uBDC1: DC Power Module
Please sign in or register to see model options and to add products to your cart.
Product short description:
- Wide-Range DC Voltage Input
- 5V/1A DC Output to Backpanel
- Supports Redundant Power
The uBDC1 power module allows a backpanel populated with I/O modules to operate off DC power voltage levels other than 5V. This optional module plugs into a special socket on the backpanel to convert a power supply voltage from 10-32V DC to 5V/1A which will drive up to 16 I/O modules. uBDC1 modules include over-voltage, reverse-voltage and short-circuit protection (current limiting).
Click here to watch a short AcroMaggie video highlighting the features of the microBlox® Series.
Acromag’s microBlox® uB Series I/O modules offer a compact, high-performance solution for interfacing sensors and field devices with data acquisition systems. uB signal conditioning modules are ideal to isolate, filter, convert and amplify a wide variety of signal types for test, measurement and control systems. Just plug uB modules into 4, 8, or 16-channel backpanels in any mix for a high-density analog I/O interface. Channel-to-channel isolation provides optimal noise and surge protection from ground loops, spikes, and high common mode voltages.
The uBDC1 power module allows a backpanel populated with I/O modules to operate off DC power voltage levels other than 5V. This optional module plugs into a special socket on the backpanel to convert a power supply voltage from 10-32V DC to 5V/1A which will drive up to 16 I/O modules. uBDC1 modules include over-voltage, reverse-voltage and short-circuit protection (current limiting).
With the uBDC1 power module, users can also implement redundant power methods for the backpanel. In redundant applications, the uBDC1 becomes the primary power source.
Performance Specifications
See Backpanels for additional system specifications.
General
Dimensions:
Height: 1.380” with connectors. 0.970” without
Width: 0.425”
Length: 1.425”
Input: 10-32V DC
Output Voltage: 5V DC ±5% (4.7V to 5.3V range)
Output Current: 1A (1.25A absolute maximum)
Efficiency: 90% typical
Output Ripple: Less than 150mVp-p, typical
Response Time: Less than 15ms typical
Over-Voltage Protection: TVS in module plus additional TVS protection provided on backpanel
Current-Limiting: Built-In, plus additional limiting provided on backpanel
Reverse-Voltage Protection: Built-In, plus additional protection provided on backpanel
Filtering: Transient voltage suppression, capacitors, & common-mode I/O filtering
Line Regulation: Less than 0.005% 10-32V, 1A, typical
Load Regulation: Less than 4%, 0.05A to 1A, typical
Environmental
Operating Temperature: -40 to 80°C (-40° to 176°F)
Ambient Operating Temperature: -40°C to +80°C, no deration
Storage Temperature: -40 to 85°C (-40° to 185°F)
Relative Humidity: 0 to 95% non-condensing
Isolation:
Non-isolated
Power is common to host-side of I/O
Shock and Vibration Immunity:
Conforms to:
IEC 60068-2-6: 10-500 Hz, 4G, 2 hours/axis, for sinusoidal vibration.
IEC 60068-2-64: 10-500 Hz, 4G-rms, 2 hours/axis , for random vibration.
EC 60068-2-27: 25G, 11ms half-sine, 18 shocks at 6 orientations, for mechanical shock.
Electromagnetic Compatibility (EMC) Compliance:
Minimum immunity per BS EN 61000-6-1 (2007):
CE marked, per EMC Directive 2004/108/EC. Electrostatic Discharge Immunity (ESD), per IEC 61000-4-2.
Radiated Field Immunity (RFI), per IEC 61000-4-4
Electrical Fast Transient Immunity (EFT), per IEC 61000-4-4
Surge Immunity, per IEC 61000-4-5
Conducted RF Immunity (CRFI), per IEC 61000-4-6
Emissions:
Class B product with emissions per BS EN 61000-6-3 (2007+A1:2011): enclosure port, per CISPR 16
Low voltage AC mains port, per CISPR 16
Approvals:
CE compliant. RoHS Compliant.
UL/cUL Class 1, Division 2, Groups ABCD.
ATEX Zone 2.
- Allows use of wide range 10-32V DC power supplies to operate backpanels
- Enables implementation of redundant power to uB backpanels.
- Polarized to only fit in panel power slot
- Over-molded circuit has superior shock, vibration, moisture, and dust protection.
- -40 to 80°C (-40 to 176°F) operation
- UL, cUL Class I, Div 2, ABCD and ATEX Zone 2 hazardous location approvals
Manuals
uBDC1 User Manual (Log in to download the file)
-
microBlox® multiLogger Data Logging Mobile App
The Acromag microBlox® multiLogger collects data from one or more uB series data acquisition modules. With this data logger app, you can:- Log data from up to 14 microBlox signal conditioning devices simultaneously.
- Scale inputs in custom engineering units to correspond with the native output range.
- View real-time data or trend charts for quick field diagnostics and easy troubleshooting.
- Save data logs and share via email or iCloud.
- Download on iTunes or Google Play
-
uB04, uB08, uB16: Back Panels
- uB module carriers
- 4, 8, or 16 channel versions
- DIN-rail option
- CJC sensor
$165 – $450Select options
Additional information
Weight | N/A |
---|---|
Dimensions | N/A |
Part Number | uBDC1: microBlox uB Non-Isolated Power Supply |
Product Series | microBlox Series |
-
Description
Acromag’s microBlox® uB Series I/O modules offer a compact, high-performance solution for interfacing sensors and field devices with data acquisition systems. uB signal conditioning modules are ideal to isolate, filter, convert and amplify a wide variety of signal types for test, measurement and control systems. Just plug uB modules into 4, 8, or 16-channel backpanels in any mix for a high-density analog I/O interface. Channel-to-channel isolation provides optimal noise and surge protection from ground loops, spikes, and high common mode voltages.
The uBDC1 power module allows a backpanel populated with I/O modules to operate off DC power voltage levels other than 5V. This optional module plugs into a special socket on the backpanel to convert a power supply voltage from 10-32V DC to 5V/1A which will drive up to 16 I/O modules. uBDC1 modules include over-voltage, reverse-voltage and short-circuit protection (current limiting).
With the uBDC1 power module, users can also implement redundant power methods for the backpanel. In redundant applications, the uBDC1 becomes the primary power source.
Performance Specifications
See Backpanels for additional system specifications.
General
Dimensions:
Height: 1.380” with connectors. 0.970” without
Width: 0.425”
Length: 1.425”
Input: 10-32V DC
Output Voltage: 5V DC ±5% (4.7V to 5.3V range)
Output Current: 1A (1.25A absolute maximum)
Efficiency: 90% typical
Output Ripple: Less than 150mVp-p, typical
Response Time: Less than 15ms typical
Over-Voltage Protection: TVS in module plus additional TVS protection provided on backpanel
Current-Limiting: Built-In, plus additional limiting provided on backpanel
Reverse-Voltage Protection: Built-In, plus additional protection provided on backpanel
Filtering: Transient voltage suppression, capacitors, & common-mode I/O filtering
Line Regulation: Less than 0.005% 10-32V, 1A, typical
Load Regulation: Less than 4%, 0.05A to 1A, typicalEnvironmental
Operating Temperature: -40 to 80°C (-40° to 176°F)
Ambient Operating Temperature: -40°C to +80°C, no deration
Storage Temperature: -40 to 85°C (-40° to 185°F)
Relative Humidity: 0 to 95% non-condensing
Isolation:
Non-isolated
Power is common to host-side of I/O
Shock and Vibration Immunity:
Conforms to:
IEC 60068-2-6: 10-500 Hz, 4G, 2 hours/axis, for sinusoidal vibration.
IEC 60068-2-64: 10-500 Hz, 4G-rms, 2 hours/axis , for random vibration.
EC 60068-2-27: 25G, 11ms half-sine, 18 shocks at 6 orientations, for mechanical shock.
Electromagnetic Compatibility (EMC) Compliance:
Minimum immunity per BS EN 61000-6-1 (2007):
CE marked, per EMC Directive 2004/108/EC. Electrostatic Discharge Immunity (ESD), per IEC 61000-4-2.
Radiated Field Immunity (RFI), per IEC 61000-4-4
Electrical Fast Transient Immunity (EFT), per IEC 61000-4-4
Surge Immunity, per IEC 61000-4-5
Conducted RF Immunity (CRFI), per IEC 61000-4-6
Emissions:
Class B product with emissions per BS EN 61000-6-3 (2007+A1:2011): enclosure port, per CISPR 16
Low voltage AC mains port, per CISPR 16
Approvals:
CE compliant. RoHS Compliant.
UL/cUL Class 1, Division 2, Groups ABCD.
ATEX Zone 2. -
Features & Benefits
- Allows use of wide range 10-32V DC power supplies to operate backpanels
- Enables implementation of redundant power to uB backpanels.
- Polarized to only fit in panel power slot
- Over-molded circuit has superior shock, vibration, moisture, and dust protection.
- -40 to 80°C (-40 to 176°F) operation
- UL, cUL Class I, Div 2, ABCD and ATEX Zone 2 hazardous location approvals
-
Specs & Data Sheets
Manuals
uBDC1 User Manual (Log in to download the file)
-
Software
-
Accessories
-
microBlox® multiLogger Data Logging Mobile App
The Acromag microBlox® multiLogger collects data from one or more uB series data acquisition modules. With this data logger app, you can:- Log data from up to 14 microBlox signal conditioning devices simultaneously.
- Scale inputs in custom engineering units to correspond with the native output range.
- View real-time data or trend charts for quick field diagnostics and easy troubleshooting.
- Save data logs and share via email or iCloud.
- Download on iTunes or Google Play
-
uB04, uB08, uB16: Back Panels
- uB module carriers
- 4, 8, or 16 channel versions
- DIN-rail option
- CJC sensor
$165 – $450Select options
-
Additional information
Additional information
Weight N/A Dimensions N/A Part Number uBDC1: microBlox uB Non-Isolated Power Supply
Product Series microBlox Series
Please login to submit this form.