Click to zoom

Please sign in or register to see model options and to add products to your cart.

Product short description:
  • Multi-range ±15V, ±75V, or ±150V input
  • 4-20mA outputs (sink/source)
  • 7-32V DC loop/local power

The SP238 model is a high-performance signal splitter that converts one high-level DC voltage input into two proportional isolated 4-20mA control signals. power is received from one or both output loop currents.

Click here to watch a short video highlighting the features of the Acromag SP Series.

SP238: Two-Wire High Voltage Input Signal Splitter Description

The SP238 model is a high-performance signal splitter that converts one high-level DC voltage input into two proportional isolated 4-20mA control signals.

Power is received from one or both output loop currents.

Setup is fast and easy with a USB connection to your PC and our Windows software. Acromag’s Agility™ mobile app enables configuration on an Android smart phone or tablet.

Software simplifies I/O range scaling, calibration, and advanced signal processing capabilities.

High-voltage isolation separates the input and between the output circuits. The isolation protects from surges, reduces noise, and eliminates ground loop errors.

These rugged instruments withstand harsh industrial environments to operate reliably across a wide temperature range with very low drift. They feature high immunity to RFI, EMI, ESD, and EFT, plus low radiated emissions.

IMPORTANT: To prevent ground loop error between a grounded PC and a grounded input signal, Acromag strongly recommends use of a USB isolator like Acromag’s USB-Isolator when configuring a SP230 Series transmitter.

Learn more about the SP Series and view all models >

SP238: Two-Wire High Voltage Input Signal Splitter Features & Benefits

  • Easy configuration via USB with Windows software or Agility app for Android
  • Single unit accepts ±15V, ±75V, and ±150V DC input ranges
  • Input scales independently at each output
  • User-selectable filtering (none, low, med, high)
  • User-configurable output range clamp levels support NAMUR-compliant operation
  • Supports reverse-acting (inverse) output
  • Supports sink or source output wiring
  • Very low 7V two-wire loop burden
  • High accuracy, linearity, stability, and reliability
  • 1500V isolation
  • Space-saving 17.5mm (0.69 inch) design with pluggable terminals for easier wiring
  • Shock (25g) and vibration (4g) resistant
  • Wide ambient operation (-40 to 80°C)
  • CE compliant. UL/cUL Class I Div 2, ATEX / IECEx Zone 2 approvals

Learn more about the SP Series and view all models >

Compare Series TT, DT, and SP Single/Dual-Channel Isolated Transmitters and Signal Splitters Guarantee Dependable Value >

What is Circuit Grounding and Why is it Important? - 8500993 (Log in to view the file)
Why is Circuit Grounding Important? This whitepaper is Part 1 of a three-part Grounding Electrical Equipment Best Practices series that looks at grounding and its role in protecting personnel, equipment, and ensuring the integrity of electrical signals. In this part, we will review circuit grounding and its importance to you, as well as the US...
How Do Ground Fault Circuit Interrupters Work & Protect Us from Shock? - 8500020 (Log in to view the file)
How do ground fault circuit interrupters work? This Electrical Ground Rules white paper is Part 2 of a three-part series that takes a look at grounding and its role in protecting personnel and equipment, and ensuring the integrity of electrical signals. In this part, we will examine our use of ground as a means of...
How does Ground Work as a Voltage Stabilizer and Transient Limiter? - 8501021 (Log in to view the file)
What is the role of ground as a voltage stabilizer and transient limiter? This Electrical Ground Rules whitepaper is Part 3 of a three-part series that takes a look at grounding and its role in protecting personnel and equipment, and ensuring the integrity of electrical signals. Consideration of ground can be very complex and application...
TTC-SIP: Software Interface Package Information Page (Log in to download the file)
SP Series Windows Configuration Software (Log in to download the file)
Agility Config Tool (Tethered) (Log in to download the file)
  • Compare

    SP230-Config/Cal

    Factory custom configuration/calibration service. Specify input type, input/output zero and full-scale values, filtering, and sensor fault settings on order.
    Select options
  • Compare

    TTBus-Kit: DIN Rail Bus Power Connector

    • One kit supports multiple TT330 series transmitters.
    • For multiple DT330/351 or SP330 transmitters, one TTBUS-KIT is required for each transmitter to be DC Power wired via the bus rail power connections.
       
    Select options
  • Compare

    TTC-SIP: Software

    • Software Interface Package for Acromag DT, ST, TT Series Transmitters and SP, uBSP Series Signal Splitters.
    • Includes configuration sofware CD-ROM (5040-xxx), isolator (USB-ISOLATOR) and two USB cable (4001-112, 4001-113) (Recommend one kit per customer.)
    • Easy setup and digital calibration via USB with Windows configuration software.
    • Download the configuration software only - from the Software Tab
    Select options
  • Compare

    USB Cables

    Select options

Additional information

Weight 8 oz
Dimensions 4 × 4.75 × 1 in
Part Number

SP238-0600: Signal Splitter

Configuration

Agility Mobile App, USB Configuration, Windows Software Configuration

Product Series

SP230 Series

Power Type

Loop Power

  • Description

    SP238: Two-Wire High Voltage Input Signal Splitter Description

    The SP238 model is a high-performance signal splitter that converts one high-level DC voltage input into two proportional isolated 4-20mA control signals.

    Power is received from one or both output loop currents.

    Setup is fast and easy with a USB connection to your PC and our Windows software. Acromag’s Agility™ mobile app enables configuration on an Android smart phone or tablet.

    Software simplifies I/O range scaling, calibration, and advanced signal processing capabilities.

    High-voltage isolation separates the input and between the output circuits. The isolation protects from surges, reduces noise, and eliminates ground loop errors.

    These rugged instruments withstand harsh industrial environments to operate reliably across a wide temperature range with very low drift. They feature high immunity to RFI, EMI, ESD, and EFT, plus low radiated emissions.

    IMPORTANT: To prevent ground loop error between a grounded PC and a grounded input signal, Acromag strongly recommends use of a USB isolator like Acromag’s USB-Isolator when configuring a SP230 Series transmitter.

    Learn more about the SP Series and view all models >

    SP238: Two-Wire High Voltage Input Signal Splitter Features & Benefits

    • Easy configuration via USB with Windows software or Agility app for Android
    • Single unit accepts ±15V, ±75V, and ±150V DC input ranges
    • Input scales independently at each output
    • User-selectable filtering (none, low, med, high)
    • User-configurable output range clamp levels support NAMUR-compliant operation
    • Supports reverse-acting (inverse) output
    • Supports sink or source output wiring
    • Very low 7V two-wire loop burden
    • High accuracy, linearity, stability, and reliability
    • 1500V isolation
    • Space-saving 17.5mm (0.69 inch) design with pluggable terminals for easier wiring
    • Shock (25g) and vibration (4g) resistant
    • Wide ambient operation (-40 to 80°C)
    • CE compliant. UL/cUL Class I Div 2, ATEX / IECEx Zone 2 approvals

    Learn more about the SP Series and view all models >

    Compare Series TT, DT, and SP Single/Dual-Channel Isolated Transmitters and Signal Splitters Guarantee Dependable Value >

  • Tech Papers

    What is Circuit Grounding and Why is it Important? - 8500993 (Log in to view the file)
    Why is Circuit Grounding Important? This whitepaper is Part 1 of a three-part Grounding Electrical Equipment Best Practices series that looks at grounding and its role in protecting personnel, equipment, and ensuring the integrity of electrical signals. In this part, we will review circuit grounding and its importance to you, as well as the US...
    How Do Ground Fault Circuit Interrupters Work & Protect Us from Shock? - 8500020 (Log in to view the file)
    How do ground fault circuit interrupters work? This Electrical Ground Rules white paper is Part 2 of a three-part series that takes a look at grounding and its role in protecting personnel and equipment, and ensuring the integrity of electrical signals. In this part, we will examine our use of ground as a means of...
    How does Ground Work as a Voltage Stabilizer and Transient Limiter? - 8501021 (Log in to view the file)
    What is the role of ground as a voltage stabilizer and transient limiter? This Electrical Ground Rules whitepaper is Part 3 of a three-part series that takes a look at grounding and its role in protecting personnel and equipment, and ensuring the integrity of electrical signals. Consideration of ground can be very complex and application...
  • Specs & Data Sheets

  • Software

    TTC-SIP: Software Interface Package Information Page (Log in to download the file)
    SP Series Windows Configuration Software (Log in to download the file)
    Agility Config Tool (Tethered) (Log in to download the file)
  • Accessories

    • Compare

      SP230-Config/Cal

      Factory custom configuration/calibration service. Specify input type, input/output zero and full-scale values, filtering, and sensor fault settings on order.
      Select options
    • Compare

      TTBus-Kit: DIN Rail Bus Power Connector

      • One kit supports multiple TT330 series transmitters.
      • For multiple DT330/351 or SP330 transmitters, one TTBUS-KIT is required for each transmitter to be DC Power wired via the bus rail power connections.
         
      Select options
    • Compare

      TTC-SIP: Software

      • Software Interface Package for Acromag DT, ST, TT Series Transmitters and SP, uBSP Series Signal Splitters.
      • Includes configuration sofware CD-ROM (5040-xxx), isolator (USB-ISOLATOR) and two USB cable (4001-112, 4001-113) (Recommend one kit per customer.)
      • Easy setup and digital calibration via USB with Windows configuration software.
      • Download the configuration software only - from the Software Tab
      Select options
    • Compare

      USB Cables

      Select options
  • Additional information

    Additional information

    Weight 8 oz
    Dimensions 4 × 4.75 × 1 in
    Part Number

    SP238-0600: Signal Splitter

    Configuration

    Agility Mobile App, USB Configuration, Windows Software Configuration

    Product Series

    SP230 Series

    Power Type

    Loop Power