/100Mbps data rate negotiation
- 6-input stand-alone module has much lower start-up cost than multi-piece block I/O systems
- i2o function (available ONLY with Modbus TCP/IP 6-channel) enables direct input-to-output communication without a network controller
- Versatile RTD or ohmic inputs support a wide variety of industrial sensors and devices
- RTD break detection (upscale or downscale) identifies sensor wiring failures
- High-resolution 16-bit sigma delta A/D converters ensure precise, high accuracy measurements
- Compact packaging with pluggable terminals saves space and simplifies wiring
- Wide operational temperature range permits installation in extreme environments; -25°C to 70°C (-13° to 158°F)
- Approvals: CE/ATEX marked; UL, cUL listed, Class 1 Div 2 Groups A, B, C, D; EtherNet/IP, Modbus/TCP conformance tested
-
Tech Papers
How to Connect Acromag Series 9xxEN Modules Via RadioLinx Ethernet ModemsObjective: The purpose of this document is to provide a procedure for connecting an Acromag Series 9xxEN I/O Module to an existing network via RadioLinx Ethernet Modems. Background – IP Addresses Any TCP/IP packet contains two addresses: a unique fixed MAC address, and a unique IP address. To communicate on the Internet, computers must have...How to Communicate with Acromag Modbus/TCP Modules from Ignition Software Application NoteCommunicating with Ignition Software This document illustrates a procedure for configuring OPC tags intended for Acromag Busworks® Series Modbus/TCP modules using Windows software from Inductive Automation. It is assumed that the user has a working knowledge of OPC, Modbus TCP, and Ignition software. Product Features: BusWorks® Series 9xxEN Modules w/Modbus/TCP BusWorks® Series XT1xx1 Modules w/...How to Connect to Acromag Ethernet I/O Devices Application NoteGetting Connected to Acromag Ethernet I/O Devices These instructions summarize the basic steps you will have to take in order to initially connect an Acromag Ethernet I/O product to your Personal Computer (PC) or laptop. To connect an Ethernet device to your PC, consult with your network administrator and either temporarily change the TCP/IP configuration...How to Connect Acromag Series 900EN Ethernet Modules to Your PC Application NoteObjective: The purpose of this document is to provide a procedure for assigning a unique IP address to a second network interface card installed in a personal computer for the purpose of communicating with an Acromag Series 9xxEN Ethernet I/O Module. A procedure for accomplishing IP address assignment is provided using Windows 98, Windows ME, Windows...How to Communicate with Acromag Series 9xxEN-60xx & XTxxx2-xxx Ethernet/IP Modules from Compact Logix Devices Application NoteCommunicating with Acromag Series 9xxEN-60xx and XTxxx2-xxx Ethernet/IP Modules from Compact Logix Controllers This document illustrates a procedure for configuring message commands intended for Acromag Busworks® Series Ethernet/IP modules using ladder logic programming software and a Compact Logix Programmable Controller. It is assumed that the user has a working knowledge of ladder logic programming, the...How to Communicate to Acromag Series 9xxEN-6xxx & XTxx2-xxx Ethernet Modules in an Allen Bradley ControlLogix System Application NoteEthernet Modules in a ControlLogix System Objective: This document illustrates a procedure for integrating the Acromag Series 9xxEN-6xxx modules into the Allen Bradley control system as a third-party generic module. The reference model for this procedure is the Model 961EN-6006. It is assumed that the Acromag module has been assigned a static IP address and...How to Configure Kepware KEPServerEX 5.0 for Communications with Acromag BusWorks Modbus I/O Modules Application NoteConfiguring Kepware KEPServerEX 5.0 for Communications with Acromag BusWorks Modbus I/O modules. Introduction This document provides example steps for configuring the Kepware KEPServerEX OPC Server for communications with Acromag Busworks Modbus RTU and Modbus TCP/IP Distributed I/O Modules. Once the server is configured, data may be read from or written to the I/O module using...How to Configure LabVIEW 2009 to Communicate with Acromag BusWorks and EtherStax Modbus I/O Modules Via an OPC Server Application NoteIntroduction National Instruments LabVIEW can be used to monitor and control Acromag Busworks and Etherstax Modbus I/O Modules via an OPC server. A separate application note, Configuring Kepware KEPServerEX 5.0 for Communications with Acromag Busworks and Etherstax Modbus I/O Modules, outlines configuration of a KEPServerEX OPC server. This document focuses on setting up controls and...How to Configure Omron CJ2H PLC's with Ethernet/IP for Use with Acromag Ethernet/IP Remote I/O Application NotePurpose: Acromag Ethernet/IP I/O with Omron CJ2H PLC’s This document walks the user through the configuration of the Cx-One Network Configurator software that is used in conjunction with Omron CJ2H PLC’s. It is assumed that the user has a working knowledge of the PLC and Cx-One software. Configuring the CxOne “Network Configurator” Start the Cx-One...How to Communicate to Acromag Series 9xxEN-60xx Ethernet Modules using PCCC from Compact Logix Devices Application NotePCCC Messaging with CompactLogix This document illustrates a procedure for configuring PCCC message commands for Acromag Series 9xxEN Ethernet/IP modules using ladder logic programming and a Compact Logix Controller. It is assumed that the user has a working knowledge of ladder logic programming, the RSLogix5000 software, and the Compact Logix hardware. Configuring PCCC Messaging Using...How to Communicate to Ethernet Modules from Legacy Allen Bradley or Rockwell Automation Devices Application NoteThis document illustrates a procedure for configuring message commands for Acromag Series 9xxEN Ethernet/IP modules using ladder logic programming and an SLC5\05 Programmable Logic Controller. It is assumed that the user has a working knowledge of ladder logic programming, the RSLogix500 software, and the SLC 5\05 hardware. Setup of PCCC Communication to Series 9xxEN-60xx I/O...How to Configure the Wonderware MBENET I/O Server to Communicate with the Acromag 9xxEN Ethernet Modules Application NoteWonderware MBENET The purpose of this document is to provide a procedure for configuring MBENET I/O Server (ie: Modicon Ethernet I/O Server) to communicate with an Acromag Series 9xxEN Ethernet I/O Module. It is assumed that the user has a working knowledge of Wonderware and how to link the Wonderware application to the Wonderware I/O...How to Communicate to Acromag Series Ethernet Modules from Red Lion HMIs Application NoteRed Lion HMIs This document illustrates a procedure for configuring message commands for Acromag Ethernet modules using the Red Lion Crimson 2.0 Software. It is assumed that the user has a working knowledge of the Crimson 2.0 software, as well as a Red Lion HMI. Setting up Communications From a new or existing project, double... -
Specs & Data Sheets
Specifications
Manuals
Brochure
-
Software
-
Accessories
-
4001 Serial Cables
5-foot ribbon cable, DB25 male and 26-pin female IDC connectors, for 3B/5B backpanel to Ethernet I/O module connection$100Select options -
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
$50Select options -
5035 Series: Ethernet Cables
- Ethernet straight cable, CAT5
- Ethernet crossover cable, CAT5E
- Low EMI Double-Shielded Ethernet Patch Cable
$45 – $115Select options -
900EN: 5-Port Ethernet Switch
- 10/100Mbps
- 15 to 36V DC power supply required
- Five shielded RJ-45 sockets, 8-pin, 10Base-T / 100Base-TX
$350Select options -
AMTN, AMTX: ActiveX / .NET Controls for Modbus I/O
- Modbus/TCP or Modbus/RTU
- These ActiveX / .NET software controls provide a fast, easy way to communicate with any Modbus slave devices connected to your PC.
- Get your Visual Basic, Visual C, .NET, Excel, or other compatible applications talking Modbus protocol within minutes.
$270 – $370Select options -
ESW-MBLIB: Ethernet Modbus C Library Software
- Universal support for five operating systems
- C source code provided
- Demo program included
$0 – $350Select options -
IMC-100A: 10/100BaseTX to 100BaseFX Industrial Media Converter
- UTP to Fiber Media Converter
- RJ45 Port Supports Auto MDI/MDI-X Function
$250Select options -
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
$100 – $255Select options -
Terminal Block Replacements
- Simplifies wiring connections on Acromag I/O Modules
- Barrier strip or spring clamp terminal block kits
- Provide safe and secure wiring connections
$35 – $45Select options -
USB-to-Ethernet Adapter
Simplifies configuration of Acromag Ethernet I/O Modules Prevents disruption of existing LANs This device is a USB-to-Ethernet adapter that you can use to communicate with any Acromag Ethernet I/O product for the purpose of setup and re-configuration for your application. It is recommended for initial communication with Acromag Ethernet devices so that you do not have to disrupt your existing network connection.$85Select options
-
Additional information
Additional information
Weight 10 oz Dimensions 4.5 × 1.5 × 5 in Part Number 966EN-4004: Modbus TCP/IP, 4 channel, 966EN-4006: Modbus TCP/IP and i2o protocol, 6 channel, 966EN-6004: Ethernet/IP, 4 channel, 966EN-6006: Ethernet/IP, 6 channel
Communication Ethernet/IP, i2o Peer-to-Peer, Modbus TCP/IP
Product Series BusWorks 900EN Series
Configuration Built-in Web pages