Click to zoom

Please sign in or register to see model options and to add products to your cart.

Product short description:
  • 12-channel single-ended analog current or voltage input
  • Ethernet/IP or Modbus TCP/IP communication

These modules provide an isolated Ethernet network interface for twelve analog input channels. Compact design saves space and lowers system costs. Multi-range inputs accept signals from a variety of sensors and devices. High-resolution, low noise, A/D converters deliver high accuracy and reliability.

963EN, 964EN: Ethernet Analog Input Modules Description

963EN: 12 DC current input channels
964EN: 12 DC voltage input channels

These modules provide an isolated Ethernet network interface for twelve analog input channels. Compact design saves space and lowers system costs. Multi-range inputs accept signals from a variety of sensors and devices. High-resolution, low noise, A/D converters deliver high accuracy and reliability.

Input Ranges: Ranges user-selectable on each terminal block for a group of four input channels (4-channel basis).

DC Current
0 to 1mA, 0 to 11mA, 0 to 20mA, 4 to 20mA.
0 to 20 amps AC (with optional AC sensor).

DC Voltage: ±1V, ±5V, or ±10V DC.

Network Communication: EtherNet/IP or Modbus TCP/IP 10/100Mbps.

Power Requirement: 15 to 36V DC supply (2 Watts) required.

Approvals
CE/ATEX marked. UL, cUL listed, Class I; Div. 2; Groups A, B, C, D.
EtherNet/IP, Modbus/TCP conformance tested.

Learn more about the 900EN Series and view all models >

963EN, 964EN: Ethernet Analog Input Modules Features & Benefits

  • Configurable from standard web browser
  • EtherNet/IP® or Ethernet Modbus TCP/IP communication with automatic 10/100Mbps data rate negotiation
  • 12-input module has very low cost per channel
  • Universal DC inputs support a wide variety of industrial sensors and signals
  • High-resolution 16-bit sigma-delta A/D converters ensure precise, high accuracy measurements
  • Wide operational temperature range permits installation in extreme environments
How to Connect Ethernet I/O Modules with RadioLinx Ethernet Modems - 8500770
Connecting Acromag Series 900EN I/O Modules to an existing network with RadioLinx Ethernet Modems Background – IP Addresses Any TCP/IP packet contains two addresses: a unique fixed MAC address, and a unique IP address. To communicate on the Internet, computers must have unique identifiers in order to differentiate one computer from another. This is accomplished...
How to Communicate with Modbus/TCP Modules from Ignition Software - 8501121
Setting Up and Communicating with Acromag Series 9xxEN-40xx and XTxxx1-xxx Modbus/TCP Modules and EtherStax™ Modbus/TCP from Ignition Software This document illustrates a procedure for configuring OPC tags intended for Acromag BusWorks® Series Modbus/TCP modules using Windows software from Inductive Automation. It is assumed that the user has a working knowledge of OPC, Modbus TCP, and...
How to Connect to Acromag Ethernet I/O Devices - 8500815
Getting Connected to Acromag Ethernet I/O Devices These instructions summarize the basic steps you will have to take in order to initially connect an Acromag Ethernet I/O product to your Personal Computer (PC) or laptop. To connect an Ethernet device to your PC, consult with your network administrator. Either temporarily change the TCP/IP configuration of...
How to Connect Acromag 900EN Ethernet Modules to Your PC - 8500734
Connecting Acromag Series 900EN Ethernet Modules to Your PC Objective: The purpose of this document is to provide a procedure for assigning a unique IP address to a second network interface card installed in a personal computer for the purpose of communicating with an Acromag Series 9xxEN Ethernet I/O Module. A procedure for accomplishing IP address...
How to Communicate with Acromag Ethernet/IP Modules from CompactLogix Controllers - 8500762
Communicating with Acromag Series 9xxEN-60xx,  XTxxx2-xxx, and NTE2xxx-xxxx Ethernet/IP™ Modules from CompactLogix™ PLC Device This document illustrates a procedure for configuring message commands intended for Acromag Busworks® Series Ethernet/IP modules using Ladder Logic programming software in addition to a CompactLogix Programmable Controller. It is assumed that the user has a working knowledge of; Ladder Logic...

Manuals

963EN-4012, 964EN-4012 User Manual (Log in to download the file)

963EN-6012, 964EN-6012 User Manual (Log in to download the file)

ESW-MBLIB-DEMO (Log in to download the file)
AMTx: Modbus TCP/IP Software Information Page (Log in to download the file)
Ethernet IP EDS for 9xxEN-6xxx Modules (Log in to download the file)
  • Compare

    5035 Series: Ethernet Cables

    • Ethernet straight cable, CAT5
    • Ethernet crossover cable, CAT5E
    • Low EMI Double-Shielded Ethernet Patch Cable
    Select options

Additional information

Weight 10 oz
Dimensions 4.5 × 1.5 × 5 in
Product Number

963EN-4012: Ethernet Modbus TCP/IP, DC current, 963EN-6012: Ethernet/IP, DC current, 964EN-4012: Ethernet Modbus TCP/IP, DC voltage, 964EN-6012: Ethernet/IP, DC voltage

Communication

Ethernet/IP, Modbus TCP/IP

Product Series

BusWorks 900EN Series

Power Type

DC Power

  • Description

    963EN, 964EN: Ethernet Analog Input Modules Description

    963EN: 12 DC current input channels
    964EN: 12 DC voltage input channels

    These modules provide an isolated Ethernet network interface for twelve analog input channels. Compact design saves space and lowers system costs. Multi-range inputs accept signals from a variety of sensors and devices. High-resolution, low noise, A/D converters deliver high accuracy and reliability.

    Input Ranges: Ranges user-selectable on each terminal block for a group of four input channels (4-channel basis).

    DC Current
    0 to 1mA, 0 to 11mA, 0 to 20mA, 4 to 20mA.
    0 to 20 amps AC (with optional AC sensor).

    DC Voltage: ±1V, ±5V, or ±10V DC.

    Network Communication: EtherNet/IP or Modbus TCP/IP 10/100Mbps.

    Power Requirement: 15 to 36V DC supply (2 Watts) required.

    Approvals
    CE/ATEX marked. UL, cUL listed, Class I; Div. 2; Groups A, B, C, D.
    EtherNet/IP, Modbus/TCP conformance tested.

    Learn more about the 900EN Series and view all models >

    963EN, 964EN: Ethernet Analog Input Modules Features & Benefits

    • Configurable from standard web browser
    • EtherNet/IP® or Ethernet Modbus TCP/IP communication with automatic 10/100Mbps data rate negotiation
    • 12-input module has very low cost per channel
    • Universal DC inputs support a wide variety of industrial sensors and signals
    • High-resolution 16-bit sigma-delta A/D converters ensure precise, high accuracy measurements
    • Wide operational temperature range permits installation in extreme environments
  • Tech Papers

    How to Connect Ethernet I/O Modules with RadioLinx Ethernet Modems - 8500770
    Connecting Acromag Series 900EN I/O Modules to an existing network with RadioLinx Ethernet Modems Background – IP Addresses Any TCP/IP packet contains two addresses: a unique fixed MAC address, and a unique IP address. To communicate on the Internet, computers must have unique identifiers in order to differentiate one computer from another. This is accomplished...
    How to Communicate with Modbus/TCP Modules from Ignition Software - 8501121
    Setting Up and Communicating with Acromag Series 9xxEN-40xx and XTxxx1-xxx Modbus/TCP Modules and EtherStax™ Modbus/TCP from Ignition Software This document illustrates a procedure for configuring OPC tags intended for Acromag BusWorks® Series Modbus/TCP modules using Windows software from Inductive Automation. It is assumed that the user has a working knowledge of OPC, Modbus TCP, and...
    How to Connect to Acromag Ethernet I/O Devices - 8500815
    Getting Connected to Acromag Ethernet I/O Devices These instructions summarize the basic steps you will have to take in order to initially connect an Acromag Ethernet I/O product to your Personal Computer (PC) or laptop. To connect an Ethernet device to your PC, consult with your network administrator. Either temporarily change the TCP/IP configuration of...
    How to Connect Acromag 900EN Ethernet Modules to Your PC - 8500734
    Connecting Acromag Series 900EN Ethernet Modules to Your PC Objective: The purpose of this document is to provide a procedure for assigning a unique IP address to a second network interface card installed in a personal computer for the purpose of communicating with an Acromag Series 9xxEN Ethernet I/O Module. A procedure for accomplishing IP address...
    How to Communicate with Acromag Ethernet/IP Modules from CompactLogix Controllers - 8500762
    Communicating with Acromag Series 9xxEN-60xx,  XTxxx2-xxx, and NTE2xxx-xxxx Ethernet/IP™ Modules from CompactLogix™ PLC Device This document illustrates a procedure for configuring message commands intended for Acromag Busworks® Series Ethernet/IP modules using Ladder Logic programming software in addition to a CompactLogix Programmable Controller. It is assumed that the user has a working knowledge of; Ladder Logic...
  • Specs & Data Sheets

    Manuals

    963EN-4012, 964EN-4012 User Manual (Log in to download the file)

    963EN-6012, 964EN-6012 User Manual (Log in to download the file)

  • Software

    ESW-MBLIB-DEMO (Log in to download the file)
    AMTx: Modbus TCP/IP Software Information Page (Log in to download the file)
    Ethernet IP EDS for 9xxEN-6xxx Modules (Log in to download the file)
  • Accessories

    • Compare

      5035 Series: Ethernet Cables

      • Ethernet straight cable, CAT5
      • Ethernet crossover cable, CAT5E
      • Low EMI Double-Shielded Ethernet Patch Cable
      Select options
  • Additional information

    Additional information

    Weight 10 oz
    Dimensions 4.5 × 1.5 × 5 in
    Product Number

    963EN-4012: Ethernet Modbus TCP/IP, DC current, 963EN-6012: Ethernet/IP, DC current, 964EN-4012: Ethernet Modbus TCP/IP, DC voltage, 964EN-6012: Ethernet/IP, DC voltage

    Communication

    Ethernet/IP, Modbus TCP/IP

    Product Series

    BusWorks 900EN Series

    Power Type

    DC Power