- 16-chanel single-ended voltage input
- DB25 port for 8B modules
- Modbus TCP/IP communication
These modules interface high-level analog input signals to an Ethernet control network. A high-performance design ensures reliable measurements and dependable operation.
958EN Single-Ended Voltage Input Ethernet Modules Description
958EN-4016: Industrial-grade units
958EN-4C16: Commercial-grade units
These modules interface high-level analog input signals to an Ethernet control network. A high-performance design ensures reliable measurements and dependable operation.
The DB25 port provides a parallel connection to a rack of 8B analog input modules. The 8B modules provide an isolated front-end with signal conditioning of up to 16 sensor signals.
Industrial-grade models add a configurable integrator/totalizer plus superior accuracy and temperature performance compared to the economical commercial-grade version.
Input Ranges: ±5V DC via DB25 port connection (default) or ±10V DC.
Ethernet Communication: Modbus TCP/IP, 10/100Base-T(X).
Power Requirement: 18 to 36V DC, 2.0W.
Approvals: CE, UL/cUL (industrial-grade units only) Zone 2, Class 1, Division 2, ABCD.
Learn more about the 900EN Series and view all models >
958EN Single-Ended Voltage Input Ethernet Modules Features & Benefits
- DB25 port provides an easy connection to a rack of uB signal conditioning modules (4, 8, or 16 ch panels supported)
- High-resolution 16-bit A/D
- Fast scanning of all channels in 8mS
- 3-way isolation and surge suppression
- Configurable integration/totalization function with non-volatile memory
- Dual-format 16/32-bit data registers
- Scaling registers on all channels
- Configurable sample averaging
- Automatic calibration and self-test
- User-adjustable TCP Ports 1-99,999 for advanced network configuration
- Web browser configuration with copy utility for fast setup
Specifications
Manuals
-
5035 Series: Ethernet Cables
- Ethernet straight cable, CAT5
- Ethernet crossover cable, CAT5E
- Low EMI Double-Shielded Ethernet Patch Cable
Additional information
Weight | 10 oz |
---|---|
Dimensions | 4.5 × 1.5 × 5 in |
Part Number | 958EN-4016: Industrial-grade with integrator, 958EN-4C16: Commercial-grade no integrator |
Product Series | BusWorks 900EN Series |
Communication | Modbus TCP/IP |
-
Description
958EN Single-Ended Voltage Input Ethernet Modules Description
958EN-4016: Industrial-grade units
958EN-4C16: Commercial-grade unitsThese modules interface high-level analog input signals to an Ethernet control network. A high-performance design ensures reliable measurements and dependable operation.
The DB25 port provides a parallel connection to a rack of 8B analog input modules. The 8B modules provide an isolated front-end with signal conditioning of up to 16 sensor signals.
Industrial-grade models add a configurable integrator/totalizer plus superior accuracy and temperature performance compared to the economical commercial-grade version.
Input Ranges: ±5V DC via DB25 port connection (default) or ±10V DC.
Ethernet Communication: Modbus TCP/IP, 10/100Base-T(X).
Power Requirement: 18 to 36V DC, 2.0W.
Approvals: CE, UL/cUL (industrial-grade units only) Zone 2, Class 1, Division 2, ABCD.
Learn more about the 900EN Series and view all models >
958EN Single-Ended Voltage Input Ethernet Modules Features & Benefits
- DB25 port provides an easy connection to a rack of uB signal conditioning modules (4, 8, or 16 ch panels supported)
- High-resolution 16-bit A/D
- Fast scanning of all channels in 8mS
- 3-way isolation and surge suppression
- Configurable integration/totalization function with non-volatile memory
- Dual-format 16/32-bit data registers
- Scaling registers on all channels
- Configurable sample averaging
- Automatic calibration and self-test
- User-adjustable TCP Ports 1-99,999 for advanced network configuration
- Web browser configuration with copy utility for fast setup
-
Tech Papers
How to Connect Ethernet I/O Modules with RadioLinx Ethernet Modems - 8500770Connecting Acromag Series 900EN I/O Modules to an existing network with RadioLinx Ethernet Modems Background – IP Addresses Any TCP/IP packet contains two addresses: a unique fixed MAC address, and a unique IP address. To communicate on the Internet, computers must have unique identifiers in order to differentiate one computer from another. This is accomplished...How to Determine Flow Totalization Utilizing Analog Ethernet I/O - 8400956Flow Totalization Utilizing Analog Ethernet I/O Defining the Problem: A municipality wants to monitor water usage and does not have the capability to scale analog data. They want an all-in-one solution which will read, scale, and totalize the inputs from the flow meters. System Requirements: Flow meters producing a DC current (±20mA, 0-20mA, 4-20mA) or...How to Communicate with Modbus/TCP Modules from Ignition Software - 8501121Setting Up and Communicating with Acromag Series 9xxEN-40xx and XTxxx1-xxx Modbus/TCP Modules and EtherStaxâ„¢ Modbus/TCP from Ignition Software This document illustrates a procedure for configuring OPC tags intended for Acromag BusWorks® Series Modbus/TCP modules using Windows software from Inductive Automation. It is assumed that the user has a working knowledge of OPC, Modbus TCP, and...How to Connect to Acromag Ethernet I/O Devices - 8500815Getting Connected to Acromag Ethernet I/O Devices These instructions summarize the basic steps you will have to take in order to initially connect an Acromag Ethernet I/O product to your Personal Computer (PC) or laptop. To connect an Ethernet device to your PC, consult with your network administrator. Either temporarily change the TCP/IP configuration of...How to Connect Acromag 900EN Ethernet Modules to Your PC - 8500734Connecting Acromag Series 900EN Ethernet Modules to Your PC Objective: The purpose of this document is to provide a procedure for assigning a unique IP address to a second network interface card installed in a personal computer for the purpose of communicating with an Acromag Series 9xxEN Ethernet I/O Module. A procedure for accomplishing IP address... -
Specs & Data Sheets
Specifications
Manuals
-
Software
-
Accessories
-
5035 Series: Ethernet Cables
- Ethernet straight cable, CAT5
- Ethernet crossover cable, CAT5E
- Low EMI Double-Shielded Ethernet Patch Cable
-
-
Additional information
Additional information
Weight 10 oz Dimensions 4.5 × 1.5 × 5 in Part Number 958EN-4016: Industrial-grade with integrator, 958EN-4C16: Commercial-grade no integrator
Product Series BusWorks 900EN Series
Communication Modbus TCP/IP
Please login to submit this form.