961EN, 962EN: Ethernet Analog Input Modules
Product short description:
- 6-channel differential analog current or voltage input
- Ethernet/IP, Modbus TCP/IP
- i2o peer-to-peer available for Modbus TCP/IP only
These modules provide an isolated Ethernet network interface for six analog input channels. Differential inputs eliminate ground loops and thus the need for isolators in many applications. Multi-range inputs accept signals from a variety of sensors and devices. High-resolution, low noise, A/D converters deliver high accuracy and reliability.
- Description
- Features & Benefits
- Tech Papers
- Specs & Data Sheets
- Software
- Accessories
- Additional information
961EN: 6 DC current input channels
962EN: 6 DC voltage input channels
These modules provide an isolated Ethernet network interface for six analog input channels. Differential inputs eliminate ground loops and thus the need for isolators in many applications. Multi-range inputs accept signals from a variety of sensors and devices. High-resolution, low noise, A/D converters deliver high accuracy and reliability.
Input Ranges: Ranges are selectable for a 3-channel group
DC Current:
0 to 1mA, 0 to 11mA, 0 to 20mA, 4 to 20mA
0 to 20 amps AC (with optional AC sensor)
DC Voltage: ±78mV to ±10V DC (eight range options)
Network Communication:
Ethernet/IP
Modbus TCP/IP, i2o® peer-to-peer available for Modbus TCP/IP only
10/100Mbps
Power Requirement: 15 to 36V DC supply (2 Watts) required
Approvals:
CE/ATEX marked
UL, cUL listed, Class I; Div. 2; Groups A, B, C, D
EtherNet/IP, Modbus/TCP conformance tested
Performance Specifications
Input
Accuracy: Better than ±0.05% of span for nominal input ranges
Analog to Digital Converter (A/D): 16-bit Σ-Δ converter. 0.005% (1/20000) resolution
Noise Rejection: Normal Mode: Better than 40dB @ 60Hz
Common Mode: Better than 140dB @ 60Hz
Input Filter Bandwidth: -3dB at 3Hz, typical
Input Conversion Rate: 80mS per channel
DC Current Input Impedance:Â 25 ohms
DC Voltage Input Impedance: Greater than 110.5K ohms
Environmental
Ambient Operating Temperature: -25 to 70°C (-13 to 158°F)
Ambient Storage Temperature: -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity: 5 to 95%, non-condensing
Isolation: 1500V AC for 60 seconds or 250V AC continuous. 3-way isolation between I/O, network, and power
- Configurable from standard web browser
- EtherNet/IP® or Ethernet Modbus TCP/IP communication with automatic 10/100Mbps data rate negotiation
- 6-input stand-alone module is very economical
- i2o function (available ONLY with Modbus TCP/IP) enables direct input-to-output communication without a network controller
- Differential inputs eliminate ground loops
- Universal inputs support a variety of sensors
- High-resolution 16-bit sigma-delta A/D converters ensure precise, high accuracy measurements
- Compact packaging with pluggable terminals saves space and simplifies wiring
- Wide operational temperature range permits installation in extreme environments
Specifications
Manuals
Brochure
-
20RM-16-DIN: 19” rack-mount kit with DIN rail
- 19" rack-mount kit with DIN rail
$185Select options -
4001 Serial Cables
5-foot ribbon cable, DB25 male and 26-pin female IDC connectors, for 3B/5B backpanel to Ethernet I/O module connection$95Select options -
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
$50Select options -
5035 Series: Ethernet Cables
- Ethernet straight cable, CAT5
- Ethernet crossover cable, CAT5E
- Low EMI Double-Shielded Ethernet Patch Cable
$40 – $115Select options -
900EN: 5-Port Ethernet Switch
- 10/100Mbps
- 15 to 36V DC power supply required
- Five shielded RJ-45 sockets, 8-pin, 10Base-T / 100Base-TX
$340Select options -
AMTN, AMTX: ActiveX / .NET Controls for Modbus I/O
- Modbus/TCP or Modbus/RTU
- These ActiveX / .NET software controls provide a fast, easy way to communicate with any Modbus slave devices connected to your PC.
- Get your Visual Basic, Visual C, .NET, Excel, or other compatible applications talking Modbus protocol within minutes.
$260 – $350Select options -
IMC-100A: 10/100BaseTX to 100BaseFX Industrial Media Converter
- UTP to Fiber Media Converter
- RJ45 Port Supports Auto MDI/MDI-X Function
$240Select options -
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
$95 – $245Select options -
Terminal Block Replacements
- Simplifies wiring connections on Acromag I/O Modules
- Barrier strip or spring clamp terminal block kits
- Provide safe and secure wiring connections
$30 – $40Select options -
USB-to-Ethernet Adapter
Simplifies configuration of Acromag Ethernet I/O Modules Prevents disruption of existing LANs This device is a USB-to-Ethernet adapter that you can use to communicate with any Acromag Ethernet I/O product for the purpose of setup and re-configuration for your application. It is recommended for initial communication with Acromag Ethernet devices so that you do not have to disrupt your existing network connection.$80Select options
Additional information
Weight | 10 oz |
---|---|
Dimensions | 4.5 × 1.5 × 5 in |
Part Number | 961EN-4006: Modbus TCP/IP and i2o protocol, current, 961EN-6006: Ethernet/IP, current, 962EN-4006: Modbus TCP/IP and i2o protocol, voltage, 962EN-6006: Ethernet/IP, voltage |
Communication | Ethernet/IP, i2o Peer-to-Peer, Modbus TCP/IP |
Power | DC Power |
Product Series | BusWorks 900EN Series |
-
Description
961EN: 6 DC current input channels
962EN: 6 DC voltage input channelsThese modules provide an isolated Ethernet network interface for six analog input channels. Differential inputs eliminate ground loops and thus the need for isolators in many applications. Multi-range inputs accept signals from a variety of sensors and devices. High-resolution, low noise, A/D converters deliver high accuracy and reliability.
Input Ranges: Ranges are selectable for a 3-channel group
DC Current:
0 to 1mA, 0 to 11mA, 0 to 20mA, 4 to 20mA
0 to 20 amps AC (with optional AC sensor)
DC Voltage: ±78mV to ±10V DC (eight range options)
Network Communication:
Ethernet/IP
Modbus TCP/IP, i2o® peer-to-peer available for Modbus TCP/IP only
10/100Mbps
Power Requirement: 15 to 36V DC supply (2 Watts) required
Approvals:
CE/ATEX marked
UL, cUL listed, Class I; Div. 2; Groups A, B, C, D
EtherNet/IP, Modbus/TCP conformance testedPerformance Specifications
Input
Accuracy: Better than ±0.05% of span for nominal input ranges
Analog to Digital Converter (A/D): 16-bit Σ-Δ converter. 0.005% (1/20000) resolution
Noise Rejection: Normal Mode: Better than 40dB @ 60Hz
Common Mode: Better than 140dB @ 60Hz
Input Filter Bandwidth: -3dB at 3Hz, typical
Input Conversion Rate: 80mS per channel
DC Current Input Impedance:Â 25 ohms
DC Voltage Input Impedance: Greater than 110.5K ohmsEnvironmental
Ambient Operating Temperature: -25 to 70°C (-13 to 158°F)
Ambient Storage Temperature: -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity: 5 to 95%, non-condensing
Isolation: 1500V AC for 60 seconds or 250V AC continuous. 3-way isolation between I/O, network, and power -
Features & Benefits
- Configurable from standard web browser
- EtherNet/IP® or Ethernet Modbus TCP/IP communication with automatic 10/100Mbps data rate negotiation
- 6-input stand-alone module is very economical
- i2o function (available ONLY with Modbus TCP/IP) enables direct input-to-output communication without a network controller
- Differential inputs eliminate ground loops
- Universal inputs support a variety of sensors
- High-resolution 16-bit sigma-delta A/D converters ensure precise, high accuracy measurements
- Compact packaging with pluggable terminals saves space and simplifies wiring
- Wide operational temperature range permits installation in extreme environments
-
Tech Papers
How to Connect Acromag Series 9xxEN Modules Via RadioLinx Ethernet ModemsObjective: The purpose of this document is to provide a procedure for connecting an Acromag Series 9xxEN I/O Module to an existing network via RadioLinx Ethernet Modems. Background – IP Addresses Any TCP/IP packet contains two addresses: a unique fixed MAC address, and a unique IP address. To communicate on the Internet, computers must have...How to Communicate with Acromag Modbus/TCP Modules from Ignition Software Application NoteCommunicating with Ignition Software This document illustrates a procedure for configuring OPC tags intended for Acromag Busworks® Series Modbus/TCP modules using Windows software from Inductive Automation. It is assumed that the user has a working knowledge of OPC, Modbus TCP, and Ignition software. Product Features: BusWorks® Series 9xxEN Modules w/Modbus/TCP BusWorks® Series XT1xx1 Modules w/...How to Connect to Acromag Ethernet I/O Devices Application NoteGetting Connected to Acromag Ethernet I/O Devices These instructions summarize the basic steps you will have to take in order to initially connect an Acromag Ethernet I/O product to your Personal Computer (PC) or laptop. To connect an Ethernet device to your PC, consult with your network administrator and either temporarily change the TCP/IP configuration...How to Connect Acromag Series 900EN Ethernet Modules to Your PC Application NoteObjective: The purpose of this document is to provide a procedure for assigning a unique IP address to a second network interface card installed in a personal computer for the purpose of communicating with an Acromag Series 9xxEN Ethernet I/O Module. A procedure for accomplishing IP address assignment is provided using Windows 98, Windows ME, Windows...How to Communicate with Acromag Series 9xxEN-60xx Ethernet Modules from Compact Logix Devices Application NoteCommunicating with Acromag Series 9xxEN-60xx Ethernet Modules from Compact Logix Controllers This document illustrates a procedure for configuring message commands intended for Acromag Busworks® Series Ethernet/IP modules using ladder logic programming software and a Compact Logix Programmable Controller. It is assumed that the user has a working knowledge of ladder logic programming, the RSLogix5000 software,...How to Communicate to Acromag Series 9xxEN-6xxx & XTxx2-xxx Ethernet Modules in an Allen Bradley ControlLogix System Application NoteEthernet Modules in a ControlLogix System Objective: This document illustrates a procedure for integrating the Acromag Series 9xxEN-6xxx modules into the Allen Bradley control system as a third-party generic module. The reference model for this procedure is the Model 961EN-6006. It is assumed that the Acromag module has been assigned a static IP address and...How to Configure Kepware KEPServerEX 5.0 for Communications with Acromag BusWorks Modbus I/O Modules Application NoteConfiguring Kepware KEPServerEX 5.0 for Communications with Acromag BusWorks Modbus I/O modules. Introduction This document provides example steps for configuring the Kepware KEPServerEX OPC Server for communications with Acromag Busworks Modbus RTU and Modbus TCP/IP Distributed I/O Modules. Once the server is configured, data may be read from or written to the I/O module using...How to Configure LabVIEW 2009 to Communicate with Acromag BusWorks and EtherStax Modbus I/O Modules Via an OPC Server Application NoteIntroduction National Instruments LabVIEW can be used to monitor and control Acromag Busworks and Etherstax Modbus I/O Modules via an OPC server. A separate application note, Configuring Kepware KEPServerEX 5.0 for Communications with Acromag Busworks and Etherstax Modbus I/O Modules, outlines configuration of a KEPServerEX OPC server. This document focuses on setting up controls and...How to Configure Omron CJ2H PLC's with Ethernet/IP for Use with Acromag Ethernet/IP Remote I/O Application NotePurpose: Acromag Ethernet/IP I/O with Omron CJ2H PLC’s This document walks the user through the configuration of the Cx-One Network Configurator software that is used in conjunction with Omron CJ2H PLC’s. It is assumed that the user has a working knowledge of the PLC and Cx-One software. Configuring the CxOne “Network Configurator” Start the Cx-One...How to Communicate to Acromag Series 9xxEN-60xx Ethernet Modules using PCCC from Compact Logix Devices Application NotePCCC Messaging with CompactLogix This document illustrates a procedure for configuring PCCC message commands for Acromag Series 9xxEN Ethernet/IP modules using ladder logic programming and a Compact Logix Controller. It is assumed that the user has a working knowledge of ladder logic programming, the RSLogix5000 software, and the Compact Logix hardware. Configuring PCCC Messaging Using...How to Communicate to Ethernet Modules from Legacy Allen Bradley or Rockwell Automation Devices Application NoteThis document illustrates a procedure for configuring message commands for Acromag Series 9xxEN Ethernet/IP modules using ladder logic programming and an SLC5\05 Programmable Logic Controller. It is assumed that the user has a working knowledge of ladder logic programming, the RSLogix500 software, and the SLC 5\05 hardware. Setup of PCCC Communication to Series 9xxEN-60xx I/O...How to Configure the Wonderware MBENET I/O Server to Communicate with the Acromag 9xxEN Ethernet Modules Application NoteWonderware MBENET The purpose of this document is to provide a procedure for configuring MBENET I/O Server (ie: Modicon Ethernet I/O Server) to communicate with an Acromag Series 9xxEN Ethernet I/O Module. It is assumed that the user has a working knowledge of Wonderware and how to link the Wonderware application to the Wonderware I/O...How to Communicate to Acromag Series Ethernet Modules from Red Lion HMIs Application NoteRed Lion HMIs This document illustrates a procedure for configuring message commands for Acromag Ethernet modules using the Red Lion Crimson 2.0 Software. It is assumed that the user has a working knowledge of the Crimson 2.0 software, as well as a Red Lion HMI. Setting up Communications From a new or existing project, double... -
Specs & Data Sheets
Specifications
Manuals
Brochure
-
Software
-
Accessories
-
20RM-16-DIN: 19” rack-mount kit with DIN rail
- 19" rack-mount kit with DIN rail
$185Select options -
4001 Serial Cables
5-foot ribbon cable, DB25 male and 26-pin female IDC connectors, for 3B/5B backpanel to Ethernet I/O module connection$95Select options -
5020-350: Toroidal AC Current Sensor
- AC Current Sensor to precondition an AC current input signal
- Highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low level, DC milliampere signal (0 to 11.17mA).
$50Select options -
5035 Series: Ethernet Cables
- Ethernet straight cable, CAT5
- Ethernet crossover cable, CAT5E
- Low EMI Double-Shielded Ethernet Patch Cable
$40 – $115Select options -
900EN: 5-Port Ethernet Switch
- 10/100Mbps
- 15 to 36V DC power supply required
- Five shielded RJ-45 sockets, 8-pin, 10Base-T / 100Base-TX
$340Select options -
AMTN, AMTX: ActiveX / .NET Controls for Modbus I/O
- Modbus/TCP or Modbus/RTU
- These ActiveX / .NET software controls provide a fast, easy way to communicate with any Modbus slave devices connected to your PC.
- Get your Visual Basic, Visual C, .NET, Excel, or other compatible applications talking Modbus protocol within minutes.
$260 – $350Select options -
IMC-100A: 10/100BaseTX to 100BaseFX Industrial Media Converter
- UTP to Fiber Media Converter
- RJ45 Port Supports Auto MDI/MDI-X Function
$240Select options -
PS5R: Slim Line Power Supplies
- 10W, 15W, 30W, 60W, 90W, 120W, and 240W models
- Universal Input (85-264V AC / 100-370V DC)
- Lightweight and compact size
$95 – $245Select options -
Terminal Block Replacements
- Simplifies wiring connections on Acromag I/O Modules
- Barrier strip or spring clamp terminal block kits
- Provide safe and secure wiring connections
$30 – $40Select options -
USB-to-Ethernet Adapter
Simplifies configuration of Acromag Ethernet I/O Modules Prevents disruption of existing LANs This device is a USB-to-Ethernet adapter that you can use to communicate with any Acromag Ethernet I/O product for the purpose of setup and re-configuration for your application. It is recommended for initial communication with Acromag Ethernet devices so that you do not have to disrupt your existing network connection.$80Select options
-
-
Additional information
Additional information
Weight 10 oz Dimensions 4.5 × 1.5 × 5 in Part Number 961EN-4006: Modbus TCP/IP and i2o protocol, current, 961EN-6006: Ethernet/IP, current, 962EN-4006: Modbus TCP/IP and i2o protocol, voltage, 962EN-6006: Ethernet/IP, voltage
Communication Ethernet/IP, i2o Peer-to-Peer, Modbus TCP/IP
Power DC Power
Product Series BusWorks 900EN Series
Please login to submit this form.